• 제목/요약/키워드: pixel density

검색결과 132건 처리시간 0.031초

슈퍼픽셀의 밀집도 및 텍스처정보를 이용한 DBSCAN기반 칼라영상분할 (A Method of Color Image Segmentation Based on DBSCAN(Density Based Spatial Clustering of Applications with Noise) Using Compactness of Superpixels and Texture Information)

  • 이정환
    • 디지털산업정보학회논문지
    • /
    • 제11권4호
    • /
    • pp.89-97
    • /
    • 2015
  • In this paper, a method of color image segmentation based on DBSCAN(Density Based Spatial Clustering of Applications with Noise) using compactness of superpixels and texture information is presented. The DBSCAN algorithm can generate clusters in large data sets by looking at the local density of data samples, using only two input parameters which called minimum number of data and distance of neighborhood data. Superpixel algorithms group pixels into perceptually meaningful atomic regions, which can be used to replace the rigid structure of the pixel grid. Each superpixel is consist of pixels with similar features such as luminance, color, textures etc. Superpixels are more efficient than pixels in case of large scale image processing. In this paper, superpixels are generated by SLIC(simple linear iterative clustering) as known popular. Superpixel characteristics are described by compactness, uniformity, boundary precision and recall. The compactness is important features to depict superpixel characteristics. Each superpixel is represented by Lab color spaces, compactness and texture information. DBSCAN clustering method applied to these feature spaces to segment a color image. To evaluate the performance of the proposed method, computer simulation is carried out to several outdoor images. The experimental results show that the proposed algorithm can provide good segmentation results on various images.

DCT와 정보 화소 밀도를 이용한 PDA로 획득한 명함 영상에서의 영역 해석 (Region Analysis of Business Card Images Acquired in PDA Using DCT and Information Pixel Density)

  • 김종흔;장익훈;김남철
    • 한국통신학회논문지
    • /
    • 제29권8C호
    • /
    • pp.1159-1174
    • /
    • 2004
  • 본 논문에서는 PDA에 장착된 카메라를 사용하여 획득한 명함 영상에 대한 효율적인 영역 해석 알고리듬을 제안한다. 제안된 방법은 크게 영역 분할, 정보 영역 분류, 문자 영역 분류의 3개 과정으로 구성된다. 영역 분할에서는 입력 명함 영상을 8${\times}$8 크기의 블록으로 나누고 각 블록을 저주파 대역에서의 정규화 된 DCT 계수의 에너지를 이용하여 정보 블록과 배경 블록으로 분류한 다음, 블록에 대한 영역 라벨링을 통하여 정보 영역과 배경 영역으로 분할한다. 정보 영역 분류에서는 각 정보 영역을 블록 신호의 수평, 수직 방향 에지 성분과 저주파 대역에서의 DCT 계수의 에너지 비와 이진화 된 정보 영역 내에서의 흑화소인 정보 화소의 밀도를 이용하여 문자 영역과 배경 영역으로 분류한다. 문자 영역 분류에서는 분류된 문자 영역을 정보 화소의 밀도와 평균 런 길이를 이용하여 다시 큰 문자와 작은 문자 영역으로 분류한다. 실험결과 제안된 영역 해석 방법은 여러 종류의 명함을 다양한 주변 여건에서 PDA로 획득한 시험 영상에 대하여 정보 영역과 배경 영역을 잘 분할하고, 정보 영역을 문자 영역과 그림 영역으로 잘 분류하며, 다시 문자 영역을 큰 문자와 작은 문자 영역으로 잘 분류함을 보였다 그리고 제안된 영역 분할 방법과 정보 영역 분류 방법은 기존의 방법들보다 각각 약 2.2-10.1%와 7.7%의 에러율 향상을 보였다.

