• 제목/요약/키워드: pile load test

검색결과 554건 처리시간 0.028초

해상 강관말뚝의 설계 및 항타시공관리 사례연구 (A Case Study on the Design and Drivability Criteria of Steel Pile in Offshore)

  • 송명준;박영호;유석준;심동현
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.75-85
    • /
    • 2006
  • The project comprised the construction of the new oil pier and associated topside facilities and demolition of exiting south pier. The site is located approximately 33km south of Kuwait city at MAA refinery. The approach trestle and berth structures of the new oil pier were designed to be supported by steel tubular piles Total 2,480 numbers of piles(795 piles at Approach Trestle, 1187 piles at Berth 1 -4 and 498 piles at Berth 5-6) had to be driven through the calcareous silty sand In this study, the design procedures for offshore steel pipe piles, evaluation for the compression and tension capacities by static and dynamic load test and effective driving criteria by the final set values are discussed

  • PDF

풍화된 암반에 근입된 현장타설말뚝의 선단지지거동 (End Bearing Behavior of Drilled Shafts in Weathered Rock)

  • 권오성;김명모
    • 대한토목학회논문집
    • /
    • 제28권4C호
    • /
    • pp.197-203
    • /
    • 2008
  • 풍화된 암반에 근입된 말뚝의 선단지지거동은 신선암의 강도보다는 절리를 포함한 암반 상태에 의존한다. 본 연구에서는 암반상태가 말뚝의 선단지지력에 미치는 영향을 알아보기 위해 먼저 총 4부지의 암반에 근입된 13본의 현장타설콘크리트 말뚝에 대한 재하시험, 그리고 재하시험 부지의 지반조사 자료를 포함하는 데이터베이스를 구축하고, 말뚝선단부의 거동과 암반물성치의 상관관계를 분석하였다. 선단지반반력계수와 암반물성치의 상관관계 분석 결과 암석의 일축압축강도와 지반반력계수 사이에는 일관된 상관관계를 찾을 수 없었으나, 암반의 상태를 나타내는 물성치인 $E_m$, $E_{ur}$, RMR, 그리고 RQD 등과 지반반력계수의 상관계수는 대부분 0.7 이상으로 매우 뛰어난 상관성을 보였다. 또한, 기존의 방법으로 추정한 선단지지력과 실측 선단지지력의 비교를 통해 기존 방법의 적용성을 검증하였다.

Piled Raft 기초의 비선형 하중-침하 특성을 고려한 하중분담 해석 (Load Sharing Analysis of Piled Rafts Based on Non-linear Load-Settlement Characteristics)

  • 최규진;박동규;이준환
    • 한국지반공학회논문집
    • /
    • 제28권11호
    • /
    • pp.33-40
    • /
    • 2012
  • 말뚝과 raft의 하중 분담 효과를 고려한 Piled Raft 기초의 설계는, 말뚝의 지지력만을 고려하여 설계하는 기존의 말뚝기초 설계 방식에 비해 경제적인 설계를 가능하게 해준다. 일반적으로 Piled Raft 기초 거동의 해석 및 설계는, 해석의 복잡성으로 인해 주로 컴퓨터를 이용한 수치 해석을 이용하고 있으며, 하중 분담 효과에 대한 해석 또한 개별적 상황에 따른 수치해석의 결과로 이루어진다. 본 연구에서는 기초 요소의 하중-침하 특성을 고려하여 Piled Raft 기초에서의 수직하중에 대한 raft와 말뚝의 하중 분담 효과를 평가할 수 있는 모델을 제안하고자 하였다. 기초의 비선형적 거동을 고려하여 말뚝과 raft의 거동을 각각 쌍곡선(hyperbolic curve) 형태의 정규화된 하중-침하 곡선(normalized load-settlement curve)으로 표현하고, 이를 통해 기초의 침하에 따른 말뚝과 raft의 하중 분담 정도를 평가할 수 있는 모델을 제시하였다. 또한 제시한 모델의 적용성을 평가하기 위하여 Piled Raft 기초에 대한 원심모형실험 결과와 비교하였다. 그 결과, 제시한 모델과 원심모형실험 결과로부터 나타난 침하에 따른 하중 분담률의 변화 양상이 전체적으로 유사한 형태를 보였다.

