• Title/Summary/Keyword: pinhole

Search Result 208, Processing Time 0.027 seconds

The Usefulness of Postoperative Pinhole Bone Scintigraphy in the Assessment of Prognosis after Multiple Drilling or Vascularized Bone Graft in Patients with Avascular Necrosis of Femoral Head (다발성 천공술 및 혈관 부착 골이식술을 시행한 대퇴골두 무혈관성 괴사의 예후: 수술 후 바늘구멍 골신티그라피의 유용성)

  • Chung, Yong-An;Kim, Sung-Hoon;Chun, Kyung-Ah;Park, Young-Ha;Sohn, Hyung-Seon;Chung, Soo-Kyo;Song, Mun-Kab
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.405-412
    • /
    • 1999
  • Purpose: It is important to evaluate the healing process of avascular necrosis (AVN) involving femoral head after treatment. The purpose of this study was to assess the usefulness of pinhole bone scintigraphy in the AVN of femoral head after surgery. Materials and Methods: We analyzed the changing pattern of pinhole bone scintigram in 21 femoral heads of 16 patients (14 lesions/11 male, 7 lesions/5 female, mean age: 39.4 yrs) before and after multiple drilling or vascularized bone grafting for AVN of the femoral head. In all patients, pre-operative scintigrams were obtained at 1 to 3 months before treatment and the first post-operative scintigrams were obtained at 1 to 3 months after treatment. All patients were followed for 2 to 4 years after operation. Results: The findings of the pinhole scintigrams were divided into three patterns: 1) curvilinear, 2) scattered spotty and 3) undetermined. The 10 of 11 lesions with curvilinear pattern had good postoperative clinical and radiological follow-up findings. However, all 6 lesions with scattered spotty pattern showed poor postoperative findings, which necessitated total hip joint replacement. Of the 4 lesions with undetermined pattern, 2 required total hip joint replacement. There was significant difference in postoperative prognosis between the curvilinear and scattered spotty patterns (p<0.05). Conclusion: We conclude that the pattern of pinhole bone scintigram obtained within 1 to 3 months after multiple drilling or vascularized bone graft operation is a useful prognostic indicator in the AVN of femoral head.

  • PDF

A STUDY ON THE SCATTER RADIATION AFFECTING THE DENTAL X-RAY FILM (산란 방사선이 치과용 방사선 필름에 미치는 영향에 관한 연구)

  • Park Eung Chun;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.87-94
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of scatter radiation to dental x-ray film with long time-exposure in the different structures of the tooth, by using pinhole camera. For this study, pinhole camera, skull with tooth, and pocket dosimeter were used. The radiation with 70 and 90kVp and exposure time (minimum: 2.5 min., maximum 10 hrs.) was projected to the film in the pinhole camera. And density of the obtained x-ray film was measured with densitometer. In the intra-oral film taking, the amount of exposure of the scatter radiation affecting the thyroid gland area was measured with the dosimeter at the thyroid gland. The density of radiographs was compared in radiation projected with or without the metal cone of dental machine. The effect of the back scatter radiation to the film was also evaluated when the lead foil was removed. The obtained results were as follows: 1. A pinhole camera was a valuable device for locating the source of x-ray. 2. The scatter radiation affected the dental x-ray film when the radiation source was exposed. more than 5 hours'. In that case, the density of the scatter radiation could be observed visually. 3. The scatter radiation caused by short exposure of dental radiation didn't affect the diagnostic quality of the dental x-ray film. 4. The differences of densities between the tooth and the soft tissue according to exposure time showed 0.16 in 5 hours' exposure & 0.17 in 10 hours' exposure at 70 kVp & 0.12 in 5 hours' exposure & 0.13 in 10 hours' exposure at the 90kVp. 5. The differences of densities between the tooth and the soft tissue according to kVp showed no difference between 5 hours' exposure of tooth at 70 kVp and soft tissue at 90 kVp, but showed 0.05 high density in tooth when 10 hours' exposure at 90 kVp. 6. No difference of density was on radiographs taken with or without dental machine cone. 7. Back scatter radiation was recorded image of radiographs for only 3 min. 8. The amounts of the scatter radiation exposed to the thyroid gland in intraoral film taking were 1.12 mr in upper anterior, 0.55 mr in upper posterior, 2.75 mr in lower anterior, and 1.92 mr in lower posterior teeth.

