• Title/Summary/Keyword: phase detection

Search Result 2,138, Processing Time 0.028 seconds

Analysis on the Analog Filter Design and the Effect of Load for BLDCM Sensorless Drive (브러시리스 직류 전동기의 센서리스 구동시 부하 변동에 따른 회전자 위치 오차 분석과 아날로그 필터의 설계)

  • Kim Young-il;Kim Jong-Sun;Jang Jae-Hoon;Yoo Ji-Yoon;Kim Dong-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.660-664
    • /
    • 2004
  • The indirect rotor position detection method using terminal voltage of brushless DC motor (BLDCM) requires simple control circuit, and has wide speed range of sensorless operation. However, because the substantial phase difference exists between real back emf and terminal voltage, the existing indirect detection method using analog filter which is affected by frequency, speed, and load sensitively cannot be synchronized with current, in the end, it advances or delays. This paper presents new analog filter circuit design for rotor position estimation in order to solve the problem, and proposes novel sensorless operation method which is stable even in high speed range and not influenced by parameters with analysis on phase difference by load and speed. Moreover, the appropriateness of the proposed sensorless drive in this paper is verified and analyzed by experimentation.

  • PDF

Measurement and improvement of performance of breast cancer detection system (유방암 검출 시스템 측정 및 성능 개선)

  • Lee, Youn-Ju;Kim, Hyuk-Je;Lee, Jong-Moon;Son, Seong-Ho;Jeon, Soon-Ik
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1091-1092
    • /
    • 2008
  • In this paper, it is described the performance of the breast cancer detection system that is composed of sensing, RF signal and image reconstruction part. Especially in the reconstruction algorithm, the amplitude and the phase of electric fields are used as compare value. So we improved to get the stable values of measured amplitude and phase of electric fields. Through compare images of reconstruction, we confirmed the performance of improved system.

  • PDF

Design of a Clock and Data Recovery Circuit for High-Speed Serial Data Link Application (고속 시리얼 데이터 링크용 클럭 및 데이터 복원회로 설계)

  • 오운택;이흥배;소병춘;황원석;김수원
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1193-1196
    • /
    • 2003
  • This paper proposes a 2x oversampling method with a smart sampling for a clock and data recovery(CDR) circuit in a 2.5Gbps serial data link. In the conventional 2x oversampling method, the "bang-bang" operation of the phase detection produces a systematic jitter in CDR. The smart sampling in phase detection helps the CDR to remove the "bang-bang" operation and to improve the jitter performance. The CDR with the proposed 2x oversampling method is designed using Samsung 0.25${\mu}{\textrm}{m}$ process parameters and verified by simulation. Simulation result shows the proposed 2x oversampling method removes the systematic jitter.e systematic jitter.

  • PDF

Two-Terminal Numerical Algorithm for Single-Phase Arcing Fault Detection and Fault Location Estimation Based on the Spectral Information

  • Kim, Hyun-Houng;Lee, Chan-Joo;Park, Jong-Bae;Shin, Joong-Rin;Jeong, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.460-467
    • /
    • 2008
  • This paper presents a new numerical algorithm for the fault location estimation and arcing fault detection when a single-phase arcing ground fault occurs on a transmission line. The proposed algorithm derived in the spectrum domain is based on the synchronized voltage and current samples measured from the PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm uses DFT(Discrete Fourier Transform) for estimation. The algorithm uses a short data window for real-time transmission line protection. Also, from the calculated arc voltage amplitude, a decision can be made whether the fault is permanent or transient. The proposed algorithm is tested through computer simulation to show its effectiveness.

Sensorless SRM Drive using a Simple Phase Current Detection (간단한 상전류 검출기법에 의한 센서리스 SRM 운전)

  • Kim, Tae-Hyoung;Lee, Dong-Hee;An, Young-Ju;An, Jin-U
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.629-630
    • /
    • 2006
  • This paper describes a novel sensorless excitation position detecting method of Switched Reluctance Motor(SRM) drive. A suitable excitation pattern of each phases is determined by comparison of detecting current without an inductance estimation. The principle of the rotor position estimation is based on the detection of phase current according to rotor position. This sensorless method is very simple and gives efficient control of drive system. The suggested method is verified by experiments.

