• Title/Summary/Keyword: piezoelectric signal

Search Result 228, Processing Time 0.035 seconds

Study of Active Damping Boring Bar Using Piezoelectric Actuator for Small Boring Process (압전 액추에이터를 이용한 소구경 능동 방진 보링바 기초연구)

  • Guo, Yang-Yang;Hong, Jun-Hee;Song, Doo-Sang
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.658-664
    • /
    • 2013
  • In this paper, we present a case study of vibration suppression based on the application of active damping to the small boring process of a boring bar with diameter below ${\Phi}12$. The proposed active damping system consists of an acceleration sensor for real-time monitoring of the vibration signal, a driver for phase control in a computer program, and piezoelectric actuators for damping. In this system, the vibration signals are detected by the acceleration sensor and sent to the computer as an input. The phase shift parameter of the natural frequency of the input signal is sent to the data acquisition board in the computer and calculated by the phase control program. This study confirmed the effectiveness of this damping system, and it opens up the possibility of the development of active damping systems for small boring processes.

Autonomous hardware development for impedance-based structural health monitoring

  • Grisso, Benjamin L.;Inman, Daniel J.
    • Smart Structures and Systems
    • /
    • v.4 no.3
    • /
    • pp.305-318
    • /
    • 2008
  • The development of a digital signal processor based prototype is described in relation to continuing efforts for realizing a fully self-contained active sensor system utilizing impedance-based structural health monitoring. The impedance method utilizes a piezoelectric material bonded to the structure under observation to act as both an actuator and sensor. By monitoring the electrical impedance of the piezoelectric material, insights into the health of the structured can be inferred. The active sensing system detailed in this paper interrogates a structure utilizing a self-sensing actuator and a low cost impedance method. Here, all the data processing, storage, and analysis is performed at the sensor location. A wireless transmitter is used to communicate the current status of the structure. With this new low cost, field deployable impedance analyzer, reliance on traditional expensive, bulky, and power consuming impedance analyzers is no longer necessary. A complete power analysis of the prototype is performed to determine the validity of power harvesting being utilized for self-containment of the hardware. Experimental validation of the prototype on a representative structure is also performed and compared to traditional methods of damage detection.

Thermopiezoelectric Cantilever for Probe-Based Data Storage System

  • Jang, Seong-Soo;Jin, Won-Hyeog;Kim, Young-Sik;Cho, Il-Joo;Lee, Dae-Sung;Nam, Hyo-Jin;Bu, Jong. U.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.4
    • /
    • pp.293-298
    • /
    • 2006
  • Thermopiezoelectric method, using poly silicon heater and a piezoelectric sensor, was proposed for writing and reading in a probe based data storage system. Resistively heated tip writes data bits while scanning over a polymer media and piezoelectric sensor reads data bits from the self-generated charges induced by the deflection of the cantilever. 34${\times}$34 array of thermopiezoelectric nitride cantilevers were fabricated by a single step wafer level transfer method. We analyzed the noise level of the charge amplifier and measured the noise signal. With the sensor and the charge amplifier 20mn of deflection could be detected at a frequency of 10KHz. Reading signal was obtained from the cantilever array and the sensitivity was calculated.

Development of Optical Pickup for ElectroAcoustic Guitar (일렉트로어쿠스틱 기타용 광 픽업의 개발)

  • Shin, Bong-Hi;Park, Young-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.417-422
    • /
    • 2014
  • A guitar pickup is a transducer that converts string vibration to an electrical signal. The magnetic and piezo pickups are the most commonly used for the respective electric and electroacoustic guitars. The magnetic pickups are prone to magnetic interference between the steel strings and permanent magnets, while the piezo ones are not free from signal inference between the strings. Thus, this paper presents the development of an optical pickup for the electroacoustic guitar. The proposed optical pickup has the top-to-bottom structure. It uses two of Infrared (IR) Light Emitting Diode (LED) and one photodetector. The developed optical pickup is subjected to the evaluation with commonly used piezoelectric pickup. It becomes obvious that SNR with the optical pickup is increased by 45 percent in average, compared with the piezoelectric pickup. It can be concluded that the developed optical pickup has a potential to be applied to the acoustic guitar.