영상 평활화를 위한 화소-병렬 영상처리 시스템에 관한 연구 (A Study on the Pixel-Paralled Image Processing System for Image Smoothing)

  • 김현기;이천희
    • 대한전자공학회논문지SD
    • /
    • 제39권11호
    • /
    • pp.24-32
    • /
    • 2002
  • 본 논문에서는 포맷 변환기를 사용하여 여러 가지 영상처리 필터링을 구현하였다. 이러한 설계 기법은 집적회로를 이용한 대규모 화소처리배열을 근거로 하여 실현하였다. 집적구조의 두가지 형태는 연산병렬프로세서와 병렬 프로세스 DRAM(또는 SRAM) 셀로 분류할 수 있다. 1비트 논리의 설게 피치는 집적 구조에서의 고밀도 PE를 배열하기 위한 메모리 셀 피치와 동일하다. 이러한 포맷 변환기 설계는 효율적인 제어 경로 수행을 능력을 가지고 있으며 하드웨어를 복잡하게 할 필요 없이 고급 기술로 사용 될 수 있다. 배열 명령어의 순차는 프로세스가 시작되기 전에 호스트 컴퓨터에 의해 생성이 되며 명령은 유니트 제어기에 저장이 된다. 호스트 컴퓨터는 프로세싱이 시작된 후에 저장된 명령어위치에서 시작하여 화소-병렬 동작을 처리하게 된다. 실험 결과 1)단순한 평활화는 더 높은 공간의 주파수를 억제하면서 잡음을 감소시킬 뿐 아니라 에지를 흐리게 할 수 있으며, 2) 평활화와 분할 과정은 날카로운 에지를 보존하면서 잡음을 감소시키고, 3) 평활화와 분할과 같은 메디안 필터링기법은 영상 잡음을 줄이기 위해 적용될 수 있고 날카로운 에지는 유지하면서 스파이크 성분을 제거하고 화소 값에서 단조로운 변화를 유지 할 수 있었다.

치근단낭과 육아종의 디지털방사선학적 비교연구 (Comparison of Digital Radiometric Features between Radicular Cysts and Periapical Granulomas)

  • 진연화;이건일
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.241-254
    • /
    • 1999
  • The purpose of this study was to investigate whether a radiometric analysis of radicular cysts and periapical granulomas is useful in the differential diagnosis. In this experiment, twenty-nine periapical radiographs of the radicular cyst and those periapical granuloma were used. The periapical radiography was taken by intraoral paralleling device. The X-ray film was digitized and digitally filtered to reduce film-grain noise. We estimated density difference of the inner/outer area, roundness or circularity, bone profile or scan line of the margin and cumulative percentage frequency curve of radicular cyst & periapical granuloma. The obtained results were as follows; 1. The differences in density between ROIs of inner and outer area of radicular cysts were smaller than those of periapical granulomas. 2. The equivalent circular diameter was over 6.3mm, there was significant difference between periapical cyst and periapical granuloma. 3. In differential diagnosis of radicular cyst and periapical granuloma using bone profile. sensitivity. specificity and accuracy were considerably high(0.83. 0.86. 0.86) respectively. 4. Cumulative percentage frequency curve of the radicular cyst was closer to the pseudo-pixel value of 50 than average curve, whereas periapical granuloma was closer to that of 0. Hence we conclude that digital radiometric features might be useful in the differential diagnosis between radicular cyst and periapical granuloma.

  • PDF

디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구 (Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector)

  • 김병기;김상건;차선화;최준구;이준;이민우;김순배;김경수
    • 대한디지털의료영상학회논문지
    • /
    • 제9권2호
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가 (A comparative study for resolution and density of chest imaging using film/screen, CR and DR)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제4권1호
    • /
    • pp.25-30
    • /
    • 2010
  • 이 연구 목적은 흉부영상의 진단에 적절한 해상력과 음영에 대한 적절한 평가를 위해서다. 해상력을 비교하기 위해서, linear 해상력 팬텀을 사용하여 film/screen(선생님이 원하시는 conventional radiography : film/screen), CR, DR, 촬영했다. 해상력을 비교하기 위해 2명의 영상의학과 전문의와 3명의 방사선사가 블라인드 테스트를 통하여 평가했다. DR 은 3.95 필름/ 스크린은 3.58, CR은 3.48의 평가가 나왔다. 음영에 대해 분석은, CR, DR의 film/screen의 정상적인 흉부영상 50장을 선택했다. 이 흉부영상에서 7부위(폐야, 폐야 윤곽, 종격동 I, 종격동 II, 심장 음영 I, 심장음영 II, 횡격막)을 정하여 덴시토미터(농도계)을 사용하여 음영을 평가했다. 우리의 분석 방법은 낮은 영상(음영)을 0에서부터 가장 우수한 영상(음영) 2를 정한 일본의 흉부 x-ray 평가 방법을 적용했다. DR의 경우 종격동 1, 종격동2, 심장 1, 심장2, 횡격막에서 2점을 기록하여 우수했다. 이와 반대로 CR에서는 폐부위와 폐음영 부위에서 2점으로 우수했다. 결론적으로, 해상력과 음영에 비교하면 후처리 알고리즘과 작은 픽셀 사이즈에 의한 DR은 CR과 film/screen 보다 우수하다고 도출하였다.

470 x 235ppi poly-Si TFT LCD for High-Resolution 2D and 3D Autostereoscopic Display

  • Uehara, Shin-Ichi;Ikeda, Naoyasu;Takanashi, Nobuaki;Iriguchi, Masao;Sugimoto, Mitsuhiro;Matsuzaki, Tadahiro;Asada, Hideki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.783-786
    • /
    • 2004
  • We have developed a 470 x 235ppi poly-Si TFT LCD with a novel pixel arrangement, called HDDP (Horizontally Double-Density Pixels), for high-resolution 2D and 3D autostereoscopic display. 3D image quality is especially high in a lenticular-lens-equipped 3D mode because both horizontal resolution and vertical resolution are high, and because these resolutions are equal. 3D and 2D images can be displayed simultaneously in the same picture. In addition, 3D images can be displayed anywhere and 2D characters can be made to appear at different depths with perfect legibility. No switching of 2D/3D modes is necessary, and the design's thin and uncomplicated structure makes it especially suitable for mobile terminals.

  • PDF

Development of 200ppi SOG-LCD

  • Kim, Chul-Ho;Kim, Chul-Min;Moon, Kook-Chul;Park, Kee-Chan;Kim, Il-Gon;Joo, Sueng-Yong;Park, Tae-Hyeong;Maeng, Ho-Suk;Jung, Eu-Jin;Kim, Chi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.85-88
    • /
    • 2004
  • 2-inch qVGA (240${\times}$320) TFT-LCD with integrated 6-bit source driver is reported. The pixel density is over than 200ppi and the operation frequency is about 2.8MHz. In order to improve TFT characteristics, TS-SLS (Two-Shot Sequential Lateral Solidification) technology has been employed. A 1:6 demultiplexing scheme has been successfully implemented in the source driver owing to the superb characteristics of the TS-SLS TFTs, which resulted in small driver circuit area.

  • PDF

Error-Correcting 7/9 Modulation Codes For Holographic Data Storage

  • Lee, Kyoungoh;Kim, Byungsun;Lee, Jaejin
    • 한국통신학회논문지
    • /
    • 제39A권2호
    • /
    • pp.86-91
    • /
    • 2014
  • Holographic data storage (HDS) has a number of advantages, including a high transmission rate through the use of a charge coupled device array for reading two-dimensional (2D) pixel image data, and a high density capacity. HDS also has disadvantages, including 2d intersymbol interference by neighboring pixels and interpage interference by multiple pages stored in the same holographic volume. These problems can be eliminated by modulation codes. We propose a 7/9 error-correcting modulation code that exploits a Viterbi-trellis algorithm and has a code rate larger (about 0.778) than that of the conventional 6/8 balanced modulation code. We show improved performance of the bit error rate with the proposed scheme compared to that of the simple 7/9 code without the trellis scheme and the 6/8 balanced modulation code.

구조물 내벽의 균열 검사를 위한 시스템 개발에 관한 연구 (A Study on the Development of the System for Inspecting Cracks in the Inner Wall for Structures)

  • 이상호;신동익;손영갑;이강문;마상준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.480-483
    • /
    • 1997
  • In this paper, we have proposed an automatic inspection system for cracks on the surface of a structure. The proposed system consists of the imaging system and the veh~cle system. The imaging system. a set of optical sensor, lens, illuminator, storage and their configuration, images the scene and store it on the hard disk. We adopted a linescan camera of 5000 pixel density to achieve high resolution without loss of simplicity. The vehicle system that moves the optical system IS ~mplemented by an AGV. The AGV moves forward at constant velocity and avoid obstacles to acquire a stable image. We have cmplemented an experimental system and have acquired images of the wall of hallway. The image is of 0.1-mmipixel resolution and the scanning time IS about 1 mlsec. The allow able scan.

  • PDF