• Title/Summary/Keyword: phase only filter

Search Result 168, Processing Time 0.027 seconds

Implementation of Ka-band Low Noise Block Converter For Satellite TVRO (Ka-band 위성방송수신용 저잡음 블록 변환기 구현)

  • Lim, Jin-Won;Kim, Tae-Jin;Park, Ju-Nam;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.2
    • /
    • pp.93-100
    • /
    • 2008
  • In this paper, Low Noise Block down converter(LNB) is designed for a Ka-band satellite television receiver only(TVRO) using commercially available MMIC. Designed Low Noise Block down-converter is composed of three stage amplifiers involving input noise matched at first amplification stage, image reject band pass filter, frequency mixer and intermediate frequency amplification. Through LNB Module power budget to obtain gain and attenuation, Optimum LNB devices satisfying Ka-band LNB technical specification are selected. Experimental results of designed Ka-band LNB yields conversion gain of over $58{\pm}1dB$, noise figure of less than 1.5dB and phase noise of -94.6dBc @10KHz.

  • PDF

The Characteristics and Optical Implementation of OA-pSDF BPOF (OA-pSDF BPOF의 특성 및 광학적 구현)

  • 임종태;박성균;엄주욱;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.8
    • /
    • pp.1433-1445
    • /
    • 1994
  • In this paper, an coherent optical correlator system based on the off-axis projection synthetic discriminant funtion (OA-pSDF) was analyzed and implemented optically. The filter was synthesized by combining conventional pSDF with single reference plane wave multiplexing. Synthesized pSDF were transformed to binary phase only filters (BPOFs) and fabricated as computer generated holograms(CGHs), which was used in the real time optical correlator system instead of using expensive spatial light modulators(SLMs). From the characteristic test, it was found that OA-pSDF showed distortion invariance and good performances in discrminating subset images. The proposed OA-pSDF BPOF could overcome the limitations of conventional BPOFs : that is distortion variance such as acale and rotation, especially out of plane variance.

  • PDF

Method for Simultaneous Determination of Cyanotoxins in Water by LC-MS/MS (액체크로마토그래프/질량분석기를 이용한 수중 남조독소물질 동시분석법)

  • Kim, Jeong-Hee;Yun, Mi-Ae;Kim, Hak-Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.597-605
    • /
    • 2009
  • Algae bloom occurred in reservoir in summer can cause taste and odor in water and disturb the flocculation and sedimentation processes in water treatment plant and cause sand filter plugging. It was also reported that microcystins, anatoxin and saxitoxin released from cyanobacteria had acute toxic effects on liver and nervous system. For these reasons, many advanced countries inclusive of WHO set the guideline for these toxins and cyanotoxins have been managed with regular monitoring in Korea as well. However, complex sample preparation steps such as a solid phase extraction (SPE) and derivatization are required with an existing analysis method with HPLC. We needed to improve an analysis method for low extraction efficiency and long sample preparation time. In this study, we have established a new LC/MS/MS method which can simultaneously determine 6 cyanotoxins (Microcystins-LR, Microcystins-RR, Microcystins-YR, Anatoxin-a, Saxitoxin, Neosaxitoxin) with only simple filtration step. When $75{\mu}L$ filterated sample was injected onto the LC-MS/MS, the recovery ranged from 86% to 112% and the MDL was $0.025{\sim}0.581{\mu}g/L$. We can make the MDL be lower than the guideline ($1{\sim}3{\mu}g/L$) of advanced countries with simple preparation.

A $2{\sim}6GHz$ Wide-band CMOS Frequency Synthesizer With Single LC-tank VCO (싱글 LC-탱크 전압제어발진기를 갖는 $2{\sim}6GHz$의 광대역 CMOS 주파수 합성기)

  • Jeong, Chan-Young;Yoo, Chang-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.74-80
    • /
    • 2009
  • This paper describes a $2{\sim}6GHz$ CMOS frequency synthesizer that employs only one LC-tank voltage controlled oscillator (VCO). For wide-band operation, optimized LO signal generator is used. The LC-tank VCO oscillating in $6{\sim}8GHz$ provides the required LO frequency by dividing and mixing the VCO output clocks appropriately. The frequency synthesizer is based on a fractional-N phase locked loop (PLL) employing third-order 1-1-1 MASH type sigma-delta modulator. Implemented in a $0.18{\mu}m$ CMOS technology, the frequency synthesizer occupies the area of $0.92mm^2$ with of-chip loop filter and consumes 36mW from a 1.8V supply. The PLL is completed in less than $8{\mu}s$. The phase noise is -110dBC/Hz at 1MHz offset from the carrier.