  • PDF

Effect of packaging conditions on the quality changes of fermented soy paste and red pepper paste (포장조건에 따른 한국전통 된장과 고추장의 품질변화)

  • Jang, Jae-Deck;Hwang, Yong-Il;Lee, Dong-Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.6 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • 180g of fermented soy paste and 150g of red pepper paste were packaged in glass jars of 232 mL with different conditions of active packaging and then stored at $13^{\circ}C$ for about 170 and 128 days, respectively. During the storage, package atmosphere, surface color, pH, acidity and microbial flora were monitored to see the effect of packaging conditions. Test packaging conditions include package equipped with $Ca(OH)_2\;as\;CO_2$ absorber, package with pinhole and closed control one. Closed control packages of soypaste and red pepper paste showed the increased $CO_2$ partial pressure, the decreased $O_2$ partial pressure and the constant $N_2$ partial pressure to produce high pressure buildup with storage. The paste packages with $Ca(OH)_2$ maintained relatively low $CO_2$ partial pressure and thus the package pressure close to normal atmospheric pressure for initial storage period of 70 days. The packages with air pinhole channel had the partial pressures of $O_2\;and\;N_2$ decreased with storage time, while $CO_2$ partial pressure first increased to a maximum and then slowly decreased thereafter Without any pressure increase the packages with pinhole gave the lowest quality changes possibly due to the effect of package atmosphere, but it had problem of mold contamination and growth for soy paste after 120 days. There were no difference in microbial flora between the packages after about 70 day storage.

  • PDF

Coded Aperture Gamma Camera for Thyroid Imaging: Monte Carlo Simulation (갑상선 영상 획득을 위한 부호화 구경 감마카메라: 몬테칼로 시뮬레이션 연구)

  • Beak, Cheol-Ha;Lee, Seung-Jae;Chung, Yong-Hyun
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.247-255
    • /
    • 2008
  • A coded aperture camera has been developed to improve the signal-to-noise ratio (SNR) while keeping the spatial resolution of a pinhole gamma camera. The purpose of this study was to optimize a coded aperture camera and to evaluate its possibility for thyroid imaging by Monte Carlo simulation. A clinical gamma camera, a pinhole collimator with 1.0 mm hole diameter, and a $79{\times}79$ modified uniformly redundant array (MURA) mask were designed using GATE (Geant4 Application for Tomographic Emission). The penetration ratio, spatial resolution, integral uniformity and signal-to-noise ratio (SNR) were simulated and evaluated as a function of the mask thickness. The spatial resolution of the coded aperture camera was consistent with the various mask thickness, SNR showed a maximum value at 1.2 mm mask thickness and integral uniformity was improved by increasing mask thickness. Compare to the pinhole gamma camera, the coded aperture camera showed improved SNR by a factor of 30 while keeping almost the same spatial resolution. In this simulation study, the results indicated that high spatial resolution and ultra-high SNR of the thyroid imaging are feasible using a coded aperture camera.

  • PDF

Discussion on Preliminary Test for Male High School Students in Gwang-ju Area (광주지역 남자 고등학생들의 예비검사에 대한 고찰)

  • Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.95-99
    • /
    • 2007
  • This study performed apreliminary test with male high school students in Gwangju metropolitan city in order to determine visual function information of high school students. For the items in this preliminary test, there were inquiry, test for long distance unaided visual acuity, pinhole visual acuity test, colour vision test, cover test and stereo test. Most complaint related to eye was about blurred vision (28.4%) and over 90% of subjects had one or more, and among them, over 50% appealed two or more complaints. 76.1% of all subjects showed less than 0.7 in unaided distance visual acuity. In pinhole visual acuity test, 98% had an improved unaided pinhole visual acuity and most of them experienced an improvement and 2% had no change or dropped. The students with normal stereoscopic vision test were 85.6% and the students under normal range were 14.4%. In colour vision test, 7.9% of them were protanomaly and deuteranomaly and none of them had trichromasy and total color blindness. In cover test, it showed 30.2% of orthophoria, 8.2% of esophoria and 61.5% of exophoria, and none of them had strabismus.

  • PDF

Evaluation of Validity Thyroid Scintigraphy Using Parallel Hole Collimator (갑상샘 신티그래피 검사 시 평행다공형 조준기 적용의 유효성 평가)

  • Su-Young Park;Ji-Youn Kim;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2024
  • In this study, When acquisition thyroid scintigraphy images, a parallel hole collimator was applied, and the difference from the pinhole collimator was quantitatively analyzed under each image acquisition condition. Visual size, resolution, sensitivity, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were evaluated using thyroid phantom and point source. When comparing visual size, it was confirmed that an image similar to the size of the pinhole collimator could be obtained only when a magnification ratio of about 2.00 to 2.09 times when applying a parallel hole collimator. There was no tendency in FWHM(mm) measurement using a point source, and sensitivity was high in the parallel hole collimator. SNR and CNR were high when using a low magnification ratio, matrix size of 128×128, and a parallel hole collimator. In images of similar size to the naked eye, when the matrix size was the same, both SNR and CNR were high in the pinhole collimator. Therefore, when performing a thyroid scintigraphy test, if appropriate conditions are set according to the situation of each hospital and a parallel hole collimator is applied, it can be a good option in terms of equipment utilization and work efficiency.