• Title/Summary/Keyword: plain

Search Result 3,217, Processing Time 0.026 seconds

A Study on the Preference to the Textiles for Jackets of College Students (재킷용 의복소재에 대한 대학생의 선호도 조사연구)

  • Kim Heesook;Na Mihee
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.10 s.200
    • /
    • pp.105-113
    • /
    • 2004
  • This research was designed to investigate the preferred textiles for the jackets of college students. 105 subjects that majored in fashion design were surveyed. The subjects selected three favorite materials, according to the seasons, among 120 samples presented in a swatch book and their frequency of choice was tallied. The extent of the subjects' preference was compared by season and gender The results of this study were as follows: 1. College students preferred dark Grayish Brown plain variation wool Crossbred foremost as a textile for the spring and fan season. 2. White plain cotton Plisse was the most preferred material for summer. 3. Olive Gray cotton Corduroy was the most preferred textile for winter. 4. For thickness and weight, the textiles chosen for winter were thicker and heavier than those chosen for other seasons. 5. For fiber content, natural fiber such as wool were preferred for all seasons. 6. For the type of fabrics weave, a plain variation weave was preferred for spring and fall, twill was preferred for winter and plain weave was preferred for summer. 7. Collage students preferred gray and brown tones for the spring, fall and winter season. For color characteristics, solid fabrics were generally preferred and check patterns were especially preferred for the winter season. 8. Girl students generally preferred lighter and thinner fabrics than those chosen by boys.

Condensation Heat Transfer Coefficients of R245fa on a Plain Tube (수평관에서 R245fa의 응축 열전달계수)

  • Shim, Yun-Bo;Park, Ki-Jung;Jung, Dong-Soo;Kim, Jong-Seong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.555-562
    • /
    • 2007
  • In this study, condensation heat transfer coefficients (HTCs) of R22, R134a, R245fa and R123 are measured on a horizontal plain tube. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling temperature $3-8^{\circ}C$. Test results show the HTCs of newly developed alternative low vapor pressure refrigerant, R245fa, on a plain tube are 9.5% higher than those of R123 while they are 3.3% and 5.6% lower than those of R134a and R22 respectively. Nusselt's prediction equation for a plain tube underpredicts the data by 13.7% for all refrigerants while a modified equation yielded 5.9% deviation against all data. From the view point of environmental safety and condensation heat transfer, R245fa is a long term good candidate to replace R123 used in centrifugal chillers.

Mechanical Properties and Neutron Shielding Rate of Concrete with Borosilicate-Glasses and Amorphous Boron Steel Fiber (붕규산유리 및 비정질 붕소강 섬유를 혼입한 콘크리트의 역학적 성능 및 중성자 차폐성능 평가)

  • Lee, Jun-Cheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.269-275
    • /
    • 2016
  • In this study, the mechanical properties and the neutron shielding rate of concrete with the borosilicate glass and the amorphous boron steel fiber were investigated. The measures of this investigation includes air contents, slump loss, compressive strength, static modulus of elasticity, compressive toughness, flexural strength, flexure toughness and neutron shielding rate. As a result, the neutron shielding rate of the concrete with borosilicate glasses increased even though the compressive strength and flexural strength decreased in comparison with that of plain concrete. Also, the mechanical toughness and the neutron shielding rate of the concrete with amorphous boron steel fiber increased in comparison with that of plain concrete.

The Changing pattern of the Plain Abdominal Radiogram by Progression of the Intussusception in Children (소아 장중첩증에서 증상 지속 시간에 따른 단순 복부 사진의 변화)

  • Jun, Hyung-Seok;Choi, Young-Cheol;Choi, Seung-Ho
    • Advances in pediatric surgery
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2009
  • The purpose of this study was to determine the success rate of air reduction as the primary treatment of intussusception and whether the success of air reduction could be predicted by plain x-ray. The authors reviewed the medical records of 54 consecutive patients diagnosed with intussusception from Jan 2005 to Dec 2007 at the Department of Surgery, Masan Samsung Hospital. The natures of symptoms and findings of plain abdominal radiography performed in the emergency department (ED) were reviewed. Air reduction failed more frequently (26.3 %) in patients who visited ED more than 24 hours after symptom onset (p=0.009). The mean duration of symptom for operated patients was longer than air reduction group (p=0.01). Also, 3/4 of patients having localized distension of small bowel in the left upper quadrant abdomen had unsuccessful air reduction (p=0.002). In conclusion, the time interval from symptom onset to arrival at ED and localized distension of small bowel in the left upper quadrant abdomen significantly increased the failure rate of air reduction.

