• 제목/요약/키워드: phase-contrast

검색결과 840건 처리시간 0.031초

X-ray 미세 영상기법을 이용한 미세기포의 크기 및 속도 동시측정 (Synchrotron X-ray Micro-imaging Technique for Simultaneous Measurement of Size and Velocity of Micro-bubbles)

  • 김석;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1744-1748
    • /
    • 2004
  • It is important to measure precisely the size and velocity of micro-bubbles used in various field. The synchrotron X-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to their different refractive indices. The X-ray micro-imaging technique was found to measure an optical fiber with an accuracy of 0.2%. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}=2.7mm$) were tested to measure bubble size and up-rising velocity. For DI water, the measured velocity of micro-bubbles is nearly proportional to the square of bubble size, agreed well with the theoretical result. In addition, the synchrotron X-ray micro-imaging technique can measure accurately the size and velocity of several overlapped micro-bubbles.

  • PDF

X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정 (Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique)

  • 김석;이상준
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학 (3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT)

  • 김주헌;한성미;송현욱;서윤경;문용석;김홍태
    • 해부∙생물인류학
    • /
    • 제31권4호
    • /
    • pp.133-142
    • /
    • 2018
  • 조직표본의 실제적인 3차원 구조에 대한 정보를 3차원 조직학이라고 하였다. 무른 성분들이 섞여 있고, 물을 포함 하고 있는 조직 내부의 미세구조의 3차원적 분석을 위해 방사광의 X선을 광원으로 하는 위상대조 미세단층 촬영이 활용되고 있다. 하지만, X선 위상대조영상 분석에서 물을 포함하고 있는 조직에서는 위상대조가 제대로 구현되지 않다는 것을 알게 되었다. 이러한 현상을 해결하기 위해 다양한 방법들을 적용하였으며, 표본을 얼렸을 때 위상대조가 강화된다는 사실을 확인하였다. 방사광 전파위상대조 동결미세단층촬영은 포항가속기연구소 X선 영상빔라인에서 수행하였다. 표본을 동결상태로 유지하면서 $0.18^{\circ}$ 간격으로 $180^{\circ}$ 회전하였으며, 표본을 통과한 X선에 의해 섬광기에 맺힌 영상을 광학렌즈로 확대하여 CCD카메라로 모았다. 각 표본 전체 투사영상을 OCTOPUS 소프트웨어로 재구성하여 2차원 단면영상으로 만들고, Amira 소프트웨어를 이용하여 3차원 영상으로 재구성하였으며, 단면영상에서 각 구조에 대한 구역화와 랜더링 작업을 수행하였다. 물에 의한 위상대조 방해 영향을 줄이기 위해 표본을 얼렸을 때 위상대조는 강화되었으나 동결팽창에 의한 조직변형이 관찰되었다. 표본을 막힌 공간에 넣고 주위를 포매제로 채워 급속냉동 동안 표본이 압박되도록 하였을 때 위상대조의 강화와 동결팽창에 의한 조직변형을 줄일 수 있었다. 결론적으로, 생체조직 내부 미세구조의 비파괴, 고해상도 3차원 영상분석에 있어 조직표본을 동결포매제로 포매 후 급속냉동하고, 방사광에서 방출되는 X선을 광원으로 하는 전파위상대조 동결미세단층촬영법은 효과적인 방법이 될 수 있을 것으로 기대한다.

X-ray 미세 영상기법을 이용한 불투명 튜브 내부 미세기포의 크기 및 속도 동시 측정 (Simultaneous measurement of size and velocity of micro-bubbles in an opaque tube using X-ray micro-imaging technique)

  • 김석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.45-46
    • /
    • 2003
  • The x-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to different refractive index. Micro-bubbles of $20\~120{\mu}m$ diameter moving upward in an opaque tube $(\phi=2.7mm)$ were tested. For two different working fluids of tap water and DI water, the measured velocity of micro-bubbles is roughly proportional to the square of bubble size.

  • PDF

X-ray Micro-Imaging 기법 소개 및 불투명 튜브 내부의 마이크로 버블 가시화 연구 (X-ray Micro-Imaging Technique and Its Application to Micro-Bubbles in an Opaque Tube)

  • 이상준;김석;백부근
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.31-34
    • /
    • 2002
  • Imaging techniques using x-ray beam at high energies (>6KeV) such as contact radiography, projection microscopy, and tomography have been used to nondestructively discern internal structure of objects in material science, biology, and medicine. This paper introduces the x-ray micro-imaging method using 1B2 micro-probe line of PAL (Pohang Accelerator Laboratory). Cross-sectional information on low electron density materials can be obtained by probing a sample with coherent synchrotron x-ray beam in an in-line holography setup. Living organism such as plants, insects are practically transparent to high energy x-rays and create phase shift images of x-ray wave front. X-ray micro-images of micro-bubbles of $20\~120\;{\mu}m$ diameter in an opaque tube were recorded. Clear phase contrast images were obtained at Interfaces between bubbles and surrounding liquid due to different decrements of refractive index.

