• Title/Summary/Keyword: physiological measure

Search Result 332, Processing Time 0.025 seconds

Instrumentation and Software for Analysis of Arabidopsis Circadian Leaf Movement

  • Kim, Jeong-Sik;Nam, Hong-Gil
    • Interdisciplinary Bio Central
    • /
    • v.1 no.1
    • /
    • pp.5.1-5.4
    • /
    • 2009
  • This article is an addendum to the authors’ previous article (Kim, J. et al. (2008) Plant Cell 20, 307-319). The instrumentation and software described in this article were used to analyze the circadian leaf movement in the previous article. Here, we provide detailed and practical information on the instrumentation and the software. The source code of the LMA program is freely available from the authors. The circadian clock regulates a wide range of cyclic physiological responses with a 24 hour period in most organisms. Rhythmic leaf movement in plants is a typical robust manifestation of rhythms controlled by the circadian clock and has been used to monitor endogenous circadian clock activity. Here, we introduce a relatively easy, inexpensive, and simple approach for measuring leaf movement circadian rhythms using a USB-based web camera, public domain software and a Leaf Movement Assay (LMA) program. The LMA program is a semi-automated tool that enables the user to measure leaf lengths of individual Arabidopsis seedlings from a set of time-series images and generates a wave-form output for leaf rhythm. This is a useful and convenient tool for monitoring the status of a plant's circadian clock without an expensive commercial instrumentation and software.

Case Report of Ascites in Alcoholic Liver Cirrhosis (복수를 동반한 알코올성 간경변증 환자 치험 1례)

  • Choi, Ga-Young;Kim, Soo-Yeon;Kim, Byoung-Woo;Jee, Hyon-Chol;Sun, Seung-Ho;Lee, Seon-Goo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1161-1165
    • /
    • 2009
  • Daekumeumja is a herb-medication which has been used for alcoholic damage. This is a report about the effect of Daekumeumja on Ascites in alcoholic liver cirrhosis. The study of abdominal CT and ultrasonography were performed to evaluate the volume change of ascites. And blood tests were done to measure the liver's and kidney's functions. Reduction of ascites is proved by abdominal CT & ultrasonography. And lab findings of liver functions showed improvement. This study suggests that Daekumeumja is probably effective in the treatment of ascites in alcoholic liver cirrhosis.

Temperature Changes in both Palm before and after Herbal Medicine Administration for Palmar Hyperhidrosis (수부 다한증에서 한약치료 후 양수부의 온도 변화)

  • Lee Si Hyeong;Park Byong Min;Yu Yun Cho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1343-1346
    • /
    • 2003
  • Monitoring the skin temperature changes of the palm during video endoscopic thoracic sympathicotomy has been used as a measure of the success of the surgery for palmar hyperhidrosis. So we measured palmar skin temperature on both sides after administration of herbal medicine to learn whether we can use it as a indicator of herbal medicine effect, and to see it's mechanism. Seven patients (15 to 19 years old) with palmar hyperhidrosis underwent administration of herbal medicine. The palmar skin temperature was measured by comparing the changes of skin temperature before and after administration of herbal medicine for palmar hyperhidrosis. After the administration, temperature of the left palm was elevated(before. 26.16±2.13℃ vs. after. 30.62±1.84℃, p<0.05), and temperature of the right palm was also elevated(before. 26.14±2.28℃ vs. after. 30.91 ±1.67℃, p<0.05). These results suggest that the administration of herbal medicine is not only the symptoms of hyperhidrosis abolished but also the skin temperature of palm is elevated.

The Effect of K-MBSR Program on Stress, Stress Coping Style, Depression, Anger and Sleep of Middle Aged Women (한국형 마음챙김 명상 프로그램이 중년여성의 스트레스, 스트레스 대처방식, 우울, 분노 및 수면에 미치는 효과)

  • Park, Jeong Min;Choi, In-Ryoung
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.2
    • /
    • pp.194-206
    • /
    • 2016
  • Purpose: The purpose of this study was to examine a Korean Mindfulness Based Stress Reduction (K-MBSR) program for middle aged women and to verify the program's effectiveness on stress, stress coping style, depression, anger and sleep. Methods: Fifty-two women aged from 40 to 59 (26 in the experimental group and 26 in the control group) from G city participated in the study. Data were collected from February 13 to April 3, 2013. The experimental group received 8 sessions, scheduled once a week, with each session lasting two and a half hours. Outcome variables included stress, stress coping style, depression, anger, sleep and a physiological measure (EEG). Results: There were significant decreases for stress (t=-2.14, p=.037), depression (t=-2.64, p=.011), state trait anger (t=-3.79, p<.001) in the experimental group compared to the control group. Conclusion: The findings in this study indicate that the K-MBSR program is an effective program to decrease stress, depression, and state trait anger in middle aged women.

A study on the development of oxygen measurement device for diagnosis of peripheral vascular disease in lower extremity (하지 (下脂) 조직내의 말초 혈관계 질환 진단을 위한 산소 측정장치의 개발에 관한 연구)

  • 임현수;이준규;박동철
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 1999
  • The oxygen saturation of blood can be measured by the difference absorption in optical spectra of Hb and Hb0$_2$, as the well known previous study. In this study we developed the non-invasive oxygen measurement device for diagnosis of peripheral vascular disease in lower extremity using infrared and red LED which produce a peak spectral emission at a wavelength of 660 nm, and 940 nm. To evaluate the clinical application of the oxygen measurement device, we performed lower extremity study to measure the oxygen changes in response to physiological changes within biological tissue. The results showed that oxygen saturation of blood in biological tissue can be monitored from the separation arrangement light source and detector.

