• Title/Summary/Keyword: photovoltaic characteristics

Search Result 732, Processing Time 0.023 seconds

Analysis on Power Generation Characteristics of a Vehicle Rooftop Photovoltaic Module with Urban Driving Conditions (도심 주행 조건에 따른 차량 탑재 태양광모듈의 발전특성 분석)

  • Jeon, Seonwoo;Choung, Seunghoon;Bae, Sungwoo;Choi, Jaeyoung;Shin, Donghyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.79-86
    • /
    • 2020
  • This study examines the power generation characteristics of a vehicle rooftop photovoltaic module with urban driving conditions. Actual test data with an illuminometer and a thermometer were used to analyze the power generation characteristics of the vehicle rooftop photovoltaic module. In addition, the power generation characteristics were analyzed in terms of urban driving conditions, irradiance, ambient temperature, and photovoltaic module temperature. This study also analyzes the power generation characteristics of the vehicle rooftop photovoltaic module with urban driving conditions through a wavelet transform filtering method. The power generation characteristics of the vehicle rooftop photovoltaic module with urban driving conditions depend on the change in irradiance rather than that in photovoltaic module temperature.

Irradiation Dependance of I-V Characteristics of Photovoltaic System (태양광 시스템에서 전압-전류 특성의 일사량 의존성)

  • Park, Se-Joon;Hwang, Jun-Won;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.521-525
    • /
    • 2009
  • Solar, as an ideal renewable energy, has inexhaustible, clean and safe characteristics. However, solar energy is an extreme intermittent and inconstant energy source. In order to improve the photovoltaic system efficiency and utilize the solar energy more fully, and the DC current vary with the irradiation, it is necessary to study the characteristics of photovoltaic I-V according to the external factors. This paper presents the analysis of characteristics of photovoltaic I-V according to the irradiation. The results show that the DC current of the photovoltaic system are increased along with the increasing values of irradiation.

Analysis of Power Pattern According to Irradiation for Photovoltaic Generation System (태양광발전 시스템의 일사량에 따른 전력 패턴 분석)

  • Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.602-608
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation of photovoltaic cell and amount of power given by photovoltaic cell was quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. As I-V characteristics according to a temperature range of 10~50[$^{\circ}C$], the area of I-V characteristics were increased with an increase in temperature. Since this area corresponds to the power, output power is thought to have increased with temperature. As output power characteristics according to a temperature range of 10~50[$^{\circ}C$], output power was increased with an increase in temperature. Since output power increases with temperature increase, the result corresponds well to the related equation on temperature and output power. As I-V characteristics according to a irradiation range of 100~900 [$W/m^2$], voltage and current were increased with an increase in irradiation. The result is thought of as an increase in output power with increasing irradiation. As output power characteristics according to a irradiation range of 100~900 [$W/m^2$], output power was increased with increasing irradiation. This result corresponds well to the related equation on irradiation and output power.

A Study on Modeling of Tracking-Type Floating Photovoltaic System based on Matlab/Simulink (매틀랩/시뮬링크 기반 추적식 수상태양광 발전시스템의 모델링에 관한 연구)

  • Kim, In-Soo;Oh, Sung-Chan;Kim, Yang-Mo;Choi, Young-Kwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.805-811
    • /
    • 2015
  • Floating photovoltaic systems have been developed by the construction process such as design, construction, operation and management. Therefore, the power of floating photovoltaic systems has been calculated by using simple formulas and the optimal tracking interval is set by operation experience. But, flow characteristics have a decisive effect on it unlike land based PV systems. In this paper, a tracking floating photovoltaic system is modeled by using Matlab/simulink. The modeling for the floating photovoltaic system is verified through applying the flow characteristics based on actual operating data of 100㎾ class tracking floating photovoltaic.

Analysis of Electrical Characteristics of Amorphous Silicon Thin Film Photovoltaic Module Exposed Outdoor (옥외 설치된 비정질 실리콘 박막태양전지모듈의 전기적 출력 특성 분석)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.62-67
    • /
    • 2008
  • In this study, we analyze the electrical characteristics of amorphous silicon thin film photovoltaic module which are installed about 5 years ago. Four modules from PV system are extracted and measured the maximum power change ratio using solar simulator(Class A). Also, infrared camera is used to get thermal distribution characteristics of system. The external appearance change is compared with initial module by naked eye examination. Through this experiment, 31% maximum output power drop is observed. The detail description is specified as the following paper.

