• 제목/요약/키워드: phenol detection

검색결과 85건 처리시간 0.018초

치아에서의 DNA 유전자지문 분석 -Chelex$^\textregistered$ 100을 매개체로 한 DNA추출- (Analysis of the DNA Fingerprints from the Teeth -Using Chelex$^\textregistered$ 100 as a Medium of Simple Extraction of DNA from the Teeth-)

  • Chang-Lyuk Yoon
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.515-528
    • /
    • 1995
  • The human genomic deoxyribonucleic acid(DNA) was extracted from the pulp, dentin of 22 teeth by clelex, phenol methods. Samples of the tooth-derived DNA were amplified by polymerase chain reaction(PCR), electrophosed for sex determination by detection of X-Y homologus amelogenin gene and D1S80 locus detection The following results have been achieved. 1. Chelex and phenol method are effective to sex determination in the pulp and dentin 2. Chelex method is not suitable for detection of D1S80 locus. 3. Concentration and purity of DNA for teeth using chelex method is lower than using phenol method. From the above investigation, chelex method is simple, rapid for sex determination, but it is not suitable for detection of VNTRs.

  • PDF

치아를 이용한 성별검사 및 D1S80 유전좌위의 검색시 4가지 DNA추출방법에 따른 비교 (Comparison of 4 Methods of DNA Extraction for Sex Determination and D1S80 Locus Detection in Teeth)

  • Woong Hur;Chang-Lyuk Yoon
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.497-513
    • /
    • 1995
  • Human genomic Deoxyribonucleic acid(DNA) was extracted from teeth by boiling, salting-out, phenol, boiling-phenol methods. The author compared DNA concentration and its purity, the accuracy of sex determination and the results of the D1S80 locus detection among above 4 methods. The following results were obtained : 1. DNA concentration was the highest in pulp with salting-out method and DNA purity was higher in pulp with salting-out and phenol methods than other 2 methods. 2. Sex determination was possible using of the pulp and the dentin of the teeth with four methods but, it was impossible in the enamel and some pulp with boiling method. 3. Amplification of D1S80 locus occurred from pulp and dentin with salting-out, phenol, and boiling-phenol methods. 4. There are no differences among the amplification of X-Y homologus amelogenin gene by application of 4 methods and salting-out, phenol methods efficiently makes available to amplification of D1S80 locus. From the investigation DNA extraction, sex determination, amplification of D1S80 locus was successfully accomplished with salting-out, phenol, boiling-phenol methods Therefore above 3 methods are available and applicable as forensic odontology for individual identification.

  • PDF

Ni Nanoparticle Anchored on MWCNT as a Novel Electrochemical Sensor for Detection of Phenol

  • Wang, Yajing;Wang, Jiankang;Yao, Zhongping;Liu, Chenyu;Xie, Taiping;Deng, Qihuang;Jiang, Zhaohua
    • Nano
    • /
    • 제13권11호
    • /
    • pp.1850134.1-1850134.10
    • /
    • 2018
  • Increasing active sites and enhancing electric conductivity are critical factors to improve sensing performance toward phenol. Herein, Ni nanoparticle was successfully anchored on acidified multiwalled carbon nanotube (a-MWCNT) surface by electroless plating technique to avoid Ni nanoparticle agglomeration and guarantee high conductivity. The crystal structure, phase composition and surface morphology were characterized by XRD, SEM and TEM measurement. The as-prepared Ni/a-MWCNT nanohybrid was immobilized onto glassy carbon electrode (GCE) surface for constructing phenol sensor. The phenol sensing performance indicated that Ni/a-MWCNT/GCE exhibited an amazing detection performance with rapid response time of 4 s, a relatively wide detection range from 0.01 mM to 0.48 mM, a detection limit of $7.07{\mu}M$ and high sensitivity of $566.2{\mu}A\;mM^{-1}\;cm^{-2}$. The superior selectivity, reproducibility, stability and applicability in real sample of Ni/a-MWCNT/GCE endowed it with potential application in discharged wastewater.

PVC 포장재에서 식품유사용매와 식품으로 이행되는 알킬페놀 (Migration of Alkylphenols from PVC Food Packaging Materials to Food Simulants and Foods)

  • 이선희;임흥열;신효선
    • 한국식품과학회지
    • /
    • 제33권4호
    • /
    • pp.416-422
    • /
    • 2001
  • 식품포장용 PVC제인 wrap, sheet 및 gasket으로부터 식품 유사용매와 식품으로 이행되는 알킬페놀류를 HPLC와 GC/MSD로 분석하였다. 세 가지 모든 재질에서 7개의 nonyl phenol 이성질체만이 검출되었고 다른 알킬페놀류는 검출되지 않았으며, wrap이 sheet와 gasket보다 그 함량이 높았다. 각 포장재질로부터 수용성 식품유사용매(증류수, 4% acetic acid, 20% ethanol)와 지용성 식품유사용매(n-heptane)에 의한 nonyl phenol의 용출량은 처리온도 $60^{\circ}C$보다는 $95^{\circ}C$에서, 수용성보다는 지용성 식품유사용매에서 각각 많았고, 또한 wrap에서 sheet와 gasket보다 그 양이 많았다. PVC gasket을 사용한 과일쥬스, olefin계 gasket을 사용한 유아용 쥬스, olefin계 병마개를 사용한 음료에서 nonyl phenol이 각각 포장재로부터 이행되었으며, 포장하기 전의 이들 식품에서도 nonyl phenol이 검출되었다.