Development of Error Compensation System and On the Machine Measurement System for Ultra-Precision Machine (초정밀가공기용 오차보상시스템 및 기상측정장치 개발)

  • 이대희;나혁민;오창진;김호상;민흥기;김민기;임경진;김태형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.599-603
    • /
    • 2003
  • This paper present an error compensation system and On-Machine Measurement(OMM) system for improving the machining accuracy of ultra-precision lathe. The Fast-Tool-Servo(FTS) driven by a piezoelectric actuator is applied for error compensation system. The controller is implemented on the 32bit DSP for feedback control of piezoelectric actuator. The control system is designed to compensates three kinds of machining errors such as the straightness error of X-axis slide, the thermal growth error of the spindle. and the squareness between spindle and X-axis slide. OMM is preposed to measure the finished profile of workpiece on the machine-tool using capacitive sensor with highly accurate ruby tip probe guided by air bearing. The data acquisition system is linked to the CNC controller to get the position of each axis in real-time. Through the experiments, it is founded that the thermal growth of spindle and tile squareness error between spindle and X-axis slide influenced to machining error more than straightness error of X-axis slide in small travel length. These errors were simulated as a sinusoidal signal which has very low frequency and the FTS could compensate the signal less than 30 m. The implemented OMM system has been tested by measuring flat surface of 50 mm diameter and shows measurement error less than 400 mm

  • PDF

Predictive model of fatigue crack detection in thick bridge steel structures with piezoelectric wafer active sensors

  • Gresil, M.;Yu, L.;Shen, Y.;Giurgiutiu, V.
    • Smart Structures and Systems
    • /
    • v.12 no.2
    • /
    • pp.97-119
    • /
    • 2013
  • This paper presents numerical and experimental results on the use of guided waves for structural health monitoring (SHM) of crack growth during a fatigue test in a thick steel plate used for civil engineering application. Numerical simulation, analytical modeling, and experimental tests are used to prove that piezoelectric wafer active sensor (PWAS) can perform active SHM using guided wave pitch-catch method and passive SHM using acoustic emission (AE). AE simulation was performed with the multi-physic FEM (MP-FEM) approach. The MP-FEM approach permits that the output variables to be expressed directly in electric terms while the two-ways electromechanical conversion is done internally in the MP-FEM formulation. The AE event was simulated as a pulse of defined duration and amplitude. The electrical signal measured at a PWAS receiver was simulated. Experimental tests were performed with PWAS transducers acting as passive receivers of AE signals. An AE source was simulated using 0.5-mm pencil lead breaks. The PWAS transducers were able to pick up AE signal with good strength. Subsequently, PWAS transducers and traditional AE transducer were applied to a 12.7-mm CT specimen subjected to accelerated fatigue testing. Active sensing in pitch catch mode on the CT specimen was applied between the PWAS transducers pairs. Damage indexes were calculated and correlated with actual crack growth. The paper finishes with conclusions and suggestions for further work.

Implementation of a Respiration Measurement System Based on a Nonrestraint Approach (무구속 방식의 호흡 측정 시스템 구현)

  • Cho, Seok-Hyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.33-41
    • /
    • 2014
  • In this paper, we implemented a system to measure respiration rate with nonrestraint sensors comfortable for people to do their everyday life. The proposed system consists of a pad covered with a Piezoelectric sensor, a respiration measuring device able to send the signal data after amplifying and filtering the source signals to the viewer, a viewer providing sensor data visualization and implementing the respiration measuring algorithm. The algorithm is based on a breathing cycle with the local peak points extracted from threshold on sensor data. Respiration measurements on 3 subjects were performed by changing moving averages and thresholds. The proposed system showed less than 5% error rate when proper moving averages are N=50~60 and a range of thresholds is 800~1300. The system will contribute to preventing suffocation during sleep for infants and the elderly living alone.

