• Title/Summary/Keyword: pinch

Search Result 309, Processing Time 0.027 seconds

Diagnostics of Theta-Pinch Plasma by Magnetic Probe (자기 탐침에 의한 쎄타 핀치 플라즈마의 진단)

  • Shim, J.H.;Cho, J.H.;Chang, Y.M.;Chung, W.K.;Kang, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.401-404
    • /
    • 1989
  • Some magnetic probes for theta-pinch experiment have been constructed. Methods of building the coil, conecting it to the oscilloscope, shielding and enclosing the probe are discribed. Such a probe has been used to measure the magnetic flux penetrating it within theta - pinched plasmas.

  • PDF

Dynamic Modeling and Design of Finger Exoskeleton Using Polymer Actuator (고분자 구동체를 이용한 손가락 외골격기구의 설계 및 동력학적 모델 개발)

  • Jeong, Gwang-Hun;Kim, Yoon-Jeong;Yoon, Bye-Ri;Wang, Hyuck-Sik;Song, Dae-Seok;Kim, Sul-Ki;Rhee, Kye-Han;Jho, Jae-Young;Kim, Dong-Min;Lee, Soo-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.717-722
    • /
    • 2012
  • This paper presents the design and dynamic model of the finger exoskeleton actuated by Ionic Polymer Metal Composites (IPMC) to assist a tip pinch task. Although this exoskeleton will be developed to assist 3 degree-of-freedom motion of each finger, it has been currently made to perform the tip pinch task using 1 degree-of-freedom mechanism as the first step. The six layers of IPMC were stacked in parallel to increase the low actuation force of IPMC. In addition, the finger dummy was manufactured to evaluate the performance of the finger exoskeleton. The pinch task experiments, which were performed on the finger dummy with the developed exoskeleton, showed that the pinch force close to the desired level was obtained. Moreover, the dynamic model of the exoskeleton and finger dummy was developed in order to perform the various analyses for the improvement of the exoskeleton.

Numerical Simulation on the Formation and Pinching Plasma in X-pinch Wires on 2-D Geometry (자기유체역학 코드를 이용한 축 대칭 엑스 핀치 플라즈마 구조의 2차원 전산해석)

  • Byun, Sangmin;Na, Yong-Su;Chung, Kyoung-Jae;Kim, Deok-Kyu;Lee, Sangjun;Lee, Chanyoung;Ham, Seunggi;Ryu, Jonghyeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.211-218
    • /
    • 2021
  • This paper deals with the computational work to characterize the formation and pinching of a plasma in an X-pinch configuration. A resistive magnetohydrodynamic model of a single fluid and two temperature is adopted assuming a hollow conical structure in the (r,z) domain. The model includes the thermodynamic parameter of tungsten from the corrected Thomas-Fermi EOS(equation of state), determining the average ionization charge, pressure, and internal energy. The transport coefficients, resistivity and thermal conductivity, are obtained by the corrected Lee & More model and a simple radiation loss rate by recombination process is considered in the simulation. The simulation demonstrated the formation of a core-corona plasma and intense compression process near the central region which agrees with the experimental observation in the X-pinch device at Seoul National University. In addition, it confirmed the increase in radiation loss rate with the density and temperature of the core plasma.

Design of LTBC Controller for Tension Control in Down Coiler Process of Hot Strip Mills (열간압연 권취공정의 장력제어를 위한 LTBC 제어기 설계)

  • Lee, Sang Ho;Park, Hong Bae;Park, Cheol Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.4
    • /
    • pp.301-308
    • /
    • 2015
  • In this paper, we propose an LTBC (Low Tension and Load Balance Control) scheme to improve a coiling shape control by reduction the tension fluctuation by the torque disturbance in the down coiler process of hot strip mills. The proposed controller is a combination of an LTC to control the overload at load-on in the mandrel and an LBC to regulate the load balance of the upper and bottom pinch roll. A tension calculation model is suggested with the concept of the tension deviation. The effectiveness of the proposed control scheme is verified from simulation under a disturbance of the pinch roll torque. Using a field test, we show that the performance of the shape and tension control is improved by the LTBC control.

Analysis of Spray Mode Using Modified Pinch Instability Theory (핀치이론의 수정 모델을 이용한 스프레이 모드의 해석)

  • Park, Ah-Young;Hammad, Muhammad A.;Kim, Sun-Rak;Yoo, Choong-D.
    • Journal of Welding and Joining
    • /
    • v.27 no.5
    • /
    • pp.88-93
    • /
    • 2009
  • While the pinch instability theory (PIT) has been widely employed to analyze the spray transfer mode in the gas metal arc welding (GMAW), it cannot predict the detaching drop size accurately. The PIT is modified in this work to increase the accuracy of prediction and to simulate the molten tip geometry to be more physically acceptable. Since the molten tip becomes a cone shape in the spray mode, the effective wire diameter is formulated that the effective diameter is inversely proportional to current square. Modifications are also made to consider the finite length of the liquid column and current leakage through the arc. While the effective diameter influences drop transfer significantly, the current leakage has negligible effects. The effects of modifications on drop transfer are analyzed, and the predicted drop diameters show good agreements with the experimental data of the steel wire.

