• Title/Summary/Keyword: physical optics method

Search Result 99, Processing Time 0.024 seconds

Optimal Shape Design of Dual Reflector Antenna Based on Genetic Algorithm (유전 알고리즘 기반의 이중 반사경 안테나 형상최적화 기법)

  • Park, Jung-Geun;Chung, Young-Seek;Kang, Won-June;Shin, Jin-Woo;So, Joon-Ho;Cheon, Chang-Yul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.445-454
    • /
    • 2015
  • In this paper, we propose an optimal design method for a dual reflector antenna(DRA) using the Genetic algorithm. In order to reduce the computational burden during the optimal design, we exploit the iterative physical optics(IPO) to calculate the surface current distribution at each reflector antenna. To improve the accuracy, we consider the shadow effect by the structure and the coupling effect by the multi-reflection based on the iterative MFIE(Magnetic Field Integral Equation). To reduce the number of design variables and generate a smooth surface, we use the Bezier function with the control points, which become the design variables in this paper. We adopt the HPBW(Half Power Beam Width), the FNBW(First Null Beam Width), and the SLL(Side Lobe Level) as the objective or cost functions. To verify the results, we compare them with the those of the commercial tool.

A Comparative Study on Test Methods for Ophthalmic Lens Coatings (안경렌즈 코팅의 평가 방법에 관한 비교 연구)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Ha, Jin-Wook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • We have surveyed test methods for ophthalmic lens coatings and compared the coating quality of lenses supplied by manufactures. Plastic ophthalmic lenses are produced in increasingly larger volumes. However, their softness have need resistant coatings absolutely essential in most cases. Coating lenses are typically evaluated in physical and chemical properties through random selection from produced lenses. No international standard test methods for ophthalmic lenses exist for issues such as adhesion, abrasion resistance, hardness, chemical and hot water resistance with exception of transmittance. We have learned that there is a great deal of confusion regarding the methods employed in the various tests for ophthalmic coating lenses. For this reason, test methods for ophthalmic lens coatings are needed making all of international or domestic standards available.

  • PDF

Preparation and Physical Properties of Hydrogle Lens Containing N,N-Dimethylacrylamide (N,N-Dimethylacrylamide를 포함한 하이드로젤 렌즈의 제조 및 물리적 특성)

  • Kim, Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.6
    • /
    • pp.761-765
    • /
    • 2010
  • Poly (N,N-dimethylacrylamide) is very useful in various fields due to its remarkable properties, such as water solubility and biocompatibility. This study used N,N-dimethylacrylamide with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), NVP (N-vinyl-2-pyrrolidone) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical properties of the copolymerized polymer showed that the water content was 36 - 42%, refractive index was 1.433 - 1.426 and visible ray transmittance 90 - 91% while the oxygen permeability showed a distribution between 13.1 and $21.29{\times}10^{-11}(cm^2/sec)$ ($mlO_2/mL{\times}mmHg$). The measurement showed that the increased amount of oxygen permeability of the copolymer measured using the polarographic method range between 11.0% and 80.5%. Based on the results of this study, the produced copolymer is suitable for use as a material to high oxygen permeability hydrogel lenses.

Polymerization and Characterization of Ophthalmic Polymer Containing Glycerol dimethacrylate with High Wettability (Glycerol dimethacrylate를 포함한 고습윤성 안의료용 고분자의 중합 및 특성)

  • Cho, Seon-Ahr;Kim, Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.283-289
    • /
    • 2011
  • This study used glycerol dimethacrylate with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), MA (methacrylic acid) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical properties of the copolymerized polymer showed that the water content was 22~32%, refractive index was 1.442~1.463 and visible ray transmittance 90.0~90.5% while the contact angle showed a distribution between 56 and $65^{\circ}$. Also, the measurement showed that the decreased amount of contact angle of the copolymer measured using the sessile drop method ranged between $9.89^{\circ}$ and $18.99^{\circ}$ with increase of glycerol dimethacrylate. Based on the results of this study, the produced copolymer is suitable for use as a material to high wettability ophthalmic lenses.

