• Title/Summary/Keyword: plant engineering

Search Result 9,449, Processing Time 0.042 seconds

Characteristics of Water Quality Parameters of Han River Related to THMs Formation in Water Treatment Plants in Seoul (서울시 정수장의 THMs 생성과 관련된 한강 원수의 주요 수질 특성 조사)

  • Lee, Jin-Hyo;Lee, Ki-Seon;Hwang, Dong-Hyun;Lee, Man-Ho;Han, Sun-Hee;Park, Yong-Sang;Lee, Mok-Young;Lee, Jin-Sook;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.886-892
    • /
    • 2011
  • In a study on THMs formation at the distribution facilities in Seoul water supply for past 3 years from 2007 to 2009, THMs production was increased from inlet to outlet during the process in water treatment plant. However, such increased THMs amount was very small compared to THMs production formed after pre-chlorination and post chlorination. Accordingly, this study is aimed to investigate the characteristics of water quality parameters of Han River related to THMs formation in 6 water treatment plants in Seoul. The results showed that THMs and other factors such as temperature (r = 0.539~0.846) and turbidity (r = 0.421~0.863) had positive correlation while THMs had negative correlation with pH (r = -0.613~-0.800) and algae (r = -0.582~-0.901). There is no correlation between THMs and $NH_3-N$. According to the factor analysis, generally metabolite and organic matter factor $X_1$ (pH, BOD, algae), and seasonal and natural factor $X_2$ (temperature, turbidity) played an important role in the formation of THMs. Multiple regression analysis for THMs formation showed significance of regression appeared in most water systems.

Characteristics of Biodegradation of Geosmin using BAC Attached Bacteria in Batch Bioreactor (정수처리용 생물활성탄(BAC) 부착 박테리아를 이용한 회분식 반응기에서의 Geosmin 생분해 특성)

  • Son, Hee-Jong;Jung, Chul-Woo;Choi, Young-Ik;Jang, Seong-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.7
    • /
    • pp.699-705
    • /
    • 2010
  • In this study, three different biological activated carbons (BACs) were prepared from activated carbons made of each coal (F400, Calgon), coconut (Samchully) and wood(Pica, Picabiol) which were run for two and half years in the pilot plant. The attached bio-film microorganisms in and on the BACs were isolated and identified. The results showed that nine different bacteria species (Chryseomonas luteola, Stenotrophomonas maltophilia, Pseudomonas vesicularis, Aeromonas hydrophila, Spingomonas paucimobilis, Agrobacterium radiobacter, Pseudomonas fluorescens, Spirillum spp., and Pasteurella haemolytica) were isolated and identified, the dominant species was Pseudomonas sp. that had occupied 56.5%. More specifically, it was observed that the populations of the microorganisms deceased in the order: Pasteurella haemolytica (18.9%) > Chryseomonas luteola (4.0%) > Agrobacterium radiobacter (3.5%) > Aeromonas hydrophila (2.0%) in and on the BACs. After isolating of 9 species of biofilm microorganisms, the growth curve for the biomass was investigated. During 24~96 hours, the biomass has the highest concentration, and activity of the biomass was the best to uptake geosmin as carbon resources. The operation temperatures for investigating the biodegradation of geosmin were set at $4^{\circ}C$ and $25^{\circ}C$. Pseudomonas vesicularis, Pseudomonas fluorescens, Agrobacterium radiobacter and Stenotrophomonas maltophilia played a maior role in removing the target compound as geosmin. However, geosmin was not biodegraded well by Chryseomonas luteola, Spingomonas paucimobilis, and Spirillum spp.. It is also interesting to evaluate kinetics of biodegradability of geosmin. The first-order rate constants for biodegradability of geosmin at $4^{\circ}C$ and $25^{\circ}C$ were $0.00006{\sim}0.0002\;hr^{-1}$ and $0.0043{\sim}0.0046\;hr^{-1}$ respectively. Higher water temperature produced better geosmin removal rates. When concentrations of geosmin increased from 10 to 10,000 ng/L, the rate constants for biodegradability of geosmin increased from 0.0003 to $0.0882\;hr^{-1}$. As described earlier, higher geosmin concentration in the reactor produced higher rate constant.