  • PDF

A Fundamental Study on the Estimation of Construction Cost of High Fluidity Concrete Applying Flowing Concrete Method (유동화공법에 의해 제조한 고유동 콘크리트의 원가분석에 관한 기초적 연구)

  • 한민철;손성운;오선교;김성수;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.99-102
    • /
    • 2002
  • This paper discusses the estimation of construction cost of high fluidity concrete using segregation reducing type superplasicizer with 350kgf/cm2 of design strength and 60$\pm$5cm of slump flow in order to verify the cost down effect of high fluidity concrete compared with that of plain concrete with 350kgf/cm2 of design strength and 18cm of slump and with 210kgf/cm2 of design strength and 15cm of slump. According to research, under same strength levels, although material cost of high fluidity concrete is somewhat higher than that of plain concrete due to segregation reducing type superplasticizer, labor cost and equipment cost of high fluidity concrete is cheaper than that of plain concrete. However, based on the strength differences, high fluidity concrete shows lower material cost, labor cost and equipment cost than that of plain concrete due to decreasing in size of member and re-bar caused by high strength development of concrete.

  • PDF

Arrangement Methods of Pattern and Weaving Types of Fabrics During 16~17th Century - Centering Flower Patterned Fabrics of Exhumed Clothing in Chosun Dynasty - (16~17세기 직물유형과 문양의 배치구도에 관한 연구 - 조선시대 출토복식에 나타난 화문직을 중심으로 -)

  • Park, Mun-Young;Kim, Ho-Jung;Park, Ok-Lyun
    • Fashion & Textile Research Journal
    • /
    • v.8 no.4
    • /
    • pp.400-406
    • /
    • 2006
  • The purpose of this study is to investigate characteristics of arrangement methods and weaving types of fabrics during 16-17 century. Research was done through the references of exhumed clothing in Chosun Dynesty. Seeing the waving types of fabrics of flower patterned fabrics of total 108 items, satin damask(Dahn) was 71items, took the majority. And the next order was twill(Neung) and plain(Ju). It means Dahn was the most popular fabric among the upper classes. It was regarded as one of the noble textiles, because of its luxurious appearance and pleasant touch. Flower patterned plain fabric(Munju) was found only 9items, even though the plain fabric was the most common used type. Assumed for the reason, Chosun government had restrict to extravagance of the people. In terms of the arrangement of flower pattern, it can be classified into three methods. The most common arrangement method was Arabesque type, followed by open order shaped type and scattering shaped type. In the repetition of pattern, there were brick-shaped pattern and half drop pattern which were spread flower pattern all over the surface of fabric.

The Variation of Mechanical Properties with Directions of PET High Stretch Fabrics (PET 고신축사 직물의 방향에 따른 역학적 특성의 변화)

  • 김영민;박종범;김주애;조현혹
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.1
    • /
    • pp.160-167
    • /
    • 2002
  • Stretch fabrics are wide-spread for high performance clothing use with requirements of fitness and adaptability to human's movement. A newly developed 100% PET high stretch fabric has excellent properties with respect to stretch, softness, bulkiness, and apparent volume compared to PET filament fabrics. The 100% PET high stretch fabric shows advantages of a dimensional stability, dye and agent adaptability in dying and finishing process, a property of stretch recovery after washing and lower production cost than that of spandex fabric. KES-FB was used to measure mechanical properties to various directions of the fabric. This study centered on whether the 100% PET high stretch fabric is suitable to quality and shape retention of fabric by testing several properties including tensile, compression, shear, bending and surface characteristic to various measuring directions. Tensile linearity showed maximum value at $0^{\circ}$ in plain and $90^{\circ}$ in twill. Shear Stiffness of plain and twill showed maximum value equally at $45^{\circ}\;and\;135^{\circ}$. Bending rigidity showed maximum value at $0^{\circ}$ in plain and $45^{\circ}$ twill. Mean deviation of MIU showed maximum value at $0^{\circ}\;and\;90^{\circ}$ in plain and $135^{\circ}$ in twill.