Pinch-Off Syndrome, a Rare Complication of Totally Implantable Venous Access Device Implantation: A Case Series and Literature Review

  • Ilhan, Burak Mehmet;Sormaz, Ismail Cem;Turkay, Rustu
    • Journal of Chest Surgery
    • /
    • v.51 no.5
    • /
    • pp.333-337
    • /
    • 2018
  • Background: Pinch-off syndrome (POS) is a rare complication after totally implantable venous access device (TIVAD) implantation. In cancer patients, it is important to prevent this rare complication and to recognize it early if it does occur. We present a case series of POS after TIVAD implantation and the results of a literature search about this complication. Methods: From July 2006 to December 2015, 924 permanent implantable central venous catheter implantation procedures were performed. The most common indication was vascular access for chemotherapy. Results: POS occurred in 5 patients in our clinic. Two patients experienced POS within 2 weeks, and the other 3 patients were admitted to department of surgery, Istanbul Faculty of Medicine at 6 to 14 months following implantation. The catheters were found to be occluded during medication administration, and all patients complained of serious pain. The transected fragments of the catheters had migrated to the heart. They were successfully removed under angiography with a single-loop snare. Conclusion: POS is a serious complication after TIVAD implantation. It is important to be aware of this possibility and to make an early diagnosis in order to prevent complications such as drug extravasation and occlusion events.

Kinematic characteristics of grip force in patients with cervical spondylosis

  • Lee, Bumsuk;Noguchi, Naoto;Kakiage, Daiki;Yamazaki, Tsuneo
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.2
    • /
    • pp.61-65
    • /
    • 2015
  • Objective: The aim of this study was to objectively evaluate sensory disturbance in cervical spondylosis using grip force and investigate the relationship between the grip force and upper extremity function. Design: Cross-sectional study. Methods: Eleven cervical spondylosis patients with paresthesia conducted grip and lift tasks using a precision grip with the tips of the thumb and index finger on either side. The sum of the grip force used during the first four seconds was calculated and defined as the total grip force. The cutaneous pressure threshold of the fingers, the pinch power, the grip power and three subtests of the Simple Test for Evaluating Hand Function (STEF) were also assessed. Correlations between the total grip force and cutaneous pressure threshold, pinch power, grip power, and STEF subtest times were evaluated. Results: We found that the total grip force correlated with the cutaneous pressure threshold (p<0.05). Moreover, the total grip force of the dominant thumb correlated with the results of the three STEF subtests (p<0.05). There were no significant correlations between the total grip force and pinch/grip powers. Conclusions: We found that the total grip force correlated with cutaneous pressure threshold and upper extremity function. The results suggest that the total grip force could serve as an objective index for evaluating paresthesia in cervical spondylosis patients, and that the impaired ability of the upper extremity function is related to grip force coordination.

Prediction of Inelastic Force-Displacement Relationships of Reinforced Concrete Shear Wall Systems Based on Prescribed Ductilities (강성저하 실험식 및 연성계수를 이용한 철근콘크리트 전단벽 구조시스템의 비탄성 하중-변위 관계식 예측)

  • 홍원기
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.159-171
    • /
    • 1995
  • The parameters describing a complete hysteresis loop include pinch force, drift offset, effective stiffness, unloading and reloading trangential stiffness. Analytical equations proposed to quantify the nonlinear, inelastic behavior of reinforced shear walls can be used to predict these parameters as a function of axial load and drift ratio. For example, drift offset, effective stiffness, and first and second unloading and reloading tangential stiffness are calculated using equations obtained from test data for a desired drift ratio or ductility level. Pinch force can also be estimated for a given drift ratio and axial load. The effective virgin stiffness at the first yield and its post yield reduction can be estimated. The load deflection response of flexural reinforced concrete shear walls can now be estimated based on the effective wall stiffness that is a function of axial force and drift ratio.

  • PDF

Changes in Pain, Muscle Strength and Flexibility according to Pinch Lift and Rubbing Manual Therapy and Stretching Application for Low Back Pain (스트레칭과 PMT 적용에 따른 요통환자의 통증, 근력, 유연성의 변화)

  • Paek, Yun Woong;Min, Soon;Lee, Byung Hoon;Shin, Myeong Gi
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Purpose: This research was implemented for men in their thirties who have lower back pain to observe general activity disorder patterns during pinch lift and rubbing manual therapy (PMT) and stretching application. Methods: Participants were divided into three groups: The PMT Group used applied pinch lift and rubbing manual therapy; the STR Group used applied stretching; and the CON Group was the control group. Participants for each group received treatments that were conducted three times a week for a total five weeks. Measures of pain utilized Visual Analogue Scale (VAS) [INCOMPLETE SENTENCE]. Results: There were significant differences between the PMT Group and the CON Group as well as the STR Group and the CON Group for pain, muscle strength and flexibility. There was a significant difference in pain between the PMT Group and the STR Group. Conclusion: As a result, it is inferred that PMT and stretching positively influenced recovery with regards to pain, muscle strength and flexibility relief; however PMT is more effective for pain relief than stretching.

Effects of Comprehensive Rehabilitation Program on Physical Function and Fatigue in Mastectomy Patients (유방절제술 환자를 위한 통합적 재활 프로그램이 신체 기능과 피로에 미치는 효과)

  • Yoo, Yang-Sook;Jung, Sang-Seol;Cho, Ok-Hee
    • Korean Journal of Adult Nursing
    • /
    • v.17 no.2
    • /
    • pp.298-309
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate the effect of a comprehensive rehabilitation program on grip strength, pinch strength, the shoulder joint function, flexibility, and fatigue in mastectomy patients. Method: The subjects were fifty-five women with breast cancer (27 in the control group and 28 in the experimental group). The subjects in the experimental group participated in a comprehensive rehabilitation program for 10 weeks, which was composed of education, stress management, exercise, and peer support group activity. Results: The results revealed that the increase in grip strength, key pinch, the shoulder joint function, and flexibility (Back & Reach test, Standing & Bending reach test) of the operated extremity, and the decrease in fatigue were significantly higher in the experimental group than in the control group. However, the results revealed that tip strength and palmar pinch of the experimental group increased but there was no significant difference from that of the control group. Conclusions: The 10-week comprehensive rehabilitation program showed much affirmative effect on physical function, and fatigue of breast cancer patients after mastectomy.

  • PDF