Fourth-order interference between perpendicularly polarized beams with different intensities in a HOM interferometer (HOM 간섭계에서 세기가 다른 수직편광된 빔사이의 4차 간섭)

  • Kim, Heon-Oh;Kim, Tae-Soo;Ko, Jeon-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.2
    • /
    • pp.116-121
    • /
    • 2003
  • We have observed a nonclassical effect in a fourth-order interference experiment with the photon pairs produced by parametric down-conversion and the Hong-Ou-Handel interferometer. For interfering classical fields with orthogonal polarizations, the visibility can be no larger than 50%, and it depends on the ratio of the two beam intensities. It is found that not only is our observed visibility of 85% well above 50%, but it is also independent of the two beam intensities in coincidence measurements made in a two-photon polarization correlation experiment.

Monte Carlo approach for calculation of mass energy absorption coefficients of some amino acids

  • Bozkurt, Ahmet;Sengul, Aycan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3044-3050
    • /
    • 2021
  • This study offers a Monte Carlo alternative for computing mass energy absorption coefficients of any material through calculation of photon energy deposited per mass of the sample and the energy flux obtained inside a sample volume. This approach is applied in this study to evaluate mass energy absorption coefficients of some amino acids found in human body at twenty-eight different photon energies between 10 keV and 20 MeV. The simulations involved a pencil beam source modeled to emit a parallel beam of mono-energetic photons toward a 1 mean free path thick sample of rectangular parallelepiped geometry. All the components in the problem geometry were surrounded by a 100 cm vacuum sphere to avoid any interactions in materials other than the absorber itself. The results computed using the Monte Carlo radiation transport packages MCNP6.2 and GAMOS5.1 were checked against the theoretical values available from the tables of XMUDAT database. These comparisons indicate very good agreement and support the conclusion that Monte Carlo technique utilized in this fashion may be used as a computational tool for determining the mass energy absorption coefficients of any material whose data are not available in the literature.

POLARITY AND ION RECOMBINATION CORRECTION FACTORS OF A THIMBLE TYPE IONIZATION CHAMBER WITH DEPTH IN WATER IN THE MEGAVOLTAGE BEAMS

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.43-48
    • /
    • 2009
  • When the PDD (percentage depth dose) in the megavoltage beams is measured in the water phantom, the polarity and ion recombination effects of ionization chambers with depth in water are not usually taken into consideration. We try to investigate if those variations with depth should be taken into consideration or could be ignored for the thimble type semiflex ionization chamber (PTW $31010^{TM}$, SN 1551). According to the recommendation of IAEA TRS-398, the 4 representative depths of $d_s$, $d_{max}$, $d_{90}$ and $d_{50}$ were used for the electron beams. For the photon beams, the 4 depths were arbitrarily chosen for the photon beams, which were $d_s$, $d_{max}$, $d_{10}$ and $d_{20}$. For the high energy photon beam both polarity and ion recombination factors of the chamber with depth in water gives the good agreements within the maximum $\pm$0.2%, while the $C_{polS}$ with depth came within the maximum $\pm$ 0.4% and the $C_{IRS}$ within the maximum $\pm$0.6% in every electron beam used. This study shows that PDI (percentage depth ionization) could be a good approximation to PDD for the chamber used.

Development of 2.5D Photon Dose Calculation Algorithm (2.5D 광자선 선량계산 알고리즘 개발)

  • 조병철;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.103-114
    • /
    • 1999
  • In this study, as a preliminary study for developing a full 3D photon dose calculation algorithm, We developed 2.5D photon dose calculation algorithm by extending 2D calculation algorithm to allow non-coplanar configurations of photon beams. For this purpose, we defined the 3d patient coordinate system and the 3d beam coordinate system, which are appropriate to 3d treatment planning and dose calculation. and then, calculate a transformation matrix between them. For dose calculation, we extended 2d "Clarkson-Cunningham" model to 3d one, which can calculate wedge fields as well as regular and irregular fields on arbitrary plane. The simple Batho's power-law method was implemented as an inhomogeneity correction. We evaluated the accuracy of our dose model following procedures of AAPM TG#23; radiation treatment planning dosimetry verifications for 4MV of Varian Clinac-4. As results, PDDs (percent depth dose) of cubic fields, the accuracy of calculation are within 1% except buildup region, and $\pm$3% for irregular fields and wedge fields. And for 45$^{\circ}$ oblique incident beam, the deviations between measurements and calculations are within $\pm$4%. In the case of inhomogeneity correction, the calculation underestimate 7% at the lung/water boundary and overestimate 3% at the bone/water boundary. At the conclusions, we found out our model can predict dose with 5% accuracy at the general condition. we expect our model can be used as a tool for educational and research purpose.. purpose..

  • PDF

Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example (GEANT4 Medical Linac2 예제를 이용한 6 MV 선형가속기 광자선속의 기초특성과 연구방법)

  • Kim, Byung-Yong;Kim, Hyung-Dong;Kim, Sung-Jin;Oh, Se-An;Kang, Jung-Gu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, Geant4 based Monte Carlo simulations were carried out for medical linear accelerator. Modified Medical Linac2 toolkit was used for calculation. The energy spectrum, most probable energy and the photon mean energy compared with the published results using the EGS4 code. The results well agreed with published results. The calculated results of photon fluence, energy fluence and mean energy according to the radius from the centre of the beam were analyzed. Monte Carlo simulation using Medical Linac2 code is considered to be useful for analysis of medical linear accelerator. Because the calculated results varies depending on Physics List model for same head structure. It it important to choose the right model for research purpose. Monte Carlo simulation using GEANT4 Medical Linac2 is a valuable for any novice to adopt this code to the study related to 6 MV photon fluence from medical linear accelerator.