Target Strength Prediction of Scaled Model by the Kirchhoff Approximation Method (Kirchhoff 근사 방법을 이용한 축소모델의 표적강도 예측)

  • 김영현;주원호;김재수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.442-445
    • /
    • 2004
  • The acoustic target strength (TS) of submarine is associated with its active detection, positioning and classification. That is, the survivability of submarine depends on its target strength. So it should be managed with all possible means. An anechoic coating to existing submarine or changing of curvature can be considered as major measures to reduce the TS of submarine. It is mainly based on the prediction of its TS. Under this circumstances, a study on the more accurate numerical methods becomes big topic for submarine design. In this paper, Kirchhoff approximation method was adopted as a numerical tool for the physical optics region. Secondly, the scaled models of submarine were built and tested in order to verify its performance. Through the comparison, it was found out that the Kirchhoff approximation method could be good design tool for the prediction of TS of submarine.

  • PDF

Recent Developments in Magnetic Measurements: from Technical Method to Physical Knowledge

  • Basso, V.;Fiorillo, F.;Beatrice, C.;Caprile, A.;Kuepferling, M.;Magni, A.;Sasso, C.P.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.331-338
    • /
    • 2013
  • We present a few significant advances in methods and concepts of magnetic measurements, aimed both at providing novel routes in the characterization of hard and soft magnetic materials and at improving our basic knowledge of the magnetization process. We discuss, in particular, investigation methods and experimental arrangements that have been developed in recent times for: 1) Hysteresis loop determination in extra-hard magnets by means of Pulsed Field Magnetometry; 2) Broadband observation of domain wall dynamics by highspeed stroboscopical Kerr techniques; 3) Entropy measurements in magnetocaloric materials by calorimetry in magnetic field. While pertaining to somewhat independent fields of investigation, all these measuring techniques have in common a solid approach to the underlying physical phenomenology and have a potential for further developments.

Mid-infrared Continuous-wave Optical Parametric Oscillator with a Fan-out Grating MgO:PPLN Operating Up to 5.3 ㎛

  • Bae, In-Ho;Yoo, Jae-Keun;Lim, Sun Do;Kim, Seung Kwan;Lee, Dong-Hoon
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.577-582
    • /
    • 2019
  • We report on a continuous-wave (cw) optical parametric oscillator (OPO) optimized for mid-infrared emission above 5.0 ㎛. The OPO is based on a magnesium-oxide-doped periodically poled LiNbO3(MgO:PPLN) crystal with a fan-out grating design. A linear two-mirror cavity resonating both at the pump and signal wavelengths is stabilized to the pump laser by using the modified Pound-Drever-Hall (PDH) method. The idler wavelength is continuously tunable from 4.7 ㎛ up to 5.3 ㎛ by varying the poling period of the fan-out grating crystal. Pumped by a diode-pumped solid state (DPSS) laser with a power of 1.1 W at 1064 nm, the maximum idler output power is measured to be 5.3 mW at 4.8 ㎛. The output power above 5.0 ㎛ is reduced to the hundreds of ㎼ level due to increased absorption in the crystal, but is stable and strong enough to be measured with a conventional detector.

Opto-Physical Properties of Ophthalmic Lens Polymer Containing σ, m, p-Substituted Difluoroaniline as Additives (σ, m, p-위치로 치환된 Difluoroaniline을 첨가제로 사용한 안의료용 렌즈 고분자의 물리·광학적 특성)