Comparison of the Sensitivity of Human Bronchial Epithelial Cells to Cigarette Smoke-induced Inflammatory Responses (인간 유래 폐 세포주별 담배연기 분획의 염증 반응 민감도 비교)

  • Yoo, Ji-Hye;Sohn, Hyung-Ok;Park, Chul-Hoon;Lee, Hyeong-Seok;Jang, Mi;Hyun, Hak-Chul;Shin, Han-Jae
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.32 no.1
    • /
    • pp.19-27
    • /
    • 2010
  • The aim of this study is to compare the sensitivity of both two NCI-H292 and A549 cell types to acute inflammatory responses induced by cigarette smoke. For this, we treated two kinds of smoke fractions derived from 2R4F reference cigarettes: total particulate matter(TPM) collected onto a Cambridge filter pad and gas/vapor phase(GVP) prepared by bubbling through in buffer solution. When we measured cellular cytotoxicity by neutral red uptake assay after treatment for 24 hours, TPM and GVP induced cytotoxic effect in a dose-dependent manner in the range of 10-$100{\mu}g$/mL and 60-$300 {\mu}g$/mL., respectively, in both cell types without any cellular difference. Additionally, when we examined acute inflammatory responses by analyzing cytokines secreted into culture media including tumor necrosis factor-$\alpha$ (TNF-$\alpha$), interleukin-8(IL-8), and transforming growth factor-$\alpha$(TGF-$\alpha$) as well as matrix metalloproteinase-1(MMP-1), the treatment with smoke fractions increased those marker proteins in a dose-dependent manner in NCI-H292. Meanwhile, in A549 cells only MMP-1 was observed to be increased in a dose-dependent fashion. Collectively, our data indicate that NCI-H292 cell type is more sensitive to cigarette smoke-induced inflammatory response than A549 cells. This suggests that NCI-H292 could be useful as an in vitro evaluation tool to assess harmful effects of cigarette smoke.

Design of a 16-QAM Carrier Recovery Loop for Inmarsat M4 System Receiver (Inmarsat M4 시스템 수신기를 위한 16-QAM Carrier Recovery Loop 설계)

  • Jang, Kyung-Doc;Han, Jung-Su;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.4A
    • /
    • pp.440-449
    • /
    • 2008
  • In this paper, we propose a 16-QAM carrier recovery loop which is suitable for the implementation of Inmarsat M4 system receiver. Because the frequency offset of ${\pm}924\;Hz$ on signal bandwidth 33.6 kHz is recommended in Inmarsat M4 system specification, carrier recovery loop having stable operation in the channel environment with large relative frequency offset is required. the carrier recovery loop which adopts only PLL can't be stable in relatively large frequency offset environment. Therefore, we propose a carrier recovery loop which has stable operation in large relative frequency offset environment for Inmarsat M4 system. The proposed carrier recovery loop employed differential filter-based noncoherent UW detector which is robust to frequency offset, CP-AFC for initial frequency offset acquisition using UW signal, and 16-QAM DD-PLL for phase tracking using data signal to overcome large relative frequency offset and achieve stable carrier recovery performance. Simulation results show that the proposed carrier recovery loop has stable operation and satisfactory performance in large relative frequency offset environment for Inmarsat M4 system.

The Design and Implementation of S/W Packet Modem based on Frequency Hopping Legacy Radio System (재래식 주파수도약 통신장비용 S/W 패킷모뎀 개발 및 적용에 관한 연구)

  • Koo, Jung;Pyo, Sang-Ho;Kang, Kyeong-Sung;Kim, Ki-Hyung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.222-231
    • /
    • 2011
  • In this paper, we have proposed a method which can make it possible to stably transmit and receive data like the ARC-164 radio frequency hopping environment as a S/W packet modem with PSK modulation. This is a method that the S/W packet modem with PSK digital modulation and the use of PC sound cards change over from data to voice signals and then transmit/receive data. We confirmed not only that it is possible to solve the slow speed communication with the use of sending data through multi-channels and PSK modulation that has the ability to methodically improve transmission rates, but also that it is possible to send the state of frequency hopping stably. In conclusion, we've confirmed both tactical values that though the transmission rate may be a tad slow, a state of frequency hopping of more than 94% confidence plus voice and data can be sent via radio at the same time. In this paper, the proposed S/W packet modem is only an implemented S/W component, so when we apply it to aircraft that we don't consider EMC problems with, then we have the advantage of a wider use of conventional UHF/VHF/HF radio that is possible to voice communication. If we recognize these operational requirements, we can apply for a lot of field equipment efficiently.

