• 제목/요약/키워드: photoionization detector

검색결과 7건 처리시간 0.018초

산업현장에 활용되는 PID 직독식장비의 특성 고찰 (Review Paper for Characterization of Photoionization Detector-Direct Reading Monitors )

  • 김성호;박해동;황은송
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.93-102
    • /
    • 2023
  • Objectives: With the evolution of direct reading sensors, it is possible to monitor several substances through telecommunication. However, there are some limitations on the use of direct reading technologies in the Occupational Safety and Health Act in South Korea, which only applies to detector tubes, noise, heat, and carbon monoxides. The number of chemicals and their amount of use have been continuously increasing in South Korea. The Ministry of Employment and Labor (MoEL) has concerns about worker's health because exposure is only covered for about 1.2% of all distributed chemicals. Using a direct reading monitor with photoionization detectors (PID-DRMs), gases and vapors chemicals can be measured. Based on the data, business owners are able to create corrective strategies, provide better working routines, and select correct respiratory equipment. PID-DRMs are less expensive and easier to handle for an owner voluntarily controlling chemicals emitted in the workplace. However, there are several limitations on using these PID-DRMs to the degree that the MoEL has not been able to select a legal monitor. The aim of this study was to review previous studies related to PID-DRMs and identify the characterization and limitation on PID-DRMs. Methods: To search for related studies on PID-DRMs, key words were used including direct reading monitors/instruments and/or photoionization detectors. Through that, four domestic and 15 international studies were reviewed. Results: Studies on PID-DRMs were conducted by chamber (enclosed, dynamic, walk-in) and in the field (experimental environment, actual environment). The concentration of PID-DRMs and charcoal tubes were compared for a single substance or mixture, or within the PID-DRMs. There was a high correlation between the two concentrations, but it did not meet the accuracy criteria (95% confidence interval, within 25%) of the NIOSH technical report (2012). In addition, differences in measured values occurred according to environmental factors (temperature, humidity) and high concentration, and concentration values tended to be underestimated due to contamination of the sensor. As a way to improve the accuracy of PID concentration, it was proposed to use correction factors, charcoal tube-based correction factors, or to calibrate the PID-DRMs in the same environment as the workplace. Conclusions: PID-DRMs can likely be used by business owners for the purpose of voluntarily managing the workplace environment, and it is expected that it will be possible to use them as legal equipment if a PID sensor can be upgraded and the limitations of the sensor (temperature, humidity, high concentration evaluation, sensor pollution) can be overcome in the near future.

휴대용 광이온화 검출기의 정확도, 정밀도 및 기기간 차이에 대한 실험실 평가 (Laboratory Evaluation of the Accuracy, Precision, and Inter-instrumental Variance of a Portable Photoionization Detector)

  • 최동민;최영은;윤충식;이광원;이윤근;이익모;박정임
    • 한국산업보건학회지
    • /
    • 제22권3호
    • /
    • pp.200-208
    • /
    • 2012
  • Objectives: This study investigated the performance of three separate units of a portable photoionization detector (PID, ppb-RAE 3000) for measuring volatile organic compounds (VOCs) in a laboratory. Methods: A laboratory evaluation of the accuracy, precision, and inter-instrumental variance of three separate units of a portable PID (ppb-RAE 3000) was performed. The evaluation was based on the preparation of a test air sample of known toluene or ethylacetate concentration in a Tedlar$^{(R)}$ bag. The test air sample was monitored and data were logged consecutively by the three PIDs. A certified gas of 50 ppm toluene was also monitored during the test to ensure the reliability of the generated test air sample. Four different concentrations ranging from 0.1 to 2 TLV were used and a series of five measurements for each concentration level was performed. The accuracy was evaluated using National Institute for Occupational Safety and Health (NIOSH) criteria. Results: The results from the oldest ppb-RAE3000 unit among the three test units generally fell outside the NIOSH recommended accuracy criteria of ${\pm}25%$, whereas the other two units produced results which were acceptable at, or greater than, 25 ppm of toluene, or 0.5 TLV. These units also met the NIOSH criteria for some ethylacetate measurements but the results were not consistent. Conclusions: Considering the inconsistent performance of these ppb-RAE 3000 units, this device may not be appropriate for use as an alternative to the standard measurement methods. However, it can serve good survey instruments to identify exposure sources or concentration profiles. For all applications, the ppb-RAE 3000 should be used with frequent calibration checks, additional validation using a reference material, and careful maintenance.

휴대용 기체 크로마토그래피 / 광이온화 검출기 시스템의 개발 (Development of Portable Gas Chromatography / Photoionization Detector System)

  • 김만구;심지희;이동수;이용근
    • 대한화학회지
    • /
    • 제38권2호
    • /
    • pp.151-159
    • /
    • 1994
  • 기체시료 채취기와 짧은 모세관 컬럼(내경 0.32 mm, 길이 3 m), 광이온화 검출기 및 진공펌프로 구성되어, 컬럼의 출구 압력이 대기압보다 낮은 압력에서 조작되는 휴대용 기체 크로마토그래피 시스템을 개발하였다. 컬럼의 규격은 Golay식을 이용한 계산 결과를 기초로 선택하였으며, 조작압력비(컬럼입구와 출구압력비)는 1.03~1.2의 범위가 적절하였고, 이 조건에서 0.87∼4.63 ml/min의 걸럼유량을 얻을 수 있었다. 구경이 다른 3개의 튜브로 구성된 기체시료 채취기는 자동으로 기체시료를 직접 컬럼에 빠른 속도로 반복하여 도입할 수 있으며, 좋은 재현성을 나타내었다. 컬럼출구 압력이 대기압 이하에서 조작되며 짧은 모세관 컬럼을 사용하는 기체 크로마토그래피는 최적 컬럼유량이 일반적인 크로마토그래피보다 커 신속한 분석이 가능하여, 40초 이내에 m-xylene 과 o-xylene의 바탕선 분리가 가능하였다. 시스템의 분리능력에 영향을 주는 인자는 시료 채취시간, 컬럼의 길이와 내경 및 조작압력비였고, 벤젠 유도체들을 사용하여 이들의 영향을 검토하였다.

