• 제목/요약/키워드: photovoltaic equipment

검색결과 130건 처리시간 0.026초

3상 계통연계형 태양광 PCS의 단독운전검출을 위한 개선된 무효전력변동기법 (Improved RPV(reactive-power-variation) anti-islanding method for grid-connected three-phase PVPCS)

  • 이기옥;정영석;소정훈;유병규;유권종;최주엽;최익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1159-1160
    • /
    • 2006
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, this has raised potential problems of network protection on electrical power system. One of the numerous problems is an Island phenomenon. There has been an argument that because the probability of islanding is extremely low it may be a non-issue in practice. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an island can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficient to cause a trip, plus the time required to execute the trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. And, third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an island. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. So the verification of anti-islanding performance is strongly needed. In this paper, the authors propose the improved RPV method through considering power quality and anti-islanding capacity of grid-connected three-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation and experimental results are verified.

  • PDF

몽골의 가정용 PV-ES 하이브리드 시스템 개발을 위한 연구 (The Study on Development of PV-ES hybrid system for Mongolian Household)

  • ;;박준형
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1905-1912
    • /
    • 2017
  • In recent years, Ulaanbaatar, a capital of Mongolia has witnessed major problem that air quality reaches hazardous level during the winter season. Coal combustion for heating of every house in "Ger" district is main reason. One way to reduce the air pollution is mass usage of electric heater. However, there are several difficulties such as overload and degradation of transformers and other equipment used in distribution and transmission systems as well as power shortage occurrence in evening peak period due to residential consumption. This study aims to contribute for solving the air pollution and power shortage problem in Mongolia. One possible solution could be distributed generation (DG) with photovoltaic (PV) penetration. In this study, PV with energy storage (ES) hybrid system to reduce peak load is analyzed. We proposed the suitable structure of PV-ES hybrid for Mongolian household, and suggested several operation scenarios. Optimal operation algorithm is carried out based on a comparison aspect from economical, grid impact and PV penetration possibility. The economic analyse shows annual income of 520USD, and has a payback period of 8 years for selected scenario. The proposed PV-ES system structure is verified by experimentation set on the building rooftop in city center. The suggested scenario is planned to apply for system in further research.

제로에너지건축물의 에너지 소요량과 생산량 비교를 통한 패시브와 액티브 요소의 투자 검토 연구 (A Study on the Investment Review of Passive and Active Elements through Comparison of Energy Demand and Generation Variation of Zero Energy Building)

  • 이순명;이태규;김정욱
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.13-22
    • /
    • 2018
  • At the time when zero energy building is expected to be generalized, this study examines whether the investment in the passive element or the active element is more effective in terms of energy in the construction process of zero energy building. In other words, the effect of energy demand by passive element and the change of energy generation by active element are examined in terms of the same investment cost. The purpose of this study is to examine the change of energy demand by passive element and the change of energy generation by active element in zero energy building and to make reasonable investment decision by comparing energy with cost aspect. For this purpose, we selected the buildings to be subjected to energy simulation and derive the required energy amount and energy generation amount by using meteorological data of four regions in Korea. The change of energy demand and energy generation according to the change of application condition was derived. In order to compare and analyze the changes in energy demand and generation at the same cost standard through price survey and quotation of window and photovoltaic power generation equipment.

영농형 태양광 시스템에서의 스마트 농업을 위한 의사결정지원시스템 (A Decision Support System for Smart Farming in Agrophotovoltaic Systems)

  • 김영진;소준용;온영재;이재윤;이재윤
    • 산업경영시스템학회지
    • /
    • 제45권4호
    • /
    • pp.180-186
    • /
    • 2022
  • Agrophotovoltaic (APV) system is an integrated system producing crops as well as solar energy. Because crop production underneath Photovoltaic (PV) modules requires delicate management of crops, smart farming equipment such as real-time remote monitoring sensors (e.g., soil moisture sensors) and micro-climate monitoring sensors (e.g., thermometers and irradiance sensors) is installed in the APV system. This study aims at introducing a decision support system (DSS) for smart farming in an APV system. The proposed DSS is devised to provide a mobile application service, satellite image processing, real-time data monitoring, and performance estimation. Particularly, the real-time monitoring data is used as an input of the DSS system for performance estimation of an APV system in terms of production yields of crops and monetary benefit so that a data-driven function is implemented in the proposed system. The proposed DSS is validated with field data collected from an actual APV system at the Jeollanamdo Agricultural Research and Extension Services in South Korea. As a result, farmers and engineers enable to efficiently produce solar energy without causing harmful impact on regular crop production underneath PV modules. In addition, the proposed system will contribute to enhancement of the smart farming technology in the field of agriculture.