Characteristics of Nutrients Release by Submerged Plants in Flood Control Reservoirs within Juam Lake (주암호 홍수조절용지내 침수 식물체의 영양염류 용출 특성)

  • Kang, Se-Won;Seo, Dong-Cheol;Han, Myung-Ja;Han, Jong-Hak;Lim, Byung-Jin;Park, Jong-Hwan;Kim, Kap-Soon;Lee, Yeong-Jae;Choi, Ik-Won;Lee, Young-Han;Heo, Jong-Soo;Kim, Hyun-Ook;Cho, Ju-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.2
    • /
    • pp.271-277
    • /
    • 2011
  • To improve the quality of water from water supply source and to establish the management plan of dead plants in flood control reservoir around Juam Lake, the effect of water quality by dead plant in column with passing time was investigated. In column test, the amounts of release by Carex dimorpholepis were $7,893-7,917mg\;m^{-2}\;month^{-1}$ COD, $2,711-2,816mg\;m^{-2}\;month^{-1}$ T-N and $342-547mg\;m^{-2}\;month^{-1}$ T-P. The amounts of release by Miscanthus sacchariflorus were $6,487-6,507mg\;m^{-2}$ COD, $1,813-1,868mg\;m^{-2}$ T-N and $226-405mg\;m^{-2}\;month^{-1}$ T-P in column. Therefore, the release of COD, T-N and T-P by Carex dimorpholepis were more than those by Miscanthus sacchariflorus Benth in column.

Analysis of Urban Heat Island Intensity Among Administrative Districts Using GIS and MODIS Imagery (GIS 및 MODIS 영상을 활용한 행정구역별 도시열섬강도 분석)

  • SEO, Kyeong-Ho;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.1-16
    • /
    • 2017
  • This study was conducted to analyze the urban heat island(UHI) intensity of South Korea by using Moderate Resolution Imaging Spectroradiometer(MODIS) satellite imagery. For this purpose, the metropolitan area was spatially divided according to land cover classification into urban and non-urban land. From the analysis of land surface temperature(LST) in South Korea in the summer of 2009 which was calculated from MODIS satellite imagery it was determined that the highest temperature recorded nationwide was $36.0^{\circ}C$, lowest $16.2^{\circ}C$, and that the mean was $24.3^{\circ}C$, with a standard deviation of $2.4^{\circ}C$. In order to analyze UHI by cities and counties, UHI intensity was defined as the difference in average temperature between urban and non-urban land, and was calculated through RST1 and RST2. The RST1 calculation showed scattered distribution in areas of high UHI intensity, whereas the RST2 calculation showed that areas of high UHI intensity were concentrated around major cities. In order to find an effective method for analyzing UHI by cities and counties, analysis was conducted of the correlation between the urbanization ratio, number of tropical heat nights, and number of heat-wave days. Although UHI intensity derived through RST1 showed barely any correlation, that derived through RST2 showed significant correlation. The RST2 method is deemed as a more suitable analytical method for measuring the UHI of urban land in cities and counties across the country. In cities and counties with an urbanization ratio of < 20%, the rate of increase for UHI intensity in proportion to increases in urbanization ratio, was very high; whereas this rate gradually declined when the urbanization ratio was > 20%. With an increase of $1^{\circ}C$ in RST2 UHI intensity, the number of tropical heat nights and heat wave days was predicted to increase by approximately five and 0.5, respectively. These results can be used for reference when predicting the effects of increased urbanization on UHI intensity.

