• Title/Summary/Keyword: physiological measure

Search Result 336, Processing Time 0.025 seconds

The change of pupil size after viewing three dimensional TV (2안식 입체TV 주시전후의 동공면적의 변화)

  • Cho, Am
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.25-32
    • /
    • 1995
  • The physiological change of eyes while viewing 3D TV was investigated. The change of pupil size was used as the measure of evaluation. The results are as follows : (1) The pupil size decreases after viewing 2D and 3D image and the the tendency is more critical with 3D images. (2) The indoor illumination has a significant effect on the pupil size in both 2D and 3D cases. (3) Less chage of pupil size were observed under the indoor illumination. Thus, if we only focus on the visual load on the eye, for viewing 3D image, it will be better to use indoor illumination.

  • PDF

Correlation Study between Brain Atrophy and Risk Factors for Cerebrovascular Disease (노화에 관련된 뇌위축과 뇌혈관 질환의 위험인자와의 상관관계 연구)

  • Ko, Heung;Moon, Jo Ho;Kim, Ki Tae;Shin, Seon Mi
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.2
    • /
    • pp.200-205
    • /
    • 2014
  • Based on the way we have created to measure the brain atrophy of pons, frontal lobe, sylvian fissure, ventricle, cerebellum, we analyzed the correlation with age. We confirmed whether the brain atrophy due to hypertension, diabetes, hyperlipidemia, drinking, smoking is increasing. Brain deficiency(髓海不足), Brain dissatisfied(腦爲之不滿), Brain Consume(腦髓消烁) listed in Donguibogam(東醫寶鑑) have to be diagnosed with brain atrophy induced by developmental disorders, diseases, aging. Sylvian fissure is well reflected brain atrophy progressed by aging. And brain atrophy increased in hypertension, diabetes, hyperlipidemia, drinking, smoking is well reflected at Sylvian fissure.

Case Report of Both Anterior Cerebral Artery Territory Infarction (양측 전대뇌동맥영역 뇌경색 환자의 증례보고)

  • Yun, Jong Min
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.73-79
    • /
    • 2016
  • It was aimed to report a case of both anterior cerebral artery territory infarction patient improved by korean medical treatment. The patient was diagnosed by brain magnetic resonance imaging(MRI) and magnetic resonance angiography(MRA). The symptoms were quadriplegia, urinary frequency, urinary incontinence and abulia. I applied herbal medicine, acupuncture, moxibustion, pharmacopuncture, cupping and physical exercise therapy. As a result of them, the symptoms of the patient were improved considerably. Status of the patient was evaluated by manaul muscle test(MMT), modified barthel index(MBI) and functional independence measure(FIM) and medical interview. MBI score was changed from 35 to 95 and FIM score was changed from 66 to 115. Therefore this report suggests that korean medical treatment could be effective to the anterior cerebral artery territory infarction.

Remote Vital Signal Monitoring System Based on Wireless Sensor Network Using Ad-Hoc Routing

  • Walia Gaurav;Lee Young-Dong;Chung Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.2
    • /
    • pp.67-70
    • /
    • 2006
  • A distributed healthcare monitoring system prototype for clinical and trauma patients was developed, using wireless sensor network node. The proposed system aimed to measure various vital physiological health parameters like ECG and body temperature of patients and elderly persons, and transfer his/her health status wirelessly in Ad-hoc network to remote base station which was connected to doctor's PDA/PC or to a hospital's main Server using wireless sensor node. The system also aims to save the cost of healthcare facility for patients and the operating power of the system because sensor network is deployed widely and the distance from sensor to base station was shorter than in general centralized system. The wireless data communication will follow IEEE 802.15.4 frequency communication with ad-hoc routing thus enabling every motes attached to patients, to form a wireless data network to send data to base-station, providing mobility and convenience to the users in home environment.

Analysis of Inyoung-Chongu Pulse Measured on Normal People (정상인에게서 측정되는 인영촌구맥의 경향성 분석)

  • Choi, Chan-Hun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.158-164
    • /
    • 2010
  • The aim of this study is to examine the reliability of Inyoung-Chongu pulse diagnosis by analyzing Inyoung-Chongu pulse measured on normal people. I measure the size of Inyoung & Chongu pulse, ratio of Inyoung to Chongu, and ratio of Chongu to Inyoung on 50 normal people. Inyoung pulse of normal people is $6.44{\pm}1.62$ volt and Chongu pulse of normal people is $6.81{\pm}1.70$ volt. The ratio of Inyoun to Chongu is $1.03{\pm}0.50$ and that of Chongu to Inyoung is $1.12{\pm}0.41$. Through this experiment, I conclude that the Inyoung-Chongu pulse diagnosis is reproducible on normal people and can develop pulse diagnosis device through comparison between Inyoung and Chongu pulse.

