• Title/Summary/Keyword: personal monitoring

Search Result 489, Processing Time 0.041 seconds

Personal Dosimeters Worn by Radiation Workers in Korea: Actual Condition and Consideration of Their Proper Application for Radiation Protection

  • Eunbi Noh;Dalnim Lee;Sunhoo Park;Songwon Seo
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.162-166
    • /
    • 2023
  • Background: Assessment of the radiation doses to which workers are exposed can differ depending on the placement of dosimeters on the body. In addition, it is affected by whether the placement is under or over a shielding apron. This study aimed to evaluate the actual positioning of personal dosimeters on the body, with or without shielding aprons, among radiation workers in Korea. Materials and Methods: We analyzed the survey data, which included demographic characteristics, such as sex, age, occupation, work history, and placement of the personal dosimeter being worn, from a cohort study of Korean radiation workers. We assessed the use of personal dosimeters among workers, stratified by sex, age, working period, starting year of work, and occupation. Results and Discussion: Overall, high compliance (89.1% to 99.0%) with the wearing of dosimeters on the chest was observed regardless of workers' characteristics, such as age, sex, occupation, and work history. However, the placement of dosimeters, either under or over the shielding aprons, was inconsistent. Overall, 40.1% of workers wore dosimeters under their aprons, while the others wore dosimeters over their aprons. This inconsistency indicates that radiation doses are possibly measured differently under the same exposure conditions solely owing to variations in the placement of worn dosimeters. Conclusion: Although a lack of uniformity in dosimeter placement when wearing a shielding apron may not cause serious harm in radiation dose management for workers, the development of detailed guidelines for dosimeter placement may improve the accuracy of dose assessment.

Factors Influencing Compliance on the Use of Personal Protective Equipment during Cleaning of Medical Device Reprocessing Staffs (의료기기 재처리 세척 직원의 개인보호구 착용 이행의 영향요인)

  • Park, Hyun Hee;Hong, Jung Hwa;Jeong, Gye Seon;Lee, Kwang Ok
    • Journal of muscle and joint health
    • /
    • v.31 no.1
    • /
    • pp.42-52
    • /
    • 2024
  • Purpose: This study aimed to identify the factors affecting compliance with personal protective equipment (PPE) use among medical device reprocessing staff. Methods: This descriptive cross-sectional study included 163 cleaning staff members from ten general hospitals in Seoul and Gyeonggi. Data were collected using self-report questionnaires administered between July and September 2023. Analysis included t-tests, ANOVA, Pearson's correlation coefficient, Bonferroni correction, and multiple regression, conducted using SAS ver.9.4. Results: Statistically significant differences in compliance with PPE were found based on department and exposure to contamination within six months (t=-2.82, p=.007). Attitudes toward PPE (r=.22, p=.006) and awareness of the safety climate (r=.22, p=.006) showed a statistically significant positive correlation with PPE compliance. Factors influencing use of personal protective equipment by cleaning staff during medical device reprocessing were department, compliance with PPE, and awareness of the safety climate. The explanatory power of these factors was 58.0%. Conclusion: Improving PPE compliance and creating a safe cleaning environment entails fostering a supportive safety climate. Additionally, regular training that takes into consideration the characteristics of the cleaning staff, alongside continuous monitoring, is required.

Ubiquitous-Based Mobile Control and Monitoring of CNC Machines for Development of u-Machine

  • Kim Dong-Hoon;Song Jun-Yeob
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.455-466
    • /
    • 2006
  • This study was an attempt to control and monitor Computerized Numerical Controller (CNC) machines anywhere and anytime for the development of a ubiquitous machine (u-machine). With a Personal Digital Assistant (PDA) phone, the machine status and machining data of CNC machines can be monitored in wired and wireless environments, including the environments of IMT2000 and Wireless LAN. Moreover, CNC machines can be controlled anywhere and anytime. The concept of the anywhere-anytime controlling and monitoring of a manufacturing system was implemented in this study for the purpose of u-manufacturing and u-machines. In this concept, the communication between the CNC controller and the PDA phone was successfully performed anywhere and anytime for the real-time monitoring and control of CNC machines. In addition, the interface between the CNC controller and the developed application module was implemented by Object linking and embedding for Process Control (OPC) and shared CNC memory. For communication, the design of a server contents module within the target CNC was based on a TCP/IP. Furthermore, the client contents module within the PDA phone was designed with the aid of embedded c++ programming for mobile communication. For the interface, the monitoring data, such as the machine status, the machine running state, the name of the Numerical Control (NC) program, the alarm and the position of the stage axes, were acquired in real time from real machines with the aid of the OPC method and by sharing the CNC memory. The control data, such as the start, hold, emergency stop, reserved start and reserved stop, were also applied to the CNC domain of the real machine. CNC machines can therefore be controlled and monitored in real time, anywhere and anytime. Moreover, prompt notification from CNC machines to mobile phones, including cellular phones and PDA phones, can be automatically realized in emergencies.