반도체 메모리 소자 제조에서 High Aspect Ratio Contact 식각 연구 동향 (Research Trend of High Aspect Ratio Contact Etching used in Semiconductor Memory Device Manufacturing)

  • 탁현우;박명호;이준수;최찬혁;김봉선;장준기;김은구;김동우;염근영
    • 한국표면공학회지
    • /
    • 제57권3호
    • /
    • pp.165-178
    • /
    • 2024
  • In semiconductor memory device manufacturing, the capability for high aspect ratio contact (HARC) etching determines the density of memory device. Given that there is no standardized definition of "high" in high aspect ratio, it is crucial to continuously monitor recent technology trends to address technological gaps. Not only semiconductor memory manufacturing companies such as Samsung Electronics, SK Hynix, and Micron but also semiconductor manufacturing equipment companies such as Lam Research, Applied Materials, Tokyo Electron, and SEMES release annual reports on HARC etching technology. Although there is a gap in technological focus between semiconductor mass production environments and various research institutes, the results from these institutes significantly contribute by demonstrating fundamental mechanisms with empirical evidence, often in collaboration with industry researchers. This paper reviews recent studies on HARC etching and the study of dielectric etching in various technologies.

해머 타격과 관입량 측정이 자동화된 소형 동적콘관입시험기의 현장 적용성 연구 (A Study on the Field Application of a Small Dynamic Cone Penetration Tester Using Hammer Automatic Strike and Penetration Measurement)

  • 채휘영;권순달
    • 한국지반환경공학회 논문집
    • /
    • 제24권12호
    • /
    • pp.5-11
    • /
    • 2023
  • 도로나 태양광 발전시설의 인위적으로 조성된 지반이 집중호우와 같은 강우에 의해서 약화되면서 발생되는 산사태, 토석류 등에 의해 경제적 피해가 발생하고 있다. 인위적으로 조성된 지반의 안정성을 파악하기 위해서 지층의 구성상태, 역학적 특성등의 지반정보 확인이 매우 중요하다. 하지만 조사부지가 대부분 급경사로 이루어지거나 진입로가 대부분 없기 때문에 지반정보를 확인하기 위해 일반적으로 사용되고 있는 시추장비와 표준관입시험의 수행이 쉽지 않다. 본 연구에서는 소형화한 오거시추 장비와 자동낙하장치를 적용한 동적콘관입시험(Dinamic Cone Penetrometer, DCP) 장비를 개발하여 산지태양광 부지에서의 적용성을 확인하기 위하여 콘저항값 및 동적콘관입시험값과 표준관입시험값의 상관관계를 분석하였다. 그 결과 콘저항값은 qc = 0.46 N, 동적콘관입시험값(Nd)는 Nd = 1.58 N으로 기존연구자들의 결과와 유사한 값을 확인하여 그 신뢰성을 확보하였다.

온실설비 작동용 태양광발전시스템의 발전 성능 분석 (Power Generating Performance of Photovoltaic Power System for Greenhouse Equipment Operation)

  • 윤용철;배용한;유영선;이성현;서원명
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.177-184
    • /
    • 2009
  • 본 연구는 온실 운영에 필요한 전력량을 확보함으로서 온실경영비 절감을 목적으로 우선 태양광발전시스템을 온실의 인접한 건물의 옥상에 설치하여 기상상태에 따른 발전량을 실험적으로 검토하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 최고, 평균 및 최저온도는 각각 $0.4{\sim}34.1,\;-6.1{\sim}22.2$$-14.1{\sim}16.7^{\circ}C$ 정도의 범위에 있었다. 그리고 일사량의 경우, 최대, 평균 및 최저값은 각각 $28.8MJ{\cdot}m^{-2}$, $14.9MJ{\cdot}m^{-2}$$0.6MJ{\cdot}m^{-2}$ 정도였고, 전력은 일사량에 비례해서 증가하지 않고 약 750W 전후에서 거의 일정한 것을 알 수 있었다. 일일 최대, 평균 및 최소 소비전력량은 각각 약 5.2kWh, 2.5kWh및 0kWh정도였다. 본 실험에 사용된 시스템의 평균 소비전력량을 기준으로 보면, 온풍기의 용량 및 작동시간이 작은 경우는 충분하지만 큰 경우는 부족한 것으로 나타났다. 온풍기의 용량이 큰 경우, 어레이 면적이 현재의 약 3배인 약 $21m^2$ 정도이면 평균 전력량으로 충분할 것으로 판단되었다. 물론 어레이의 온도가 높아지는 한 여름철에는 일사량에 비례해서 발생 전력이 증가하지 않은 것으로 나타났지만, 현재까지 실험결과로 보면, 두 인자간에 상관계수가 0.84 정도로 상관관계가 높은 것으로 나타났다.

