• 제목/요약/키워드: photovoltaic power generator

검색결과 108건 처리시간 0.031초

태양광/풍력 복합발전의 보조 전력발생장치 개발에 대한 연구 (A Study on the Sub Power Generator for Photovoltaic/Wind Hybrid System)

  • 박세준;윤필현;임중열;이정일;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.247-251
    • /
    • 2003
  • The developments of the hybrid energy are necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed. However, even photovoltaic system cannot always generate stable output with ever-changing weather condition. In this paper, sub power generator for hybrid system(photovoltaic 500[W], wind power generation 400[W]) was suggested. Sub power Generator that uses elastic energy of spiral spring to photovoltaic system was also added for the present system. In an experiment, when output of photovoltaic system gets lower than 24[V] (charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates In DC generator. Also, control algorithm of sub power generator is used genetic algorithm(GA).

  • PDF

도시형 태양광/풍력 복합발전의 보조 전력발생장치 개발에 대한 연구 (A Study on the Auxiliary Power Generator for Urban Photovoltaic/Wind Hybrid System)

  • 박세준;윤정필;윤필현;지운석;임중열;차인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.187-191
    • /
    • 2004
  • Photovoltaic and wind power generation have an advantage of unpolluted and unlimited amount of energy resource. Since there is such an advantage in these energies, But photovoltaic system and wind system cannot always generate stable output with ever-changing weather condition. In this paper, the auxiliary power generator for hybrid system(photovoltaic 500[W], wind power generation 400[W]) was suggested. the auxiliary power generator that uses elastic energy of spiral spring to photovoltaic system was also added for present system. when output of photovoltaic system gets lower than 24[V], power was continuously supplied to load through the inverter by charging energy of spiral spring operates in DC generator.

  • PDF

계통연계 태양광발전시스템과 회전계자형 동기발전기의 병렬운전 특성 (Parallel Operation Characteristics of Utility Interactive Photovoltaic System and Revolving Field Type Synchronous Generator)

  • 류연수;유왕진;이철규;문종범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.43-48
    • /
    • 2008
  • Through simulations and field experiment on A.C. parallel operation of both Utility Interactive Photovoltaic System and Diesel Engine Revolving Field Type Synchronous Generator, following factors have been found. First, the inverter should be operated in three modes of frequency(mode.1: ${\pm}$0.3Hz, mode.2: ${\pm}$1Hz, mode.3: ${\pm}$2Hz) as default, considering properties of operating Synchronous Generator. Second, as a result of supplying 13.5kW of residual power, it has been found that Synchronous Generator takes the power input only as reactive power, because it was electrically stable with frequency of 60.14Hz and high voltage of 222.3V even when power factor was -0.94. Besides, it was mechanically stable, too, because the quake, noise, and temperature of Synchronous Generator in this case were 7.5mm/s, 97dB, and $6^{\circ}C$ respectively, which were lower than normal load connection of 145.6kW; 11.03mm/s. Thus, load share of Revolving Field Type Synchronous Generator reduces according to the supply of Photovoltaic System to the load power. In this experiment, 200kW of Synchronous Generator and 40kW of Photovoltaic System were operated in parallel. The load share was 20% in maximum. and 11.1lit/hr of fuel was saved.

  • PDF

Design of the power generator system for photovoltaic modules

  • Park, Sung-Joon
    • 전기전자학회논문지
    • /
    • 제12권4호
    • /
    • pp.239-245
    • /
    • 2008
  • In this paper, a dc-dc power converter scheme with the FPGA based technology is proposed to apply for solar power system which has many features such as the good waveform, high efficiency, low switching losses, and low acoustic noises. The circuit configuration is designed by the conventional control type converter circuit using the isolated dc power supply. This new scheme can be more widely used for industrial power conversion system and many other purposes. Also, I proposed an efficient photovoltaic power interface circuit incorporated with a FPGA based DC-DC converter and a sine-pwm control method full-bridge inverter. The FPGA based DC-DC converter operates at high switching frequency to make the output current a sine wave, whereas the full-bridge inverter operates at low switching frequency which is determined by the ac frequency. As a result, we can get a 1.72% low THD in present state using linear control method. Moreover, we can use stepping control method, we can obtain the switching losses by Sp measured as 0.53W. This paper presents the design of a single-phase photovoltaic inverter model and the simulation of its performance.

  • PDF

도시보급용 소형 태양광/풍력 복합발전의 계통연계운전에 관한 연구 (A Study on Utility Inter-Active for Urban Photovoltaic/Wind Hybrid Generation System)

  • 지운석;윤필현;조경재;이정일;임중열;차인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1504-1506
    • /
    • 2004
  • Photovoltaic and wind power generation have an advantage of unpolluted and unlimited amount of energy resource. Since there is such an advantage in these energies, But photovoltaic system and wind system cannot always generate stable output with ever-changing weather condition. In this paper, the auxiliary power generator for hybrid system(photovoltaic 500[W], wind power generation 400[W]) was suggested. the auxiliary power generator that uses elastic energy of spiral spring to photovoltaic system was also added for present system. when output of photovoltaic system gets lower than 24[V], power was continuously supplied to load through the inverter by charging energy of spiral spring operates in DC generator.

