• 제목/요약/키워드: photo nuclear reaction

검색결과 6건 처리시간 0.017초

A feasibility study on photo-production of 99mTc with the nuclear resonance fluorescence

  • Ju, Kwangho;Lee, Jiyoung;ur Rehman, Haseeb;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.176-189
    • /
    • 2019
  • This paper presents a feasibility study for producing the medical isotope $^{99m}Tc$ using the hazardous and currently wasted radioisotope $^{99}Tc$. This can be achieved with the nuclear resonance fluorescence (NRF) phenomenon, which has recently been made applicable due to high-intensity laser Compton scattering (LCS) photons. In this work, 21 NRF energy states of $^{99}Tc$ have been identified as potential contributors to the photo-production of $^{99m}Tc$ and their NRF cross-sections are evaluated by using the single particle estimate model and the ENSDF data library. The evaluated cross sections are scaled using known measurement data for improved accuracy. The maximum LCS photon energy is adjusted in a way to cover all the significant excited states that may contribute to $^{99m}Tc$ generation. An energy recovery LINAC system is considered as the LCS photon source and the LCS gamma spectrum is optimized by adjusting the electron energy to maximize $^{99m}Tc$ photo-production. The NRF reaction rate for $^{99m}Tc$ is first optimized without considering the photon attenuations such as photo-atomic interactions and self-shielding due to the NRF resonance itself. The change in energy spectrum and intensity due to the photo-atomic reactions has been quantified using the MCNP6 code and then the NRF self-shielding effect was considered to obtain the spectrums that include all the attenuation factors. Simulations show that when a $^{99}Tc$ target is irradiated at an intensity of the order $10^{17}{\gamma}/s$ for 30 h, 2.01 Ci of $^{99m}Tc$ can be produced.

MCNPX를 이용한 방사선 치료실의 광중성자 선량 평가 (Evaluation of Photoneutron Dose in Radiotherapy Room Using MCNPX)

  • 박은태
    • 한국콘텐츠학회논문지
    • /
    • 제15권6호
    • /
    • pp.283-289
    • /
    • 2015
  • 현재 방사선치료는 치료효과를 높이기 위해 고에너지 광자선의 사용이 증가하고 있는 추세이다. 일반적으로 6~8 MeV 이상의 고에너지 광자선을 사용하는 경우에는, 광핵반응에 의한 광중성자가 발생됨으로써 방사선 방호의 측면에서 많은 문제를 야기 시킬 수 있다. 이에 본 연구는 MCNPX를 이용하여 방사선 치료실의 광중성자 선량분포를 분석하였다. 그 결과 10 MV와 12 MV 구간에서 급격한 흡수선량의 증가를 보였다. 이를 통해 10 MV를 시작으로 광중성자 플루언스의 급격한 증가가 흡수선량으로 연계됨을 알 수 있었다. 또한 산출된 흡수선량을 바탕으로 등가선량을 환산한 결과는 ICRP 103 권고안의 경우, 낮은 에너지 범위에서 인체의 흡수선량에 대한 2차 광자의 기여를 반영함으로써 ICRP 60 권고안에 비해 낮은 등가선량을 나타냈다.

Studies on decomposition behavior of oxalic acid waste by UVC photo-Fenton advanced oxidation process

  • Kim, Jin-Hee;Lee, Hyun-Kyu;Park, Yoon-Ji;Lee, Sae-Binna;Choi, Sang-June;Oh, Wonzin;Kim, Hak-Soo;Kim, Cho-Rong;Kim, Ki-Chul;Seo, Bum-Chul
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1957-1963
    • /
    • 2019
  • A UVC photo-Fenton advanced oxidation process (AOP) was studied to develop a process for the decomposition of oxalic acid waste generated in the chemical decontamination of nuclear power plants. The oxalate decomposition behavior was investigated by using a UVC photo-Fenton reactor system with a recirculation tank. The effects of the three operational variables-UVC irradiation, H2O2 and Fenton reagent-on the oxalate decomposition behavior were experimentally studied, and the behavior of the decomposition product, CO2, was observed. UVC irradiation of oxalate resulted in vigorous CO2 bubbling, and the irradiation dose was thought to be a rate-determining variable. Based on the above results, the oxalate decomposition kinetics were investigated from the viewpoint of radical formation, propagation, and termination reactions. The proposed UVC irradiation density model, expressed by the first-order reaction of oxalate with the same amount of H2O2 consumption, satisfactorily predicted the oxalate decomposition behavior, irrespective of the circulate rate in the reactor system within the experimental range.

방사선치료실 내의 광중성자 에너지 분포 평가 (Evaluation of Photoneutron Energy Distribution in the Radiotherapy Room)

  • 박은태;고성진;김정훈;강세식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.223-231
    • /
    • 2014
  • 의료용의 선형가속장치는 방사선치료에 있어서 그 활용도가 가장 높으며, 최근에는 10MV 이상의 고에너지 광자선을 이용한 치료가 보편화되고 있다. 그러나 광핵반응에 의한 광중성자가 생성됨으로써 방사선 방호측면에서 많은 문제를 야기 시키고 있다. 이에 본 연구는 MCNPX 프로그램을 이용하여 치료실 내의 위치별 중성자의 특성을 분석하였다. 그 결과, 광중성자의 생성 개수도 선원 중심점을 기준으로 거리가 멀어질수록 감소됨을 알 수 있었다. 그리고 10MV에서 20MV로 에너지가 높아짐에 따른 열중성자와 속중성자의 비율은 큰 차이가 없었지만, 선원 중심점으로부터 거리가 이격될수록 열중성자의 비율이 높아지는 현상을 확인할 수 있었다.