  • PDF

A Study on Real Time QRS complex Detection Algorithm Using 2-Dimensional Time-Delay Coordinates (시간 지연 2차원 좌표계를 이용한 실시간 QRS 검출에 관한 연구)

  • Jung, Suk-Hyun;Lee, Jeong-Whan;Lee, Byung-Chae;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.277-280
    • /
    • 1995
  • This paper describes a real time QRS detection algorithm. The proposed algorithm detects QRS complex using characteristics of the 2-dimensional phase portrait which is reconstructed from 1-demensional scalar time series. We observe the phase portrait of ECG signal has special trejectory when QRS complex occurs and apply it to detect QRS complexes. In order to evaluate the performance of the proposed algorithm, we use MIT/BIH arrhythmia database. As a result, the proposed algorithm correctly detects 99.3% of the QRS complexes.

  • PDF

Determination of Terbutaline Enantiomers in Human Plasma by Coupled Achiral-Chiral High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Kim, Hyun-Ju;Hong, Seon-Pyo;Shin, Sang-Deok
    • Archives of Pharmacal Research
    • /
    • v.23 no.5
    • /
    • pp.441-445
    • /
    • 2000
  • Achiral-chiral column switching HPLC assay was developed to allow the separation and quantification of the enantiomers of terbutaline in human plasma by means of fluorescence detection. Plasma samples were prepared by solid-phase extraction with sep-pak silica, followed by HPLC assay. The enantiomers of terbutaline and the internal standard were separated from the biological matrix on a silica column, and the two enantiomers were resolved and quantified on a Sumichiral OA-4900 column. The two columns were connected by a switching valve equipped with silica trap column, The trap column was used to concentrate the terbutaline in the eluent from the achiral column before back flushing onto the chiral phase. For each enantiomers, the assay was linear between 2.5-125 ng/$m\ell$ (r=0.9999) and detection limit was 1.0 ng/$m\ell$ .

  • PDF

On-line SPE-HPLC Method using Alumina Filtering to Selectively Extract Phenolic Compounds from Environmental Water

  • Lee, Sung-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3755-3759
    • /
    • 2010
  • A on-line SPE (solid phase extraction)-HPLC preconcentration method was developed for the determination of phenolic compounds at trace levels in environmental water sample. XAD-4 and Dowex 1-X8 were used as sorbent in the on-line SPE-HPLC method for the selective enrichment of nine phenolic compounds, which are included in the priority pollutants list of the US EPA. Also alumina prefiltering considerably reduced the amount of interfering peaks due to humic substances that could accumulated due to the preconcentration step and prevent quantification of polar phenolic compounds in environmental water samples. This method was used to determine the phenolic compounds in tap and river water and superiority to the US EPA 625 method in its enrichment factor, pretreatment time, recoveries, and detection limit. The limits of detection were in the range of $0.3-0.9\;{\mu}g/L$ in tap water sample.

The Anti-islanding Scheme for a Number of Grid-connected Inverters Under Parallel Operation (병렬 연결된 다수 대 계통연계형 인버터를 위한 단독운전 방지 기법)

  • Kim, Dong-Kyune;Cho, Sang-Rae;Choy, Ick;Lee, Young-Kwoon;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.13-22
    • /
    • 2017
  • Anti-islanding scheme of grid-connected inverter is a key function of standards compliance, since unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been researched, however, most of them have problems, which deteriorate performance of islanding detection under parallel-operation. Therefore, this paper proves the reason of problems and proposes a new anti-islanding scheme that has precise islanding detection under parallel-operation in single-phase and three-phase system. Finally, both simulation and experimental result validate the proposed scheme.

Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method (Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer) 개발)

  • Jeong, Jong-Kyou;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1954-1961
    • /
    • 2009
  • This paper describes the development of a three-phase line-interactive dynamic voltage restorer with hybrid detection method, which is composed of three H-bridge inverter modules and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 3kVA prototype. The developed system can compensate the input voltage sag and interruption within 2ms. The maximum allowable duration of voltage interruption is about 4 seconds. The developed system can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication devices, and automation devices, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components, and to be highly reliable in operation.