• Title/Summary/Keyword: piezoelectric transducer

Search Result 391, Processing Time 0.034 seconds

Study on Fiber Polarimetric Vibration Sensor Based on Polarization-Maintaining Photonic Crystal Fiber (편광유지 광자결정 광섬유 기반 편광 간섭형 진동 센서)

  • Kim, Young-Suk;Park, Kyongsoo;Lee, Yong Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.13-18
    • /
    • 2015
  • In this paper, we implemented a polarimetric vibration sensor using a Sagnac birefringence interferometer composed of polarization-maintaining photonic crystal fiber(PM-PCF). By changing the amplitude and frequency of vibration applied to PM-PCF employed as the sensor head of the proposed sensor, sensor responses to various types of vibration were investigated. First, the vibration characteristic of the sensor was explored for a single frequency in a frequency range from 1 to 3000Hz with a cylindrical piezoelectric transducer, and then the sensor response to naturally damped vibration was examined by utilizing a metal cantilever. It was experimentally observed that the sensor output signal was deteriorated by more than 3dB at ~1900Hz in the single frequency vibration measurement with a minimum detectable strain perturbation of ${\sim}1.34n{\varepsilon}/Hz^{1/2}$ at 1500Hz and the peak value of the sensor output signal was proportional to the strength of initially applied stress in the naturally damped vibration measurement.

Development of intelligent model to predict the characteristics of biodiesel operated CI engine with hydrogen injection

  • Karrthik, R.S.;Baskaran, S.;Raghunath, M.
    • Advances in Computational Design
    • /
    • v.4 no.4
    • /
    • pp.367-379
    • /
    • 2019
  • Multiple Inputs and Multiple Outputs (MIMO) Fuzzy logic model is developed to predict the engine performance and emission characteristics of pongamia pinnata biodiesel with hydrogen injection. Engine performance and emission characteristics such as brake thermal efficiency (BTE), brake specific energy consumption (BSEC), hydrocarbon (HC), carbon monoxide (CO), carbon dioxide ($CO_2$) and nitrous oxides ($NO_X$) were considered. Experimental investigations were carried out by using four stroke single cylinder constant speed compression ignition engine with the rated power of 5.2 kW at variable load conditions. The performance and emission characteristics are measured using an Exhaust gas analyzer, smoke meter, piezoelectric pressure transducer and crank angle encoder for different fuel blends (Diesel, B10, B20 and B30) and engine load conditions. Fuzzy logic model uses triangular and trapezoidal membership function because of its higher predictive accuracy to predict the engine performance and emission characteristics. Computational results clearly demonstrate that, the proposed fuzzy model has produced fewer deviations and has exhibited higher predictive accuracy with acceptable determination correlation coefficients of 0.99136 to 1 with experimental values. The developed fuzzy logic model has produced good correlation between the fuzzy predicted and experimental values. So it is found to be useful for predicting the engine performance and emission characteristics with limited number of available data.

Size-based separation of microscale droplets by surface acoustic wave-induced acoustic radiation force (표면파 유도 음향방사력을 이용한 미세액적의 크기 선별)

  • Mushtaq, Ali;Beomseok, Cha;Muhammad, Soban Khan;Hyunwoo, Jeon;Song Ha, Lee;Woohyuk, Kim;Jeongu, Ko;Jinsoo, Park
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.19-26
    • /
    • 2022
  • In droplet microfluidics, precise droplet manipulation is required in numerous applications. This study presents ultrasonic surface acoustic wave (USAW)-based microfluidic device for label-free droplet separation based on size. The proposed device is composed of a slanted-finger interdigital transducer on a piezoelectric substrate and a polydimethylsiloxane microchannel placed on the substrate. The microchannel is aligned in the cross-type configuration where the USAWs propagate in a perpendicular direction to the flow in the microchannel. When droplets are exposed to an acoustic field, they experience the USAW-induced acoustic radiation force (ARF), whose magnitude varies depending on the droplet size. We modeled the USAW-induced ARF based on ray acoustics and conducted a series of experiments to separate different-sized droplets. We found that the experimental results were in good agreement with the theoretical estimation. We believe that the proposed method will serve as a promising tool for size-based droplet separation in a label-free manner.