인발력을 받는 팩마이크로파일의 주면마찰력 (Skin Friction Mobilized on Pack Micropiles Subjected to Uplift Force)

  • 홍원표;조삼덕;최창호;이충민
    • 한국지반공학회논문집
    • /
    • 제28권6호
    • /
    • pp.19-29
    • /
    • 2012
  • 일반마이크로파일의 저항성능을 개선시키기 위해 최근에 토목섬유을 활용한 팩마이크로파일이 개발되었다. 팩마이크로파일은 일반마이크로파일의 강봉이나 강관을 토목섬유팩으로 감싸고 주입재와 주입압을 토목섬유팩 내부에 가하여 제작한다. 이 주입압에 의하여 천공 직경이 크게 확대된다. 동일한 한 지반 속에 설치된 세 개의 마이크로파일을 대상으로 일련의 말뚝인발시험을 실시하였다. 세 말뚝 중 두 개는 팩마이크로파일였고 나머지 하나는 강봉을 사용한 일반마이크로파일이였다. 토목섬유팩에 적용된 주입압에 의하여 팩마이크로파일의 경우 천공직경이 152mm에서 220mm으로 확대되었다. 마이크로파일의 주면에서 발달하는 단위주면마찰력은 말뚝두부의 인발변위량의 증가와 함께 서서히 증가하여 한계상태에 도달한 한계변위량에서 수렴치에 도달한다. 팩마이크로파일의 인발저항력은 일반마이크로파일의 인발저항력보다 크게 나타난다. 이와 같은 팩마이크로파일의 인발저항력을 증대시킬 수 있는 원인으로는 크게 두 가지를 생각할 수 있다; 첫째는 마이크로파일에 설치한 토목섬유팩내 주입압으로 마이크로파일의 단면적을 증대시키므로 말뚝주면의 마찰저항면적을 증대시킬 수 있기 때문이고, 둘째는 마이크로파일의 단면이 확대될 때 확대되는 부분의 체적만큼의 토사가 주변지반을 압축시켜 말뚝과 지반 사이의 마찰저항력을 증대시킬 수 있기 때문이다. 이 압축효과는 지표면 부근 보다 깊은 지층에서 크게 나타났다. 말뚝 주면에서 발휘되는 단위주면마찰력은 말뚝의 직경이 작은 경우가 더 크게 발휘된다. 즉 마이크로파일의 주면에서 발달되는 단위주면마찰력은 대구경 현장타설말뚝의 주면에서 발달되는 단위주면마찰력보다 크게 나타난다.

송도지역 내 PHC 말뚝기초 적용사례분석을 통한 적정 시공방법 연구 (Study on the Rational Construction Method Using Analysis of the Case Study of PHC Pile Foundation in Song-Do Area)

  • 이병호;이종휘;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제12권3호
    • /
    • pp.55-61
    • /
    • 2011
  • 송도 국제화 복합단지는 대규모 간척사업을 통해 조성된 지역이며 준설매립층을 포함 느슨한 실트층과 연약한 점토층, 모래층 등이 교호하여 퇴적되어 있다. 따라서 본 지역에 구조물을 안전하게 설치하기 위해서는 말뚝기초의 사용이 불가피하다. 송도 국제화 복합단지 내 말뚝기초 적용현장의 경우, 환경적인 조건과 경제적인 측면에서 항타방식의 PHC 말뚝이 대부분 적용되었다. 최근 송도 국제화 복합단지 5~7공구 내 PHC 말뚝기초를 적용하여 시공된 4개 현장을 분석한 결과 퇴적층 내 경질층의 출현 및 30m 이상의 말뚝설치로 인해 항타방식의 시공은 어려움이 많은 것으로 나타났다. 이 경우 적절한 심도까지 선 천공 후 항타 관입을 시행하여 말뚝을 설치했을때 시공성 분석결과 매우 양호한 결과를 얻었다. 또한 경제성의 경우에도 약 4% 정도의 상승으로 시공성 향상에 비해 매우 미소한 증가임을 알 수 있었다. 안정성 측면에서는 재하시험을 통해 확인한 결과 말뚝재료의 허용응력 대비 약 70% 이상을 만족하는 것으로 확인되었다. 이상의 분석결과를 통해 볼 때 송도지역 내 PHC 말뚝 적용은 퇴적 환경을 고려하여 조밀한 모래층을 선 천공한 후 항타를 통해 양호한 지지층에 설치하는 방법이 가장 합리적인 것으로 판단되었다.

