• 제목/요약/키워드: phase lead

Search Result 846, Processing Time 0.023 seconds

Phase Compensation of Fuzzy Control Systems and Realization of Neuro-fuzzy Compenastors

  • Tanaka, Kazuo;Sano, Manabu
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.845-848
    • /
    • 1993
  • This paper proposes a design method of fuzzy phase-lead compensator and its self-learning by neural network. The main feature of the fuzzy phase-lead compensator is to have parameters for effectively compensating phase characteristics of control systems. An important theorem which is related to phase-lead compensation is derived by introducing concept of frequency characteristics. We propose a design procedure of fuzzy phase-lead compensators for linear controlled objects. Furthermore, we realize a neuro-fuzzy compensator for unknown or nonlinear controlled objects by using Widrow-Hoff learning rule.

  • PDF

The Specficity of Phase Transitions of Lead Monoxide (산화납의 특이상전이)

  • 김정욱;최성철;이응상
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.8
    • /
    • pp.623-628
    • /
    • 1993
  • Lead monoxide has two phases at room temperature. One is a yellow orthorhombic phase, the other is a redtetragonal phase. Sometimes two phases are hybrided. The specificity of phase transitions of lead oxide is found during the milling of the batch including lead oxide. The pure orthorhombic phase of PbO can be transformed to the tetragonal phase perfectly by wet ball milling (milling liquid is distilled water) without thermal energy. However, when ethyl alcohol, isopropyl alcohol and aceton are used as milling liquid, respectively, the hybrid form of orthorhombic andtetragonal phases is obtained by wet ball milling. From the hybrid form heat-treated at $600^{\circ}C$ for 3hrs, this work results that mechanical phase transition of orthorhombic phase make a new form as distorted type orthorhombic phase of PbO.

  • PDF

Stability Criterion of Repetitive Control System Using Phase-Lead and Lag Compensator (진상,지상 보상기를 고려한 반복제어계의 안정성 판별)

  • 서진호;강병철;김상봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.41-45
    • /
    • 1997
  • To design a control system, it is a elementary point that the stability of the system should be guaranteed. Also, the phase of the system plays an important role for its frequence performance. In this paper, we present two stability criterion of repetitive control system with phase-lead and lag compensator. First, the stability criterion for the servo control system with phase-lead and lag compensator is shown by using small-gain theorem. Second, for the repetitive control system with the compensator, the stability criterion, also, is determined by using small-gain theorem. Two stability criterions show the same results that the stability depends on a coefficient of the phase-lead and lag compensator under some condition in servo control system and repetitive control system.

  • PDF

Low Temperature Sintering of PZTN by the Liquid Phase Transient Processing (액상천이공정에 의한 PZTN의 저온소결에 관한 연구)

  • Kim, Chan-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.593-598
    • /
    • 2001
  • Transient liquid phase processing was investigated to decrease processing temperatures while maintaining useful piezoelectric properties in the lead zirconate titanate (PZT) system. Niobium oxide$(Nb_2O_5)$ modified crystalline PZT (PZTN) powder was combined with lead silicate $(PS; PbO-SiO_2)$ glass powder and crystalline titania, zirconia, and niobia. Firing above the melting temperature of the lead silicate $(PS; Tm \risingdotseq\; 714^{\circk}C)$ resulted in liquid phase densification of the PZTN followed by dissolution of the titania, zirconia, and niobia into the liquid phase, and crystallization of additional PZTN. The addition of crystalline titania, zirconia, and niobia to react with the lead oxide from the lead silicate phase resulted in an increase in the dielectric and Piezoelectric properties.

  • PDF

Phase Current Variation of Bifilar-Wound Hybrid Stepping Motor by Lead Angle Control (Lead Angle 제어에 의한 복권형 하이브리드 스테핑 전동기의 상전류 변화에 관한 연구)

  • 우광준;이종언
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.26-34
    • /
    • 1998
  • In this paper, we confirm that the instanteneous phase current of the bifilar-wound hybrid stepping motor is dependent of lead angle by the experimental results. The variation of phase current with lead angle gives informations about the rotor position at the moment when phase winding coil is excited. We show that the rotor position of the bifilar-wound hybrid stepping motor for the closed-loop drives can be detected by using the instantaneous phase current measurement. We propose an instantaneous phase current equation as the function of electrical lead angle by the modeling of the bifilar-wound hybrid stepping motor. We also analyze the relationship between instantaneous phase current and rotor position by the computer simulation results. By the experimental results, we also confirm that the information about the rotor position can be obtained from the instantaneous phase current values at the instance of $\pi/2$ electrical angle of excitation pulse. pulse.

  • PDF

Utility of solid phase extraction for colorimetric determination of lead in waters, vegetables, biological and soil samples

  • Al-Mallah, Zakia;Amin, Alaa S.
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.461-468
    • /
    • 2018
  • A highly sensitive, selective and rapid method for the determination of lead based on the reaction of lead (II) with 5-(4'-chlorophenylazo)-6-hydroxypyrimidine-2,4-dione (CPAHPD) and the solid phase extraction of the Pb(II)-CPAHPD complex with Amberlite XAD-2000 was developed, in the presence of pH 5.6 buffer solution and Triton X-114 medium. CPAHPD reacts with lead to form a violet complex with a molar ratio of 2:1 (CPAHPD to lead). This complex was enriched by the solid phase extraction with Amberlite XAD-2000. An enrichment factor of 500 was obtained by elution of the complex from the resin with a minimal amount of isopentyl alcohol(0.2 mL). In isopentyl alcohol medium,the molar absorptivity of the complex is $1.13{\times}10^6L\;mol^{-1}cm^{-1}$ at 647 nm. Beer's law is obeyed in the range of $5.0-160ng\;mL^{-1}$ in the measured solution. The relative standard deviation for 10 replicate samples of $50ng\;mL^{-1}$ level is 1.26%. The detection and quantification limits reaches 1.5 and $4.7ng\;mL^{-1}$ in the original samples. The presented procedure was successfully applied for determination of lead content in real samples such as vegetables, waters, biological and soil samples with satisfactory results.