Development of New Stacked Element Piezoelectric Polyvinylidene Fluoride Pressure Sensor for Simultaneous Heartbeat and Respiration Measurements (PVDF 압전소자를 이용한 심장박동 및 호흡수 동시측정센서개발)

  • Park, Chang-Yong;Kweon, Hyun-Kyu;Lee, So-Jin;Manh, Long-Nguyen
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.4
    • /
    • pp.100-108
    • /
    • 2019
  • In this paper, a new stacked element pressure sensor has proposed for heartbeat and respiration measurement. This device can be directly attached to an individual's chest; heartbeat and respiration are detected by the pulsatile vibration and deformation of the chest. A key feature of the device is the simultaneous measurement of heart rate and respiration. The structure of the sensor consists of two stacked elements, in which one element includes one polyvinylidene fluoride (PVDF) thin film bonded on polydimethylsiloxane (PDMS) substrate. In addition, for the measurement and signal processing, the electric circuit and the filter are simply constructed with an OP-amp, resistance, and a capacitor. One element (element1, PDMS) maximizes the respiration signal; the other (element2, PVDF) is used to measure heartbeat. Element1 and element2 had sensitivity of 0.163V/N and 0.209V/N, respectively, and element2 showed improved characteristics compared with element1 in response to force. Thus, element1 and element2 were optimized for measuring respiration heart rate, respectively. Through mechanical and vivo human tests, this sensor shows the great potential to optimize the signals of heartbeat and respiration compared with commercial devices. Moreover, the proposed sensor is flexible, light weight, and low cost. All of these characteristics illustrate an effective piezoelectric pressure sensor for heartbeat and respiration measurements.

A Design and Manufacturing of Two Types of Micro-grippers using Piezoelectric Actuators for the Micromanipulation (미세 조작을 위한 압전 구동 집게의 설계 및 제작)

  • 박종규;문원규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.246-250
    • /
    • 2003
  • In this study, two new types of micro-grippers in which micro-fingers are actuated by piezoelectric multi-layer benders and stacks are introduced for the manipulation of micrometer-sized objects. First, we constructed a 3-chopstick-mechanism tungsten gripper, which is composed of three chopsticks: two are designed to grip micro-objects, and tile third is used to help grasp and release the objects through overcoming especially electrostatic force among some surface effects including electrostatic, van der Waals forces and surface tension. Second, a 2-chopstick-mechanism silicon micro-gripper that uses an integrated force sensor to control the gripping force was developed. The micro-gripper is composed of a piezoelectric multilayer bender for actuating the gripper fingers, silicon fingertips fabricated by use of silicon-based micromachining, and supplementary supports. The micro-gripper is referred to as a hybrid-type micro-gripper because it is composed of two main components; micro-fingertips fabricated using micromachining technology to integrate a very sensitive force sensor for measuring the gripping force, and piezoelectric gripper finger actuators that are capable of large gripping forces and moving strokes. The gripping force signal was found to have a sensitivity of 667 N/V. To the design of each of components of both of the grippers. a systematic design approach was applied, which made it possible to establish the functional requirements and design parameters of the micro-grippers. The micro-grippers were installed on a manual manipulator to assess its performance in tasks such as moving micro-objects from one position to a desired position. The experiment showed that the micro-grippers function effectively.

  • PDF

Investigation of Impact Detection Characteristics of Piezoelectric Paint According to Boundary Conditions (구조물의 경계조건에 따른 압전 페인트 센서의 충격검출 특성 평가)

  • Park, Seung-Bok;Han, Dae-Hyun;Kang, Lae-Hyong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1335-1343
    • /
    • 2014
  • Piezoelectric paint can be used to monitor vibrations or impacts occurring in large engineering structures such as ships and airplanes. This study investigated the impact detection characteristics of a piezoelectric paint sensor and possible errors in detecting impacts according to boundary conditions. The piezoelectric paint sensor used in this study was coated on an aluminum plate with four different electrode areas. After the occurrence of the poling process, the output voltages from the paint sensors were obtained when impact occurred in a certain sensor region. The experimental results revealed a large difference in magnitudes between the sensor signal in the impact region and those in the other regions, and this relation was maintained regardless of the changes in the boundary conditions.