다중화된 FBG센서를 이용한 중공 내민보의 정적 거동 분석 (Static Behavior of Hollow Cantilever Beam Using Multiplexed FBG Sensors)

  • 이태희;강동훈;정원석;목영진
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.316-322
    • /
    • 2009
  • 본 연구는 광섬유 브래그 격자(fiber Bragg grating, FBG)센서를 이용하여 캔틸레버의 수직 처짐을 산정하고 이를 통하여 횡방향 하중을 받는 말뚝기초 거동 분석을 위한 사전연구를 수행하는데 목적이 있다. 말뚝기초를 모형화한 길이 1.7 m의 정방 중공 형강 내민보를 실험실에 설치하고 실험체 측면의 상하부 표면에 4개의 센서로 다중화 된 2쌍의 FBG 센서를 설치하였다. 결과 비교를 위해 FBG 센서가 설치된 동일 위치에 전기식 게이지를 설치하였다. 하중은 고정 단에서 1.47m 지점에 엑츄에이터를 통한 변위 제어 방법으로 재하 하였다. 실험을 통해 측정된 FBG 센서의 파장변화로부터 변형률과 곡률을 산정하였고 기하학적 처짐-곡률관계와 회귀분석을 통하여 처짐을 유추하였다. FBG 센서를 통해 산정된 변형률과 처짐을 각각 전기식 게이지의 변형률 측정값, 이론 처짐값과 비교분석 하였다. 측정된 FBG 센서와 전기식 게이지의 변형률은 근사한 결과를 나타내었으며, 이론적으로 산출한 처짐과 FBG 센서로부터 도출한 처짐도 우수한 상관관계를 보였다. 실험결과를 통하여 FBG 센서를 도입한 말뚝 기초 거동분석을 성공적으로 이루어내기 위해서는 FBG 센서로 측정 가능한 한계 변위의 산정 및 증대 방안이 필요하며, 센서 오작동시 대처 방법에 대한 추가 연구가 필요하다고 판단된다.

그라우팅(C.G.S)에 의한 구조물 기초 보강 (Reinforcement of the Structure Foundation using Grouting(C.G.S))

  • 천병식;김진춘;권형석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 연약지반처리위원회 학술세미나
    • /
    • pp.1-11
    • /
    • 2000
  • The use of Compaction Grouting evolved in 1950's to correct structural settlement of buildings. Over the almost 50 years, the technology has been developed and is currently used in wide range of applications. Compaction Grouting, the injection of a very stiff, 'zero-slump' mortar grout under relatively high pressure, displaces and compacts soils. It can effectively repair natural or man-made soil strength deficiencies in variety of soil formations. Major applications of Compaction Grouting include densifying loose soils or fill voids caused by sinkholes, poorly compacted fills, broken utilities, improper dewatering, or soft ground tunneling excavation. Other applications include preventing liquefation, re-leveling settled structures, and using compaction grout bulbs as structural elements of minipiles or underpinning. In this paper, on the basis of the case history constructed in this year, a study has been performed to analyze the basic mechanism of the Compaction Grouting. Also, the effectiveness of the ground improvement and the bearing capacity of the Compaction Pile has been verified by the Cone Penetration Test(CPT) and Load Test. Relatively uniform Compaction grouting column could be maintained by planning the Quality Control in the course of grouting. And, the Quality Control Plan has been conceived using grout pressure, volume of grout and drilling depth.

