• Title/Summary/Keyword: pilotis structure

Search Result 18, Processing Time 0.018 seconds

4th Industrial Revolution Construction IT Convergence Technology Based Bridge System CFT for Seismic Performance Improvement and Performance Evaluation of Buildings Using Drones (4차산업혁명 건설IT융합기술기반 내진성능향상을 위한 Bridge System CFT 개발 및 드론을 이용한 건축물 성능검토)

  • Kim, Dae-Geon;Jang, Yu-Gyeong;Moon, Won-Kyu;Lee, Da-Sol;Park, Su-Bin;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.177-178
    • /
    • 2018
  • Unlike the projects that the government has implemented recently to develop new cities under the New Deal project, Saeddeul Village projects to improve the environment of the city are gaining attention. The problem has been found to be that many of the buildings in Saeddeul Village are still not earthquake-proof by using drones to review the state of the town. It also revealed that after two years of earthquakes, Pilotis structures are the most vulnerable to earthquakes. However, it is suitable for small spaces in the city because it provides parking spaces as well as residential spaces. Accordingly, the focus should be on repair and reinforcement rather than reconstruction. In this study, a concrete-based seismic design and construction method is developed in the columns of the existing pylotis structure.

  • PDF

Seismic Performance of Low-rise Piloti RC Buildings with Concentric Core (중심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능)

  • Yoon, Tae-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.611-619
    • /
    • 2022
  • In this study, the seismic performance of low - rise piloti buildings with concentric core (shear wall) position is analysed and reviewed based on KDS 41. The prototype is selected among the constructed low - rise piloti buildings with concentric core designed based on KBC 2005 which was used for many low - rise piloti buildings construction. The seismic performance of the building shows plastic behavior in X-direction and elastic behavior in Y-direction. The inter-story drift is lager than that of concentric core case and is under the maximum allowed drift ratio. The displacement ratio of first story is much lager the that of upper stories, and the frame structure in the first story is evaluated as vulnerable to lateral force. Therefore, low - rise piloti buildings with concentric core need the diminishment of lateral displacement and reinforcement of lateral resistance capacity in seismic design and seismic retrofit.

A Study on the Analysis of Fire Risk and Field Survey for FilottI Structures (필로티 구조물의 화재위험성 분석 및 현장조사에 관한 연구)

  • Han, Ji-Woo;Lee, Byeong-heun;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.45-46
    • /
    • 2018
  • The fire at the pilotis parking lot shows the fire propagation paths that are propagated to the ceiling materials and insulation materials and propagated through the external walls. In addition, there is a high risk of fire caused by vehicles with high combustion loads spreading throughout the parking lot. In particular, the omission of the ceiling materials at the parking lot in recent fire cases has contributed to the spread of the fire. In this study, the combustion performance of the ceiling materials between the insulation material and the vehicle is considered to prevent fire from spreading. Based on field research, the type of ceiling material used in the piloti structure showed that SMC ceiling materials have the highest percentage. Combustion performance test (KS F ISO 5660-1) was carried out on the SMC ceiling materials and the AL ceiling materials to review the fire safety of the ceiling finish based on the field investigation. The results of the test showed that the SMC ceiling materials has a THR 28.973[MJ/㎡] and peek HRR 273.93 [kW/㎡], while the AL ceiling material has a THR 0.584[MJ/㎡] and peek HRR 15.215[kW/㎡].

  • PDF

A Study on the Height Limitation of a Building in Building Law - Focusing on the Standard of the Ground Level Calculation - (건축법(建築法)에서의 건축물(建築物) 높이제한규정(制限規定) - 지표면산정기준(地表面算定基準)을 중심(中心)으로 -)

  • Kim, Soo-Young
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.29-38
    • /
    • 2003
  • The articles on building height limitation are very important to form buildings to be. The application of the articles is based on the surface of the building site ground, that is, the definite judgment of ground level should ensure the correctness of building height limitation. This study surveyed the recognition degree of practitioners about the building height limitation regulations by questionnaires, and analyzed its results and compared them to related building laws and letter of reply from the office to practitioners' inquiry on related regulation. The study summarized the results as follows; 1. It is not clear to judge the ground level. Especially in cases of pilotis structure, there would be various interpretations to define its ground level. 2. According to present building regulations, the site would be confused to define by practitioners whether it is stiff or plain. 3. In case of regulation of a right to enjoy sunshine, it is hard to calculate the average horizontal level(ground level) with neighboring sites. 4. If there were a manual with illustrations for judging and calculating the ground level of various cases, civil petitions would be reduced.

