• 제목/요약/키워드: phase-field method

검색결과 1,161건 처리시간 0.035초

EFFECT OF MAGNETIC FIELD ON LONGITUDINAL FLUID VELOCITY OF INCOMPRESSIBLE DUSTY FLUID

  • N. JAGANNADHAM;B.K. RATH;D.K. DASH
    • Journal of applied mathematics & informatics
    • /
    • 제41권2호
    • /
    • pp.401-411
    • /
    • 2023
  • The effects of longitudinal velocity dusty fluid flow in a weak magnetic field are investigated in this paper. An external uniform magnetic field parallel to the flow of dusty fluid influences the flow of dusty fluid. Besides that, the problem under investigation is completely defined in terms of identifying parameters such as longitudinal velocity (u), Hartmann number (M), dust particle interactions β, stock resistance γ, Reynolds number (Re) and magnetic Reynolds number (Rm). While using suitable transformations of resemblance, The governing partial differential equations are transformed into a system of ordinary differential equations. The Hankel Transformation is used to solve these equations numerically. The effects of representing parameters on the fluid phase and particle phase velocity flow are investigated in this analysis. The magnitude of the fluid particle is reduced significantly. The result indicates the magnitude of the particle reduced significantly. Although some of our numerical solutions agree with some of the available results in the literature review, other results differs because of the effect of the introduced magnetic field.

Far-field 위상 변조량 측정법을 이용한 광학매질의 비선형 특성 측정 (Measurement of the Nonlinear Optical Properties by use of the Far-Field Phase Modulation Method)

  • 김성훈;양준목;김용평;이영우;신동주;정영붕
    • 한국광학회지
    • /
    • 제9권3호
    • /
    • pp.168-174
    • /
    • 1998
  • 본 연구에서는 광학매질의 비선형 특징을 측정하기 위해, 자체집속현상을 이용하는 기존의 측정법과는 다르게, 매질을 통과한 광원의 위상섭동으로 인하여 far-field에 발생한 공간적 광장도 분포를 이용하는 far-field 위상 변조량 측정법을 사용하였다. 미선형 매질을 통과한 조사과의 위상 변화가 far-field 영역에서 나타나는 겅간적 위상 변조량을 실험적으로 측정아였고, 이를 전산시\ulcorner을 통하여 비교분석하였다. 파장 616nm, 펄스폭 106ps의 분포궤한 섹소레이저(DFDL)와 파장 308nm인 DFDL의 제2고조파를 조사광으로 사용하였고, 매질 $CS_2$$BaF_2$의 비선형 특성을 실험적으로 측정한후 이 값을 전산시늉값과 비교하였다. 이 실험에서 파장 616nm에 대해 $CS_2$$BaF_2$의 비선형 굴절률 $1.2{\times}10^{-11}$ esu와 $1.0{\times}10^{-13}$ esu를 각각 얻었고, 파장 308nm에 대해 $BaF_2$의 비선형 흡수계수 $5.0{\times}10^{-11}$cm/W를 얻었다. 이들 값은 지금까지 발표된 값들과 잘 일치한다.

  • PDF

NUMERICAL METHODS FOR CAVITATING FLOW

  • SHIN Byeong Rog
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2001년도 추계 학술대회논문집
    • /
    • pp.1-9
    • /
    • 2001
  • In this paper, some numerical methods recently developed for gas-liquid two-phase flows are reviewed. And then, a preconditioning method to solve cavitating flow by the author is introduced. This method employs a finite-difference Runge-Kutta method combined with MUSCL TVD scheme, and a homogeneous equilibrium cavitation model. So that it permits to treat simply the whole gas-liquid two-phase flow field including wave propagation, large density changes and incompressible flow characteristic at low Mach number. Finally, numerical results such as detailed observations of the unsteady cavity flows, a sheet cavitation break-off phenomena and some data related to performance characteristics of hydrofoils are shown.

  • PDF

다상 영구자석 동기전동기의 고장특성 해석에 관한 연구 (Faults Analysis and Dynamic Simulation Method for Poly-Phase PM Synchronous Motor)

  • 최세권;조준석;김주용;정태욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.826_827
    • /
    • 2009
  • This paper introduces major potential faults of Poly-Phase Permanent Magnet Synchronous Motor and their simulation realization methods. The faults of Poly-Phase PM Synchronous Motor, generally, stator turn faults, demagnetizing field. Based on the derived expressions, Poly-Phase PM synchronous Motor simulation model, which is capable of representing stator turn faults, is implemented in Maxwell.

