• 제목/요약/키워드: phased conversion

검색결과 15건 처리시간 0.023초

축별 분할된 PSO-FCM을 이용한 외란 감소방안: 함정용 레이더의 위상변화 적용 (The Reduction Methodology of External Noise with Segmentalized PSO-FCM: Its Application to Phased Conversion of the Radar System on Board)

  • 손현승;박진배;주영훈
    • 제어로봇시스템학회논문지
    • /
    • 제18권7호
    • /
    • pp.638-643
    • /
    • 2012
  • This paper presents an intelligent reduction method for external noise. The main idea comes from PSO-FCM (Particle Swam Optimization Fused fuzzy C-Means) clustering. The data of the target is transformed from the antenna coordinates to the vessel one and to the system coordinates. In the conversion, the overall noises hinder observer to get the exact position and velocity of the maneuvering target. While the filter is used for tracking system, unexpected acceleration becomes the main factor which makes the uncertainty. In this paper, the tracking efficiency is improved with the PSO-FCM and the compensation methodology. The acceleration is approximated from the external noise splitted by the proposed clustering method. After extracting the approximated acceleration, the rest in the noise is filtered by the filter and the compensation is added to after that. Proposed tracking method is applicable to the linear model and nonlinear one together. Also, it can do to the on-line system. Finally, some examples are provided to examine the reliability of the proposed method.

위상배열 EMAT의 제작 및 특성 평가 (Fabrication of Phased Array EMAT and Its Characteristics)

  • 안봉영;조승현;김영주;김기복
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.373-379
    • /
    • 2010
  • EMAT는 비접촉식 탐촉자인 동시에 모드 선택성이 우수하여 다양한 분야에 적용되고 있으나 근본적으로 에너지 전환효율이 낮아 신호 대 잡음비의 증가에 한계를 보인다. EMAT에 위상배열 기술을 접목하면 초음파의 집속 효과를 얻을 수 있으므로 낮은 전환효율의 문제를 극복하기 위한 하나의 해결방안이 될 수 있을 것으로 판단한다. 본 연구에서는 위상배열 EMAT에 대한 기초연구로 3~4개의 코일로 구성되는 표면파 및 수직횡파 발생용 위상배열 EMAT를 제작하고 각 요소코일에 공급하는 펄스의 지연으로부터 위상배열의 효과를 확인하고 방향특성을 측정하였다. 또한 시험편의 표면에 0.5 mm 깊이의 표면결함과 시험편 내부에 직경 0.5 mm의 측면 드릴 홀을 가공하여 제작된 위상배열 EMAT로 결함 신호를 검출하였으며, 이로부터 제작된 EMAT의 성능을 평가하였다.

능동 위상 배열 레이더의 디지털 수신기 제작 및 측정 (Design and Measurement of Active Phased Array Radar Digital Receiver)

  • 김태환;이성주;이동휘;홍윤석;조춘식
    • 한국전자파학회논문지
    • /
    • 제22권3호
    • /
    • pp.371-379
    • /
    • 2011
  • 최근의 다기능 레이더는 능동 위상 배열 안테나 구조를 이용하고 있다. 열약한 클러터 환경에서 표적을 탐지하기 위해서는 레이더 수신기의 동적 영역이 커야 한다. 능동 위상 배열 안테나 구조를 이용한 구조의 레이더는 SNR(Signal-to-Noise Ratio)를 향상시키지만, SFDR(Spurious Free Dynamic Range)은 개선되지 않는다. 본 논문에서는 높은 SFDR을 갖는 X-밴드 능동 위상 배열 레이더의 다채널 디지털 수신기를 설계하고 제작하였다. 32개의 T/R(Transmit/Receive) 모듈이 한 채널의 디지털 수신기와 연결되어 있다. 디지털 수신기내에 RF부, ADC부, 로컬 분배부 및 디지털 하향변환부가 존재하고, 한 개의 조립체 내에 2채널의 디지털 수신기가 포함되어 있다. 상용 FIFO 보드를 이용하여, 디지털 출력 신호에 대해, 디지털 수신기 주요 특성을 측정하였다. 제작된 디지털 수신기의 이득은 33 dB이고, SFDR은 81 dBc 이상이다.

I/Q 보정기능을 갖는 3차원 레이더 신호처리기용 고속 A/D 변환 기법 연구 (The study on high speed A/D conversion implementation employing I/Q compensating algorithm for 3-D radar signal processor)

  • 조명제;김수중
    • 전자공학회논문지S
    • /
    • 제34S권6호
    • /
    • pp.67-76
    • /
    • 1997
  • In radar signal processing, an A/D converter with sufficient dynamic range and high sampling speed is required to detect the weakest target signals in heavy clutter and ECM environments. As the sampling frequency increases, the amount of digital data transfered to the signal processing module is also increased. To overcome these massive data transfer burden, we need an A/D conversion module with an enough data transfer rate. In this paper, we proposed an implementation scheme of a new A/D conversio module that can be used in multi-mode 3-D phased array radar signal processing system, and evaluated the performance. The proposed A/D conversion module is implemented with a standard A/D converter and a 6U-standard VME bus.