  • PDF

독립형 태양광, 풍력, 소형발전기 복합시스템에서 안정적인 전력공급을 위한 컨트롤러에 관한 연구 (The Study on the Controller for Supplying Stably Power with a Stand-Alone Photovoltaic/Wind/Small Generator Hybrid Power Generation System)

  • 최병수;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.48-56
    • /
    • 2012
  • The object of this paper is the controller for supplying stably power in a separate house in which a hybrid electrical storage system with a stand-alone photovoltaic/wind power generation system and a small generator is applied. In the photovoltaic/wind hybrid power system used in the separate house, when only the battery is used in sunless days, the capacity of the battery is become larger. In particular, as in recent days, if cloudy days are frequent due to anomaly climate, it is difficult to estimate the number of sunless days. Accordingly, it is preferable to build the electrical storage system that numbers of sunshineless days are to be controlled and a shortage amount of the power generation capacity is to be handled by a small generator system. In order to supply stably power of new renewable energy such as solar to any separate houses, it is preferable to reduce the capacity of battery by decreasing the number of sunless days when estimating the capacity of battery and to drive the small generator for compensation of the power shortage. Such system needs components including inverters for photovoltaic and wind power generation system, batteries and controllers for automatically driving the small generator, based upon the nature of the stand-alone house, and it is preferable to use the controller having a simpler and higher stability by adopting the all-in-one scheme to facilitate its maintenance.

HOMER를 이용한 가정용 태양광-연료전지 하이브리드시스템의 운전 최적화 (Optimization of Residential Photovoltaic-Fuel Cell Hybrid System Using HOMER(R))

  • 박세준;이영;최용성;이경섭
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.129-133
    • /
    • 2010
  • A hybrid system which is combined several complementary new and renewable power sources, such as photovoltaic, fuel-cell, and wind generator, etc., has been presented in various approaches. For instance, a photovoltaic cannot always generate stable output power with ever-changing weather condition, so it might be co-generated with a wind generator, diesel generator, and some other sources. In this paper, a residential PV-FC hybrid system is suggested as a distribution power source, and its operation is optimized by HOMER$^{(R)}$. As a result, it is the most economic that 5[kW] PV, 1[kW] FC, 4 batteries, 2[kW] electrolyzer, 0.5[kg] $H_2$ tank, 3[kW] converter are applied to the hybrid system.

태양광발전을 위한 새로운 3상한 시스템에 관한 연구 (A novel three-phase power system for a simple photovoltaic generator)

  • 박성준;김정훈;김진영;김종현;김희제
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.181-184
    • /
    • 2005
  • Operating conditions of photovoltaic power generator is very sensitive to the PV modules. The PV module's control is an importance issue in the removing DC ripple noise. In this paper, the phase-shifted-carrier technique, which is a new three-step dc-dc power multi-converter schemes, is applied to solar generator system to improve the output current waveform. The novel type of three-step dc-dc converter presented has many features such as the good output waveform, high efficiency, low switching losses, low acoustic noise. The circuit configuration is constructed by the conventional full-bridge type converter circuit using the isolated DC power supply for which the solar cell is very suitable. In the end, a circuit design for understanding three-step dc-dc converter and new solar power system were presented

  • PDF

오래된 모듈의 특성에 관한 연구 (A study on the Characteristics of the old modules)

  • 홍사근;최홍규;염성배;송영주;최영준
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.351-354
    • /
    • 2009
  • 화석연료의 고갈 및 환경문제로 재생에너지의 중요성이 더욱 부각되고 있다. 재생에너지중 가장 상용화된 태양광 발전은 태양광 발전소가 생길만큼 활성화 되었다. 국내 태양광 발전용 모듈의 수명은 약 20년으로 추정되나 국내 기후 및 환경에 20년 이상 될 경우 얼마만큼 효율이 감소되는지 검증되지 않았다. 본 논문에서는 23년된 모듈 3장을 통해 최대전력의 감소폭을 알아보았다.

  • PDF

단독주택 저압 주택용 전기 소비자가 태양광 발전기 대여시 경제성 분석 (An Economic Analysis of a Low-Voltage Residential Electricity Consumer at a Detached House When Renting a Photovoltaic Generator)

  • 김태현
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.687-694
    • /
    • 2019
  • 주택용 전기 소비자는 태양광 발전기를 대여할 수 있고, 만일 감소된 전기요금이 대여료보다 크다면 수익이 발생할 수 있다. 아직까지 수익의 정확한 함수식은 계산되지 않았는데 본 논문에서 계산했다. 두 가지 가정이 있다. 첫 번째는 대여한 태양광 발전기가 월간 300kWh 발전하는 것이고, 두 번째는 태양광 발전기를 대여할 때 일시불로 362300원 지불한다는 것이다. 함수가 구간에 따라 달라지므로 3개의 구간을 가정하고 각 구간에서의 함수를 유도했다. 유도한 함수에 의해서 기본 7년간 월간 전기 사용량 401~1000kWh 사용하는 저압 주택용 전기요금 소비자의 수익률, 회수 시간, 감도를 계산했다. 본 논문에서 계산된 값에 의해서 월간 전기 사용량 401~1000kWh 사용하는 저압 주택용 전기요금 소비자가 3kW 태양광 발전기를 대여할지 말지 결정할 때 중요한 자료다.