• 제목/요약/키워드: physics image

검색결과 749건 처리시간 0.024초

A Novel RFID Dynamic Testing Method Based on Optical Measurement

  • Zhenlu Liu;Xiaolei Yu;Lin Li;Weichun Zhang;Xiao Zhuang;Zhimin Zhao
    • Current Optics and Photonics
    • /
    • 제8권2호
    • /
    • pp.127-137
    • /
    • 2024
  • The distribution of tags is an important factor that affects the performance of radio-frequency identification (RFID). To study RFID performance, it is necessary to obtain RFID tags' coordinates. However, the positioning method of RFID technology has large errors, and is easily affected by the environment. Therefore, a new method using optical measurement is proposed to achieve RFID performance analysis. First, due to the possibility of blurring during image acquisition, the paper derives a new image prior to removing blurring. A nonlocal means-based method for image deconvolution is proposed. Experimental results show that the PSNR and SSIM indicators of our algorithm are better than those of a learning deep convolutional neural network and fast total variation. Second, an RFID dynamic testing system based on photoelectric sensing technology is designed. The reading distance of RFID and the three-dimensional coordinates of the tags are obtained. Finally, deep learning is used to model the RFID reading distance and tag distribution. The error is 3.02%, which is better than other algorithms such as a particle-swarm optimization back-propagation neural network, an extreme learning machine, and a deep neural network. The paper proposes the use of optical methods to measure and collect RFID data, and to analyze and predict RFID performance. This provides a new method for testing RFID performance.

Fiber Optic Engine for Full Color Mobile Display

  • Arabi, H.;An, S.;Oh, K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.400-401
    • /
    • 2009
  • In this paper we report a micro projector including of RGB sources, a $3{\times}1$ Fiber Optic Color Synthesizer (FOCS), and a two dimensional micro mechanical scanning mirror. We further report a modifier micro collimator which can enhance the resolution of the screened image.

  • PDF

데이터 처리를 통한 테라헤르츠 (THz) 파의 2차원 이미지 개선 (Improvement of Two-Dimensional Terahertz Image by Digital Image Processing)

  • 손채화;진윤식;전석기;김근주;정순신;정원용
    • 한국광학회지
    • /
    • 제16권6호
    • /
    • pp.500-507
    • /
    • 2005
  • 테라헤르츠(terahertz: THz) 파를 이용한 2차원(2D) 투과 이미지의 개선 특성에 대해서 보고한다. THz 파 투과 신호의 진폭과 위상을 이용하여 다양한 시료에 대한 2차원 이미지를 얻었다. THz 파의 진폭과 위상 정보를 조합하는 새로운 방법을 제안하였고, 이 방법을 이용하여 피크 값의 크기 혹은 위상 중 어느 한가지만을 이용한 이미지보다 나은 이미지를 얻을 수 있었다. 또한 호모몰픽 필터링(homomorphic filtering) 디지틸 이미지 처리(digital image processing) 가 노이즈를 저감시키는데 효율적이고 나은 품질의 이미지도 얻을 수 있음을 보인다. 이 결과를 이용하여 향후 실시간 이미징에 응용 가능하다.

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

  • Park, Sang-Joon;Kim, Hyoung Joo;Noh, Jaewoo
    • Journal of the Optical Society of Korea
    • /
    • 제16권3호
    • /
    • pp.277-281
    • /
    • 2012
  • We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.

A Perceived Contrast Compensation Method Adaptive to Surround Luminance Variation for Mobile Phones

  • Yang, Cheng;Zhang, Jianqi;Zhao, Xiaoming
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.809-817
    • /
    • 2014
  • The loss in contrast-discrimination ability of the human visual system under high ambient illumination level can cause image quality degradation in mobile phones. In this paper, we propose a perceived contrast compensation method by processing the original displayed image. With consideration that the perceived contrast significantly varies across the image, this method extracts the local band contrast from the original image; it then compensates these contrast components to counteract the perceived contrast degradation. Experimental results demonstrate that this method can maintain most contrast details even in high ambient illumination levels.