  • PDF

총휘발성유기화합물 측정 직독식장비 정확도 향상을 위한 현장보정계수 활용 연구 (Preliminary Study on Effect of the Field Correlation Factor for Increasing of the Accuracy in a Direct Reading Instruments on Photoionization Detector for Total Volatile Organic Compounds)

  • 김성호;이광용;김수진;박해동
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.67-76
    • /
    • 2024
  • Objectives: Direct reading instruments (DRIs) are widely used by industrial hygienists and other experts for preliminary survey and identifying source locations in many industrial fields. Photoionization detectors (PIDs), which are a form of hand-held portable DRIs, have been used for a variety of airborne vaporized chemicals, especially evaporated hydrocarbon solvents. The benefits of PIDs are high sensitivity between each chemical, competitive price, and portability. With the goal of increasing the accuracy of logged PID concentrations, previous studies have performed tests for the assessment of single chemical compounds, not mixtures. The purpose of this preliminary study was to measure mixtures with a PID and charcoal tube at the same time and compare the accuracy between them. Methods: A chamber test was implemented with different mixtures of hydrocarbon chemicals (acetone, isopropyl alcohol, toluene, m-xylene) and levels in the range of 14 to 864 ppm. Three PIDs and charcoal tubes were connected to the chamber and measured the chemical mixtures simultaneously. A comparison of accuracy and the PID group of concentrations with manufacture correction factor (M_CF) and field correction factor (F_CF) applied was performed. Results: The accuracy of the PID concentrations data-logged from the PID did not meet the accuracy criteria except for the mixture level B and C logged from PID No. 2, which was 18% of all tests for meeting accuracy criteria. The mean and standard deviation (SD) of concentration (ppm) of the charcoal tube followed by each mixtures' level were 10.37±0.26, 155.33±5.28, 300.80±11.65, and 774.93±22.65, respectively. When applying F_CF into the PID concentrations, the accuracy increased by nearly 82%. However, in the case of M_CF, none met the accuracy criterion. Between the PID there were differences of logged concentrations. Conclusions: In this preliminary study, the concentration of a logged PID with F_CF applied was a better way to increase accuracy compared to applying M_CF. We suggest that additional research is necessary to consider environmental factors such as temperature and humidity.

조선소 블록 도장시설에서의 휘발성 유기화합물과 총 탄화수소 농도측정 사례 (A Case Study on the Measurement Volatile Organic Compounds and Total Hydrocarbon Concentrations in Block Paint-Shops at a Shipyard)

  • 양성봉;유미선;우경빈
    • 한국환경과학회지
    • /
    • 제25권8호
    • /
    • pp.1177-1189
    • /
    • 2016
  • In order to prepare the information needed to construct a reduction system for volatile organic compounds (VOCs) exhausted from ship-block paint-booths in a giant shipyard, VOCs in paint-shop airs were analyzed and compared to the components in paint thinners. Aromatic hydrocarbons containing eight and nine carbon atoms are known to be major VOC compounds found in shipyard paint-shops. The total hydrocarbon (THC(C7)) concentrations calibrated using toluene gas, were measured in block paint-shops with two photo-ionization detector (PID) meters, and the resulting THC(C7) data were converted to THC(C1) concentrations according to the Standard Methods for the Measurements of Air Pollution in South Korea. THC(C1) concentrations near the spray site ranged from 10 to 2,000 ppm, but they were less than 400 ppm near the walls of the paint-booth. The measurements of THC concentrations, based on the height of the monitoring sites, were related to the height of the target to which the spray paints were applied. The maximum concentrations occurred at almost the same height as the spray targets. When painted blocks had been dried-by warming with no spraying, the THC concentrations were 80~100 ppm.

Soil-Gas의 분석을 이용한 휘발성 유기화합물 오염도 신속측정 (Rapid Measurement of VOC Using an Analysis of Soil-Gas)

  • 김희경;조성용;황경엽
    • 한국토양환경학회지
    • /
    • 제3권1호
    • /
    • pp.3-9
    • /
    • 1998
  • 본 연구는 휘발성 유기 화합물로 오염된 가솔린 지역에서 soil-gas의 분석결과로부터 오염도를 유추하는 기법에 대하여 서술 하였다. Soil-gas의 채취방법으로는 펌프를 이용한 1)grab sampling법과 흡착제 trap을 사용한 2)passive sampling법이 있다. Grab sampling법은 특정시간에 특정장소에서의 오염도를 보여주며, 반면에 passive sampling법은 특정위치에서 시간에 따른 오염도의 변화를 보여 준다. Soil-gas의 분석은 1)PID나 FID와 같은 작은 검지기에 의해서 총괄 탄화수소량을 측정할수도 있고 2)기체농도에 따라서 색깔이 변하는 지시약이 채워진 기체검지기 튜브를 사용할수도 있으며 3)여러가지 화합물을 한 번에 분석할수 있는 이동형 GC를 사용할수도 있다. Soil-gas를 이용한 측정법은 매우 값싸며 세밀한 정밀조사를 하기 위한 전단계에서 사용할 수 있는 유용한 방법으로 추천할만하다 하겠다.

  • PDF

직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구 (Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement)

  • 여진희;최광민
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.