  • PDF

열화상 기술을 이용한 치아/복합레진 수복부의 박리 평가 (Evaluation of Delamination of Dental Composite Restoration using Infrared Lock-in Thermography)

  • 구자욱;최낙삼
    • Composites Research
    • /
    • 제25권6호
    • /
    • pp.236-240
    • /
    • 2012
  • 치과용 복합레진 수복재가 치아로부터 박리된 상태를 모사한 시편을 제작하고 위상잠금 적외선 열화상 기법을 이용하여 박리의 검출 가능성을 조사하였다. 내부 박리의 깊이와 가열 조건에 따른 검출 신호의 Amplitude와 Phase 이미지를 분석하였다. 내부 박리의 위치가 표면으로부터 0.5 mm 인 시편은 lock-in frequency = 0.05 Hz에서 건전부와 박리부의 Amplitude 차이가 가장 컸으며 1 mm와 1.5 mm 시편은 0.025 Hz와 0.01 Hz에서 Amplitude 차이로 박리부 검출이 가능하였다. Phase 변환 결과로부터 0.5 mm 시편은 0.006 Hz와 0.5 Hz 에서 뚜렷한 박리부의 이미지를 얻을 수 있었으며, 1 mm와 1.5 mm 시편은 0.006-0.1 Hz에서 박리부의 검출이 가능하였다.

위상잠금 열화상 기법의 최적 실험 조건 탐색 연구 (An Exploratory Study on the Optimized Test Conditions of the Lock-in Thermography Technique)

  • 조용진
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.157-164
    • /
    • 2011
  • 위상잠금 적외선 열화상(lock-in infrared thermography) 기법의 조선해양공학 분야에 적용 가능성을 검토하였다. 이를 위해 실험계획법에 의해 향상된 결함부와 건전부의 위상차 대비영상을 얻기 위한 탐색 연구를 수행하였다. 위상차 대비영상의 평가를 정량회하기 위하여 대비 기준표와 홀 크기에 가중치를 주는 방법을 적용하여 유용한 판별기준임을 입증하였다. 그리고 표면에 광 조사 세기는 중간이나 낮은 조사량이 좋은 결과를 보여주고, 높은 조사는 유용한 결과를 주지 못했다. 위상잠금 주파수는 가진 광원의 세기에 비례하여 좋은 결과를 획득할 수 있었고, 열화상 카메라의 노출시간(integration time)은 조사 광원의 세기와 반비례하여 실험을 수행하는 것이 좋은 결과를 얻을 수 있었다. 그러나 시험편(specimen)의 차이는 약간의 편향된 결과를 얻었지만 유의하지는 못했다.

소아 복부 CT 검사에서 체중에 기반한 조영제 주입 프로토콜 적용에 따른 조영증강의 최적화 (Contrast Optimization using of Weight-based Injection Protocol in Pediatric Abdomen CT Examination)

  • 김영균;한동균
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.575-584
    • /
    • 2021
  • 본 논문의 목적은 복부 CT 검사를 시행하는 소아환자에게 체중 기반 조영제 프로토콜을 적용함으로써 고정 투여법보다 조영제를 감소시키면서 최적의 문맥기 화질을 달성하는 것이다. Discovery 750HD(General Electric medical systems, Milwaukee, USA)를 이용하였으며, 만 18세 미만의 소아 남자 85명과 여자 82명, 총 167명을 대상으로 연구하였다. 300 mgI/ml(Xenetix, Guerbet, France)의조영제를 몸무게 2배로 고정 주입한 그룹과 체중기반 프로토콜을 적용하면서 주입량을 10%씩 단계적으로 감소시키면서 생리식염수를 주입한 그룹을 구분하였으며, 스캔 지연 시간을 추가로 변화시키면서 복부 장기의 CT 감쇄계수와 SNR을 비교 평가하였다. 또한 조영 증강의 정도와 심장 주변의 빔 경화 인공물을 정성적으로 평가하였다. 체중기반 프로토콜을 적용하고 20%의 조영제를 감소한 그룹이 몸무게 2배로 고정 주입한 그룹과 조영 증강이 가장 유사하였으며, 그리고 20%의 지연시간을 가진 그룹이 가장 조영 증강 효과가 높았다. 조영제 주입 후 적절한 지연시간은 실질 장기의 조영 효과를 상승시켰으며, 생리식염수를 적용한 주입 프로토콜은 심장 주변의 인공물이 감소시켰다. 결론적으로 소아 복부 CT 검사 시, 체중 기반 프로토콜의 적용과 적절한 지연시간의 조절은 불필요한 조영제 사용을 억제하고 최적의 문맥기 영상의 특성화를 가능하게 한다.

보령제약 중앙연구소 - 연구소 탐방

  • 백우현
    • 미생물과산업
    • /
    • 제20권1호
    • /
    • pp.50-52
    • /
    • 1994
  • Coccidioides immitis의 mycelial phase와 tissue phase에 있어서 미세구조를 다음과 같은 결론을 얻었다. 1. mycelial phase의 세포구조에서는 정상적인 균이 보유하고 있는 내용물질을 관찰할 수 있었으며 이는 다른 eucaryotic cell의 구조와 같았다. 2. tissue phase에서는 mycelial phase의 세포의 크기보다 비교적 크기가 컸으며 mycelial phase에서 보다 많은 종의 vacuole이 관찰되었다. 3. Tissue phase에서는 fibril form의 내연층을 볼 수 있었다.

  • PDF