• Title/Summary/Keyword: phase-to-ground fault

검색결과 143건 처리시간 0.021초

신경회로망을 이용한 배전선 사고 검출 기법의 개발 (Development of Fault Detection and Classification Method in Distribution Lines)

  • 김광호;최정환;장성일;강용철;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1114-1117
    • /
    • 1998
  • Recent applications of neural networks to power system fault diagnosis have provided positive results and have shown advantages in process speed over conventional approaches. This paper describes the application of neural network to fault detection and classification in distribution lines using the fundamental component, 2-5th harmonics index, even and odd harmonics index, and zero phase current. The Electromagnetic Transients Program (EMTP) is used to obtain fault patterns for the training and testing of neural networks. The proposed fault detection and classification method in distribution lines is obtained by analysing the difference among normal, HIF, ground fault, short circuit fault condition.

  • PDF

3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석 (Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL)

  • 박형민;최효상;조용선;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

2선 지락사고에 대한 저항형과 유도형 한류기의 전류제한특성 (Current limiting characteristics of the resistive and inductive SFCL in the double line-to-ground fault)

  • 최효상;현옥배;김상준;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1369-1372
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100${\Omega}$ of Quench impedance for a double line-to-ground fault, in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 17 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 12 kA, but with 3$\sim$5 kA of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

저항형과 유도형 한류기의 전류제한특성에 대한 EMTDC 해석 (EMTDC simulation for current limiting characteristics of the resistive and inductive SFCL)

  • 최효상;황시돌;현옥배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.255-258
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of quench impedance for a single line-to-ground fault. which accounts for about 70% of the total power line faults, in the 154 kV transmission system. The fault simulation at the phase angles 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 12 KA, but with 3 kA of DC component which decreased to zero in 5 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

이중여자 유도발전기를 이용한 가변속운전과 정속운전 풍력발전시스템의 운전특성 비교 (Comparison of Characteristics for Variable Operation using Doubly-fed Induction Generator and Fixed Speed Operation in Wind Turbine System)

  • 노경수;김태호
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1313-1320
    • /
    • 2009
  • This paper analyzes the steady-state operating characteristics of doubly-fed induction generator(DFIG) and fixed-speed induction generator(FSIG) in wind turbine system. It also presents a modeling and simulation of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink, and compares the responses between DFIG and FSIG wind turbine systems with respect to wind speed variation, 3-phase fault and 1-phase ground fault of the network. Simulation results show the variations of generator's active/reactive output, rotor speed, terminal voltage, fault current, etc. Case studies demonstrate that DFIG illustrates better performance compared to FSIG.

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

Study of Short-Circuit Currents Around Dĕtmarovice Power Station

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권3호
    • /
    • pp.117-124
    • /
    • 2014
  • The calculation of short-circuit currents is important for power systems operation and restoration, and for determining the means to protect human lives and properties. In this paper, a part of a power system network, around the D$\breve{e}$tmarovice power station in Czech Republic, was simulated by the well known program EMTP-ATPDraw (Electromagnetic Transients Program-Alternative Transient Program), and short-circuit currents and voltages were calculated at different points in the electric network and presented as a time function by the PlotXY program. Calculations were done just for phase-to-ground, and for the three-phase short-circuit at the Kun$\check{c}$ice substation. The results were important for determining the characteristics of the equipment required to withstand or break the short-circuit current; for this reason, the calculations were repeated using earth-fault resistances only for the case of busbar KUN shown in Figs. 5 and 6.

3상 태양광발전시스템의 계통연계운전 해석 (Analysis of 3 Phase utility interactive photovoltaic power generation system)

  • 김우현;김창일;김봉태;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.236-238
    • /
    • 1999
  • This paper presents a model and analysis results of 3 phase utility interactive photovoltaic power generation system. The control system is composed of feed forward, feedback and PID system. The voltage source inverter system provides sinusoidal PWM at current for the loads of utility system. A phase to ground fault and 3 phase fault are analyzed, and the results are discussed.

  • PDF

이산 웨이블릿 변환과 신경회로망을 이용한 FRTU의 고장판단 능력 개선에 관한 연구 (A Study for the Improvement of the Fault Decision Capability of FRTU using Discrete Wavelet Transform and Neural Network)

  • 홍대승;고윤석;강태구;박학열;임화영
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1183-1190
    • /
    • 2007
  • This paper proposes the improved fault decision algorithm using DWT(Discrete Wavelet Transform) and ANNs for the FRTU(Feeder Remote Terminal Unit) on the feeder in the power distribution system. Generally, the FRTU has the fault decision scheme detecting the phase fault, the ground fault. Especially FRTU has the function for 2000ms. This function doesn't operate FI(Fault Indicator) for the Inrush current generated in switching time. But it has a defect making it impossible for the FI to be operated from the real fault current in inrush restraint time. In such a case, we can not find the fault zone from FI information. Accordingly, the improved fault recognition algorithm is needed to solve this problem. The DWT analysis gives the frequency and time-scale information. The neural network system as a fault recognition was trained to distinguish the inrush current from the fault status by a gradient descent method. In this paper, fault recognition algorithm is improved by using voltage monitoring system, DWT and neural network. All of the data were measured in actual 22.9kV power distribution system.

스마트 그리드 배전 시스템을 위한 와이파이 통신에 기반한 디지털 FRTU간 통신 방법론 기초연구 (Communication Methodology Between Digital FRTUs Based on Wi-Fi Communication for the Smart Grid of Distribution System Area)

  • 진우경;윤지현;최민석;이재현;오간비렉;고윤석
    • 한국전자통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.1113-1120
    • /
    • 2022
  • 본 논문에서는 스마트 그리드 배전 시스템이 요구하는 디지털 FRTU(: Feeder Remote Terminal Unit)를 위한 통신 방법론을 연구하였다. 디지털 FRTU는 고장처리부와 통신부로 구성하는데, 고장처리부는 고장 시 고장정보를 통신부로 전송하며, 통신부는 주변 디지털 FRTU간 양방향 통신을 통해서 고장구간을 자율적으로 판별할 수 있도록 설계하였다. 성능 검증을 위해서 다양한 고장 시나리오들에 대한 고장모의가 가능하도록 3개의 디지털 FRTU를 기반으로 3개의 선로구간을 구성하는 하나의 성능 검증 시스템을 구축하였다. 구축된 성능 검증 시스템 상에서 1선 지락고장, 선간 및 3상 단락고장을 포함하는 다양한 고장 경우들을 실험적으로 모의하였으며, 각 경우에서 정확한 추론결과를 검증으로써 개발된 방법론의 유효성을 확인할 수 있었다.