  • PDF

차량용 레이더를 위한 26GHz 40nm CMOS 광대역 가변 이득 증폭기 설계 (26GHz 40nm CMOS Wideband Variable Gain Amplifier Design for Automotive Radar)

  • 최한웅;최선규;이은규;이재은;임정택;이경혁;송재혁;김상효;김철영
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.408-412
    • /
    • 2018
  • 이 논문에서는 40nm CMOS 공정을 이용하여 제작된 26GHz 가변 이득 증폭기에 대한 연구를 수행하였다. 79GHz를 사용하는 자동차 레이더의 경우 주파수 특성상 회로 전체를 79GHz로 설계 및 매칭 하기 보다는 Down conversion 하여 낮은 주파수대역으로 구동하거나 Up conversion 전에 낮은 주파수 대역을 이용하는 것이 설계 및 구동에 유리하다. 실제적으로 TTD(True Time Delay)를 통해 시간지연을 이용하는 Phased Array System 의 경우에도 현재 기술로는 낮은 주파수로 Down conversion하는 것이 오차를 줄이고 실제적 시간지연을 구현하는데 좋다. 79GHz 주파수의 1/3인 26GHz 주파수 대역에서 동작하는 VGA(Variable Gain Amplifier)에 대하여 설계하였고 1-stage의 cascode amplifier 형태로 구성된 회로에서 VDD : 1V, Bias 0.95V, S11은 < -9.8dB(Mea. High gain mode), S22 <-3.6dB(Mea. High gain mode), Gain : 2.69dB(Mea. High gain mode), P1dB : -15 dBm (Mea. High gain mode) 로 설계되었다. Low gain mode 에서는 S11은 < -3.3dB(Mea. Low gain mode), S22 < -8.6dB(Mea. Low gain mode), Gain : 0dB(Mea. Low gain mode), P1dB : -21 dBm (Mea. Low gain mode)로 설계되었다.

30kW급 발전시스템의 계통 연계형 인버터 개발 (Development of Grid Connection Type Inverter for 30kW Wind Power Generation System)

  • 함년근;강승욱;김용주;한경희;안규복;송승호;김동용;노도환;오영진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.990-992
    • /
    • 2002
  • 30kW electrical power conversion system is delveloped for the variable speed wind turbine system. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and frequency of generator output vary according to the wind speed, a dc/dc boosting chopper is utilized to maintain constant dc link voltage. Grid connection type PWM inverter supply currents into the utility line by regulating the dc link voltage. The active power is controlled by q-axis current which the reactive power can be controlled by d-axis current reference change. The phase angle of utility voltage is detected using s/w PLL(Phased Locked Loop) in d-q synchronous reference frame. This scheme gives a low cost power solution for variable speed WECS.

  • PDF

채석 완료 후 부지 활용성을 고려한 복구사례 분석 (Analysis of the Case of the Rehabilitation Quarrying After Using Quarrying Site)

  • 박재현;이준우;박종민
    • 한국환경복원기술학회지
    • /
    • 제13권3호
    • /
    • pp.152-162
    • /
    • 2010
  • This study provides preliminary data to support the need for appropriate and thorough restoration of quarries through investigating both domestic and overseas cases of sites that were restored in environment-friendly ways to make them re-usable after extraction. In cases of areas where it is difficult to restore the cut slope, putting it to other uses such as engraving buddhist images would be helpful to reduce the restoration cost and enhance the utilization of the slope. Phased land use conversion after exploitation needs to be considered in advance; for example, the location and size of the quarry should be determined according to the pre-planned use or development of the site. Considering the circumstances in the country, serious consideration should be given to methods that allow the restoration or recovery of the damaged sites to be completed in short periods of time. Quarry restoration needs to be approached from the view of ecological restoration and if a site is deemed to be usable for another purpose, land use conversion should be considered to enhance the utilization.

동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어 (Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator)

  • 송승호;김성주;함년근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

Demonstration of Adaptive Analogue Beam Forming in the E-Band

  • Dyadyuk, Val;Stokes, Leigh;Nikolic, Nasiha;Weily, Andrew R.
    • Journal of electromagnetic engineering and science
    • /
    • 제10권3호
    • /
    • pp.138-145
    • /
    • 2010
  • In this paper, we report the test results of a small-scale prototype that implements an analogue-beam-formed phased antenna array in the E-band. A four-channel dual-conversion receive RF module for 71~76 GHz frequency band has been developed and integrated with a linear end-fire antenna array. Measured performance is very close to the simulated results. An ad-hoc wireless communication system has also been demonstrated. Low BER was measured for an 8PSK data stream at 1.5 Gbps with the receive array beam formed in the direction of arrival of the transmitted signal. To our knowledge this is the first steerable antenna array reported to date in the E-band.

Phased Array Antenna Using Active Device

  • Seo, Chul-Hun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권6호
    • /
    • pp.306-309
    • /
    • 2004
  • This paper presents a new active antenna consisting of a microstrip patch for the passive radiator, a mixer for frequency conversion, a voltage controlled oscillator (VCO) and a phase detector for phase control. The microwave signal frequency has been converted into intermediate frequency (IF) on the antenna elements by the mixer. The active antenna consists of two ports, the IF port has a transmitted IF signal via power combined to the baseband and the dc control port is under the control of the phase-detector. The input voltage of the VCO is controlled by the phase detector. The scan range of the array is determined by the phase detector and the VCO and is obtained between 30$^{\circ}$ and - 30$^{\circ}$