• Title/Summary/Keyword: photoplethysmogram

Search Result 59, Processing Time 0.041 seconds

Detection of Radial Pulse Wave by Photoplethysmogram (광전용적맥파를 이용한 요골동맥 맥파 검출)

  • 정동근;김광년;연규선;최병철;서덕준
    • Journal of Life Science
    • /
    • v.13 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes radial pulse waves recorded by photoplethysmogram with 940 nm wavelength infra red light. Radial pulse waves were varied according to the recording site. When recorded on the skin over radial artery, the radial pulse wave was inverted, comparing to the photoplethysmogram at fingertip. The mechanism of inverted pulse wave seemed to be caused by the change of the blood volume in the subcutaneous tissue between radial artery and the skin, which was reduced during systolic period and increased during diastolic period of the cardiac cycle. These results suggest that radial arterial wall may reflect infra red ray.

Algorithm of the Detection of the Feature points using distributed feature points of the Second Derivative of Photoplethysmogram waveform (이차 미분 맥파의 변곡점 분포를 이용한 특징점 추출 알고리즘)

  • Kim, Pan-Ki;Ahn, Chang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1988_1989
    • /
    • 2009
  • 본 논문은 이차 미분 맥파(SDPTG, Second Derivation of Photoplethysmogram)를 측정하여 이차 미분 맥파의 5개의 특징점을 검출하는 방법에 대한 내용을 기술한다. 본 논문에서는 측정된 신호의 신호대 잡음비(SNR)을 높이는 방법과 기존의 미분을 이용한 변곡점 추출의 한계적인 부분, 그리고 본 논문에서 제안하는 이차 미분 맥파의 특징점의 분포를 이용한 특징점 추출 알고리즘에 대해서 설명한다.

  • PDF

Elevated Levels of Serum Lipids Accelerate Biological Vascular Aging evaluated by the Second Derivative of Photoplethysmogram Waveform in the Middle-Age Adults (중년 성인남녀의 혈중 지질농도가 가속도맥파에 미치는 영향)

  • Nam, Tong-Hyun;Koh, Hyung-Kyun;Park, Young-Bae
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.126-137
    • /
    • 2002
  • Objective : There is accumulating data that cardiovascular diseases, including hypertension, cerebro-vascular accident, coronary heart disease, relate to atherosclerotic changes. Increased serum levels of lipids could play a role in these circumstances. the SDPTG(the second derivative of photoplethysmogram waveform) is noninvasive methods for evaluating the pulse wave and is correlated with age and other risk factors for atherosclerosis. Methods : To study the effects of serum lipid levels on the SDPTG in the middle-age adults, data on serum lipid levels and the SDPTG were collected in 80 healthy middle age with varying serum lipid concentrations. Biological vascular age was assessed using the SDPTG. the SDPTG consists of an a, b, c, and d wave in systole and an e wave in diastole; an SDPTG aging index(Al) was calculated as (b-c-d-e)/a. Results : Serum triglyceride, total cholesterol, total lipid, phospholipid, HDL cholesterol levels were respectively and significantly correlated with SDPTG Al. Serum lipid levels and blood pressure are age-dependent and the SDPTG is blood pressure-dependent. Restricting analysis to age and blood pressure yield strong positive correlations between serum triglyceride, total lipid levels and SDPTG Al, but no correlations between serum total cholesterol, phospholipid levels and SDPTG Al. Conclusion : The results of this study suggest that preventive acupuncture programs or herbal medications for reducing serum lipid, especially triglyceride, levels in middle-age should include a evaluation of biological vascular aging with the second derivative of photoplethysmogram waveform.