Fabrication of a PMN-PZT needle hydrophone for photoacoustic imaging (광음향 영상화를 위한 PMN-PZT 바늘형 수중청음기 제작)

  • Fan, Xiaofeng;Cao, Yonggang;Ha, Kanglyeol;Kim, Moojoon;Kang, Hyun Wook;Oh, Junghwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.175-182
    • /
    • 2016
  • For application to several MHz photoacoustic imaging systems, a needle hydrophone was designed and fabricated by using PMN-PZT piezoelectric single crystal, and its characteristics were evaluated through comparison with a commercial PVDF(Polybinylidene Fluoride) hydrophone of which receiving sensitivity is known. The simulation using the KLM model results show that the peak receiving impulse response for $50{\Omega}$ terminating impedance of the fabricated hydrophone is -261.6 dB re $1V/{\mu}Pa$ and the frequency response is relatively flat over 2 ~ 12 MHz with fluctuation less than 5 dB. The measurement results using tone burst signals also show that it has higher (ave. 10.9 dB) sensitivity than the commercial hydrophone in 2 ~ 8 MHz, and the receiving sensitivity of $-255.8{\pm}2.8$ dB re $1V/{\mu}Pa$ was measured for the fabricated hydrophone. In addition, it is known that the photoacoustic signals and the image of a hair obtained by a mechanical scanned photoacoustic imaging system with the fabricated hydrophone were bigger and better than those obtained with the commercial hydrophone.

Vibration Characteristics of a Wire-Bonding Ultrasonic Horn (와이어 본딩용 초음파 혼의 진동 특성)

  • Kim, Young Woo;Yim, Vit;Han, Daewoong;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.2
    • /
    • pp.227-233
    • /
    • 2014
  • This study investigates the vibration characteristics of a wire-bonding piezoelectric transducer and ultrasonic horn for high-speed and precise welding. A ring-type piezoelectric stack actuator is excited at 136 kHz to vibrate a conical-type horn and capillary system. The nodal lines and amplification ratio of the ultrasonic horn are obtained using a theoretical analysis and FEM simulation. The vibration modes and frequencies close to the driving frequency are identified to evaluate the bonding performance of the current wire-bonder system. The FEM and experimental results show that the current wire-bonder system uses the bending mode of 136 kHz as the principal motion for bonding and that the transverse vibration of the capillary causes the bonding failure. Because the major longitudinal mode exists at 119 kHz, it is recommended that the design of the current wire-bonding system be modified to use the major longitudinal mode at the excitation frequency and to minimize the transverse vibration of capillary in order to improve the bonding performance.

Guide for Processing of Textured Piezoelectric Ceramics Through the Template Grain Growth Method

  • Temesgen Tadeyos Zate;Jeong-Woo Sun;Nu-Ri Ko;Hye-Lim Yu;Woo-Jin Choi;Jae-Ho Jeon;Wook Jo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.341-350
    • /
    • 2023
  • The templated grain growth (TGG) method has gained significant attention for its ability to produce highly textured piezoelectric ceramics with significantly enhanced performance, making it a promising method for transducer and actuator applications. However, the texturing process using the TGG method requires the optimization of multiple steps, which can be challenging for beginners in this field. Therefore, in this tutorial, we provide an overview of the TGG method mainly based on our previous published works, including its various processing steps such as synthesizing anisotropic-shaped templates with size and size distribution control using the molten salt synthesis technique, tape casting, and identifying key factors for proper alignment of the templates in the target matrix system. Our goal is to provide a resource that can serve as a basic reference for researchers and engineers looking to improve their understanding and utilization of the TGG method for producing textured piezoelectric ceramics.

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Dual Resonance Design of a Ultrasonic Transducer Using a Single Acoustic Matching Layer - (어종식별을 위한 광대역 초음파 변환기의 설계 II - 단일음향정합층을 이용한 이중공진형 변환기의 설계 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.74-84
    • /
    • 1998
  • A doubly resonant ultrasonic transducer has been designed as an attempt to increase the bandwidth of underwater transducers. The dual resonance conditions were accomplished by attaching a single acoustic matching layer on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and a prestress bolt. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedances and thicknesses of the head, tail and matching layers in the water tank. Two distinct resonance peaks in the transmitting voltage response(TVR) of a developed transducer were observed at 34.3 and 40.4 kHz, respectively, with the difference frequency of 6.1kHz and the center frequency of 37.2kHz. The values of TVR at these frequencies were 136.5 dB re $1\;\muPa/V$ at 34.3 kHz and 136.8 dB re $1\;\muPa/V$ at 40.4 kHz, respectively. Reasonable agreement between the experimental results and the numerical results was achieved. From this result, it is expected that the generation of the distinct resonances at any two desired frequencies can be achieved through the proper choice of the matching layer to provide the impedance transformation between the transducer and the medium.

