• Title/Summary/Keyword: pin support

Search Result 65, Processing Time 0.036 seconds

The Method for Replacement of Strain Pole Crossarm using the Hot-line Support Arm (핫라인 써포트암을 이용한 완철교체공법)

  • Mun, S.W.;Park, Y.B.;Kim, J.S.;Song, H.S.;Cho, S.H.;Choi, M.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.59-64
    • /
    • 2006
  • In this paper, developed a uninterruptible hotline tools and method for replacement of strain pole crossarm on overhead distribution line. For practical use of developed tools, following direct hot-line methods were proposed: 'Direct hot-line method for replacement of pin pole crossarm', 'Direct hot-line method for alteration of crossarm' and 'Crossarm replacement method in uninterruptible cable displacement area'. These methods were proposed more simple and safe working on hotline job.

  • PDF

The Effect of Auricular Acupressure Therapy on Dysmenorrhea for Women Working in the Hospital (이압요법이 병원여성근로자의 월경곤란증에 미치는 효과)

  • Oh, Eun Ju;Jang, Ok Jeom;Jeong, Hyen Ja;Lee, Hae Jin;Kim, Eun Jung
    • Journal of Korean Clinical Nursing Research
    • /
    • v.14 no.1
    • /
    • pp.113-123
    • /
    • 2008
  • Purpose: This study was done to provide support material to traditional nursing interventions through investigation of the effect of Auricular acupressure therapy for female staff in the hospital who have dysmenorrhea but cannot be absent from work even with severe symptoms affecting their work and therefore cannot get proper pain management. Method: The participants in this study were 62 women were working in the G-university hospital in Jin-ju, assigned to experimental (30) and 32 control groups (32). The study method was a quasi-experimental, nonequivalent control group non-synchronized design. The experimental group received acupressure treatment (a pin was attached to tape) on the special stimulation points in the inside of the ear, 5 times for 5 seconds, morning, afternoon, and night. Tape without the pressure pin was applied to the same points for women in the control group to evaluate placebo effect. Data were collected from May to November 2007 and were analyzed using SPSS PC+ 12 version. Descriptive statistics, t-test, $x^2-test$, Fisher's exact test, paired t-test, were used to analyze the data. Results: The experimental group showed a significant decrease in dysmenorrhea compared to the control group (t=-2.743, p<.01). In the sub-part, the experimental group showed menstruation related pain (t=-3.726, p<.01), menstruation related to behavioral change (t=-2.421, p<.05) and symptoms however, there was no significant difference related to attention deficit, water retention, and negative image. Conclusion: Application of auricular acupressure therapy was approved for this study and although auricular acupressure therapy was not effective for all of the symptoms, it was effective for dysmenorrhea.

  • PDF

Prosthetic rehabilitation for patient with hemi-maxillectomy: Obturator combined with a hybrid telescopic double crown using friction pin (편측 절제된 상악골 환자에서 하이브리드 텔레스코픽 이중관 의치를 이용한 구강 폐색기 수복 증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.317-323
    • /
    • 2018
  • When oral cancer develops in the maxilla, oro-nasal communication occurs after surgical treatment including removal of the primary site. Restoration through an obturator is necessary to prevent food from storing due to non-oral opening, and to ensure proper pronunciation and aesthetic restoration. In this case, the patient was treated with right hemi-maxillectomy due to oral cancer and has residual abutment and poor periodontal support due to the effect of head and neck radiotherapy. The obturator was treated with a hybrid telescopic double crown denture. Reporting a successful prognosis in 18 months of follow-up.