Improvement of Beam-Quality Evaluation Method for Medical Linear Accelerator Using Magnetic Field

  • Kim, Jeongho;Han, Manseok;Yoo, Sejong;Kim, Kijin;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.120-128
    • /
    • 2015
  • Beam-quality of medical linac evaluations vary by diverse factors. Because conventional beam-quality evaluation methods yield fragmentary results, a new beam-evaluation method is suggested, and its feasibility is evaluated. The PDDs (percentage depth doses) of 6 MV (Mega-voltage) and 10 MV photon, R (Range) of a 6 MeV (Mega Electron-voltage) and 9 MeV electron were measured and compared with the conventional evaluation methods, and the improved methods $PDD^{10}{_5}$, $PDD^{20}{_{10}}$, $PDD^{30}{_{20}}$, $PDD^{20}{_5}$, $PDD^{30}{_{10}}$, and $R^{70}{_{50}}$, $R^{50}{_{30}}$, $R^{70}{_{30}}$ as the magnetic field of the bending magnet was changed to +2% to -2%, and the results were compared. The comparison showed that the improved methods exhibit a higher discrimination than the conventional methods in each energy regime. $PDD^{10}{_5}$, $PDD^{30}{_{20}}$, $PDD^{30}{_{10}}$ and $R^{70}{_{50}}$, $R^{50}{_{30}}$ should be applied. These methods exhibit a higher discrimination in each energy regime than conventional beam-quality evaluation methods; therefore, they should be used for beam-quality evaluation according to the magnetic field variation.

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.

The Evaluation of Multiplane-Parallel Chamber Using Crystal Plate as Ionization Medium for Therapeutic Radiation Beams

  • Young W. Vahc;Park, Kyung R.;Kim, Sookil;Chul W. Joh;Kim, Tae H.
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 1998
  • There has been necessity of an air free ionization chamber using the gold-crystal-aluminium plates, henceforth called the crystal chamber. The crystal chamber formed of parallel plates is very small in size and has more response for absorbed dose of therapeutic radiation beams. The gold plate on the crystal facing the photon and electron beam acts as an intensifier of signals and crystal plate as an ionization medium respectively. Both the copper guard ring and the aluminum collecting electrode are connected to an electrometer. Using high energy photon (6, 15 MV) and electron (9, 12, 15, 18 MeV) beams, the responses of the crystal chamber are evaluated against a PTW Farmer-type chamber at a field size of 10${\times}$10cm$^2$ and 100 cm SSD. The responses of crystal chamber for therapeutic radiation electron and photon beams are greater in magnitude by several order than Farmer. The crystal chamber has good linearity without correction factor C$\_$t,p/ with respect to the signals, a reading reproduction with good accuracy and precision less than 0.5%, and has other useful functions in measuring radiation beams.

  • PDF

Continuous Scanning Method for Improvement of Precision and Fabrication Efficiency of Two-Photon Stereolithography (연속적 스캐닝 방법을 이용한 이광자 광중합 공정의 제작 속도 및 정밀도 개선에 관한 연구)

  • Lim, Tae-Woo;Son, Yong;Yang, Dong-Yol;Kong, Hong-Jin;Lee, Kwang-Sup;Park, Sang-Hu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.5
    • /
    • pp.396-401
    • /
    • 2008
  • Minimization of processing time in two-photon stereolithography (TPS) has been one of important issues. Generally, a voxel scanning method (VSM) has been used in TPS because the method is very profitable for the stable fabrication irrespective of jittering and response time of scanning equipments such as a stage and a galvano-scanner. However, supplementary processing time due to the on/off control of a shutter for the generation of each voxel is required inevitably in VSM; by this reason, much processing time takes to fabricate largescale micropatterns and three-dimensional patterns. In this work, a continuous scanning method (CSM), generating patterns by movement of beam focus with a constant speed, is proposed for the improvements of scanning speed and precision in TPS. Some line patterns are fabricated by each scanning method to demonstrate the usefulness of CSM with viewpoints of scanning speed and precision.

Design Features and Operating Characteristics of the MM-22 Microtron for Radiotherapy (방사선 치료용 MM-22 마이크로트론의 설계 특징과 동작 특성)

  • Bak, Joo-Shik;Lee, Dong-Hun
    • Nuclear Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.380-388
    • /
    • 1990
  • The MM-22 medical microtron at Korea Cancer Center Hospital is now operational for high energy electron and photon therapy, This microtron is designed to produce 5.3-22.5 MeV electron beams and deliver these to the treatment head through beam transport system with an intensity and stability suitable for cancer treatment. The availability of high quality radiation modalities from the MM-22 shows new possibilities in the treatment of deep seated tumours. Principle of operation, system structures and operating characteristics of the MM-22 are described in this paper.

  • PDF