  • PDF

Comparison of vascular compliance between normal and replanted fingers using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상과 재접합 손가락의 혈관 탄성도 비교)

  • Kim, Sung-Woo;Kim, Jin-Tae;Hong, Hyun-Ki;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.42-44
    • /
    • 2006
  • Up to the present, finger replantation patients have complained about various symptoms because of blood circulatory failure. Objective evaluation methods for the level of the blood circulatory failures in fingers were needed other than patient's subjective symptoms and complaints. Photoplethysmogram(PPG) measured from fingers is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, vascular compliance study for finger replantation patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and replanted finger vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. For 43 finger replantation patients, the average vascular compliance of replanted finger is lower than the normal finger statistically(p=0.001). we suggested an objective evaluation of finger vascular compliance for finger replantation patients and effect of surgical operation.

  • PDF

Comparison of peripheral vascular compliance between normal and diabetic group using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Kang, Eun-Seok;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.67-69
    • /
    • 2007
  • Recently, the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and diabetic group vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy is statistically lower than the normal group(p<0.05). We suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

  • PDF

Effects of Acupuncture at GV 20(Baihui) Evaluated by the Second Derivative of Photoplethysmogram Waveform under Stress (백회혈(百會穴) 자침(刺鍼)이 스트레스 상태에서의 가속도맥파에 미치는 영향)

  • Lee, Jin-Hwan;Kim, Jin-Yi;Kim, Soo-Jung;Seo, Joo-Hee;Sung, Woo-Yong
    • Journal of Oriental Neuropsychiatry
    • /
    • v.21 no.3
    • /
    • pp.19-27
    • /
    • 2010
  • Objectives : This study was designed to report the effect of acupuncture at GV 20(Baihui) evaluated by the second derivative of photoplethysmogram waveform(SDPTG) under stress. Methods : 15 healthy volunteers participated in this study. 1. After 5 minutes rest, mental stress was provided for 5 minutes. And then subjects rested for 15 minutes. SDPTG was recorded before and after mental stress and after 15 minutes restness. 2. After 5 minutes rest, mental stress was provided for 5 minutes. And acupuncture at GV 20 remained for 15 minutes. SDPTG was recorded before and after mental stress and after 15 minutes acupuncture. Results : 1. Mental Stress didn't make significant change at SDPTG. 2. In a comparison of pre-acupuncture and post-acupuncture at the GV 20, b/a ratio(P<0.05) and Sano aging index(P<0.05) was decreased significantly. Conclusions : We concluded that acupuncture at the GV 20 may be effective method to recover vascular function.

Comparison of left and right hand peripheral vascular compliance between normal and diabetic group using the second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자 간의 왼손과 오른손 말초혈관 탄성도 차이 비교)

  • Lee, Tak-Hyung;Shim, Young-Woo;No, Hyung-Wook;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.133-134
    • /
    • 2008
  • 우리나라의 당뇨병 유병률은 경제발전과 식생활의 급속한 서구화로 빠른 속도로 증가하고 있다. 특히 당뇨병은 유병기간이 길수록 여러 합병증을 초래하는데 그 중 하나가 혈관경화증이다. 혈관 경화증은 신체 부위별로 그 진행 속도가 다르다. 광혈류측정법(PPG, photoplethysmogram)은 간편한 혈류량 측정방법으로 PPG 2차 미분 방법을 이용해서 혈관의 경화도를 진단할 수 있다. 이러한 PPG 2차 미분방법을 이용하여 당뇨병환자의 왼손과 오른손의 말초혈관 탄성도 차이를 정상인과 비교해 보았다. 실험결과 당뇨병환자와 정상인의 양 손가자 말초혈관 탄성도의 유의한 차이를 확인 할 수 있었다.

  • PDF

Real-time Heart Rate Measurement based on Photoplethysmography using Android Smartphone Camera

  • Hoan, Nguyen Viet;Park, Jin-Hyeok;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.234-243
    • /
    • 2017
  • With the development of smartphone technologies enable photoplethysmogram (PPG) acquisition by camera and heart rate (HR) measurement. This papers presents improved algorithm to extract HR from PPG signal recorded by smartphone camera and to develop real-time PPG signal processing Android application. 400 video samples recorded by Samsung smartphone camera are imported as input data for further processing and evaluating algorithm on MATLAB. An optimized algorithm is developed and tested on Android platform with different kind of Samsung smartphones. To assess algorithm's performance, medical device Beurer BC08 is used as reference. According to related works, accuracy parameters includes 90% number of samples that has relative errors less than 5%, Person correlation (r) more than 0.9, and standard estimated error (SEE) less than 5 beats-per-minutes (bpm).