  • PDF

Analysis of Acoustic Reflectors for SAW Temperature Sensor and Wireless Measurement of Temperature (SAW 온도센서용 음향 반사판 분석 및 무선 온도 측정)

  • Kim, Ki-Bok;Kim, Seong-Hoon;Jeong, Jae-Kee;Shin, Beom-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.54-62
    • /
    • 2013
  • In this study, a wireless and non-power SAW (surface acoustic wave) temperature sensor was developed. The single inter-digital transducer (IDT) of SAW temperature sensor of which resonance frequency is 434 MHz was fabricated on $128^{\circ}$ rot-X $LiNbO_3$ piezoelectric substrate by semiconductor processing technology. To find optimal acoustic reflector for SAW temperature sensor, various kinds of acoustic reflectors were fabricated and their reflection characteristics were analyzed. The IDT type acoustic reflector showed better reflection characteristic than other reflectors. The wireless temperature sensing system consisting of SAW temperature sensor with dipole antenna and a microprocessor based control circuit with dipole antenna for transmitting signal to activate the SAW temperature sensor and receiving the signal from SAW temperature sensor was developed. The result with wireless SAW temperature sensing system showed that the frequency of SAW temperature sensor was linearly decreased with the increase of temperature in the range of 40 to $80^{\circ}C$ and the developed wireless SAW temperature sensing system showed the excellent performance with the coefficient of determination of 0.99.

Fabrication of the photon scanning tunneling microscope with constant intensity mode (일정광량 방식의 광자주사현미경 제작)

  • Kim, Ji-Taek;Choi, Wan-Hae;Jo, Jae-Heung;Chang, Soo;Kim, Dal-Hyun;Koo, Ja-Yong;Chung, Seung-Tae
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.195-200
    • /
    • 1999
  • We made sharp optical fiber tips with less than 100 nm diameter by using the heating and pulling method with a good repetition and fabricated the photon scanning tunneling microscope (PSTM) using constant intensity mode. The 3-dimensional PZT (Piezoelctric transducer) scanner made of a long PZT tube is consisted of three divided parts, that is, a pair of $\pm$ x and a pair of $\pm$y scanning parts and a z scanning part for the fine approach and scanning. The scanning dimension is 1.43 $\mu\textrm{m}$$\times$1.76 $\mu\textrm{m}$. The height of a optical tip to maintain a constant height within $1/{\lambda}_0$ (${\lambda}_0$ is the incident wavelength) from surface of a specimen to a optical tip is controlled automatically by using the electric feedback circuit. The 3-dimensional shape of standing evanescent waves generated on the surface of a dove prism was measured successfully by using the constant intensity mode PSTM.

  • PDF

Development of Battery-free SAW Integrated Microsensor for Real Time Simultaneous Measurement of Humidity and $CO_2$ component (습도와 $CO_2$ 농도의 실시간 동시감지를 위한 무전원 SAW 기반 집적 센서 개발)

  • Lim, Chun-Bae;Lee, Kee-Keun;Wang, Wen;Yang, Sang-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2009
  • A 440MHz wireless and passive surface acoustic wave (SAW) based chemical sensor was developed on a $41^{\circ}YX\;LiNbO_3$ piezoelectric substrate for simultaneous measurement of $CO_2$ gas and relative humidity (RH) using a reflective delay line pattern as the sensor element. The reflective delay line is composed of an interdigital transducer (IDT) and several shorted grating reflectors. A Teflon AF 2400 and a hydrophilic $SiO_2$ layer were used as $CO_2$ and water vapor sensitive films. The coupling of mode (COM) modeling was conducted to determine optimal device parameters prior to fabrication. According to simulation results, the device was fabricated and then wirelessly measured using the network analyzer. The measured reflective coefficient $S_{11}$ in the time domain showed high signal/noise (S/N) ratio, small signal attenuation, and few spurious peaks. In the $CO_2$ and humidity testing, high sensitivity ($2^{\circ}/ppm$ for $CO_2$ detection and $7.45^{\circ}/%$RH for humidity sensing), good linearity and repeatability were observed in the $CO_2$ concentration ranges of $75{\sim}375ppm$ and humidity levels of $20{\sim}80%$RH. Temperature and humidity compensations were also investigated during the sensitivity evaluation process.

  • PDF