3D simulation of railway bridges for estimating fundamental frequency using geometrical and mechanical properties

  • Moazam, Adel Mahmoudi;Hasani, Nemat;Yazdani, Mahdi
    • Advances in Computational Design
    • /
    • v.2 no.4
    • /
    • pp.257-271
    • /
    • 2017
  • There are many plain concrete arch bridges in Iran that have been used as railway bridges for more than seventy years. Owe to the fact that these bridges have not been designed seismically, and even may be loaded under high-speed trains, evaluation of fundamental frequencies of the bridges against earthquake and high-speed train vibrations is necessary for considering dynamics effects. To evaluate complex behavior of these bridges, results of field tests are useful. Since it is not possible to perform field tests for all arch bridges, these structures should be simulated correctly by computers for structural assessment. Several parameters are employed to describe the bridges, such as number of spans, length of spans, geometrical and material properties. In this study, results of field tests are used for modal analysis and adapted for 64 three dimensional finite element models with various physical parameters. Computer simulations show length of spans has important effect on fundamental frequencies of plain concrete arch bridge and modal deformations of bridges is in longitudinal and transverse directions. Also, these results demonstrate that fundamental frequencies of bridges decrease after increasing span length and number of spans. Plus, some relations based in the number of spans (n) and span length (l) are proposed for calculation of fundamental frequencies of plain concrete arch bridge.

Landscape Planting Design for Yeoyido Flood Plain Park in Han-river (한강 여의도지구 수변공원 식재설계)

  • 이준복
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.5
    • /
    • pp.86-95
    • /
    • 2003
  • It had been strictly prohibited to plant in waterway according to Korea laws and regulations. It was then made possible to plant by the modification law and regulation of 10/30/1997. In 2000, the Seoul metropolis government planted in the Yeoyido flood plain park in Han river by way of showing the model case. This planting design is for the Yeoyido flood plain park along the Han river, in Seoul. The design requirements were to create a pleasant rest area, to improve the surrounding landscape, and to create diverse ecological habitats by planting within the stability of flood flow. This design emphasizes the following design requirements that has positive effect on stabilizing flood flow. First, planting suitable in a area was determined by the speed of a current of less than 0.7m/sec under various numerical value simulations. Second, plants were selected in existing trees of the present and the past Han river, as well as the questionnaire results from landscape professional engineers and professors. Shade plants were planted in the large visiting areas so as to offer pleasant shade in the summer, the ecological planting pattern was applied in the area with low speed of flood flow, so as to aid the restoration of the natural ecological environment. It was found that the foresaid planting design verified the stability of flood flow and wind by overturn limit moment calculation. It is expected that this plan would serve environmentally friendly planting plans in flood plain park.

Physical Properties of Various Structured Knitted Fabrics (니트의 편성조직에 따른 물성 평가)

  • Yea, Su-Jeong;Song, Wha-Soon
    • Fashion & Textile Research Journal
    • /
    • v.13 no.6
    • /
    • pp.990-995
    • /
    • 2011
  • This study analyzed the effects of the knit stitch type, fiber composition, and yarn thickness on the mechanical properties of knitted fabric. The results were as follows: The course density was the highest in the case of the rib stitch. On the other hand, the wale density was the highest in the case of the float stitch. The thickness was the highest in the case of the rib stitch. The same results were obtained even for different fiber compositions and yarn thicknesses considered in this study. The burst strength of wool knit fabric was higher than that of A/W knit fabric. The stiffness was the lowest in the case of the plain stitch. The same results were obtained even for different fiber compositions and yarn thicknesses. The pilling properties were excellent for all knit stitches, fiber composition, and yarn thicknesses as pilling degree : 5. The air permeability decreased in the following order : rib > plain > float stitch. The same results were obtained even for different fiber compositions and yarn thicknesses. The heat retention rate decreased in the following order : rib > float > plain stitch. The same results were obtained even for different fiber compositions and yarn thicknesses.