• Title/Summary/Keyword: plain water

Search Result 448, Processing Time 0.025 seconds

Characteristics of Diffusion Coefficient of High Performance Concrete using GGBFS for Road Structures by Accelerating Test Method (슬래그 미분말 혼입률에 따른 도로구조물용 고성능 콘크리트의 압축강도 및 촉진 염소이온 확산 특성)

  • Han, Seong-Woo;Kim, Hong-Sam;Lee, Chan-Young;Cheong, Hai-Moon;Ahn, Tae-Song
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.885-888
    • /
    • 2008
  • In recent years, the terminology "High-Performance Concrete(HPC)" has been introduced into the construction industry. Most high-performance concretes have a high cementitious content and a low water-cementitious material ratio. The proportions of the individual constituents vary depending on local preferences and local materials. Therefore, many trial batches are usually necessary before a successful mix is developed. The objective of this experiments is to investigate the fundamental properties of high performance concrete based binary cimentitious materials such as ordinary portland cement and ground granulated blast furnace slag. The results from the study will be utilized as the basic data and guideline in making standard mixproportions and the manufacture, construction work and quality control of HPC

  • PDF

Evaluation of Nutrient Discharges from Greenhouses with Flooding Soil Surface at Two Different Locations (입지조건이 다른 시설재배지에서 담수처리에 따른 양분 용탈량 평가)

  • Kim, Min-Kyeong;Roh, Kee-An;Ko, Byong-Gu;Park, Seong-Jin;Jung, Goo-Bok;Lee, Deog-Bae;Kim, Chul-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.3
    • /
    • pp.315-321
    • /
    • 2010
  • Greenhouse soil cultivated with excessive compost and chemical fertilizer has been an issue to deteriorate soil and water quality in the environment. The objective of this study was to evaluate the nutrient outflow by desalting method, flooding soil surface, after vegetable cropping in greenhouse soils. Field experiment from July to September 2008, was conducted to quantify greenhouse locations, i.e. alluvial plain and local valley. The changes of desalinization in both locations were higher as the amounts of irrigated and drained water were increased. Particularly, the ratio of desalinization in alluvial plain was much higher (66.7%) than the one in local valley (45.6%). However, $NH_4$-N contents of local valley soil during the flooding were higher than in those of alluvial plain. This was caused by high total nitrogen and organic matter in local valley soil than those in alluvial plain soil. With comparing to the input and output loads of T-N and T-P in greenhouses with local valley and alluvial plain soils, the output loads of nutrients were larger than the input loads of nutrients. This result showed that the flooding soil surface can be a good treatment to desalinize greenhouse soils. However, this conclusion remained that the flooding water containing high N and P concentrations might cause the secondary effect on the quality of streams and groundwater since excessive nutrient concentrations can be the main cause of eutrophication problem in aquatic environment.

Flux of Dissolved Organic and Inorganic Constituents in Forested Headwater Streams

  • Choi, Byoung-Koo;Mangum, Clay N.;Hatten, Jeffery A.;Dewey, Janet C.;Ouyang, Ying
    • Journal of Environmental Science International
    • /
    • v.21 no.10
    • /
    • pp.1171-1179
    • /
    • 2012
  • Headwaters initiate material export to downstream environments. A nested headwater study examined the flux of dissolved constituents and water from a perennial stream and four ephemeral/intermittent streams in the Upper Gulf Coastal Plain of Mississippi. Water was collected during storm and baseflow conditions. Multiple linear regression was used to model constituent concentration and calculate flux. Event was the major source of water discharged from the ephemeral and intermittent streams however, baseflow was the major source for water discharged by the perennial stream during events. The perennial stream had an area weighted average yields of 10.1, 0.01, 1.03, 0.65 kg/ha/yr of DON (dissolved organic nitrogen), $NO_3^-$-N, $NH_4^+$-N and $PO_4^{-3}$, respectively while large variabilities existed between the ephemeral and intermittent streams. These findings highlight the importance of headwaters in protecting the low order drainage basins as a key to water quality within perennial streams.

Establishment of reference intake of water for Korean adults in 2015 (2015 한국 성인의 수분 섭취기준 설정)

  • Lee, Jae-Hyun;Kim, Sun-Hyo
    • Journal of Nutrition and Health
    • /
    • v.50 no.2
    • /
    • pp.121-132
    • /
    • 2017
  • Purpose: This review was performed to establish a reference intake of water for Korean (KDRI-water) adults in 2015 by examining current knowledge of the relationship between water intake and health and the general status of water intake and loss. We expect that this study will be utilized for further refinement of KDRI-water. Methods: Documents were searched using RISS, NDSL, DBPIA, CINAHL, and Pubmed with the keywords 'water intake, water supply, water ingestion, hydration, dehydration, water balance, and fluid balance'. Results: Water balance is essential for the maintenance of health. Based on this assumption, numerous studies have been performed to investigate the association of water intake with several diseases such as urolithasis, obesity, diabetes, and cancer as well as other health problems, including constipation, cognition, and fetal weight. Effects of water intake for prevention or relief of these health problems vary. Water is supplied to the body by eating foods and drinking liquids such as plain water and beverages. Metabolic water is another source of water input. Water is lost through urine, skin, respiration, and feces. KDRI-water 2015 was set by adequate intake (AI) based on water intake volume, which was the sum of water intakes from foods and fluids reported by the Korea National Health and Nutrition Examination Survey, with extra milk intake of 200 mL. AIs in some age groups were modified considering their estimated energy requirements. Conclusion: Accurate data of water intake is critically important for the establishment of KDRI-water. Therefore, improvement of systems investigating water intake is required, and more studies on the status of water intake and loss in Korean people are needed for definite KDRI-water establishment.