  • PDF

RT-PCR에 의한 박 종자의 오이녹반모자이크바이러스 검정 (Detection of Cucumber green mottle mosaic virus in Bottle Gourd Seeds by RT-PCR)

  • 이숙경;송완엽;김형무
    • 식물병연구
    • /
    • 제10권1호
    • /
    • pp.53-57
    • /
    • 2004
  • CGMMV는 한국에서 수박의 주요 병원균이고, 수박 생산에 심각한 영향을 미친다. 이 연구에서는 박 종자의 CGMMV를 RT-PCR을 이용하여 신속하고 민감하게 검정하는 진단방법을 개발하였다. CGMMV-W의 외피 단백질 유전자 sequence에서 제작된 CGMMV에 특이적인 primer인 Wmfl과 Wmrl은 RT-PCR에 의해 420 bp의 증폭산물을 증폭하였다. RT-PCR에 의한 진단을 위하여 바이러스 추출과정을 간소화하고 종자 추출물의 반응 억제물질을 감소시키기 위해 ethanol 침전, double filtration, PEG 침전, phenol/chloroform/isoamyl alcohol에 의한 추출법을 비교하였으며 phenol/chloroform/isoamyl alcohol에 의 한 추출법이 민감성이 강한 방법으로 선발되었다. RT-PCR을 위해 선발된 primer들과 추출법은 1,000립의 건전 종자에 1립의 이병 종자를 혼합한 수준까지 판별이 가능하였다. 신속하고 민감한 RT-PCR에 의한 본 검정방법은 높은 반응 억제물질을 함유하는 박 종자에서 CGMMV의 특이적인 진단을 위해 유용한 방법이다.

Determination of Derivatives of Phenol with a Modified Electrode Containing β-Cyclodextrin

  • 김신희;원미숙;심윤보
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권4호
    • /
    • pp.342-347
    • /
    • 1996
  • Voltammetric determination of phenol derivatives, such as phenol, o-, m-, and p-cresols was studied with a β-Cyclodextrin (β-CD) modified-carbon paste electrode composing of the graphite powder and Nujol oil. Phenol derivatives were chemically deposited via the complex formation with β-CD by immersing the CME into a sample solution. The resulting surfaces were characterized with cyclic and differential pulse voltammetry. Treating the CME with 1 M nitric acid for five sec after a measurement could regenerate the electrode surface. Linear sweep and differential pulse voltammograms were recorded for the above system to optimize the experimental parameters for analysing the phenol derivatives. In this case, the detection limit for phenols was 5.0×10-7M for 25 min of the deposition time with differential pulse voltammetry. The relative standard deviation was ±5.2% of 3.0×10-6M (four repetitions). The interference effect of the following organic compounds was also investigated; Bezoic acid, hippuric acid, o-, m-, and p-methylhippuric acid. Adding the organic compounds into the sample solution reduces the peak current of the phenols to about 25%.

Bisphenol A and the related alkylphenol contaminants in crustaceans and their potential bioeffects

  • Zuo, Yuegang;Zhu, Zhuo;Alshanqiti, Mohammed;Michael, Joseph;Deng, Yiwei
    • Advances in environmental research
    • /
    • 제4권1호
    • /
    • pp.39-48
    • /
    • 2015
  • Bisphenol A is widely used in plastic and other industrial consumer products. Release of bisphenol A and its analogues into the aquatic environment during manufacture, use and disposal has been a great scientific and public concern due to their toxicity and endocrine disrupting effects on aquatic wildlife and even human beings. More recent studies have shown that these alkylphenols may affect the molting processes and survival of crustacean species such as American lobster, crab and shrimp. In this study, we have developed gas chromatography with flame ionization detection (GC-FID) and gas chromatography-mass spectrometric (GC-MS) methods for the determination of bisphenol A and its analogues in shrimp Macrobrachium rosenbergii, blue crab Callinectes sapidus and American lobster Homarus americanus samples. Bisphenol A, 2,4-bis-(dimethylbenzyl)phenol and 4-cumylphenol were found in shrimp in the concentration ranges of 0.67-5.51, 0.36-1.61, and < LOD (the limit of detection)-1.96 ng/g (wet weight), and in crab of 0.10-0.44, 0.13-0.62, and 0.26-0.58 ng/g (wet weight), respectively. In lobster tissue samples, bisphenol A, 2-t-butyl-4-(dimethylbenzyl)phenol, 2,6-bis-(t-butyl)-4-(dimethylbenzyl)phenol, 2,4-bis-(dimethybenzyl)phenol, 2,4-bis-(dimethylbenzyl)-6-t-butylphenol and 4-cumylphenol were determined at the concentration ranges of 4.48-7.01, 1.23-2.63, 2.71-9.10, 0.35-0.91, 0.64-3.25, and 0.44-1.00 ng/g (wet weight), respectively. At these concentration levels, BPA and its analogs may interfere the reproduction and development of crustaceans, such as larval survival, molting, metamorphosis and shell hardening.