Seasonal Investigation of Natural Organic Matters from Yeongsan River Basin by Fluorescence Spectroscopy (영산강 수계 자연유기물질의 계절별 형광특성 연구)

  • Lee, Dong-Jin;Chon, Kang-Min;Jung, Soo-Jung;Kim, Sang-Don;Lee, Kyung-Hee;Hwang, Tae-Hee;Hwang, Dong-Jin;Lim, Byung-Jin;Cho, Jae-Weon
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.1
    • /
    • pp.42-51
    • /
    • 2012
  • This study investigated the characteristics of natural organic matter (NOM) with general water characteristics (pH, DO, electrical conductivity, BOD, COD, TN, TP, Chl-$a$, DOC, $UV_{254}$, SUVA) and the 3D fluorescence excitation-emission matrix (FEEM) in the Yeongsan River basin. FEEM was used to classify protein-like and fulvic & humiclike substances with fluorescence intensity in the matrix of excitation and emission wavelength. The concentration of BOD, COD, TN, electrical conductivity and DOC in the region of Gwangju city (Gwangju sewage treatment plant: GJS, Gwangjucheon: GJC, Gwangju 2: GJ2) was relatively higher than the upper reaches and lower reaches of the Yeongsan River basin. SUVA in most sites was lower than 3 L $mg^{-1}\;m^{-1}$ as the hydrophilic substances, except Damyang (DY) in the upper reaches of Yeongsan river was higher than 3 L $mg^{-1}\;m^{-1}$ as the hydrophobic substances during winter and autumn. In the FEEM investigation the fulvic and humic substances were found in most sites, and in sites regarding Gwangju city (GJS, GJC, GJ2) during winter and GJC in summer, protein-like substances were found. The trend of fluorescence intensities from the upper reaches to the lower reaches in most sites corresponded to that regarding the concentration of water characteristics (BOD, COD, TN, DOC). That is why the region of Gwangju city (GJS, GJC, GJ2) was relatively higher. This results were an equivalent trend to those of fluorescence index (FI) in most sites, and the higher FIs in the sites of Gwangju city indicate more microbial-derived substances due to enormous effluent organic matters (EfOM) from huge Gwangju sewage treatment plants.

Economic Analysis of the Livestock Manure Treatment System Using Life-Cycle Cost Technique (LCC 기법을 통한 가축분뇨처리시설의 경제성 분석)

  • Kim, J.H.;Cho, S.H.;Kwag, J.H.;Choi, D.Y.;Jeong, K.H.;Chung, U.S.;Chung, M.S.;Park, S.K.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.61-68
    • /
    • 2011
  • To assess the total cost with all stages of facilities, the feasibility of Life Cycle Cost (LCC) analysis was examined in this study to estimate the livestock manure treatment system and optimal decision making process. For the economic evaluation, the plant/equipment investment and annual operation cost of four Public Livestock Recycling Facilities, whose treatment capacity is 100 ton piggery manure per day, was compared. The initial cost was in the range of 2,699 million won to 3,202 million won, where T and E methods were highest and lowest, respectively. The annual operation cost was in the level of 378 million to 498 million won, which decreased in the following order : T method > J method > E method > B method. For the LCC analysis, 4.7% of interest rate, 3.13% of inflation rate, and 1.52% of net discount rate was considered by the data received from Bank of Korea and Statics Korea in the period of 2000 to 2009. Also, for the calculation of present value factor, the durable years of civil engineering & construction, machinery and electric instrument was 30 years, 10 years and 15 years, respectively. Based on these consideration, operation cost was in the range of 17,570 won/ton to 20,661 won/ton, and E method (17,570 won/ton) was economical and B method (20,661 won/ton) was non-economical. Though initial cost of T method was higher than that of B method, LCC analysis of T method was lower than that of T method due to the lower operation cost. Therefore, LCC analysis, which considers both initial cost and operation cost, is more reasonable evaluation method than either initial cost or annual operation cost. For the change of LCC analysis according to the uncertainty, the sensitivity analysis was carried out using fluctuation magnitude of discount rate in the period of 2000 to 2009. As a result, LCC analysis evaluated by discount rate was stable for the uncertain factors since the cost leadership did not change even though the sensitivity analysis varied. In summary, the economic evaluation using LCC analysis could be an efficient reference to choose the suitable livestock manure treatment plants. Furthermore, standardization of statement calculation for the actual cost analysis should be conducted and more detailed study is necessary to validate this summary. Therefore, the application of comprehensive technology evaluation, which considers LCC analysis, should contribute in obtaining objectivity and enhancing reliability for the 'Evaluation of Livestock Manure Treatment System and its Technology'.

Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System (이류체 포그 냉방시스템의 제어알고리즘 개발)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experiments for the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the cooling effect was 1.2 to $4.0^{\circ}C$ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogging interval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency to increase as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid fogging system increased, there was a tendency for the cooling efficiency to improve. However, as the inside air approaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level could make higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased and the difference between absolute humidity of inside and outside air increased. The more fog evaporated, the difference between absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapor due to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increase in the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the fogging time needed to change of saturation deficit of $10g{\cdot}kg^{-1}$ was 120 seconds and stopping time was 60 seconds. But in order to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturation deficit was set to $5g{\cdot}kg^{-1}$ and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and their control algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulating only the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to $32^{\circ}C$ and the upper limit of relative humidity at 85 to 90%.

Management Strategies of Ventilation Paths for Improving Thermal Environment - A Case Study of Gimhae, South Korea - (도시 열환경 개선을 위한 바람길 관리 전략 - 김해시를 사례로 -)

  • EUM, Jeong-Hee;SON, Jeong-Min;SEO, Kyeong-Ho;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.115-127
    • /
    • 2018
  • This study aims to propose management strategies of ventilation paths for improving urban thermal environments. For this purpose, Gimhae-si in Gyeongsangnamdo was selected as a study area. We analyzed hot spots and cool spots in Gimhae by using Landsat 8 satellite image data and spatial statistical analysis, and finally derived the vulnerable areas to thermal environment. In addition, the characteristics of ventilation paths including wind direction and wind speed were analyzed by using data of the wind resource map provided by Korea Meteorological Administration. As a result, it was found that a lot of hot spots were similar to those with weak wind such as Jinyoung-eup, Jillye-myeon, Juchon-myeon and the downtown area. Based on the analysis, management strategies of ventilation paths in Gimhye were presented as follows. Jinyoung-eup and Jillye-myeon with hot spot areas and week wind areas have a strong possibility that hot spot areas will be extended and strengthened, because industrial areas are being built. Hence, climate-friendly urban and architectural plans considering ventilation paths is required in these areas. In Juchon-myeon, where industrial complexes and agricultural complexes are located, climate-friendly plans are also required because high-rise apartment complexes and an urban development zone are planned, which may induce worse thermal environment in the future. It is expected that a planning of securing and enlarging ventilation paths will be established for climate-friendly urban management. and further the results will be utilized in urban renewal and environmental planning as well as urban basic plans. In addition, we expect that the results can be applied as basic data for climate change adaptation plan and the evaluation system for climate-friendly urban development of Gimhye.

Changes of characteristics of livestock feces compost pile during composting period and land application effect of compost (축분 퇴비화과정 중 특성변화와 축분퇴비 이용효과)

  • Jeong, Kwang-Hwa;Kang, Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.1
    • /
    • pp.56-64
    • /
    • 2001
  • Composting of livestock feces is economic and safe process to decrease the possibility of direct leakage of organic pollutants to ecosystem from commercial and environmental point of view. This study was conducted with three different experiments related to composting of livestock feces. The purpose of experiment 1 was to investigate changes of characteristic of compost pile during composting period by low temperature in cold season. To compare composting effect of experimental compost pile and control pile exposed in cold air, experimental compost piles were warmed up by hot air until their temperatures were reached at $35^{\circ}C$. Sawdust, Ricehull and Ricestraw were mixed with livestock feces as bulking agent. The highest temperatures of compost pile during composting period were in sawdust, rice hull, rice straw, and control were $75^{\circ}C$, $76^{\circ}C$, $68^{\circ}C$, $45^{\circ}C$ respectively. Moisture content, pH, C/N and volume of compost were decreased during composting period. Experiment 2 was carried out to study utilization effect of compost by plant. A corn was cultivated for 3 years on fertilized land with compost and chemical fertilizer. The amount of harvest and nutrition value of corn were analyzed. In first year of trial, the amount of harvest of corn on land treated with compost was lower by 20% than that of land treated with chemical fertilizer. In second year, there was no difference in yield of com between compost and chemical fertilizer. In third year, the yield of com on land fertilized with compost was much more than that of land fertilized with chemical fertilizer. The purpose of experiment 3 was to estimate the decrease of malodorous gas originating from livestock feces by bio-filter. Four types of bio-filters filled with saw dust, night soil, fermented compost and leaf mold were manufactured and tested. Each bio-filter achieved 87-95% $NH_3$ removal efficiency. This performance was maintained for 10 days. The highest $NH_3$ removal efficiency was achieved by leaf mold on the first day of operation period. It reduced the concentration of $NH_3$ by about 95%. Night soil and fermented compost showed nearly equal performance of 93 to 94% for 10 days from the beginning of operation. The concentration of hydrogen sulfide and methyl mercaptan originating for compost were equal to or less than $3mg/{\ell}$ and $2mg/{\ell}$, respectively. After passing throughout the bio-filter, hydrogen sulfide and methyl mercaptan were not detected.