  • PDF

Influence of pinching effect of exterior joints on the seismic behavior of RC frames

  • Favvata, Maria J.;Karayannis, Chris G.
    • Earthquakes and Structures
    • /
    • v.6 no.1
    • /
    • pp.89-110
    • /
    • 2014
  • Nonlinear dynamic analyses are carried out to investigate the influence of the pinching hysteretic response of the exterior RC beam-column joints on the seismic behavior of multistory RC frame structures. The effect of the pinching on the local and global mechanisms of an 8-storey bare frame and an 8-storey pilotis type frame structure is evaluated. Further, an experimental data bank extracted from literature is used to acquire experimental experience of the range of the real levels that have to be considered for the pinching effect on the hysteretic response of the joints. Thus, three different cases for the hysteretic response of the joints are considered: (a) joints with strength and stiffness degradation characteristics but without pinching effect, (b) joints with strength degradation, stiffness degradation and low pinching effect and (c) joints with strength degradation, stiffness degradation and high pinching effect. For the simulation of the beam-column joints a special-purpose rotational spring element that incorporates the examined hysteretic options developed by the authors and implemented in a well-known nonlinear dynamic analysis program is employed for the analysis of the structural systems. The results of this study indicate that the effect of pinching on the local and global responses of the examined cases is not really significant at early stages of the seismic loading and especially in the cases when strength degradation in the core of exterior joint has occurred. Nevertheless in the cases when strength degradation does not occur in the joints the pinching may increase the demands for ductility and become critical for the columns at the base floor of the frame structures. Finally, as it was expected the ability for energy absorption was reduced due to pinching effect.

Study on the Seismic Performance for Low-rised RC Building with Vertical and Torsional Irregularities (수직비정형과 비틀림비정형을 동시에 가지는 저층 RC 건물의 내진성능에 관한 연구)

  • Choi, In-Hyuk;Baek, Eun-Rim;Lee, Sang-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.12
    • /
    • pp.137-148
    • /
    • 2019
  • Korean piloti-type buildings are comprised of pilotis in the first story and shear walls in the upper stories. This vertical irregularity causes excessive lateral plastic deformation on the first story while the upper stories stay elastic. Meanwhile, asymmetric position of structural components such as core walls and columns of RC piloti-type buildings tends to produce torsional irregularities of the structures. Korean Building Code(KBC2016) requires the special seismic load and torsional amplification factor to apply to the piloti-type buildings lower than six-story or 20m if it has vertical and torsional irregularities when the building corresponds to seismic design category C or D. Many Korean low-rised RC buildings fall into the class. Therefore, the special earthquake load and torsional amplification factor are often applied to a building simultaneously. However, it has not been studied enough how much influence each parameter has on buildings with vertical and torsional irregularities at the same time. The purpose of this study is to evaluate the effect of factor special seismic load and torsional amplification on seismic performance of irregular buildings. In this study, a damaged 4th story piloti-type building by the Pohang earthquake was selected and the earthquake response analysis was carried out with various seismic design methods by the KBC 2016. The effect of the design parameters on seismic performance was analyzed by the dynamic analysis of models with special seismic load and torsional amplification factor based on the selected building. It was concluded that the application of the torsional amplification factor to the reference model to which special seismic design was applied, does not significantly affect the seismic performance.

The Improvement Direction of Piloti Space for Neighborhood Regeneration of Deteriorated Low-Rise Residential Block (노후 저층주거지 근린재생을 위한 필로티 공간 개선 방향)

  • Yoo, Hae-Yeon;Song, Jun-Yeop;Yang, Ji-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.761-770
    • /
    • 2017
  • The objective of this study is to propose a community facility design for the revitalization of the piloti spaces of deteriorated low-rise residential blocks. For this study, the precedent research and institutional limitations are examined. In addition, this study selected and analyzed a deteriorated low-rise residential block utilizing pilotis. Generally, in this type of residence, 8 to 10 generations live together in multi-family houses and row houses, so it is a type of housing that lacks both public space and parking places. Therefore, we attempted to improve the situation of the communities by making use of the space between the pillars and walls without infringing on the parking places. In addition, we took into consideration the design and arrangement of the piloti by evaluating the inconveniences and needs of the residents through interviews. Specifically, various modules were planned and used to transform the spaces between the pillars of the pillar type piloti structure. This study examined the possibilities offered by various materials and modules, and studied the diverse possibilities that can be offered by changing the modules.

Seismic Performance of Low-rise Piloti RC Buildings with Eccentric Core (편심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능)

  • Kim, Sung-Yong;Kim, Kyung-Nam;Yoon, Tae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.490-498
    • /
    • 2020
  • In this study, the seismic performance of low-rise piloti buildings with eccentric core (shear wall) positions was analyzed and reviewed. A prototype was selected among constructed low-rise piloti buildings with eccentric cores designed based on KBC2005. The seismic performance of the building showed plastic behavior in the X-direction and elastic behavior in the Y-direction. The inter-story drift is larger than that of a concentric core case and has the maximum allowed drift ratio. The displacement ratio of the first story is much larger than that of upper stories, and the frame structure in the first story is vulnerable to lateral force. Therefore, low-rise piloti buildings with eccentric cores need to have less lateral displacement, as well as reinforcement of the lateral resistance capacity in seismic design and seismic retrofit.