A Study of Biosignal Analysis System for Sensibility Evaluation (감성을 평가하기 위한 생체신호 분석 시스템에 관한 연구)

  • Lee, Ji-Hyeoung;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.35-38
    • /
    • 2010
  • 본 논문에서는 일상생활 속에서 무자각적으로 생체신호를 측정하고 분석하여 감성을 평가할 수 있는 임베디드 시스템에 관하여 연구하였다. 지속적으로 변화하는 감성을 일관적이며 신뢰성이 높은 생리적인 방법으로 평가하기 위해 심전도(ECG:Electrocardiogram), 맥파(PPG:Photoplethysmogram)의 두 가지 생체신호를 측정하고, 무선전송(Bluetooth) 장치를 이용하여 측정한 생체신호를 실시간으로 노트북PC로 전송하여 분석하였다. 생체신호의 분석방법은 FFT(Fast Fourier Transform)과 전력스펙트럼밀도(Power Spectrum Density)를 이용한 주파수 분석방법으로 두 생체신호의 특정 주파수 대역이 가지는 자율신경계의 활성도의 비율을 분석하여 비교 연구하였다. 또한 보다 빠르고 정확한 감성을 평가하기 위하여 분석알고리즘의 연산을 최소화 하였으며 그래프를 이용한 분석결과의 시각화를 하였다. 본 논문에서는 무자각적인 생체신호 측정 시스템을 이용하여 다양한 상황에서 생체신호를 측정하고, 개발한 분석 알고리즘으로 분석한 결과의 차이를 연구하여 정확도 및 신뢰도를 기준으로 감성을 평가하기 위한 분석 시스템을 평가하였다.

  • PDF

Gender-Related Differences in the Second Derivative of Photoplethysmogram Waveforms in the Fourth Decade (30대 성인남녀의 성별에 따른 가속도맥파 차이에 관한 연구)

  • 남동현;박연재;박영배
    • The Journal of Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • Objective: There exist gender differences in pulsatile contour waveform. Women have a greater age-related increase in left ventricular mass than do men and more likely to experience symptomatic heart failure after infarction. SDPTG (the second derivative of photoplethysmogram waveform) is a noninvasive method for evaluating the pulse wave and is correlated with age and other risk factors for atherosclerosis. We studied the effect of gender on SDPTG and made clear why the gender differences appear. Methods: To study the effects of effect factors, including height and blood pressure, on SDPTG in the fourth decade, data on height, weight, PTD (pulse transit distance), blood pressure, serum lipid levels, and SDPTG were collected in 115 laboratory healthy men and women. SDPTG is derived from double-differential processing of fingertip photoplethysmography and consists of a, b, c, and d waves in systole and an e wave in diastole; SDPTG aging index (AI) was calculated as (b-c-d-e)/a. Results: There were significant gender-related differences of SDPTG AI, height, and blood pressure. Age, height, and mean blood pressure were respectively and significantly correlated with SDPTG AI. SDPTG is dependent upon age, height, and blood pressure. Restricting analysis to SDPTG AI, age, height, and mean blood pressure, yielded that there were gender-related differences in SDPTG AI (P<0.05) which were derived from those of height (F<0.001, df=l, P=0.994). Conclusions: These new data may help to explain previous findings about age-related differences in pulsatile contour waveforms and why gender differences of SDPTG appear. The results of this study suggest that SDPTG AI, used for evaluation of biological vascular aging, should be calibrated by height as well as age and blood pressure.

  • PDF