  • PDF

A Study on Fractionation and Characterization of Water-Soluble Natural Fe-Chelates From Garbage Compost and Activated Sewage Sludge (활성오니(活性汚泥) 및 진개퇴비중(塵芥堆肥中) 수용성(水溶性) 철(鐵) 킬레이트의 분리(分離)와 특성(特性)에 관(關)한 연구(硏究))

  • Park, Nae-Joung;Lindsay, W.L.
    • Applied Biological Chemistry
    • /
    • v.18 no.4
    • /
    • pp.194-202
    • /
    • 1975
  • This study was conducted to study the properties of the water-soluble natural chelating agents from garbage compost and activated sewage sludge responsible for Fe chelation, which is closely associated with the effectiveness in correcting iron chlorosis in plant. The water-soluble fraction of these materials was fractionated by menas of Sephadex gel filtration and the fractions of Fe chehates were traced by radioactive $^{59}Fe$. The fractions were examined by ultraviolet and infrared. spectroscopy and stability constants for Fe. The water-soluble fraction from garbage compost was separated by Sephadex G-25 into approximately four fractions. Most of the added $^{59}Fe$ was associated with fraction I, which appeared at the void volume. Further fractionation by Sephadex G-50 indicated that the molecular weight of water-soluble chelating agents is in the approximate range of 5000 to 10,000. The water-soluble fraction from activated sewage sludge gave six fractions by Sephadex G-25. Most of the added $^{59}Fe$ was found in the fraction I,II, and III, The molecular weights of most chelating agents associated with $^{59}Fe$ appeared to be less than 5,000 and those of fraction I that appeared at the void volume was in the range of 5,000 to 1,000. Discrepancy between radio activity count and UV absorption indicated the heterogeneity of the fractions obtained by Sephadex gel filtration. Ultraviolet absorption spectra of all fractions separated by Sephadex G-25 and containing chelating agents showed no differences. Fraction IV and V of sewage extract showed absorption maxima and shifting similar to nucleic acid components suggesting the presence of decomposition products of nucleic acid. Similarity fraction VI contained phenolic type amino acid groups. Fraction I of compost extract contained most of the added $^{59}Fe$ and showed weak but extra definite absorption in the 1230, and $1270cm^{-1}$ region, suggesting that extra oxygen groups in polyphenolic structure were probably involved in Fe chelation. In sewage extract, fraction I,II, and III in which most of the $^{59}Fe$ was found, showed strong definite polypeptide absorption in the region of $1540cm^{-1}$ due to NH deformation and C-N stretching of amide groups in the peptidebond. These extra functional groups in fraction I, II, and III appeared to be associated with Fe chelation. The other fractions, not associated with $^{59}Fe$, still have carboxyl and hydroxyl groups, suggesting that these functional groups in these water extracts may not independently form the Fe chelates. Precipitation of ferric hydroxide precluded measuring the stability constants for Fe-chelates. However, the formation constants for Zn chelates as log K values for compost extract and sewage extract at pH 4.0 from which the strength of chelation with Fe could be presumed, were 8.23, and 9.75, respectively, indicating strong complexation with metals. The chelating capacity of compost extract containing 6.5 g organic matter per liter was 0.82 mM, and that of sewage extract containing 5.3 g per liter was 0. 64 mM.

  • PDF