Methods for the Extraction of DNA from Water Samples for Polymerase Chain Reaction

  • Jung, Jae-Sung;Lee, Young-Jong
    • Journal of Microbiology
    • /
    • 제35권4호
    • /
    • pp.354-359
    • /
    • 1997
  • Methods for the extraction of DNA from water sample were approximated. Four different procedures of DNA extraction were carried out with pellets obtained from centrifugation of 4 liter water samples. The recovery efficiency and purity of DNA extracted by each method from different sources were compared. DNA yield varied with extraction methods, Method I, which involves enzymatic and freeze-thaw lysis steps and phenol and phenol-chloroform purification of extracted nucleic acid, showed a significantly higher yield and purity than the other methods. The use of glass beads in the DNA extraction methods improved the purity of DNA suitable for PCR. Bovine serum albumin in the PCR reaction mixture was useful in reducing inhibitory effects of contaminants. The efficiency of an extraction method was determined by the detection of the aer of Aeromonas hydrophila with PCR. The lower limit of detection of A. hydrophila from seeded tap water was 2 CFU/ml in PCR when method I was used for DNA preparation.

  • PDF

흡착관/열탈착 GC/MS 방법에 의한 모사시료 중의 미량 페놀 분석에 관한 평가 (Evaluation of the Measurement of Trace Phenols by Adsorption/Thermal Desorption/Gas Chromatography/Mass Spectrometry (ATD/GC/MS) in Artificial Air)

  • 허귀석;이재환;황승만;정필갑;유연미;김정우;이대우
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.127-137
    • /
    • 2002
  • Phenolic compounds in air are toxic even at their low concentrations. We had evaluated a total of five phenolic compounds (Phenol, o-Cresol, m-Cresol, 2-Nitrophenol and 4-Chloro-3-methylphenol) in artificial air using a combination of ATD/GC/MS. To compare the adsorption efficiency of these phenolic compounds, three adsorbents (Tenax TA, Carbotrap and Carbopack B) were tested. Tenax TA adsorbent was most effective of all the adsorbents used for the efficiency test. Five phenolic compounds were found to be very stable on adsorbent tubes for 4 days at room temperature. Detection limit of five phenolic compounds ranged from 0.05 to 0.08 ppb (when assumed to collect 10 L air). The calibration curve was linear over the range of 22∼ 164 ng. The reproducibility was less than 4%. Sampling of duplicate pairs (DPs) was made to demonstrate duplicate precision and sampling efficiency.

HPLC에 의한 목초액 중의 유기산, 페놀 및 벤조피렌의 분석법 개발 (HPLC Analysis of Organic Acids, Phenol, and Benzopyrene in Wood Vinegar)

  • 이계원;김아람;조재수
    • 약학회지
    • /
    • 제52권1호
    • /
    • pp.12-19
    • /
    • 2008
  • The organic acids (formic acid, acetic acid and propionic acid), phenol and benzopyrene in wood vinegar were determine by HPLC. An $Atlantis^{TM}dC_{18}$ column with a acetonitrile: 0.1% phosphoric acid (5: 95, organic acids), acetonitrile: water (10 : 90, phenol), 100% acetonitrile (benzopyrene) as a mobile phase was used. Retention time of acetic acid, formic acid, propionic acid, phenol and benzopyrene was 4.77, 3.73, 9.08, 30.97 and 6.10 min, respectively. The calibration curves of organic acids, phenol, benzopyrene were linear over the concentration range of $30{\sim}500,\;60{\sim}1000$, and $3{\sim}50\;{\mu}g/ml$ with correlation coefficient of above 0.999. The limit of detection (LOD) and limit of quantitation (LOQ) of acetic acid, formic acid, propionic acid, phenol, and benzopyrene was 1.71 and 5.19, 1.11 and 3.35, 4.87 and 14.74, 6.45 and 19.55, 0.08 and $0.24\;{\mu}g/ml$, respectively. The coefficients of variation for intra- and inter-day assay were $0.21{\sim}4.14$ and $0.07{\sim}1.19%$, respectively and the precision was $95{\sim}115%$. From this study, we suggest that HPLC is suitable method for the determination of organics in wood vinegar and could be applied to quality control of wood vinegar.