Study on the Benefits of Germinated Seed of Rhynchosia Volubilis on Osteosarcoma HOS-TE85 Related to Bone Morphogenesis and Effective Abstraction Research (발아 서목태(發芽 鼠目太)의 추출방법별 인중합체 함량과 골형성 관련 유전자(HOS-TE85)의 활성화 연구)

  • Lee Seok-Won;Cha Yun-Yeop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1317-1322
    • /
    • 2005
  • The aim of this study was to find out the effectiveness on germinated seed of Rhynchosia Volubilis for Female Bone Morphogenesis. For this purpose, We compared two methods. water extract and alcohol extract using germinated Rhynchosia Volubilis(GRV) according to germinating days were conducted to measure the polyphosphate contents and investigate HOS-TE85 propagation rate. Both water and alcohol extract two methods were not toxicant. And if not excessively treated, alcohol extract rate were more about $5{\sim}15$ times than water extract rate. So usually water extract were better than alcohol extract. but in case of osteoporosis, alcohol extract were effective.

Noise Reduction of PPG Signal During Free Movements Using Adaptive SFLC(Scaled Fourier Linear Combiner) (적응 SFLC(Scaled Fourier Linear Combiner)를 이용한 활동 중의 PPG 신호의 잡음 감소)

  • Kim, Sung-Min;Cha, Eun-Jong;Kim, Deok-Won;Yoo, Jae-Ha;Kim, Dong-Yon;Kim, Soo-Chan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.138-141
    • /
    • 2006
  • Blood flow is one of vital signals related to human physiological information. Photoplethysmograph (PPG) has been used to measure indirectly heart rate, blood oxygen saturation ($SpO_2$), and so on. Because PPG signal is weak and sensitive to motion artifacts, it is very important to continuously obtain stable PPG signal during free movement. In this study, we applied the scaled Fourier linear combiner (SFLC) using both the adaptive filter and FLC to remove effectively the motion artifacts as well as background noise in the real time without additional signal correlated with motion from a accelerometer. The proposed method would be useful to reduce the movement and background noise which are not synchronized with heart rate.

A STUDY OF ELECTRONIC DEVICE FOR THE MEASURING THE TONGUE PRESSURE (설압력 측정품구에 관한 연구)

  • Lee, Ho-Yong;Kim, ki-Hwan;Chung, Kyung-Hoon
    • The Journal of the Korean dental association
    • /
    • v.15 no.12
    • /
    • pp.1027-1030
    • /
    • 1977
  • It has been widely believed that the exact measurement of the forces exerted on teeth and its structures by the lingual and perioral musculatures such as lip, cheek and tongue is important and significant in dentistry. Such measuring, moreover, is highly emphasized the importance of the fact that it can be of much help to study the physiological function displayed in the oral cavity. Recognizing the importance of measuring the pressures, the author has devised an electronic device consisting of pressure transducers utilizing reistance-strnain gauges. This electronic strain gauge was very easy to manipulate and its scale error was extremely minimized, unaffected by mouth temperature, mosture and external forces Author was able to read its results with attached meter without using calibration chart. Futhermore, the sensitivity of this electronic device was extremely high, Thus it facilitated to measure a force from 0 to 230 grams.

  • PDF

A Study on Optical Properties in Biological Tissue Using A Photon Path Diffusion Model (광 항적경로 모델을 이용한 피하조직에서의 광 특성에 관한 연구)

  • 임현수
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.265-274
    • /
    • 1994
  • This paper proposes a method of noninvasive reflectance light to measure the blood fractional volume (Vb) and oxygen saturation ($SO_2$) of biological tissue. We chose the red light of 660nm and infrared light of 880nm. In Vivo reflectance data were obtained by the physiological changes front the surface of the skin over the calf in human subject. The reflected light intensity from different layers within a biological tissue was measured by specially designed reflectometer to apply photon path diffusion model. The collected data represent the changes of blood (ractional volume and oxygen saturation at each reflected light wavelengths. The data evaluation was assessed by examining the slopes of the plotted indices for the changes in oxygen saturation and blood (ractional volume. The results presented in this paper claim that light reflectance can separately discriminate the change of blood volume and that of oxygenation in muscle and also in skin.

  • PDF

Comprehensive evaluation method for user interface design in nuclear power plant based on mental workload

  • Chen, Yu;Yan, Shengyuan;Tran, Cong Chi
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.453-462
    • /
    • 2019
  • Mental workload (MWL) is a major consideration for the user interface design in nuclear power plants (NPPs). However, each MWL evaluation method has its advantages and limitations, thus the evaluation and control methods based on multi-index methods are needed. In this study, fuzzy comprehensive evaluation (FCE) theory was adopted for assessment of interface designs in NPP based on operators' MWL. An evaluation index system and membership functions were established, and the weights were given using the combination of the variation coefficient and the entropy method. The results showed that multi-index methods such as performance measures (speed of task and error rate), subjective rating (NASA-TLX) and physiological measure (eye response) can be successfully integrated in FCE for user interface design assessment. The FCE method has a correlation coefficient compared with most of the original evaluation indices. Thus, this method might be applied for developing the tool to quickly and accurately assess the different display interfaces when considering the aspect of the operators' MWL.