• Title/Summary/Keyword: phase contrast image

Search Result 127, Processing Time 0.024 seconds

A Study on the Image and Surface Structure analysisthat Manufacture by LB Method of LB Thin Film (LB박막의 이미지와 표면구조분석에 관한 연구)

  • Song, Jin-Won;Lee, Kyung-Sup;Choi, Young-Il;Chung, Hun-Sang;Gu, Hal-Bon;Kim, Young-Keun;Lee, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1618-1620
    • /
    • 2002
  • Transformation of molecular film occurs only usually in air-water interface, 2 dimensions domain's growth and crash are achieved. Organic matter thin film that accumulate molecular film in archaism board only that consist of growth of domain can understand correct special quality of accumulation film supplying information about fine structure and properties of matter of device observing information and so on that is surface forward player and optic enemy using AFM one of SPM application by nano electronics. The stable images are probably due to a strong interaction between the monolayer film and glass substrate. We are unable to obtain molecule resolution in images of the films but did see a marked contrast between images of the bare substrate and those with the network structure film deposited onto it. Formation that prevent when gas phase state and liquid phase state measure but Could know organic matter that molecules form equal and stable film when molecules were not distributed evenly, and accumulated in solid state only.

  • PDF

Segmentation of Bacterial Cells Based on a Hybrid Feature Generation and Deep Learning (하이브리드 피처 생성 및 딥 러닝 기반 박테리아 세포의 세분화)

  • Lim, Seon-Ja;Vununu, Caleb;Kwon, Ki-Ryong;Youn, Sung-Dae
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.8
    • /
    • pp.965-976
    • /
    • 2020
  • We present in this work a segmentation method of E. coli bacterial images generated via phase contrast microscopy using a deep learning based hybrid feature generation. Unlike conventional machine learning methods that use the hand-crafted features, we adopt the denoising autoencoder in order to generate a precise and accurate representation of the pixels. We first construct a hybrid vector that combines original image, difference of Gaussians and image gradients. The created hybrid features are then given to a deep autoencoder that learns the pixels' internal dependencies and the cells' shape and boundary information. The latent representations learned by the autoencoder are used as the inputs of a softmax classification layer and the direct outputs from the classifier represent the coarse segmentation mask. Finally, the classifier's outputs are used as prior information for a graph partitioning based fine segmentation. We demonstrate that the proposed hybrid vector representation manages to preserve the global shape and boundary information of the cells, allowing to retrieve the majority of the cellular patterns without the need of any post-processing.

Cavernous Hemangioma in the Middle Cranial Fossa & Cavernous Sinus

  • Park, Chang-Kyu;Lee, Mou-Seop;Kim, Young-Gyu;Kim, Dong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.4
    • /
    • pp.277-280
    • /
    • 2006
  • Extracerebral cavernous hemangiomas are rare vascular tumors that are very difficult to remove because of severe intraoperative bleeding. We report a case of 57-year-old male with extracerebral cavernous hemangioma with review of 126 cases in the literature. Patient presented with blurred vision, diplopia, numbness on the left side of his face. Magnetic resonance imaging revealed a well defined mass of $3{\times}4{\times}3cm$ size with heterogenous iso-or hypointensity on T1-weighted image showing strong homogenous contrast enhancement and marked hyperintensity on T2-weighted image. Digital subtraction angiography[DSA] revealed a faint tumor blush by feeders from the left internal carotid artery[ICA] and left external carotid artery[ECA] in the delayed phase. Even with profuse intratumoral bleeding, near total removal was achieved. In addition to preoperative neurologic deficits such as ophthalmoplegia, facial numbness in the V1-2 dermatomes, ptosis appeared postoperatively.

LED Backlight Driving Circuits and Dimming Method

  • Kwon, Oh-Kyong;Jung, Young-Ho;Lee, Yong-Hak;Cho, Hyun-Suk;Nam, Ki-Soo;In, Hai-Jung
    • Journal of Information Display
    • /
    • v.11 no.4
    • /
    • pp.173-181
    • /
    • 2010
  • In this paper, light-emitting-diode (LED) backlight driving circuits and dimming method for medium-sized and large liquid crystal displays (LCDs) are proposed. The double loop control method, the intelligent-phase-shifted PWM dimming method, the fast-switching current regulator, and the current matching techniques are proposed to improve not only the current regulation characteristics and the power efficiency but also the current matching characteristics and the transient response of the LED current. The brightness of the backlight using the proposed local dimming method was determined from the histogram of the local block to reduce the power consumption of the backlight without image distortion. The measured maximum power efficiency of the LED backlight driving circuit for medium-sized LCDs was 90%, and the simulation results showed an 88% maximum power efficiency of the LED backlight driving circuit for large LCDs. The maximum backlight power-saving ratio of the proposed dimming method was 41.7% in the simulation with a high-contrast image. The experiment and simulation results showed that the performance of LEDs as LCD backlight units (BLUs) improved with the proposed circuits and method.