  • No, Jung-Won;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.69-77
    • /
    • 2014
  • Purpose: The functional ophthalmic lenses containing fluorine-substituted aniline group (2,4-difluoroaniline, 2,6-difluoroaniline, 3,4-difluoroaniline) were manufactured and the physical and optical characteristics of copolymerized ophthalmic lens were investigated. Methods: HEMA (2-hydroxyethylmethacrylate), NVP (N-vinyl pyrrolidone), MA (methacrylic acid), the cross-linker EGDMA (ethylene glycol dimethacrylate) and the initiator AIBN (azobisisobutyronitrile) were used as a basic combination and fluorine-substituted aniline group (2,4-difluoroaniline, 2,6-difluoroaniline, 3,4-difluoroaniline) were used as additives for preparing the hydrogel soft contact lenses. The hydrogel ophthalmic lens was manufactured by cast mould method and the ophthalmic lenses were stored in a 0.9% NaCl normal saline for 24 hrs. Results: The optical transmittance of the sample with addition 2,4-difluoroaniline showed that the UV-B(9.8~51.4%), UV-A(58.8~79.2%) and visible transmittance(87.0~90.4%). In the case of 2,6-difluoroaniline were measured the UV-B(80.2~83.2%), UV-A(85.8~86.4%), and visible transmittance(90.8~91.4%). Also, the optical transmittance of ophthalmic lens containing 3,4-difluoroaniline were measured the UV-B transmittance of 3.8~30.4%, UV-A transmittance of 47.8%~74.4% and the visible transmittance of 86.2~91.0% respectively. Conclusions: Based on the results of this study, 2,4-difluoroaniline and 3,4-difluoroaniline can be used effectively as additive for UV-blocking ophthalmic contact lenses.

Defect Inspection and Physical-parameter Measurement for Silicon Carbide Large-aperture Optical Satellite Telescope Mirrors Made by the Liquid-silicon Infiltration Method (액상 실리콘 침투법으로 제작된 대구경 위성 망원경용 SiC 반사경의 결함 검사와 물성 계수 측정)

  • Bae, Jong In;Kim, Jeong Won;Lee, Haeng Bok;Kim, Myung-Whun
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.5
    • /
    • pp.218-229
    • /
    • 2022
  • We have investigated reliable inspection methods for finding the defects generated during the manufacturing process of lightweight, large-aperture satellite telescope mirrors using silicon carbide, and we have measured the basic physical properties of the mirrors. We applied the advanced ceramic material (ACM) method, a combined method using liquid-silicon penetration sintering and chemical vapor deposition for the carbon molded body, to manufacture four SiC mirrors of different sizes and shapes. We have provided the defect standards for the reflectors systematically by classifying the defects according to the size and shape of the mirrors, and have suggested effective nondestructive methods for mirror surface inspection and internal defect detection. In addition, we have analyzed the measurements of 14 physical parameters (including density, modulus of elasticity, specific heat, and heat-transfer coefficient) that are required to design the mirrors and to predict the mechanical and thermal stability of the final products. In particular, we have studied the detailed measurement methods and results for the elastic modulus, thermal expansion coefficient, and flexural strength to improve the reliability of mechanical property tests.

Determining the Thickness of a Trilayer Thin-Film Structure by Fourier-Transform Analysis (푸리에 변환을 이용한 3층 구조 박막의 두께 측정)

  • Cho, Hyun-Ju;Won, Jun-Yeon;Jeong, Young-Gyu;Woo, Bong-Ju;Yoon, Jun-Ho;Hwangbo, Chang-Kwon
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.4
    • /
    • pp.143-150
    • /
    • 2016
  • The thickness of each layer in a multilayered system is determined by a Fourier-transform method using spectroscopic reflectance measurements. To verify this method, we first generate theoretical reflectance spectra for three layers, and these are fast-Fourier-transformed using our own Matlab program. Each peak of the Fourier-transformed delta function denotes the optical thickness of each layer, and these are transformed to physical thicknesses. The relative thickness error of the theoretical model is less than 1.0% while a layer's optical thickness is greater than 730 nm. A PI-(thin $SiO_2$)-PImultilayeredstructure produced by the bar-coating method was analyzed, and the thickness errors compared to SEM measurements. Even though this Fourier-transform method requires knowing the film order and the refractive index of each layer prior to analysis, it is a fast and nondestructive method for the analysis of multilayered structures.