  • PDF

이방향 여자형 SST를 이용한 이방성 전기강판의 인가자계 방향에 따른 2차원 자계특성 측정 (Measurement of 2 Dimensional Magnetic Property of Grain-oriented Electrical Steel Sheet According to Exciting Field Direction using SST with 2 Axes Excitation)

  • 음영환;김홍정;홍선기;신판석;고창섭
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.250-257
    • /
    • 2006
  • It is well known that Grain-oriented electrical steel sheets have two dimensional magnetic properties according to the direction of exciting field such as non-linear phase difference between magnetic flux density and magnetic field intensity vectors, different iron loss and permeability even when an alternating magnetic field is applied. The measurement and application of the two dimensional magnetic properties of the Grain-oriented electrical steel sheets, therefore, are very important for the design and precise performance analysis of electric machines made of them. As the direction of exciting field changes, in this paper, the two dimensional magnetic properties of a Grain-oriented electrical steel sheet, i.e., non-linear B-H curves, phase difference between B and H, and iron loss characteristics, are measured using SST(Single Sheet Tester) which has two axes excitation. The measured results are presented in two ways: using $(B,\theta_B)$ method and using hysteresis loops along rolling and transverse directions, respectively.

단상 영구자석형 유도동기기의 정상상태 특성해석 (Steady-State Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor)

  • 강규홍;남혁;홍정표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권2호
    • /
    • pp.53-60
    • /
    • 2003
  • This paper deals with steady-state analysis of a single-phase line-start permanent magnet synchronous motor. In order to analyze the steady-state characteristics, the asymmetric single-phase line-start synchronous motor is converted to the symmetric two-phase synchronous motor, that is, the asymmetric magnetic field is separated from the positive and the negative symmetric components using symmetrical-component theory. The analysis method of the synchronous motor on the d-q axis coordinates is used for the positive component and the equivalent circuit of the induction motor is applied for the negative component analysis. Moreover, d-q axis inductance considering current phase angle is applied to positive component analysis for precise characteristic analysis. In order to validate the proposed analysis method, the analysis results are compared with the experimental results.

Surface hydrophilicity modification of PVDF membranes with an external electric field in the phase inversion process

  • Shi, Bao-Li;Su, Xing;He, Jing;Wang, Li-Li
    • Membrane and Water Treatment
    • /
    • 제6권5호
    • /
    • pp.351-363
    • /
    • 2015
  • To increase the surface hydrophilicity of PVDF membranes, in this paper, an electric enhancing method was adopted to treat PVDF nascent membranes during the phase inversion process. It was found that when PEG 600 was taken as the additive, the surface water contact angle of the PVDF membrane treated under 2 kV electric field was decreased from $84.0^{\circ}$ to $65.7^{\circ}$. The reason for the surface elements change of the PVDF membranes prepared under the electric field was analyzed in detail with the dielectric parameters of the polymer dope solutions. Results from BSA adsorption experiment showed that the antifouling ability of the external electric field-treated membranes was distinctly enhanced when compared with that of the untreated membranes. The amount of BSA adsorbed by the treated membranes was lower by 38-43%. Compared with the common chemical reaction methods to synthesize hydrophilic additives or membrane materials, the electric field-assisted processing method did not involve any additional chemical synthesis process and it was capable of realizing better hydrophilicity.

THE CUPID CODE DEVELOPMENT AND ASSESSMENT STRATEGY

  • Jeong, J.J.;Yoon, H.Y.;Park, I.K.;Cho, H.K.
    • Nuclear Engineering and Technology
    • /
    • 제42권6호
    • /
    • pp.636-655
    • /
    • 2010
  • A thermal-hydraulic code, named CUPID, has been being developed for the realistic analysis of transient two-phase flows in nuclear reactor components. The CUPID code development was motivated from very practical needs, including the analyses of a downcomer boiling, a two-phase flow mixing in a pool, and a two-phase flow in a direct vessel injection system. The CUPID code adopts a two-fluid, three-field model for two-phase flows, and the governing equations are solved over unstructured grids with a semi-implicit two-step method. This paper presents an overview of the CUPID code development and assessment strategy. It also presents the code couplings with a system code, MARS, and, a three-dimensional reactor kinetics code, MASTER.

수동루프 설치에 의한 송전선로 자계 저감 (Mitigation of Transmission Line Magnetic Field by Installation of Passive Shield-Loop.)

  • 김정부;신구용;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권2호
    • /
    • pp.59-61
    • /
    • 2006
  • In our country most of transmission lines are double-circuit lines. In these lines, the combining method of increasing conductor height and installation of passive shield-loop to mitigate magnetic field near a transmission line, is a good and feasible method. The basic principle of passive shield loop is that the field from the current induced in the shield loop conductors counteracts the field from the phase conductors. This method applied to domestic transmission lines to meet the magnetic field level, 100, 30, 10 and 4 mG, respectively. In each magnetic field level, the minimum conductor height and passive loop height are presented for the implementation of the practical design.