• Title/Summary/Keyword: plant operation

Search Result 2,268, Processing Time 0.026 seconds

Radioactivity Calculation Considering Kori Unit 1 Operation History for the Defected Baffle Former Bolts (고리1호기 가동이력을 고려한 손상 배플포머볼트 방사화 계산)

  • Young Jae Maeng;Hyun Chul Lee;Myeong Ho Lee;Seong Sik Hwang;Seung Jin Oh;Yun Suk Jang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.1
    • /
    • pp.20-26
    • /
    • 2023
  • The defected baffle former bolts of Kori unit 1 were withdrawn to analyze the cause of damage and gamma-ray measurement is being scheduled. Prior to that, in order to calculate the specific radioactivity value of the baffle former bolt, a radioactivity calculation method considering the actual operation history of the nuclear power plant is introduced and the calculation results are shown. In particular, the radioactivity calculation method considering the operation history is obtained by defining the monthly contribution factor from the actual monthly operation history. As a result, the results considering operation history are 16-28% lower than the general radioactivity calculation results. These results can contribute to establish a reasonable but economical strategy when planning nuclear power plant decommissioning.

Demonstration of EPRI CHECWORKS Code to Predict FAC Wear of Secondary System Pipings of a Nuclear Power Plant

  • Lee, Sung-Ho;Seong Jegarl;Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.375-384
    • /
    • 1999
  • The credibility of CHECWORKS FAC model analysis was evaluated for plant application in a model plant chosen for demonstration. The operation condition at each pipe component was defined before the wear rate analysis by plant data base, water chemistry analysis, and network flow analysis. The predicted wear was compared with the measured wear for 57 sample components selected from 43 susceptible line groups analysed. The inspected 57 locations represent components of highest predicted wear in each line group. Both absolute value and relative ranking comparisons indicated reasonable correlations between the predicted and the measured values. Four components showed much higher measured wear rates than the predicted ones in the feed water train from main feed water pump discharge to steam generator, probably due to high hydrazine concentration operation the effect of which had not been incorporated into the CHECWORKS model. The measured wear was higher than the predicted one consistently for components with least susceptibility to FAC. It is believed that the conservatism maintained during UT data analysis dominated the measurement accuracy. A great deal of enhancement is anticipated over the current plant pipe management program when a comprehensive plant pipe management program is implemented based on the model analysis.

  • PDF

An Intelligent Human-Machine Interface for Next Generation Nuclear Power Plants

  • Park, Seong-Soo;Park, Jin-Kyun;Hong, Jin-Hyuk;Chang, Soon-Heung;Kim, Han-Gon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.191-196
    • /
    • 1995
  • The intelligent human-machine interface (HMI) has been developed to enhance the safety and availability of a nuclear power plant by improving operational reliability The key elements of the HMI are the large display panels which present synopsis of the plant status and the compact, digital work stations for the primary operator control and monitoring functions. The work station consists of four consoles such as a dynamic alarm console (DAC), a system information console (SIC), a computerized operating-procedure console (COC), and a safety related information console (SRIC). The DAC provides clean alarm pictures, in which information overlapping is excluded and alarm impacts are discriminated, for quick situation awareness. The SIC covers a normal operation by offering all necessary plant information and control functions. In addition, it is closely linked with the DAC and the COC to automatically display related system information under the request of these consoles. The COC aids the operator with proper emergency operation guidelines so as to shutdown the plant safely, and it also reduces his physical/mental burden by automating the operating procedures. The SRIC continuously displays safety related information to allow the operator to assess the plant status focusing on plant safety. The proposed HMI has been validated and demonstrated with on-line data obtained from the full-scope simulator for Yonggwang Units 1,2.

  • PDF

A Pilot Study of Improving the Atmospheric Environment of Classroom for Students' Learning Activities

  • Kim, Tae-Han;Lee, Hanju;Choi, Boo-Hun;Hyun, Hye Sun
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.2
    • /
    • pp.179-194
    • /
    • 2021
  • Background and objective: Plant-based biofilter system has become a promising candidate for improving indoor air quality due to its eco-friendly and sustainable nature. However, it remains controversial whether indoor air purification using a biofilter is effective. Methods: This study used the one-group pre- and post-test design to analyze the effects of the operation of the plant-based biofilter system on indoor air quality, students' perception of indoor air quality, health effects, and subjective and objective attentiveness. Results: Results of this study show that the application of the plant-based biofilter system changed the air environment in the classroom. The operation of the plant-based biofilter system significantly decreased PM2.5 and PM10 and slightly increased temperature and humidity. Satisfaction with air quality and subjective attentiveness were significantly improved but objective attentiveness and health effects were not improved. Conclusion: Further studies need to be conducted for improving indoor air quality of schools and evaluating the health effects and attention of occupants to present the objective performance of the plant-based biofilter system.

A cell operation scheme in CIM factory (CIM 공장의 단위 cell 운용 방안 연구)

  • 김성식;최기범;김진호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.811-816
    • /
    • 1992
  • The objective of cell operation in CIM is to maximize system efficiency, not the cell itself. We introduce a cell operation scheme that pursues the direction. For specific cases, work center and AS/RS are closely investigated. Structures of their operation mechanism and methods of job scheduling are introduced along with an expert system developed for the scheme. The cell operation softwares developed are now under test at K.U.FMS, a model CIM plant.