Occupational Health Management in the Lead Industry: The Korean Experience

  • Lee, Byung-Kook
    • Safety and Health at Work
    • /
    • v.2 no.2
    • /
    • pp.87-96
    • /
    • 2011
  • In 1967, the problem of occupational lead exposure came to public attention in Korea. Since then, regular progress has been made in lowering workplace lead exposures, instituting new workplace controls, and implementing health examinations of exposed workers. Past serious lead poisoning episodes made it possible to introduce biological monitoring programs on a voluntary basis in high-lead-exposure facilities in Korea. Industry-specific occupational health services for lead workers in Korea during the last 22 years can be categorized into three phases. During the first phase (1988-1993), efforts were directed at increasing awareness among workers about the hazards of lead exposure, biological monitoring of blood zinc protoporphyrin began, and a respiratory protection program was introduced. During the second phase (1994-1997), a computerized health management system for lead workers was developed, blood-lead measurement was added to biologic monitoring, and engineering controls were introduced in the workplace to lower air-lead levels to comply with air-lead regulations. Finally, during the third phase (1998-present), a new biomarker, bone-lead measurement by X-ray fluorescence, was introduced. Bone-lead measurement proved to be useful for assessing body burden and to demonstrate past lead exposure in retired workers. Occupational health service practice for lead workers, including the industry-specific group occupational health system, has brought considerable success in the prevention of lead poisoning and in reducing the lead burden in Korean lead workers during the last several decades. The successful achievement of prevention of lead poisoning in Korea was a result of the combined efforts of lead workers, employers, relevant government agencies, and academic institutes.

The Effect of Relatively Low Lead Contents on the Phase Formation and Jc values of Bi-2223/Ag Tapes

  • Jiang, C.H.;Yoo, J.M.;Ko, J.W.;Kim, H.D.;Chung, H.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.17-20
    • /
    • 2002
  • The effects of relatively low lead content (0.2~0.3) on the 2223 phase formation and transport property of Bi-2223/Ag tapes have been investigated. The results show that lead contents have great impact on the phase assemblage of precursors, subsequently, on the phase formation and transport property of silver sheathed BSCCO-2223 tapes. Powders containing Pb=0.25 and Pb=0.3 resulted in the nearly identical $J_c$ values in fully processed tapes, but leaded to significant difference on the phase formation process. For the case of Pb=0.2, both low conversion fraction of 2212 to 2223 and low $J_c$ value were obtained in final reacted tape, which was probably due to lack of enough liquid phase to facilitate the phase transformation.

  • PDF

A Semi-solid Bonding between Rolled Steel for Structural Parts and Lead Bronze Alloy (구조용 압연강재와 연청동 합금의 반용융 확산접합)

  • 김우열;박홍일;이길근;서원찬
    • Journal of Welding and Joining
    • /
    • v.18 no.1
    • /
    • pp.70-76
    • /
    • 2000
  • A rolled steel for structural parts and lead bronze alloy were bonded each other by a new semi-solid diffusion bonding process to investigate the effect of the process parameters, for example bonding temperature and bonding time, on the interface characteristics, and bonding behavior. It can be possible that manufacture of the bonded steel/lead bronze which has a cylindrical shape with inserted the lead bronze alloy into the steel ring by the diffusion bonding process under the semi-solid condition of the lead bronze alloy without any pressure and flux. It has been know that the control of the amount of the liquid phase in semi-solid lead bronze alloy was very important to obtain soundness interface, since the shear strength of the bonded steel/lead bronze at 850℃ for 60 minutes under the condition of about 40% of the liquid phase in the lead bronze alloy shows maximum value, 210 MPa. The shear strength increases with an increase in bonding time and show maximum value, and then decreases.

  • PDF

Frequency Responses of Ambulatory ECG Systems and Their Correction by a Compensation Circuit

  • Iwao, K.;Yokoi, A.;Suzuki, S.;Goto, T.;Doniwa, K.;Okajima, M.
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 1990
  • Frequency responses of ambulatory electrocardiogram systems were measured. Phase shift was assessed by our improved Wagner's method. The characteristics of the systems were found much worse than that of ordinary ECG equipment both in gain and phase responses. The decay of -3dB in amplitude observed in 0.2Hz and the lead of 45 dog in phase was observed in 0.6Hz. In order to investigate which of these 2 responses play major role in generating false S -T deviation, mathe- matical filters were Composed in a computer and actual ECGs were fed. The false S-T deviation were found to be caused mostly by enormous lead in phase, and then, the compensation circuit to diminish the lead in phase was inserted in the commercial systemes. The compensated systems showed no false deviation in S-T segment.

  • PDF