Isolation of Marine Bacteria Killing Red Tide Microalgae II. Isolation and Algicidal Properties of Pseudomonas sp. LG-2 Possessing Killing Activity for Dinoflagellate, Prorocentrum micans (적조생물 살조세균 탐색 II. 적조생물 Prorocentrum micans 살조세균 Pseudomonas sp. LG-2의 분리와 살조특성)

  • LEE Won-Jae;PARK Young-Tae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.6
    • /
    • pp.852-858
    • /
    • 1998
  • We have isolated a bacterial strain that tends to kill P. micans from the mixed culture of p. minns plus seawater filtrate (poresize, 0.8 $\mu$m) collected at Masan bay in July 1996, in which the mixed culture grown in the f/2 medium. According to the experimental results of the isolated bacterium such as fatty acids analysis, morphological and biochemical characteristic tests, the strain was supposed to be a Pseudomonas and then it was named as Pseudomonas sp. LG-2. The killing effect of Pseudomonas sp. LG-2 against P. micans was proportionally increased with the concentrations of culture filtrate (pore size, 0.8 $\mu$m) is well as with the number of bacterium inoculated. In the mixed culture inoculated with $1.3\times10^6$ cells/ml of Pseudomonas sp. LG-2, the number of P. micans (2,000 cells/ml) was gradually decreased and then killed below 100 cells/ml within 7 days. In addition, the culture filtrate with $30\%$ of final concentration revealed a significant killing effect against P. micans around 3 days after culture. In the relationship between killing effects and growth stage of Pseudomonas sp. LG-2, the culture filtrate at lag phase has little effects on P. micans. In constant, the culture filtrate at mid-log phase showed the killing effect by decreasing P. micans to 112 in number within 5 days. In particular, the culture filtrate at stationary phase showed a significant killing effect against P. micans in which the majority of it was killed after 3 day culture. The species specificity of killing effects of Pseudomonas sp. LG-2 against 5 species of dinoflagellate was only found in P. micans and Scrippsiella trochoidea.

  • PDF

Development of Filtering System ADDAVICHI for Fake Reviews using Big Data Analysis (빅데이터 분석을 활용한 가짜 리뷰 필터링 시스템 ADDAVICHI)

  • Jeong, Davichi;Rho, Young-J.
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2019
  • Recently, consumer distrust has deepened due to blog posts focusing only on public relations due to 'viral marketing'. In addition, marketing projects such as false writing or exaggerated use of the latter phase are one of the most popular programs in 2016 as they are cheaper and more effective than newspaper and TV ads, and the size of advertising costs is set to be a major means of advertising at '3 trillion 394.1 billion won. From this 'viral marketing,' it has become an Internet environment that needs tools to filter information. The fake review filtering application ADDAVICHI presented in this paper extracts, analyzes, and presents blog keywords, total number of searches, reliability and satisfaction when users search for content such as "event" and "taste restaurant." Reliability shows the number of ad posts on a blog, the total number of posts, and satisfaction shows a clean post with confidence divided into positive and negative posts. Finally, the keyword shows a list of the top three words in the review from a positive post. In this way, it helps users interpret information away from advertising.

High Precision Measurement for String Resonator used in FBG Strain Sensors (광섬유 브래그 격자 변형률 센서용 현공진기의 고정밀 측정)

  • 이영균;송인천;정성호;이병하;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.135-139
    • /
    • 2001
  • This paper describes a string resonator that is used for the interrogation system of a Fiber Bragg Grating(FBG) strain sensor. The strain on the fiber piece is calculated from the measured frequency based on that the natural frequency of a string is a function of the applied absolute strain. Existing research considered a fiber as a string, but a fiber is not a string in the strict sense due to its bending stiffness, thus the fiber should be modeled as a beam accompanied with an axial force. In the vibration modeling, the relationship between the strain and the natural frequency is derived, and then the resonance condition is described in terms of both the phase and the mode shape for sustaining resonant motion. Several experiments verify the effectiveness of the proposed model of the fiber. The performance of the string resonator is analyzed by measuring the frequency change according to the applied strains in the dynamic range of 1100$\mu\varepsilon$ referred to the displacement from capacitance sensor. From the experimental results, the implemented string resonator provides the accuracy of $\pm$3$\mu\varepsilon$, the quasi-static resolution of ~0.1$\mu\varepsilon$(rms) which amount to be $\pm$0.17$\mu\textrm{m}$ and ~6nm respectively, in case of fiber length of 56mm. For a dynamic strain, it can provide the accuracy of ~3$\mu\varepsilon$ until the frequency comes to 8Hz. As a consequence, the string resonator proposed for FBG sensor provides the high accuracy and the high resolution in strain measurement, and also it is expecting to be used, for the application, to not only strain but also displacement measuring device.

  • PDF