Ultrasonic Images Enhancement of the SS Reference Specimen and the Reference Calibration Block for NPPs by the Combining Bases of Support for Spatial Frequency (공간주파수대역에서 기저대역 확장을 통한 원전 대비시험편과 대비 보정 시험편의 초음파 영상 개선)

  • Park, Chi-Seung;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.13 no.10
    • /
    • pp.651-657
    • /
    • 2003
  • Ultrasonic microscope has been used to detect the defects on surface or inner solid. Conventionally, it has used at a single operating frequency. The resolution and quality of the measured images are determined by a characteristic of the transducer of the ultrasonic microscope. The conventional ultrasonic microscope has been used envelope detector to detect the amplitude of reflected signal, but the changes in amplitude is not sensitive enough for specimen with microstructure that in phase. In this paper, we have studied multi-frequency depth resolution enhancement with ultrasonic reflection microscope for the reflectors of a stainless steel reference specimen and a reference calibration block to be used as the material in nuclear power plants for ISI, PSI. Increased depth resolution can be obtained by taking two, three-dimensional images at more that one frequency and numerically combining the results. As results of the experiment, we could get enhanced images with the rate of contrast in proportion and high quality signal distribution for the image to the changing rate of depth for the reflectors of the two kinds of specimens.

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP (최대강도투사를 이용한 관찰 위치와 거리에 최적화 된 입체 자기공명 뇌 혈관영상 재구성)

  • Shin, Seok-Hyun;Hwang, Do-Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2012
  • Purpose : We studied enhanced method to view the vessels in the brain using Magnetic Resonance Angiography (MRA). Noticing that Maximum Intensity Projection (MIP) image is often used to evaluate the arteries of the neck and brain, we propose a new method for view brain vessels to stereo image in 3D space with more superior and more correct compared with conventional method. Materials and Methods: We use 3T Siemens Tim Trio MRI scanner with 4 channel head coil and get a 3D MRA brain data by fixing volunteers head and radiating Phase Contrast pulse sequence. MRA brain data is 3D rotated according to the view angle of each eyes. Optimal view angle (projection angle) is determined by the distance between eye and center of the data. Newly acquired MRA data are projected along with the projection line and display only the highest values. Each left and right view MIP image is integrated through anaglyph imaging method and optimal stereoscopic MIP image is acquired. Results: Result image shows that proposed method let enable to view MIP image at any direction of MRA data that is impossible to the conventional method. Moreover, considering disparity and distance from viewer to center of MRA data at spherical coordinates, we can get more realistic stereo image. In conclusion, we can get optimal stereoscopic images according to the position that viewers want to see and distance between viewer and MRA data. Conclusion: Proposed method overcome problems of conventional method that shows only specific projected image (z-axis projection) and give optimal depth information by converting mono MIP image to stereoscopic image considering viewers position. And can display any view of MRA data at spherical coordinates. If the optimization algorithm and parallel processing is applied, it may give useful medical information for diagnosis and treatment planning in real-time.

Characteristics of Synthesized Red Cells Using Bovine Hemoglobin as Oxygen Carrier

  • Cho, Eng-Haeng;Hah, Jong-Sik;Kim, Ku-Ja
    • The Korean Journal of Physiology
    • /
    • v.26 no.1
    • /
    • pp.37-44
    • /
    • 1992
  • The encapsulation of the Purified bovine hemoglobin with Phospholipids obtained from egg folk was performed using a rotary vacuum evaporator. The prepared Hb-containing liposome (hemosome) had good properties as artificial red blood cell. The shape and size of the hemosomes were measured by a phase contrast microscope and image analyzer. The function of the hemosome as oxygen carrier was tested by measuring oxygen saturation curve with blood gas analyzer and infusing it into rats. The prepared hemosome was 1.184 + 0.423 ${\mu}m$ in diameter and round in shape. $P_{50}$ value of the hemosome solution was 28 mmHg. The synthesized red cells seem to function as oxygen carrier, because the severely bled rats were prolonged in their life by transfusion of the hemosome solution containing bovine hemoglobin.

  • PDF

A Study on measurement blood velocity according to variable changing in magnetic resonance phase contrast image (자기공명 위상대조도 기법에서 병렬영상기법 변화에 따른 혈류정량 측정에 관한 연구)

  • Cho, yong-bum;Yang, seon-wook;Son, soon-yong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.107-108
    • /
    • 2017
  • 3차원 위상대조도 기법의 단점인 긴 검사시간으로 인해 임상적 유용성이 떨어진다. 본 논문은 시간매개변수인 병렬영상기법(Grappa) 변경에 따른 혈류정보의 정량적 평가를 통해 차이점을 알아보고 임상적 활용정도를 평가하였다. 자체 제작한 혈류팬텀을 통해 실험하였으며, Grappa을 5번 변경하여 실험하였다. 연구결과, Grappa를 적용하지 않았을 경우 혈류속도는 평균 9.42로 총 4단계를 적용한 혈류속도 차이율은 각각(1.4, 1.5, 0.4, 1.5%)이었으며 flow와 WSS도 각각(1.4, 1.6, 0.8, 25%), (2.1, 1.4, 1.1, 0.8%)이었다. 통계적으로도 유의하지 않아 Grappa를 적용하지 않은 검사법과 혈류정보가 동일하였다.(P>0.05) 긴 검사 시간으로 인해 임상적 활용이 떨어지는 짧은 검사시간을 요하는 소아환자나 중등도 환자 또는 폐쇄공포증 환자에게 시간을 단축한 3차원 위상대조도 기법을 사용하여 단점을 보완한다면 임상적 활용가치가 높아질 것이라 사료된다.

  • PDF