소아 어린이에 대한 SPM 분석에서 성인 template image에 정규화된 영상의 유용성 평가

  • 신동호;박성옥;권수일;조철우;이명훈;윤석남;오은영
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.68-68
    • /
    • 2003
  • SPM(Statistical Parametric Mapping)은 개인의 서로 다른 조건에서의 뇌영상이나 환자그룹간의 functional image data를 비교분석 하는데 강력한 기능을 가지고 있다.

  • PDF

IMSNG: Automatic Data Reduction Pipeline gppy for heterogeneous telescopes

  • Paek, Gregory S.H.;Im, Myungshin;Chang, Seo-won;Choi, Changsu;Lim, Gu;Kim, Sophia;Jung, Mankeun;Hwang, Sungyong;Kim, Joonho;Sung, Hyun-il
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.53.4-54
    • /
    • 2021
  • Although the era of very large telescopes has come, small telescopes still have advantages for fast follow-up and long-term monitoring observation. Intensive monitoring survey of nearby galaxies (IMSNG) aims to understand the nature of the supernovae (SNe) by catching the early light curve from them with the network of small telescopes from 0.4-m to 1.0-m all around the world. To achieve the scientific goals with heterogeneous facilities, three factors are important. First, automatic processes as soon as data is uploaded will increase efficiency and shorten the time. Second, searching for transients is necessary to deal with newly emerged transients for fast follow-up observation. Finally, the Integrated process for different telescopes gives a homogeneous output, which will eventually make connections with the database easy. Here, we introduce the integrated pipeline, 'gppy' based on Python, for more than 10 facilities having various configurations and its performance. Processes consist of image pre-process, photometry, image align, image combine, photometry, and transient search. In the connected database, homogeneous output is summarized and analyzed additionally to filter transient candidates with light curves. This talk will suggest the future work to improve the performance and usability on the other projects, gravitational wave electromagnetic wave counterpart in Korea Observatory (GECKO), and small telescope network of Korea (SOMANGNET).

  • PDF

Preconditions for High Speed Confocal Image Acquisition with DMD Scanning.

  • Shim, S.B.;Lee, K.J.;Lee, J.H.;Hwang, Y.H.;Han, S.O.;Pak, J.H.;Choi, S.E.;Milster, Tom D.;Kim, J.S.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2006년도 하계학술발표회 논문집
    • /
    • pp.39-40
    • /
    • 2006
  • Digital image-projection and several modifications are the classical applications of Digital Micromirror Devices (DMD), however further applications in the field of optical metrology are also available. Operated with certain patterns, a DMD can function, for instance, as an array of pinholes that may substitute the Galvanic mirror or the stage scanning system presently used for 2 dimensional scanning in confocal microscopes. The various process parameters that influence the result of measurement (e.g. pinhole size, lateral scanning pitch and the number of pinholes used simultaneously, etc.) should be configured precisely for individual measurements by appropriately operating the DMD. This paper presents suitable conditions for the diffraction limited analysis between DMD-optics-CCD to achieve the best performance. Also sampling theorem that is necessary for the image acquisition by scanning system is simulated with OPTISCAN which is the simulator based on the diffraction theory.

  • PDF

Elemental image compatibility between parallax generation and Integral Imaging system for three-dimensional display

  • Ser, Jang-Il;Kang, Keun-Ho;Seo, Kwang-Bum;Cha, Sung-Do;Shin, Seung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1569-1574
    • /
    • 2006
  • We have studied elemental image compatibility between integral imaging(II) and parallax generation(PG) system for three-dimensional display. The elemental images of PG can be obtained by recombination of the elemental images picked up in II system. The theoretical verification and the experimental results show that the elemental images of PG are in correspondence with the elemental images of II system with proper transformation conditions.

  • PDF