  • PDF

나노 인덴테이션 시험에서의 탄소성 재료의 파일업/싱크인 특성 (The piling-up/sinking-in response of elasto-plastic materials in nano-indentation using sharp indenter)

  • 김병민;이찬주;이정민;이상진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1367-1372
    • /
    • 2007
  • Over the past decade, many computational researches have been performed to investigate quantitative relationships between load-displacement and material properties. But piling-up which causes errors to estimate mechanical material properties remains the most significant unresolved issue in nano-indentation test. This study has estimated quantitative aspects of the effects of material properties, especially work hardening exponent, on piling up/sinking in response of various materials. Using FE Analysis, piling up/sinking in response when material is indented by sharp indenter is investigated to evaluate the effects of material properties. From the FE analysis result, quantitative relationships between piling up/sinking in height and material properties is assessed using dimensional analysis which is used to define scaling variables and universal functions. And nano-indentaion test is performed to verify this relation on various materials. From the result of comparison with prediction from dimensional function and experiment, the work hardening exponent was found to have greater influence on the piling up/sinking in height during the nano-indentation than other material properties, such as elastic modulus and yield stress.

  • PDF

CGS에 의한 기초지반보강에 관한 연구 (A Study on the Ground Improvement by Compaction Grouting System)

  • 천병식;권형석
    • 한국철도학회논문집
    • /
    • 제2권4호
    • /
    • pp.9-19
    • /
    • 1999
  • The use of compaction grouting evolved in 1950's to correct structural settlement of buildings. Over the almost 50 years, the technology has been developed and is currently used in wide range of applications. Compaction grouting, the injection of a very stiff, 'zero-slump' mortar grout under relatively high pressure, displaces and compacts soils. It can effectively repair natural or man-made soil strength deficiencies in variety of soil formations. Major applications of compaction grouting include densifying loose soils or fill voids caused by sinkholes, poorly compacted fills, broken utilities, improper dewatering, or soft ground tunneling excavation. Other applications include preventing liquefaction, re-leveling settled structures, and using compaction grout bulbs as structural elements of minipiles or underpinning. In this paper, on the basis of the case history constructed in this year, a study has been performed to analyze the basic mechanism of the compaction grouting. Also, the effectiveness of the ground improvement and the bearing capacity of the compaction pile has been verified by the Cone Penetration Test(CPT) and Load Test. Relatively uniform compaction grouting column could be maintained by planning the quality control in the course of grouting. And, the Qualify Control Plan has been conceived using grout pressure, volume of grout and drilling depth.

  • PDF

팽이기초의 하중전달 메커니즘 (Stress delivery mechanism of Top Bases)

  • 정진혁;도준기;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.430-440
    • /
    • 2009
  • Top-Base Foundation(TBF) was developed in Japan as a factory made concrete product. It is actively used in 6,000 sites by the end of 1980s in Japan and applied for a domestic patent in 1985. It is a shallow foundation whose effectiveness is proven by many relevant researchers and engineers. TBF was introduced to Korea in 1991 and has been applied mainly to architectural structures to date. Currently, the effectiveness in bearing capacity and settlement of TBF is being underestimated for civil engineering structures. Characteristics of Top-Base Foundation studied in Japan and Korea is known as follows: (1) as concrete part and crushed stone behave together, they perform the function of rigid mat; (2) the conical part and pile part of TBF disperses load by interaction with the crushed stone; (3) by preventing lateral strain and differential settlement on lower ground, it improves bearing capacity and constrains settlement at the same time. In Korea, it is used mostly in clayey soft grounds. The formula of bearing capacity and settlement of TBF suggested in Japan give the values of the underestimated. bearing capacity while its settlement is overestimated in comparison with the values measured from the field loading test. Therefore, in this study, the stress delivery mechanism of Top-Base Foundation developed in Japan and Floating Top Base developed in Korea is investigated through numerical analysis and laboratory model test.

  • PDF