나노 ZnO 입자가 코팅된 판상 분체의 합성과 사용감 증진 효과에 대한 연구 (The Study of Plate Powder Coated Nano Sized ZnO Synthesis and Effect of Sensory Texture Improvement)

  • Jin-Hwa , Lee;Ju-Yeol, Han;Sang-Gil, Lee;Hyeong-Bae, Pyo;Dong-Kyu, Lee
    • 대한화장품학회지
    • /
    • 제30권2호
    • /
    • pp.173-180
    • /
    • 2004
  • 20-30nm 크기를 갖는 나노 사이즈 ZnO 입자는 염료, 러버 첨가제, 가스 센서, 바리스터, 감광제와 광촉매로서 여러 산업분야에서 사용되고 있다. 반면에 화장품 산업에서는 나노 미터 크기의 ZnO 입자는 UV 차단물질과 자연스러운 메이크업 효과를 증진시키는 소재로서 사용되고 있다. 그러나 순수 ZnO 입자는 화장품에 적용했을 때 사용감 악화로 인해 그 사용량이 제한되고 있는 실정이다. 따라서 본 논문에서는 사용감은 판상 분체의 특성을 갖으면서 ZnO 본연의 특성을 유지하는 분체를 합성하기 위해 화장품 산업에서 널리 사용되고 있는 세리사이트, 보론나이트라이드, 비스무스옥시클로라이드와 같은 판상분체에 나노 사이느 ZnO가 코팅된 고기능성 무기복합분체를 하였다. 본 논문에서는 열수침전법에 의해 무기복합분체를 합성하였다. Zn원으로서 ZnCl$_2$가 사용되었고 침전제로는 hexamethylenetetramine(HMT)과 urea를 사용하였다. 실험변수로서 출발물질의 농도, 침전제의 종류, 핵생성제의 농도, 반응온도와 반응시간을 변화시켜 실험하였다. 합성된 무기복합분체의 형태, 결정상 변화, 열특성, UV-차단효과를 관찰하기 위해 각각 FE-SEM, XRD, FT-IR, TGA-DTA, In vitro SPF 테스터 기기를 이용하여 확인하였다. 합성된 무기복합분체를 메이크업 제품에 적용시켜 사용감 테스트하였다. 본 실험 결과 판상분체의 종류에 상관없이 일정한 합성조건 범위에서 나노크기 ZnO 입자가 균일하게 코팅되었다. 코팅된 판상분체를 프레스트 파우더제품에 적용시켜 사용자 테스트한 결과 판상분체 특유의 광택은 현저히 감소되는 반면 자연스러운 화장 연출, 사용감 개선 및 부착력 향상 효과를 얻을 수 있었다.

전립선암 방사선치료 시 광자극발광선량계를 이용한 광중성자선량 평가 (Evaluation of Photoneutron Dose for Prostate Cancer Radiation Therapy by Using Optically Stimulated Luminescence Dosimeter (OSLD))

  • 이주아;백금문;김연수;손순룡;최관우;유병규;정회원;정재홍;김기원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.125-134
    • /
    • 2014
  • 본 연구는 전립선암의 방사선치료에 적용되는 치료기법별 세기조절방사선치료의 적절한 조사문수의 선택 및 광중성자 피폭을 고려한 방사선 치료계획 수립을 위한 기초자료를 제공하고자 하였다. 연구대상은 2013년 9월부터 2014년 1월까지 5개월 동안 전립선암으로 방사선치료를 받은 환자 10명을 대상으로 하였다. 그리고 3-dimensional conformal radiotherapy (3D-CRT), volumetric-modulated arc radiotherapy (VMAT), intensity modulated radiation therapy (IMRT) 5, 7, 9 조사문으로 각각 치료계획을 수립하였다. 기술통계와 분산분석으로 광중성자선량의 평균적 차이를 비교하였으며, 상관관계분석과 회귀분석으로 상관성 및 영향을 분석하였다. 연구 결과, 치료기법별로는 3D-CRT가 가장 낮았다. 또한 IMRT가 가장 높게 측정되었으며, 통계적으로 매우 유의하였다 (p<.01). 세기조절방사선치료 조사문수별 광중성자선량은 평균 $4.37{\pm}1.08mSv$였으며, 조사문수 간에 통계적으로 매우 유의한 차이를 보였다(p<.01). 그리고 조사문수와 광중성자선량은 상관계수가 0.570으로 나타나 통계적으로 매우 유의한 양의 상관관계를 보였다 (p<.01). 조사문수와 광중성자선량의 선형회귀분석 결과, 조사문수가 1단계 증가할 때마다 평균적으로 광중성자선량이 0.373배로 유의하게 증가하였다. 결론적으로 전립선암의 방사선치료에 빈번히 사용하고 있는 IMRT의 조사문수의 선택 및 광중성자 피폭선량 및 방사선 치료계획의 질적 수준 평가를 고려한 적절한 치료계획 선택에 있어 기초자료로 활용될 수 있으리라 기대된다.