  • PDF

The Investigation and Improvement plan of Contracting-out municipal wastewater treatment plant system in Korea (국내 하수처리장 관리대행 현황 및 제도 개선 방안)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.2
    • /
    • pp.211-215
    • /
    • 2017
  • The market of the municipal wasetewater treatment plant (MWTP) operation is expanding across the world including Korea. The contracting-out system was introduced for the effective operation of MWTPs. However, an improvement of the contracting-out system of MWTP has been continuously required. This research investigated current operational status of MWTPs in Korea, to suggest the improvement of the cost effective MWTP operation to promote the contracting-out system of MWTP operation. Results showed that lower operational costs of MWTP were lower in larger MWTPs than in smaller MWTPs. Overall, MWTPs operated by a public enterprise showed lower operational costs than those operated by government agencies and private enterprises. Among the MWTPs similar in their treatment capacity, treatment process and operation period, MWTPs operated by private enterprises showed the lowest operational cost. According to the survey, managers and operators of MWTPs emphasized the importance of improvement on the methods of selecting operating agencies and estimating operationing costs. The results of this study should be useful as important supporting data to promote the contracting-out system for the MWTP operation.

OOUS : An Educational System for the Optimal Operation of Utility Plants (OOUS : 유틸리티 플랜트의 교육용 최적운전시스템)

  • Oh, Sang-Hun;Yeo, Yeong-Koo
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.147-155
    • /
    • 2008
  • The economics of most chemical plants are heavily dependent upon the management of the utilities used in the plants. The utilities are supplied by the centralized utility system of the plant. Among the various utilities the steam is by far the most important energy source and the management of the electricity and the process water are greatly affected by the steam. Therefore it is necessary to educate students and new employees the basic concepts about the effective distribution of the utilities and the fundamental strategies to apply the concepts in actual plant operations. The OOUS (Optimal Operation of Utility System) is an GUI educational system designed to educate the effective generation of the steam and the optimal steam distribution schemes within short period. The OOUS deals with various utility equipments and processes and shows how to save operation costs by displaying the optimal operation conditions based on the process models and the operational knowledgebase.

New High Recovery Membrane Modules for Desalination

  • Fujiwara, Nobuya
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.1-12
    • /
    • 2002
  • Desalination by reverse osmosis (RO), which first entered commercial use in the 1970s, was initially mainly used for treating brackish water. Technological progress led to the development of an RO membrane enabling single-pass seawater desalination. Toyobo succeeded in developing a single-pass seawater desalination RO module composed of hollow fiber type membranes made of cellulose triacetate in 1978, and then in 1979 began production of the first commercially available double-element module. This double-element module has many advantages suitable for seawater desalination. It has high chlorine tolerance and high salt rejection, derived from the properties of the membrane material, and it is highly resistant to fouling and scaling matters due to the unique flow pattern and fiber bundle configuration. These advantages help to explain why the Toyobo double-element module has been used so successfully at the many seawater desalination plants around the world. Since the 1980s, large plants capable of desalinating several tens of thousands of cubic meters a day have sprung up around the Mediterranean and In the Middle East. The Jeddah RO Phase I Plant, which has a capacity of 56, 800m$^3$/day, went into operation in 1989. In 1994, the same sized Phase II Plant came on stream, giving the plant a huge total capacity of 113, 600m$^3$/day. The plant constructor Mitsubishi Heavy Industries, Ltd. (MHI), and the RO membrane manufacturer Toyobo Co., Ltd. In 1998, the world's largest RO seawater desalination plant in operation, which has a capacity of 128, 000m$^3$/day and is run by Saudi Arabia's Saline Water Conversion Corporation (SWCC), went into operation at Yanbu. RO seawater desalination technology has thus already reached the stage of full-scale commercial use. In order to encourage its wider use, however, RO desalination needs to be made more economical by lowering construction and water treatment costs. Toyobo has therefore developed a new economical RO desalination system by a recovery ratio of 60% using a high-pressure module with a high product flow rate. In 2000, Toyobo high recovery membrane module was selected for the largest seawater desalination plant in Japan, which has a capacity of 50, 000m$^3$/day.

  • PDF

Simulation of Benzene-Toluene-Xylene Plant (BTX제조공정의 모사연구)

  • 정해동
    • Journal of the Korea Society for Simulation
    • /
    • v.4 no.1
    • /
    • pp.121-130
    • /
    • 1995
  • This paper deals with modeling and simulation of an industrial benzene-toluene-xylene plant. Because the fractionation unit of benzene-toluene-xylene plant has a narrow range of boiling point and doesn't have any sidecut and side reboiler, we employed boiling point estimation method in the modeling and simulation of the plant. Soave-Redlich-Kwong equation was used in the computation of thermodynamical properties. We solved resulting nonlinear equations by using Newton-Raphson method which is known to show fast convergence. Results of simulation showed good agreement with actual plant operation data.

  • PDF