An initial investigation of the inverted trussed beam formed by wooden rectangular cross section enlaced with wire rope

  • Gesualdo, F.A.R.;Lima, M.C.V.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.2
    • /
    • pp.239-255
    • /
    • 2012
  • This work presents a contribution to understand the inverted trussed beams behavior. The system has a main beam and struts with rectangular cross section associated to a wire rope enlaced to the main beam. It is an unpublished system with the advantage of easy positioning of the wire rope, once it is a continuous and connected by turnbuckles. It is a system that can be used as support for concrete formworks or for rehabilitation wooden beams proposal. The enlacement of the cable demands a small notch at the top of the cross section and a cross pin at the bottom. Six inverted trussed beams were tested, with spans of 180 cm with cables diameter of 1/4". Additionally, four simple beams without any external steel cable were also tested with material from the same lot of wood, allowing a comparison in rupture. The results showed capacity gain of around 60% compared to a simple beam. Once the wire rope characteristics and anchoring are very important for structure response, some improvement suggestions for the efficiency of the cables are also presented.

The Oil Film Analysis of Dynamically Loaded proceeding Bearing in Diesel Engine (동하중(動荷重)을 받는 선박용(船舶用) 디젤 엔진의 저널 베어링 유막해석(油膜解析)에 관한 연구(硏究))

  • Cha, Ji-Hyoub;Lee, Sang-Su;Kim, Jeong-Ryul;Kim, Ju-Tae;Kim, Jong-Seok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.160-165
    • /
    • 2005
  • The proceeding bearings of marine diesel engine are affected by dynamic loads from the cylinder gas pressure and the inertia force from the crank mechanism. Oil film must support the load of the shaft and it also must protect the proceeding and the bearings from damage. This study uses Goenka's new curve fit to carry out the theoretical analysis of oil film in proceeding bearings for MAN B&W 12K90MC-C and Hyundai Heavy Industry Co., Ltd HiMSEN H21/32 Engine. The applied engine's analysis results show the behavior of the proceedings in main and crank pin bearings. The results of this study will be the proper criteria for the proceeding bearings design and be available for development of the new technology in the proceeding bearing and for the high strength lining coating.

  • PDF

A study on the operation method of safety device of rotating quick coupler (회전 퀵커플러 안전장치 동작방법 연구)

  • Song, Jong-Won;Song, Chil-Sung
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.8-13
    • /
    • 2021
  • Excavators are construction machines used for digging soil, transporting soil, dismantling buildings and clearing the ground at construction sites. There are various attachments attached to the arm end of the excavator and used for various operations. There are the most common types of buckets attached for excavation and other types of attachments used for foresting, road cleaning, snow removal, and waste disposal. When multiple types of work are done at the same time, several attachments must be replaced and a device called a quick coupler is used to reduce replacement time. Although a quick coupler reduces the replacement time of the Attachment, it is necessary to attach safety devices to prevent unintentional detachment of attached attachments during the operation. To prevent the attachment from leaving or falling regardless of the operator's intention, support is installed in the hook of the bucket pin and controlled through a separate hydraulic cylinder to ensure safety. When attaching an attachment, it shall be attached without any action. This study is intended to verify the design validity of safety devices to prevent falls of attachments occurring at construction sites.

A class of actuated deployable and reconfigurable multilink structures

  • Phocas, Marios C.;Georgiou, Niki;Christoforou, Eftychios G.
    • Advances in Computational Design
    • /
    • v.7 no.3
    • /
    • pp.189-210
    • /
    • 2022
  • Deployable structures have the ability to shift from a compact state to an expanded functional configuration. By extension, reconfigurability is another function that relies on embedded computation and actuators. Linkage-based mechanisms constitute promising systems in the development of deployable and reconfigurable structures with high flexibility and controllability. The present paper investigates the deployment and reconfigurability of modular linkage structures with a pin and a sliding support, the latter connected to a linear motion actuator. An appropriate control sequence consists of stepwise reconfigurations that involve the selective releasing of one intermediate joint in each closed-loop linkage, effectively reducing it to a 1-DOF "effective crank-slider" mechanism. This approach enables low self-weight and reduced energy consumption. A kinematics and finite-element analysis of different linkage systems, in all intermediate reconfiguration steps of a sequence, have been conducted for different lengths and geometrical characteristics of the members, as well as different actuation methods, i.e., direct and cable-driven actuation. The study provides insight into the impact of various structural typological and geometrical factors on the systems' behavior.

Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants (장기간 사용한 이중관 의치의 실패원인 및 자연치와 임플란트를 이용한 이중관 의치 수복증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.384-390
    • /
    • 2018
  • Hybrid telescopic double crown have ever been good treatment option for patient with periodontally unfavorable few remaining teeth for successful prognosis. Tooth and implant combined telescopic double crown can be used for improving retention and support for denture with strategically placed implants on edentulous ridge. In this case, an 55-year-old female patient had chronic periodontitis with few remaining teeth on maxilla and fixed partial prosthodontics on mandible. Treatment of hybrid telescopic double crown with friction pin lasted 9.5 years only with natural teeth. After 9.5 years, additional implants was installed due to fracture of cast-posted abutment teeth. After implantation, tooth and implant combined double crown had fabricated. Through re-treatment, no complications of new denture has been found during 2 years follow up. This case presents fair prognosis of tooth and implant combined double crown denture in periodontally unfavorable condition.

Stafne Bone Cavity of the Mandible

  • Lee, Jae Il;Kang, Seok Joo;Jeon, Seong Pin;Sun, Hook
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.162-164
    • /
    • 2016
  • Stafne bone cavity is a rare mandibular defect that was first reported by Edward C. Stafne in 1942. It commonly presents with a well-demarcated, asymptomatic, unilateral radiolucency that indicates lingual invagination of the cortical bone. A 52-year-old female patient who with nasal bone fracture, visited the hospital. During facial bone computed tomography (CT) for facial area evaluation, a well-shaped cystic lesion was accidentally detected on the right side of the mandible. Compared to the left side, no swelling or deformity was observed in the right side of the oral lesion, and no signs of deformity caused by mucosal inflammation. 3D CT scans, and mandible series x-rays were performed, which showed a well-ossified radiolucent oval lesion. Axial CT image revealed a cortical defect containing soft tissue lesion, which has similar density as the submandibular gland on the lingual surface of the mandible. The fact that Stafne cavity is completely surrounded by the bone is the evidence to support the hypothesis that embryonic salivary gland is entrapped by the bone. In most cases, Stafne bone cavity does not require surgical treatment. We believe that the mechanical pressure from the salivary gland could have caused the defect.

Experimental study of extracting artificial boundary condition frequencies for dynamic model updating

  • Hou, Chuanchuan;Mao, Lei;Lu, Yong
    • Smart Structures and Systems
    • /
    • v.20 no.2
    • /
    • pp.247-261
    • /
    • 2017
  • In the field of dynamic measurement and structural damage identification, it is generally known that modal frequencies may be measured with higher accuracy than mode shapes. However, the number of natural frequencies within a measurable range is limited. Accessing additional forms of modal frequencies is thus desirable. The present study is concerned about the extraction of artificial boundary condition (ABC) frequencies from modal testing. The ABC frequencies correspond to the natural frequencies of the structure with a perturbed boundary condition, but they can be extracted from processing the frequency response functions (FRF) measured in a specific configuration from the structure in its existing state without the need of actually altering the physical support condition. This paper presents a comprehensive experimental investigation into the measurability of the ABC frequencies from physical experiments. It covers the testing procedure through modal testing, the data processing and data analysis requirements, and the FRF matrix operations leading to the extraction of the ABC frequencies. Specific sources of measurement errors and their effects on the accuracy of the extracted ABC frequencies are scrutinised. The extracted ABC frequencies are subsequently applied in the damage identification in beams by means of finite element model updating. Results demonstrate that it is possible to extract the first few ABC frequencies from the modal testing for a variety of artificial boundary conditions incorporating one or two virtual pin supports, and the inclusion of ABC frequencies enables the identification of structural damages without the need to involve the mode shape information.