  • PDF

Comparison of Non-destructive Measuring Methods of Tomato Plant to Detect N, P and Ca Deficient Stresses (토마토 잎의 비파괴 계측에 의한 N, P, Ca 결핍 장해 진단법 비교)

  • 서상룡;류육성;정갑채;성제훈;이성희
    • Journal of Biosystems Engineering
    • /
    • v.25 no.6
    • /
    • pp.517-526
    • /
    • 2000
  • A series of experiments was conducted to evaluate the capability of detecting nutrimental deficient stress of N, P and Ca of a tomato plant using several fast and intact type physiological properties measuring devices - a chlorophyll content meter an infra-red thermometer to measure leaf temperature a chlorophyll fluorescence meter a porometer an optical spectrometer a multi-scan radiometer and a canopy analyzer. to detect N deficient stress a chlorophyll content meter a spectrometer and a multi-scan radiometer were useful and their possibility to detect was estimated as about 50%, 100% and 100% respectively. To detect P deficient stress the infra-red thermometer the porometer and the spectrometer proved their usefulness an their possibility to detect was estimated as about 70%, 70% and 70% respectively. To detect Ca deficient stress an thermometer a porometer a spectrometer and a multi-scan radiometer were useful and their possibility to detect was estimated as about 60%, 70%,80% and 100% respectively. The experiments resulted that use of a spectrometer and a multi-scan radiometer in combination with a chlorophyll content meter an infra-red thermometer and a porometer were desirable to distinguish the nutrimental stress tested in the study.

  • PDF

A Study on the Driver's Drowsiness Protection System (운전자 졸음방지 시스템 개발에 관한 연구)

  • Kim, B.J.;Park, S.S.;Oh, S.G.;Kim, I.Y.;Kim, N.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.48-51
    • /
    • 1997
  • The purpose of this paper is to propose a method to protect the drowsiness of a driver. We measured the physiological signals, response time, and ace expression of the subjects in normal and drowsy state. Those data are used to establish the drowsiness index and fuzzy system. We employed the computer vision technology to extract and eye, track eyelids and measure the parameters related to drowsiness. These parameters were ed into the fuzzy system to decide the drowsiness level, When the drowsiness was detected, the fuzzy system generated warning signals which cons ist of sound and fragrance. Our system was available in decision of the drowsiness level and improvement of subjects' state.

  • PDF

The Modeling of the Differential Measurement of Air Pressure for Non-intrusive Sleep Monitoring Sensor System

  • Chee, Young-Joon;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.373-381
    • /
    • 2005
  • The respiratory and heart beat signals are the fundamental physiological signals for sleep monitoring in the home. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body which makes long term measurement difficult and troublesome. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The concept of the balancing tube between two air cells is suggested to increase the robustness against postural changes during the measurement period. With this balancing tube, the meaningful frequency range could be selected by the pneumatic filter method. The mathematical model for the air mattress and balancing tube was suggested and the validation experiments were performed for step and sinusoidal input. The results show that the balancing tube can eliminate the low frequency component between two cells effectively. This technique was applied to measure the respiration and heart beat on the bed, which shows the potential applications for sleep monitoring device in home. With the analysis of the waveform, respiration intervals and heart beat intervals were calculated and compared with the signal from conventional methods. The results show that the measurement from air mattress with balancing tube can be used for monitoring respiration and heart beat in various situations.

Three Case Report of Bangpungtongsung-san Effect on Improvement of Hypertension Patients (방풍통성산(防風通聖散)으로 호전된 고혈압 환자 3례 보고)

  • Kim, Hee-Jun;Yoon, Keong-Min;Im, Eun-Young;Byun, Joon-Seok;Kim, Dae-Jun;Kwak, Min-A
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.740-743
    • /
    • 2009
  • Hypertension is one of the modifiable risk factors for stroke and heart disease. Lowering blood pressure is a primary or secondary preventative measure for stroke and heart disease. There are many antihypertension drugs. But these day there comes some side effect of antihypertension drugs. Headache, sexual dysfunction, inertia, dizziness, depression, and so on. So we use Bangpungtongsung -san to stage 1 hypertensive patients. After treatment with Bangpungtongsung-san, patients showed antihypertensive effect and improvement in general condition. The result of this study suggest that Bangpungtongsung-san might be usefully applied for the treatment of hypertension.

Analysis of Thermography on Skin Temperature during Exercise (운동시 피부온의 변화에 대한 서모그래피 활용 분석)

  • Kim, Hee-Eun;Lee, Ah-Ram
    • Fashion & Textile Research Journal
    • /
    • v.14 no.1
    • /
    • pp.130-135
    • /
    • 2012
  • The purpose of this study was to investigate the variation of regional skin temperature with thermography during exercise. Seven men completed 82-min trials which consisted of rest, exercise of $VO_2$ max 60% and recovery period at $30{\pm}0.5^{\circ}C$ and $60{\pm}5%RH$. Changes in skin temperature due to physical activity varied, depending region of the body. The skin temperature of the chest was significantly lowered and that of the back was significantly increased after exercise period(p < 0.05). There were significant negative relationship between the skin temperature of the chest and thermal comfort sensation, and positive relationship between skin temperature of the back and thermal comfort sensation(p < 0.05). It would be better to keep the chest warm, and the back cool during exercise. The skin temperature changed differently on body site due to exercise, and it was influenced by blood flow, sweating and air movement. This study would be meaningful in that the change of regional skin temperature during exercise was investigated consecutively with thermography. In further study, it would be more realistic to measure physiological response with functional sportswear which applies different functional fabric based on skin temperature.