I-V Characteristics According to Temperature for Photovoltaic Systems (태양광 발전시스템의 온도에 따른 전압-전류 특성)

  • Hwang, Jun-Won;Lee, Ying;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.183-185
    • /
    • 2009
  • In this thesis, output voltage, current and power of solar module were classified by irradiation and module temperature from data of overall operating characteristics collected for one year in order to manage efficient photovoltaic generation system and deliver maximum power. In addition, from these data, correlations between irradiation, module temperature of photovoltaic cell and amount of power given by photovoltaic cell was quantitatively examined to deduce optimization of the design and construction of photovoltaic generation system. The results of this thesis can be summarized as follows. As I-Y characteristics according to a temperature range of 10$\sim$50[], the area of I-V characteristics were increased with an increase in temperature. Since this area corresponds to the power, output power is thought to have increased with temperature.

  • PDF

Analysis of Maximum Power Generation of Photovoltaic Module Depending on Constituent Materials and Incident Light Characteristics (구성 재료와 방사조도 특성에 따른 태양전지모듈의 최대출력 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • In this study, we analyze the maximum power generation of photovoltaic(PV) module depending on constituent materials and incidence angle dependence of light. To verify characteristics of constituent materials, we made photovoltaic modules with 4 kinds of solar cells and textured glass according to fabrication method. To find the degree of the maximum power generation dependence on intensity of light, Solar Simulator is applied by changing angle of module and light intensity. Through this experiment, to obtain maximum power generation from limited PV modules, it is needed to fully understand constituent materials, fabrication method and dependence of incident light characteristics.

Characteristics of Photovoltaic I-V and P-V According to the Irradiation and Module Temperature (태양광 시스템의 일사량과 모듈온도에 따른 I-V 및 P-V 특성에 관한 연구)

  • Shin, Hyeon-Man;Li, Ying;Choi, Yong-Sung;Zhang, You-Sai;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.339-346
    • /
    • 2009
  • Photovoltaic (PV) energy is a renewable and harmless energy which offers many advantages. However, solar energy is an extreme intermittent and inconstant energy source. In order to improve the photovoltaic system efficiency and utilize the solar energy more fully, and the DC current and DC power vary with the irradiation and module temperature, it is necessary to study the characteristics of photovoltaic I-V and P-V according to the external factors. This paper presents the analysis of characteristics of photovoltaic I-V and P-V according to the irradiation and the module temperature. The results show that the DC current and the DC power of the photovoltaic system are increased along with the increasing values of irradiation and module temperature.

Roof-attached Crystalline Silicon Photovoltaic Module's Thermal Characteristics (지붕 설치형 결정질 실리콘 태양전지모듈의 온도 특성)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Yoon, Soon-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.11-18
    • /
    • 2012
  • To expect accurately the maximum power of solar cell module under various installation conditions, it is required to know the performance characteristics like temperature dependence. Today, the PV (photovoltaic) market in Korea has been growing. Also BIPV (building integrated photovoltaic) systems are diversified and become popular. But thermal dependence of PV module is little known to customers and system installers. In IEC 61215,a regulation for testing the crystalline silicon solar cell module, the testing method is specified for modules. However there is limitation for testing the module with diverse application examples. In extreme installation method, there is no air flow between rear side of module and ambient, and it can induce temperature increase. In this paper, we studied the roof type installation of PV module on the surface of one-axis tracker system. We measured temperature on every component of PV module and compared to open-rack structure. As a result, we provide the foundation that explains temperature characteristics and NOCT (nominal operation cell temperature) difference. The detail description will be specified as the following paper.

A Study on the Characteristics of Photovoltaic I-V and P-V According to the Irradiation and Module Temperature (태양광 시스템의 일사량과 모듈온도에 따른 I-V 및 P-V 특성 연구)

  • Shin, Hyeon-Man;Li, Ying;Park, Se-Joon;Choi, Yong-Sung;Zhang, You-Sai;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.437-446
    • /
    • 2009
  • Solar, as an ideal renewable energy, it has inexhaustible, clean and safe characteristics. In order to improve the photovoltaic system efficiency and utilize the solar energy more fully, and the DC current and DC power vary with the irradiation and module temperature, it is necessary to study the characteristics of photovoltaic I-V and P-V according to the external factors. This paper presents the analysis of characteristics of photovoltaic I-V and P-V according to the irradiation and the module temperature. The results show that the DC current and the DC power of the photovoltaic system are increased along with the increasing values of irradiation.