• Title/Summary/Keyword: pipe-in-pipe

Search Result 5,793, Processing Time 0.037 seconds

A Study on the Component Design for Water Network Analysis (상수도 관망해석 컴포넌트 설계에 관한 연구)

  • Kim, Kye-Hyun;Kim, Jun-Chul;Park, Tae-Og
    • Journal of Korea Spatial Information System Society
    • /
    • v.2 no.2 s.4
    • /
    • pp.75-84
    • /
    • 2000
  • GIS has been building for various application fields with the aids of NGIS project, especially numerous municipal governments are building a UIS in the level of local governments' informatization. Although there are some difference between municipal governments' business, still many things are in common. So far, individual municipal governments have developed a UIS for their own use, which lead to duplicated development of the UIS. The component technology has been introduced to remove such duplicated efforts and it enabled maximizing the reusablilty of the UIS already developed. This paper proposes a component design for network analysis of the drinking water to calculate the amount of flow and the head loss. This component design provides the initial water amount to estimate the amount of the network flow and the head loss, thereby supports the decision making such as installation or extension of the pipe network. The process of the component design accompanies the business reengineering to support the standardized business work flow. Also, the design of the network analysis component uses the algorithms induced with UML specification. Based on the component design, the component development has been progressing and the network analysis system would be followed. In the near future, another component to integrate the network analysis and the business related to the drinking water needs to be developed.

  • PDF

LxBSM: Loadable Kernel Module for the Creation of C2 Level Audit Data based on Linux (LxBSM: C2 수준의 감사 자료 생성을 위한 리눅스 기반 동적 커널 모듈)

  • 전상훈;최재영;김세환;심원태
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.10 no.2
    • /
    • pp.146-155
    • /
    • 2004
  • Currently most of commercial operating systems contain a high-level audit feature to increase their own security level. Linux does not fall behind the other commercial operating systems in performance and stability, but Linux does not have a good audit feature. Linux is required to support a higher security feature than C2 level of the TCSEC in order to be used as a server operating system, which requires the kernel-level audit feature that provides the system call auditing feature and audit event. In this paper, we present LxBSM, which is a kernel module to provide the kernel-level audit features. The audit record format of LxBSM is compatible with that of Sunshield BSM. The LxBSM is implemented as a loadable kernel module, so it has the enhanced usability. It provides the rich audit records including the user-level audit events such as login/logout. It supports both the pipe and file interface for increasing the connectivity between LxBSM and intrusion detection systems (IDS). The performance of LxBSM is compared and evaluated with that of Linux kernel without the audit features. The response time was increased when the system calls were called to create the audit data, such as fork, execve, open, and close. However any other performance degradation was not observed.

Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape (아치형 단동온실의 지붕환기구조 및 천창효과)

  • Nam, Sang-Woon
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.99-107
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouses of arch shape. Investigation on the roof ventilation structures for those greenhouses was conducted. In small greenhouses with spans of 5 to 8 m, circular or chimney type ridge vents made of plastic were employed. In large greenhouses with spans of 12 to 18 m, even span roll-up ridge vents made of steel pipe were employed. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing ridge vents and having controlled side vents only. Roof ventilation contributed greatly to restraint of temperature rise and maintenance of uniform temperature distribution in greenhouses. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the ridge and side vent. There were no temperature differences according to opening and closing sequence of ventilation window. But for greenhouse temperature control by ventilation, it is desirable to open side vents after ridge vents and to close ridge vents after side vents.

  • PDF

Effects of the Remanent Magnetization on Detecting Signals in Magnetic Flux Leakage System (자기누설탐상시스템에서 배관의 잔류자화가 결함신호에 미치는 영향)

  • Seo, Kang;Jeong, Hyun-Won;Park, Gwan-Soo;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.325-331
    • /
    • 2005
  • The magnetic Hut leakage (MFL) type nondestructive testing (NDT) method is widely used to detect corrosion and defects, mechanical deformation of the underground gas pipelines. The object pipeline is magnetically saturated by the magnetic system with permanent magnet and yokes. Because of the strong magnetic field enough to saturate the pipe, there could be distortion of the sensing signals because of the magnetization of the pipeline itself, To detect the defects precisely, the sensing signals are need to be compensated to eliminate the distortions coming from the media hysteresis. In this paper, the magnetizations of the pipeline in MFL type NDT are analyzed by Preisach model and 3D FEM. The distortions of the sensing signals are analyzed.

Development of a System Dynamics Model for the Efficient Operation and Maintenance of Sewerage Systems (하수도 시스템의 효율적인 운영 및 유지관리를 위한 시스템다이내믹스 모형의 개발)

  • Park, Su-Wan;Lee, Tae-Geun;Kim, Bong-Jae;Kim, Tae-Young
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.101-111
    • /
    • 2012
  • In this paper, the feedback loop mechanisms among the operational indices and exogenous variables of a sewerage system that are inherent in the operation and maintenance of a sewerage system were identified using the System Dynamics (SD) modeling methodology. The identified feedback loops were used to develop a SD computer simulation model that can be used to predict future operational conditions of a sewerage system and identified the efficient ways of operation. The data of Busan metropolitan city sewerage system was applied to verify the developed SD model and predict future operational conditions of the system. As a result, it was predicted that sewage treatment efficiency, volume of sewage treatment and cost recovery rate will be gradually increased, whereas service rate which was already very close to the target will remain almost the same as the current value. Furthermore, sensitivity analysis concerning some operational indices was performed in order to discover the policy leverage. As a result, it was found that the exogenous variables related to the pipe maintenance had a great effect on facility using rate, volume of sewage treatment as well as sewage treatment efficiency.

Development of the computer program calculating the stress induced by various loads for buried natural gas pipeline ( I ) (매설 천연가스 배관의 제반하중에 의한 응력 계산용 프로그램 개발 (I))

  • Bang I.W.;Kim H.S.;Kim W.S.;Yang Y.C.;Oh K.W.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.2
    • /
    • pp.18-25
    • /
    • 1998
  • According to the requirements of ANSI B3l.8, the pipe thickness is determined with hoop stress resulted from internal pressure. And the other loads induced by soil, vehicle, thermal expansion, ground subsidence, etc shall be evaluated rationally. There are two ways of calculating stress of buried gas pipeline. The first is FEM. FEM can calculate the stress regardless of the complexity of pipeline shape and boundary conditions. But it needs high cost and long time. The second is the way to use equation. The reliable equations to calculate the stress of buried gas pipeline was developed and have been used in designing pipeline and evaluating pipeline safety, But these equation are very difficult to understand and use for non-specialist. For easy calculation of non-specialist, the new computer program to calculate stress of buried natural gas pipeline have been developed. The stress is calculated by the equations and extrapolation of the graph resulted from FEM. The full paper is consist of series I and II. In this paper, series I, the calculating equation of the program is explained in detail.

  • PDF

The Effect of Internal Row on Marine Riser Dynamics (Riser의 내부유체 흐름이 Riser 동적반응에 미치는 영향)

  • Hong, Nam-Seeg
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.1
    • /
    • pp.75-90
    • /
    • 1995
  • A mathematical model for the dynamic analysis of a riser system with the inclusion of internal flow and nonlinear effects due to large structural displacements is developed to investigate the effect of internal flow on marine riser dynamics. The riser system accounts fir the nonlinear boundary conditions and includes a steady flow inside the pipe which is modeled as an extensible or inextensible. tubular beam subject to nonlinear three dimensional hydrodynamic loads such as current or wave excitation. Galerkin's finite element approximation and time incremental operator are implemented to derive the matrix equation of equilibrium for the finite element system and the extensibility or inextensibility condition is used to reduce degree of freedom of the system and the required computational time in the case of a nonlinear model. The algorithm is implemented to develop computer programs used in several numerical applications. The investigations of the effect of infernal flow on riser vibration due to current or wave loading are performed according to the change of various parameters such as top tension, internal flow velocity, current velocity, wave period, and so on. It is found that the effect of internal flow can be controlled by the increase of top tension. However, careful consideration has to be given in the design point particularly for the long riser under the harmonic loading such as waves. And it is also found that the consideration of nonlinear effects due to large structural displacements increases the effect of internal flow on riser dynamics.

  • PDF

A Study on the Thermal Decomposition and Injection Direction of Urea Solution Used in DeNOx Process (탈질공정에 사용되는 우레아 수용액의 열분해와 분사방향에 관한 연구)

  • Moon, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.531-540
    • /
    • 2009
  • In this study, thermo-gravimetric analysis(TGA) was used to investigate the effect of urea concentration and heating rate on the ammonia($NH_3$) formation process from urea solution. A newly designed pipe nozzle was inserted through a 1,000 N${\ss}$(C)/h oil firing boiler to compare the DeNOx efficiencies between the upward and downward nozzle. This experiment reveals the effect of path which an urea droplet goes through. Urea solution showed the same TGA graph without regard to the presence of oxygen. Heating rate had a great influence on the weight loss trend. But the concentration of urea solution between 10% and 40% did not affect so much the thermal decomposition temperature. Therefore, heating rate is more important factor on the thermal decomposition of urea than the concentration of urea solution. Three nozzles located at different positions showed similar DeNOx efficiencies such as 68.1%, 71.8%, 70.8% at the same temperature. Even though urea solution was injected for the same zone, the injection direction made much difference in DeNOx efficiency. A upward nozzle showed 68.1% and downward nozzle 9.5%. This results illustrate the importance of heating rate.

Composting Effectiveness of A Sundry System with A Bin-type Composter for Recyle of Animal Wastes (축분뇨처리를 위한 Bin형 부숙조- Sundry 시스템의 퇴비화효율 평가)

  • 최홍림;김현태;정영윤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.92-103
    • /
    • 1993
  • A sunday system with a horizontal bin-type composter was constructed and operated to evaluate its composting performance for four days for each test in October, 1992. A sundry system is one of popular systems for composting livestock manure, of which main benefit is to utilize unlimited, clean, and free solar radiation. A rectangular concrete bin(composter) with dimension of 300cm(length) X90cm(width) X60cm(height) was bedded alternatively with four lanes of aeration pipes and heating pipes, and was insulated at three walls with 50mm styrofoam. Each aeration pipe of a diameter of 25mm had 4mm perforated holes at every 15cm longitudinally, and supplied air of about 2m$^3$/min to the composter to maintain aerobic condition . A stirrer rotating at 1 rpm made one round trip every 20 minutes on the conveying chain along the the length of the composter. Five tests (Test 1~Test 5) were implemented to evaluate the composting effectiveness of a sundry system with a horizontal bin-type composter. Treatments of two levels of the mixture ratio of swine manure and paper sludge cakes(manure : paper sludge cakes= 1 : 4 and 1 : 2) and two levels of the water content(W/C ; 70% and 50%) were made to test the significance of the physicochemical properties for decomposition of the mixture materials. Temperature, C/N ratio, water content, microbial activity of the composting materials were taken measurements to evaluate its performance with the lapse of composting time for tests. A small-scale sundry system with a bin-type composter did not appear to be an appropriate system for composting livestock manure. Since heat generation by the composting materials could not overcome heat loss due to areation in a small-scale composter, a proper thermal enviroment could not be maintained to propagate massively thermopilic microorganism relatively in a short period of time. Different from the result of Chol et al.(1992) 6), a temperature variation of the composting materials did not show the peak clearly and C/N ratio didn't lower with time as expected. Mesophilic microoragnism seemed to play an important role for decomposition of the mixture materials. A sundry system with a bin-type composter may be good for a large-scale livestock farm household which may produce enough animal manure. Therefore a decision should be made very carefully to choose a system for composting livestock waste.

  • PDF

Suggestions for Safety Improvement of CNG Bus Based on Accident and Failure Analysis (CNG버스 사고원인 분석에 근거한 안전성 향상 방안에 대한 연구)

  • Yoon, Jae-Kun;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.69-76
    • /
    • 2008
  • Three failure cases of CNG composite vessels were reported since after January 2005. The 1st and 2nd accidents were indebted to vessel defect and installation mistake. The 3rd was caused by gas leak at pipe connections. In this paper various aspects were studied based on information of the three failure analysis, which must be improved for better safety of the CNG bus system. Overpressure region caused by vessel explosion was theoretically predicted and also assessed by PHAST program. Explosion of 120 l vessel under 20 MPa is equivalent to 1.2 kg TNT explosion. The predicted value by PHAST was more serious than theoretical one. However, actual consequence of explosion was much less than both of the predicted consequences. Since the CNG vessel was designed by the performance based design methodology, it is difficult to verify whether the required process and tests were properly conducted or not after production. If material toughness is not enough, the vessel should be weak in brittle fracture at early in the morning of winter season since the metal temperature can be lower than the transition temperature. If autofrettage pressure is not correct, fatigue failure due to tensile stress during repeated charging is possible. One positive aspect is that fire did not ocurred after vessel failure. This may be indebted to fast diffusion of natural gas which hindered starting fire.

  • PDF