• Title/Summary/Keyword: pitch noise

Search Result 286, Processing Time 0.027 seconds

A Study on the Flying Stability of Optical Flying Head on the Plastic Disks (플라스틱 디스크상의 부상형 광헤드의 부상안정성에 관한 연구)

  • Kim, Soo-Kyung;Yoon, Sang-Joon;Choi, Dong-Hoon;Lee, Seung-Yop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.399-402
    • /
    • 2004
  • In the optical drive system, adopting the optical flying-type head (OFH) flying on a removable plastic disk, the flying stability of the small OFH should be carefully considered to ensure the reliability for first surface recording. Additional micro actuators for focus servo are discussed for better interface of optical flying head on thin cover layered plastic disk to eliminate focus error due to the non-uniformity of cover layer thickness and the tolerance of lens assembly. This study gives two simulation results on the flying stability of the OFH. One is the dependence of the flying height and pitch angle variations on the wavelength and amplitude of disk waviness. The other is the flying stability of the slider and suspension system during the dynamic load/unload (U/UL) process.

  • PDF

Empirical Modeling of the Global Distribution of Magnetosonic Waves with Ambient Plasma Environment using Van Allen Probes

  • Kim, Kyung-Chan
    • Journal of Astronomy and Space Sciences
    • /
    • v.39 no.1
    • /
    • pp.11-22
    • /
    • 2022
  • It is suggested that magnetosonic waves (also known as equatorial noise) can scatter radiation belt electrons in the Earth's magnetosphere. Therefore, it is important to understand the global distribution of these waves between the proton cyclotron frequency and the lower hybrid resonance frequency. In this study, we developed an empirical model for estimating the global distribution of magnetosonic wave amplitudes and wave normal angles. The model is based on the entire mission period (approximately 2012-2019) of observations of Van Allen Probes A and B as a function of the distance from the Earth (denoted by L*), magnetic local time (MLT), magnetic latitude (λ), and geomagnetic activity (denoted by the Kp index). In previous studies the wave distribution inside and outside the plasmasphere were separately investigated and modeled. Our model, on the other hand, identifies the wave distribution along with the ambient plasma environment-defined by the ratio of the plasma frequency (fpe) to the electron cyclotron frequency (fce)-without separately determining the wave distribution according to the plasmapause location. The model results show that, as Kp increases, the dayside wave amplitude in the equatorial region intensifies. It thereby propagates the intense region towards the wider MLT and inward to L* < 4. In contrast, the fpe/fce ratio decreases with increasing Kp for all regions. Nevertheless, the decreasing aspect differs between regions above and below L* = 4. This finding implies that the particle energy and pitch angle that magnetosonic waves can effectively scatter vary depending on the locations and geomagnetic activity. Our model agrees with the statistically observed wave distribution and ambient plasma environment with a coefficient of determination of > 0.9. The model is valid in all MLTs, 2 ≤ L* < 6, |λ| < 20°, and Kp ≤ 6.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Comparison of acoustic features due to the Lombard effect in typically developing children and adults (롬바르드 효과가 아동과 성인의 말소리 산출에 미치는 영향: 음향학적 특성과 모음공간면적을 중심으로)

  • Yelim Jang;Jaehee Hwang;Nuri Lee;Nakyung Lee;Seeun Eum;Youngmee Lee
    • Phonetics and Speech Sciences
    • /
    • v.16 no.2
    • /
    • pp.19-27
    • /
    • 2024
  • The Lombard effect is an involuntary response to speakers' experiences in the presence of noise during voice communication. This study aimed to investigate the Lombard effect by comparing the acoustic features of children and adults under different listening conditions. Twelve male children (5-9 years old) and 12 young adult men (24-35 years old) were recruited to produce speech under three different listening conditions (quiet, noise-55 dB, noise-70 dB). Acoustic analyses were then carried out to characterize their acoustic features, such as F0, intensity, duration, and vowel space area, under the three listening conditions. A Lombard effect was observed in the intensity and duration for children and adults who participated in this study under adverse listening conditions. However, we did not observe a Lombard effect in the F0 and vowel space areas of either group. These findings suggest that children can adjust their speech production in challenging listening conditions as much as adults.

Objective Measures of Voice Production in Telephone Operators (교환수들의 음성발성에 대한 평가)

  • 진성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.38-43
    • /
    • 1997
  • Backgroud : Now a days, most studies for professional voice user have been performed after artificial voice abuse without consideration of environmental and personal factors, and occupational specificity, therefore those studies have some problems. Objectives : To make a basic guideline for the management of untrained professional voice user, practically we ananalyzed the voice of experimental group. Materials and methods : Just after working, the sustained vowel sounds of the 15 female telephone operators (subjective group) and the 20 normal female persons (control group) were analysed, using a history paper, acoustic analyzer and videostroboscopy. Results : The most common symptom in subjective group was dysphonia. Stroboscopic findings in subjective group were as following ; posterior chink 11 cases (73%), incomplete closure 2 cases (13%), anterior chink 1 case (7%). The mean maximal phonation time in telephone operators was 12.8 seconds and in control group was 16.8 seconds. Jitter, pitch pertubation quotient (PPQ), shimmer and amplitude pertubation quotient (ASQ) were significantly increased in subjective group than control group, but there is no difference between two group in fundamental frequency and noise to harmonic ratio. Conclusion : Untrained professional voice user needs professional career guidance and counseling. And when we manage the untrained professional voice user, we should consider specific occupational, personal and environmental factors as well as laryngeal factors.

  • PDF

A Study on the Effect of the Honing in SCM420H Planetary Gear (SCM420H 유성기어의 호닝효과에 관한 연구)

  • An, In-Hyo;Ahn, Min-Ju;Xu, Zhezhu;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.13-18
    • /
    • 2011
  • This study deals with the effect of the honing in SCM420H planetary gears. The hardness, tooth profile, lead and roughness of the gear surface can be improved by honing. Therein, the honing techniques are welcomed especially as one of the physical surface improvement methods. As a result, gear honing reduces vibration and noise, and will increase the life of gear. And gear honing also changes the surface of gear tooth in a short time and price, so it is a very important method in manufacturing industry. But nowadays, it is hard to find the detail information of gear honing. The test gear is a planetary gear which is used in the automotive industry. It is manufactured by the hobbing, shaving, carburizing and honing. This study investigates the effect of honing in surface shape of SCM420H planetary gears, including fatigue strength test and characteristics of honing of SCM420H planetary gears.

Micropositioning of a Linear Motion Table with Magnetic Bearing Suspension (자기 베어링으로 지지 되는 직선운동 테이블의 초정밀 위치제어에 관한 연구)

  • 김의석;안형준;장인배;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.466-469
    • /
    • 1995
  • This paper presents a design and performance of the 6 D.O.F linear motion table with a magnetic bearing suspension. The linear positioning of the table with a 150mm stroke is driven by a brushless DC Linear motor and the other attitudes of the stage are controlled by the analog PD controller with magnetic bearing actuators. Each magnetic bearing unit which consists of 3 electromagnets, 3 capacitance probes and 3 backup bearings affords controlled forces by detecting the air gap between the probes and guideways. An integral type capacitance probe amplifier is equipped on the upper plate of the table so that the probe line to the probe amplifier can be shorter therefore the problems due to the stray capacitance and noise can be reduced. Form the pitch-yaw errormeasured by the autocollimator, the vertical and horizont straightness errors of the table are derived that they are maintained below 1.mu. m over 100mm stroke. The positioning accuracy of the linear motion is maintained below 2 .mu. m and the repeatability error is below 1 .mu. m

  • PDF

A comparison of CPP analysis among breathiness ranks (기식 등급에 따른 CPP (Cepstral Peak Prominence) 분석 비교)

  • Kang, Youngae;Koo, Bonseok;Jo, Cheolwoo
    • Phonetics and Speech Sciences
    • /
    • v.7 no.1
    • /
    • pp.21-26
    • /
    • 2015
  • The aim of this study is to synthesize pathological breathy voice and to make a cepstral peak prominence (CPP) table following breathiness ranks by cepstral analysis to supplement reliability of the perceptual auditory judgment task. KlattGrid synthesizer included in Praat was used. Synthesis parameters consist of two groups, i.e., constants and variables. Constant parameters are pitch, amplitude, flutter, open phase, oral formant and bandwidth. Variable parameters are breathiness (BR), aspiration amplitude (AH), and spectral tilt (TL). Five hundred sixty samples of synthetic breathy vowel /a/ for male were created. Three raters participated in ranking of the breathiness. 217 were proved to be inadequate samples from perceptual judgment and cepstral analysis. Finally, 343 samples were selected. These CPP values and other related parameters from cepstral analysis are classified under four breathiness ranks (B0~B3). The mean and standard deviation of CPP is $16.10{\pm}1.15$ dB(B0), $13.68{\pm}1.34$ dB(B1), $10.97{\pm}1.41$ dB(B2), and $3.03{\pm}4.07$ dB(B3). The value of CPP decreases toward the severe group of breathiness because there is a lot of noise and a small quantity of harmonics.

A Study on Effect of the Grinding in SCM420H Planetary Gear (SCM420H 유성기어의 연삭효과에 관한 연구)

  • An, In-Hyo;Hur, Nam-Soo;Lee, In-Bum;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.54-59
    • /
    • 2012
  • This study dealt with effect of the grinding in SCM420H planetary gears. The hardness, tooth profile, lead and roughness of the gear surface can be improved by grinding process. Therein, the grinding techniques are widely used especially as one of the physical surface improvement methods. As the results, the gear grinding process reduced vibration and noise, and increased the life of the gear. And the gear grinding improved the surface of gear tooth in a short time and low cost, thus, it is a very important process in manufacturing industry. But nowadays, it is hard to find the detail information of gear grinding process. The test piece is a planetary gear which is used in the industrial machine. The manufacture process of the test piece contains hobbing, shaving, carburizing and grinding. This study investigated the effect of the grinding process to the physiognomy and the fatigue strength of test piece which was made by SCM420H.