기계적 하중 하에서 복합재료 시험편에 접착된 단결정 실리콘태양전지의 성능평가 (Photovoltaic performance evaluation of the bonded single crystalline silicon solar cell on composite specimens under mechanical loading)

  • 김종천;최익현;김대현;정성균
    • Composites Research
    • /
    • 제24권6호
    • /
    • pp.56-63
    • /
    • 2011
  • 본 연구에서는 화석에너지 고갈과 환경문제로 인해 새로운 신재생에너지로 주목 받고 있는 태양전지를 대표적인 경량재료인 복합재료에 적용하기 위해 적절한 태양전지 접착 방법에 대한 연구를 진행하였다. 사용된 태양전지는 후면전극 태양전지로 에너지변환 실험실 효율이 약 24.2%인 태양전지를 사용하였다. 하지만, 실리콘계열 태양전지는 재료의 특성상 깨지기 쉽기 때문에 일반적으로 사용되고 있는 동시경화 접착법 대신 접착제를 이용한 이차 접착법을 사용하였다. 접착재료는 태양전지의 충진재 및 접착제로 사용되고 있는 EVA film 과 프리프레그의 수지인 Resin film, 그리고 탄성 접착제를 이용하여 실험을 진행 하였으며, 태양전지가 접착된 복합재료 시험편에 기계적 하중을 부가하여 접착제 종류별 태양전지의 성능변화를 측정하였다. 또한, 기계적 하중 하에서 실시간으로 태양전지의 성능을 평가할 수 있는 측정장치를 설계하여 접착재료별 파단 시점과 특성을 비교 평가 하였다. 파단면분석을 통해 태양전지 효율 감소원인을 분석하여 고찰하였다. 실험결과 태양전지의 접착방법에 따라서 태양전지의 효율이 크게 영향을 받는다는 것을 파악하였다. 또한, 탄성접착제를 사용한 접착 방법이 가장 높은 태양전지 효율 성능을 보여주고 있음을 확인하였다.

DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법 (Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop)

  • 이기옥;유병규;유권종;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

FRTU 시뮬레이터를 이용한 차세대 배전지능화시스템 네트워크 성능검증 (Network Performance Verification for Next-Generation Power Distribution Management System Using FRTU Simulator)

  • 여상욱;손성용
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.523-529
    • /
    • 2020
  • 배전선로계통의 효율적인 관리와 운영을 위해서 배전지능화시스템은 필수적이다. 배전지능화시스템은 IT를 기반으로 배전망을 통합관리하는 시스템으로 전력산업의 발전과 더불어 진화해 오고 있다. 현재의 배전지능화시스템은 주장치 단위의 독립운전을 기준으로 상대적으로 낮은 네트워크 전송속도로 운영되도록 설계되어있다. 하지만 최근 급속히 보급이 증가하고 있는 태양광이나 에너지 저장장치와 같은 분산자원으로 인하여 미래 배전환경의 운영은 보다 복잡해 지고 있으며 다양한 정보의 실시간 수집이 필요하다. 본 연구에서는 기존의 배전지능화의 한계를 극복하기 위해 차세대 배전지능화 시스템의 요구사항을 도출하였으며, 이를 기반으로 배전계통에 필요한 통신네트워크 체계와 성능요건을 정의하였다. 배전지능화시스템과 같은 대규모 시스템의 현장 도입에는 과도한 시간과 비용이 소요되므로 설계된 시스템의 성능 검증을 위하여 소프트웨어 기반의 단말장치 시뮬레이터를 개발하였다. 시뮬레이터를 활용하여 실제 운영과 유사한 시험환경을 구축하고, 단말장치를 1,000대 까지 증가시켰을 때 제시된 시스템의 네트워크 점유는 최대 10% 이하로 차세대 배전지능화시스템의 기능을 지원하기 위한 네트워크 요구사항을 충족함을 보였다.