A Study on the Improvement of Heat Transfer Performance in Low Temperature Closed Thermosyphon

  • Han, Kyu-Il;Yee, Seok-Su;Park, Sung-Hyun;Lee, Suk-Ho;Cho, Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1102-1111
    • /
    • 2002
  • The study focuses on the heat transfer performance of two-phase closed thermosyphons with plain copper tube and tubes having 50, 60, 70, 80, 90 internal grooves. Three different working fluids(distilled water, methanol, ethanol) are used with various volumetric liquid fill charge ratio from 10 to 40%. Additional experimental parameters such as operating temperature and inclination angle of zero to 90 degrees are used for the comparison of heat transfer performance of the thermosyphon. Condensation and boiling heat transfer coefficients, heat flux are obtained using experimental data for each case of specific parameter. The experimental results are assessed and compared with existing correlations. The results show that working fluids, liquid fill charge ratio, number of grooves and inclination angle are very important factors for the operation of thermosyphons. The relatively high rate of heat transfer is achieved when the thermosyphon with internal grooves is used compared to that with plain tube. The optimum liquid fill charge ratio for the best heat transfer performance lies between 25% and 30%. The range of the optimum inclination angle for this study is 20$^{\circ}$~30$^{\circ}$ from the horizontal position.

Sinusitis and Adenoid size is related to Snoring in children (코골이를 주소로 내원한 환자의 부비동염과 아데노이드 비후와의 관계)

  • Lee, Hai-Ja
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.17 no.1
    • /
    • pp.17-27
    • /
    • 2003
  • Background: Snoring in children, is associated Kith adenotonsillar hypertrophy and sinusitis which contribute to upper airway obstruction, so we studied the sinusitis and adenoid size of snoring children with plain radiography Materials and method: Fifty patients having snoring, nasal obstruction in our hospital between November 2001 and November 2002 were studied using plain radiology PNS(water's view) and Neck lateral view(adenoid size with A/N ratio) Results: 1. In oriental medicine, Hu-Bi means laryngopharyngeal edema and obstruction, laryngopharyngeal disease are due to Hwa-Yeoul( fire and hot), sinus disease are due to Fung-Han(wind and cold) and Fung-Yeoul(wind and hot). 2. Age ranged from 2 to 17 year-old ( mean age: 6 years), 5-7 year-old were 18 patients (36%). Age of on set, 25 patients were 1-4 year-old (50%). 3. Of the 50 snoring patients, 37 patients were sinusitis(74%), 20 patients had enlarged adenoid(40%). Of the 20 large adenoid patients, 19 patients were sinusitis(95%). 4. Of the 50 snoring patients, size of tonsil were flowed. Fifteen were severe(3+), 17 patients were moderate(2+) and 15 patients were mild(1+). Of the 20 enlarged adenoid patients, size of tonsil flowed. Five were severe(3+), 11 patients were moderate(2+) and 4 patients were mild(1+). Conclusion : Of the 50 Snoring patients, 37 patients showed sinusitis(74%), 32 patients showed large tonsil(64%), 20 patients showed large adenoid(40%).

  • PDF

A Study on the Performance of Condensation Heat Transfer for Various Working Fluid of Two-Phase Closed Thermosyphons with Various Helical Grooves (나선 그루브형 열사이폰의 작동유체의 변화에 대한 응축열전달 성능에 관한 연구)

  • Han, K.I.;Cho, D.H.;Park, J.U.;Lee, S.J.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.239-244
    • /
    • 2003
  • This study concerns the performance of condensing heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the type of working fluids are very important factors for the operation of thermosyphons. And the maximum enhancement (i.e. the ratio of the heat transfer coefficients the helical thermosyphons to plain thermosyphons) is $1.5{\sim}2$ for condensation.

  • PDF

A Study on the Performance of Condensation Heat Transfer for Various Working Fluid of Two-Phase Closed Thermosyphons with Various Helical Grooves (나선 그루브형 열사이폰의 작동유체의 변화에 대한 응축열전달 성능에 관한 연구)

  • Han, Kyu-Il;Cho, Dong-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.116-122
    • /
    • 2005
  • This study concerns the performance of condensing heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the type of working fluids are very important factors for the operation of thermosyphons. And the maximum enhancement (i.e. the ratio of the heat transfer coefficients the helical thermosyphons to plain thermosyphons) is $1.5{\sim}2$ for condensation.

A Study on Reducing Deterioration in Long-span Slab Concrete (장스팬 슬라브 콘크리트의 열화저감에 대한 연구)

  • Kim, Dae-Geon;Cha, Hun;Choi, Sang-Hwan;Moon, Kyeong-Sik
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.11-12
    • /
    • 2014
  • In this study, fundamental properties of concrete mixed with fiber has been analysed. Compressive strength, tensile strength and plastic shrinkage has been tested to conduct the optimum addition ratio of fiber. Effect to control press concrete's cracking has been tested. The following results could be made as the conclusion. For the flowability, slump decreased about 41-79% when all types of fiber used in the concrete. When the addition ratio of fiber is 1.2%, the slump of concrete decreased about 45%. For the strength properties. all the specimens with different addition ratio of fiber shown higher compressive strength comparing with Plain. Comparing with Plain, cracking decreased when the fiber added. Especially, when NY fiber used in the concrete, the plastic shrinkage did not occurred. In addition, Latex modified concrete(LMC) has improved superior physical and chemical properties. The properties of latex, combined with the low water-cement ratio, produce a concrete that has improved flexural, tensile, and bond strength, lower modulus of elasticity, increased freeze-thaw resistance, and reduced permeability compared to conventional concrete of similar mix design.

  • PDF

A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer - (터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 -)

  • Han, Kyu-Il;Kim, Si-Young;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.5 no.2
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF