• 제목/요약/키워드: pipe installation

검색결과 263건 처리시간 0.025초

동일한 전극 표면적에서 DBD방전형 내부전극 형상에 따른 오존생성특성 연구 (Ozone Production Characteristics of the DBD Discharge the Electrode Shape at the Same Electrode surface area)

  • 권영학;박현미;송현직;박원주
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.71-77
    • /
    • 2016
  • The dielectric barrier discharge (DBD) has low efficiency due to about 70% input power is consumed as thermal energy in the discharge space. However, because of the usage of DBD ozone generator is easier than other methods. The DBD ozone generator has been widely applied for high concentration ozone generation in the industrial application. But, the low-capacity compact DBD ozone generator is not applied so far. Therefore, the DBD ozone generator is necessary to improve ozone production efficiency and reduce the capacity. In this paper, the stainless steel pipe inner electrode was designed with hall type and screw type to improve the ozone production yield. The manufactured two inner electrodes were experimented with normal type for comparison of the discharge characteristics and the ozone generating characteristics. As the experimental results, the discharge current effective value of designed inner electrodes with hall type and screw type are higher than the normal type, due to unequal electric field is formed at the boundary. However, the difference of designed and original electrodes is less than 0.1mA that has no effect on the discharge characteristic. On the other hand, the screw type inner electrode increased higher than original model about 7 times when the flow rate of the oxygen source gas was increased from $0.6{\ell}/min$ to $1.0{\ell}/min$ The reason was assumed by the flow rate of the raw gas through the inner electrode was became fast that has a cooling effect. The designed hall type and screw type inner electrodes have shown good performances in ozone generation and ozone production that better than normal type in the same electrode surface area.

네팔 Modi Khola 수력발전소 수리모형실험 연구 (A Study on the Hydraulic Experiments of Modi Khola Hydroelectric in Nepal)

  • 선우중호;박창근
    • 물과 미래
    • /
    • 제28권1호
    • /
    • pp.107-120
    • /
    • 1995
  • 본 연구는 네팔의 Modi Khola 강 유역에 건설되는 Modi Khola 수력발전소의 취수구 구조물 및 침사지 구조물에 대한 수리모형실험 연구이다. 취수구 구조물은 축척이 1:20인 정상모형으로, 침사지 구조물은 수직방향 축척이 1:10, 수평방향 축척이 1:15인 왜곡모형으로 제작되었다. 본 실험에서는 이동상 모형이론에 의해 'Anthracite'($\rho_s$ =1.48)를 모형사로 선택하였다. 실험결과 취수구 구조물 부분에서는 세사영역의 유사퇴적을 막기 위해 적정한 높이의 guide wall 설치가 바람직하며, 효율적 배사를 위해 배사수문의 적절한 조작이 필요한 것으로 나타났다. 침사지 구조물 부분에서는 효율적인 침사를 위해 침사지내의 난류호흡을 억제시키는 설계가 요구되었고, 침사지내 퇴사를 처리하기 위하여 설치된 유출구측의 배사 파이프는 침사지 전영역의 배사를 효율적으로 수행하지 못하였으므로 최대 퇴사가 발생하는 지점 근처에 추가로 배사 파이프를 설치하는 것이 바람직하다. 또한 침사효율은 평균 약 95%로 관측되었는데, 비교적 좋은 침사지 설계라 판단된다.

  • PDF

도시유역의 물순환 및 수질 개선을 위한 저영향개발 시설의 비용 효율 분석 (Cost-Effectiveness Analysis of Low-Impact Development Facilities to Improve Hydrologic Cycle and Water Quality in Urban Watershed)

  • 최정현;김경민;심인경;이옥정;김상단
    • 한국물환경학회지
    • /
    • 제36권3호
    • /
    • pp.206-219
    • /
    • 2020
  • As urbanization and impermeable areas have increased, stormwater and non-point pollutants entering the stream have increased. Additionally, in the case of the old town comprising a combined sewer pipe system, there is a problem of stream water pollution caused by the combined sewer overflow. To resolve this problem, many cities globally are pursuing an environmentally friendly low impact development strategy that can infiltrate, evaporate, and store rainwater. This study analyzed the expected effects and efficiency when the LID facility was installed as a measure to improve hydrologic cycle and water quality in the Oncheon stream in Busan. The EPA-SWMM, previously calibrated for hydrological and water quality parameters, was used, and standard parameters of the LID facilities supported by the EPA-SWMM were set. Benchmarking the green infrastructure plan in New York City, USA, has created various installation scenarios for the LID facilities in the Oncheon stream drainage area. The installation and maintenance cost of the LID facility for scenarios were estimated, and the effect of each LID facility was analyzed through a long-term EPA-SWMM simulation. Among the applied LID facilities, the infiltration trench showed the best effect, and the bio-retention cell and permeable pavement system followed. Conversely, in terms of cost-efficiency, the permeable pavement systems showed the best efficiency, followed by the infiltration trenches and bio-retention cells.

Study on System Support for Offshore Plant Piping Process Using 3D Simulator

  • Kim, Hyun-Cheol;Lee, Gyu-Hong
    • 한국해양공학회지
    • /
    • 제34권3호
    • /
    • pp.217-226
    • /
    • 2020
  • An offshore plant is an offshore platform that can process oil and gas resources in rough seas with a poor working environment. Moreover, it is a complex structure with different types of offshore facilities and a large amount of outfitting that connects different offshore installations. In particular, an enormous amount of various piping materials is installed in a relatively narrow space, and thus, the difficulty of working is relatively high compared to working in ships or ground plants. Generally, when the 3D detailed design is completed, an offshore plant piping process is carried out at the shipyard with ISO 2D fabrication drawings and ISO 2D installation drawings. If a worker wants to understand the three-dimensional piping composition in the working area, he can only use three-dimensional viewers that provide limited functionality. As offshore plant construction progresses, correlating work with predecessors becomes more complicated and rework occurs because of frequent design changes. This viewer function makes it difficult to identify the 3D piping structure of the urgently needed part. This study deals with the process support method based on a system using a 3D simulator to improve the efficiency of the piping process. The 3D simulator is based on the Unity3D engine and can be simulated by considering the classification and priority of 3D models by the piping process in the system. Further, it makes it possible to visualize progress information of the process. In addition, the punch content can be displayed on the 3D model after the pipe inspection. Finally, in supporting the data in relation to the piping process, it is considered that 3D-simulator-supported piping installing could improve the work efficiency by more than 99% compared to the existing method.

폐열에너지를 활용한 친환경건조시스템 개발 (Development of Green Drying System Using Waste Heat from Charcoal Kiln)

  • 권구중;권성민;장재혁;황원중;김남훈
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권6호
    • /
    • pp.512-520
    • /
    • 2011
  • 본 연구에서는 탄화과정 중에 탄화로에서 발생되는 폐열을 활용하기 위해서 친환경건조시스템을 개발하여 그 특성을 검토하였다. 친환경건조시스템은 화석연료를 전혀 이용하고 있지 않고, 버려지는 폐열을 이용하기 때문에 환경친화적이다. 친환경건조시스템의 열원으로 이용되는 열수는 3개의 탄화로에 서로 연결되어 폐열을 회수하고 있고, 지속적인 열원의 공급으로 건조기내의 온도와 습도변화는 크지 않았다. 친환경건조시스템 설치가 목탄의 특성에 미치는 영향을 조사하기 위하여 고정탄소, 정련도, 경도, 발열량, pH, 단위중량당 발열량, 수탄율을 분석하였다. 그 결과로부터 친환경건조시스템 설치가 목탄의 특성에 크게 영향을 주지 않는 것으로 나타났다. 따라서 버려지는 폐열을 회수하여 에너지로 이용하는 친환경건조시스템은 에너지절감과 농산물의 건조품질을 향상시켜 농가의 수익을 극대화할 수 있는 효과가 있을 것으로 생각된다.

건축물에 시설되는 수변전설비 내진설계 방안 (The Plan on the Seismic Design of Electrical Facility Installed in the Building)

  • 김기현;이상익;배석명;조성국
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.89-95
    • /
    • 2009
  • 최근 한반도 주변국인 일본, 중국 등에서 크고 작은 지진 발생으로 많은 인명 및 재산 피해가 발생함에 따라 국내에서도 지진발생 추이 및 지진 피해 등 지진위험에 대한 관심이 높아지고 있다. 본 논문은 지진 발생시 건축물에서 위급상황에 대한 대처 및 여러 가지 구제 활동에 필수적인 전원공급 장치인 수변전실의 전기설비 지진 대책에 관하여 국내 현황 및 문제점을 분석하였다. 또한 국내 건축구조설계 기준과 일본의 건축전기설비 내진 설계시공 매뉴얼을 참조하여 건축물 내에 시설되는 수변전설비의 내진 설계 방향을 제시하였다. 본 논문은 전기기기 및 배관 설비 별 상세 설계 방법 제시와 설계 및 시공에 대한 신뢰성 검증을 위한 검사 기준 제시에 적용될 수 있을 것으로 사료된다.

상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석 (Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline)

  • 이호현;홍성택
    • 한국정보통신학회논문지
    • /
    • 제25권6호
    • /
    • pp.834-840
    • /
    • 2021
  • 먹는 물을 생산하여 공급하는 상수도 관로에 있어서 압력계에 대한 설치와 관리 방안이 미비함에 따라 압력데이터 신뢰성의 확보 및 운영관리의 어려움을 겪고 있는 실정이다. 관망 및 펌프 등 운영관리 효율화 및 SWM(Smart Water Management)을 구현하기 위해서는 하부 계측 센서의 정확한 데이터 취득을 통하여 의사결정이 이루어져야 한다. 따라서, 본 연구에서는 게이트 밸브와 버터플라이 밸브를 중심으로 관로의 직경(D)을 기준으로 전단 -3D에서부터 후단 7D까지 압력계를 설치하여 밸브의 개도율을 조절하며 데이터를 취득하는 직관 거리 시험을 실시하였으며, 관로에 수직으로 상단(180°)부터 하단(0°)까지 45° 각도 간격으로 압력계를 설치한 후 수직 위치 시험을 실시하였으며, 이 결과들을 바탕으로 압력계의 최적 위치선정 방안을 제시하고자 한다.

현장 실험을 통한 원형강관 석션관입성 검토 (Suction Penetration Review of Circular Steel Pipes by Field Test)

  • 김현주;최진오
    • 한국지반공학회논문집
    • /
    • 제36권12호
    • /
    • pp.35-43
    • /
    • 2020
  • 현재 국내에서 하천/해상 교량 공사시 교량기초 설치를 위한 가시설로서 원형 단면의 가물막이(cofferdam)를 많이 적용하고 있다. 기존 케이슨(caisson), 시트파일(sheet pile), 셀(cell) 식 등의 가물막이 공법이 많이 활용되고 있으나 이러한 공법은 설치 및 해체시 많은 시간과 비용이 소요된다. 해상공사에서 가장 보편적으로 사용되고 있는 시트파일 공법의 경우 지반 관입에 의한 시트파일 손상과 요소 부재 연결 작업의 어려움으로 내적 및 외적 안정성 확보를 위해 주의가 필요하다. 본 연구에서는 서해안 연약지반을 대상으로 원형강관의 석션관입성 설계를 수행하였고, 현장실험을 통하여 원형강관 석션관입 시공이 가능한 것을 확인하였다. 그리고 표준관입시험(N치) 결과보다 콘관입시험(CPTu)을 이용한 지반 분석 결과를 설계에 적용하는 것이 현장 실험 결과와 보다 유사한 결과를 나타내는 것을 확인하였다. 또한 실트질 사질토 지반에서 상한석션압 이상의 석션압을 적용시 가물막이 내부의 국부적인 파괴(piping 현상)를 유발하는 것을 확인하였다.

마르코프 연쇄 모델을 이용한 하수관로의 구조적 노후도 추정 (Estimation of Structural Deterioration of Sewer using Markov Chain Model)

  • 강병준;유순유;장전리;박규홍
    • 대한토목학회논문집
    • /
    • 제43권4호
    • /
    • pp.421-431
    • /
    • 2023
  • 하수관로 열화모델은 하수관망을 관리하는 의사결정자에게 자산의 미래 상태 예측에 대한 중요한 정보를 제공할 수 있다. 본 연구에서는 CCTV 조사를 통해서 확보한 구조적 상태평가 이력자료를 기반으로 마르코프 연쇄 모델을 이용하여 하수관로의 노후도를 추정하였다. A시의 3개 배수분구에서 1998-1999년과 2010-2011년에 CCTV 조사에 의해 수집된 관경 450 mm와 600 mm의 흄관 자료를 이용하여 분석하였다. EM 배수분구의 450 mm 관로와 600 mm 관로에서 주요 결함 발생이 다른 두 배수분구보다 빠르게 발생하는 것으로 나타났다. 관로 설치 이후 35년이 지난 시점에는 450 mm 관로의 약 29%, 600 mm 관로의 약 38%가 주요 결함이 발생했으며, 100년 후에는 각각 62%와 74%의 관로가 주요 결함으로 관로 기능을 상실하는 수준으로 나타났다. 관로설치 35년 후, SN 배수분구는 450 mm 관로의 약 26%, 600 mm 관로에서 약 35%, HK 배수분구에서는 450 mm 관로의 약 27%, 600 mm 관로에서 약 37%의 주요 결함이 발생한 것으로 예측되었다. 또한 600 mm 관로가 450 mm 관로보다 평균 12년 정도 빨리 기능 저하가 일어나는 것으로 나타났다. 한편, 관로의 주요 결함등급 비율을 40%로 설정하여 관로의 유효사용수명으로 적용할 경우, 450 mm 관로는 SN배수분구에서 60년, EM배수분구에서 42년, HK배수분구 59년이며, 600 mm 관로에서는 각각 43년, 34년 39년으로 나타났다.

배관용 보온재의 난연 성능 시험방법에 따른 최대 발열량 분석 (Analysis of the Maximum Heat Release Rate in Accordance with the Test Method of the Flame Retardant Performance for Pipe Insulation)

  • 유우준;박정욱;신연제;박형규;임옥근
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.18-25
    • /
    • 2020
  • 본 연구에서는 보온재의 설치 상태를 고려한 ISO 20632와 NFPA 274 시험 기준에 따른 발열량 산출 결과를 분석하였다. 이를 위해서 보온재 총 6종(은박 발포폴리에틸렌(PE(S)), 무은박 발포폴리에틸렌폼(PE(N)), 고무발포(Rubber), 일본-폴리에틸렌폼(PE(J)), 일본-폴리우레탄폼(PU(J)) 그리고 일본-스티로폼(ST(J)))에 대해서 EN 13501-1과 화재성장곡선에 따른 난연 등급을 구분하였다. 그 결과 PU(J), PE(J) 그리고 PE(N)는 Class E 및 Ultra-fast, NFPA 274 시험기준에 의한 PE(S)는 Class D 및 Fast, ISO 20632에 의한 PE(S)는 Class C 및 Slow, 그리고 Rubber와 ST(J)는 Class B 및 Slow로 나타났다. 하지만, 난연 등급 평가 기준인 최대 발열량에 대한 시간평균 기울기는 시험 방법에 따라서 동일 보온재에 대하여 다르게 나타났으며, 보다 정확한 원인을 분석하기 위한 기초 연구가 필요한 것으로 판단된다.