A Case Study on Smart Plant and Monitoring System Implementation of Venture Company for Auto Parts (자동차부품 벤처기업 스마트공장 및 모니터링 시스템 구현 사례연구)

  • Han, Jae Hun;Lee, Deok Soo;Park, Roh Gook
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.12 no.5
    • /
    • pp.29-37
    • /
    • 2017
  • In this study, real-time monitoring is carried out in the factory site for product quality control such as improvement of productivity through facility automation, improvement of product quality, improvement of factory environment, check of facility maintenance status and check of product defect, And to establish a smart factory for the purpose of protecting the personal environment of the worker. The company is an auto parts company located in the province. The main research content is development of automation and monitoring system of oil filter clipping necessary for smart factory. Smart factory oil filter clipping automation is divided into electric air parts, solenoid valve and other parts processing process. Smart factory quality inspection monitoring system is implemented by server PC and S / W, client software, Operator PC, operating program, and input terminal application. This research data is expected to be very useful data for the auto parts venture companies that are promoting smart factories.

  • PDF

Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography (Computed Tomographic Angiography (CTA)의 검사 시 조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Jung, Jae-Yong;Yun, Jung-Soo;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.59-69
    • /
    • 2016
  • The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast-enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was $716.53mGy{\cdot}cm$ and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

A Case Study on the Application of Security Policy for Outsourcing Personnel in case of Large-Scale Financial IT Projects (금융회사 대형 IT프로젝트 추진 시 외주직원에 대한 보안정책 적용 사례 연구)

  • Son, Byoung-jun;Kim, In-seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.4
    • /
    • pp.193-201
    • /
    • 2017
  • Financial firms strengthen to protect personal information from the leakage, introducing various security solutions such as print output security, internet network Isolation system, isolationg strorage of customer information, encrypting personal information, personal information detecting system, data loss prevention, personal information monitoring system, and so on. Financial companies are also entering the era of cutthroat competition due to accept of the new channels and the paradigm shift of financial instruments. Accordingly, The needs for security for customer information held by financial firms are keep growing. The large security accidents from the three card companies on January 2014 were happened, the case in which one of the outsourcing personnel seized customer personal information from the system of the thress card companies and sold them illegally to a loan publisher and lender. Three years after the large security accidents had been passed, nevertheless the security threat of the IT outsourcing workforce still exists. The governments including the regulatory agency realted to the financail firms are conducting a review efforts to prevent the leakage of personal information as well as strengthening the extent of the sanction. Through the analysis on the application of security policy for outsourcing personnel in case of large-scale Financial IT projects and the case study of appropriate security policies for security compliance, the theis is proposing a solution for both successfully completing large-scale financial IT Project and so far as possible minizing the risk from the security accidents by the outsouring personnel.

Object-oriented Design for Water Quality Monitoring Networks in the Han River System (한강수계 수질측정망 개선을 위한 목적 지향 설계 방안에 관한 연구)

  • Wang, Soo-Kyun;Na, Eun-Hye;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.453-460
    • /
    • 2005
  • Since late 1970s, water quality monitoring had been performed in Korea by various agencies according to their own needs and objectives. Lacking of consistency in principles, such diverse operation has been producing difficulties in management of information on water quality parameters. These difficulties resulted from the fact that the expansion of monitoring networks had been based not on systematic methodology with considerations on scientifically established planning objectives but on personal experiences and subjective judgments in locating monitoring stations. This study aimed, therefore, to develop a selection methodology for locating monitoring stations to provide various informations on water quality to satisfy various monitoring objectives such as understanding short and long term trends of water quality, monitoring violations to water quality standards, identifying external causes and sources affecting water quality changes, supporting utilization of water resources, examining short-term variations in water quality through a concentrated investigation, estimating pollution loads from each unit watershed, supporting water quality modeling, and establishing informative systems for water resources management. Also, we applied the proposed methodology and presented an improved expansion plan for water quality monitoring networks in the Han River.

Emergency Support System using Smart Device (스마트 기기를 활용한 응급 지원 시스템)

  • Jeong, Pil-seong;Cho, Yang-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.9
    • /
    • pp.1791-1798
    • /
    • 2016
  • Recently, research about ESS(Emergency Support System) has been actively carried out to provide a variety of medical services using smart devices and wearable devices. Smart healthcare provides a personalized health care service using various types of bio-signal measuring sensors and smart devices. For the smart healthcare using a smart device, it is need to research about personal health monitoring using a smart wearable devices, and also need to research on service methods for first aid measures after an emergency. In this paper, we proposed about group management based emergency support system, that is monitoring about personal bio signal using smart devices and wearable devices to protect patient's life. The system notices to the medical volunteers based on the position information when an emergency situation. In addition, we have designed and implemented an emergency support system providing the information of the patient on the display when transmitting a picture of a patient using a smart device to the server.

Design and Implementation of Network Self-Configuration Based on Bluetooth (Bluetooth 기반 네트워크 자동형성 설계 및 구현)

  • Kang, Seong-Ho;Choo, Young-Yeol
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.10
    • /
    • pp.1376-1384
    • /
    • 2008
  • Numerous researches on network self-configuration have been conducted on Wireless Sensor Network (WSN) and Ad Hoc network but the results have not been applied yet for factory automation. This paper presents development of intelligent process management systems conducting process monitoring and control irrelevant to physical position of a plant operator. The systems are indispensable for diagnosis of rotating machines which cannot exploit wired network. The system was implemented in a Personal Digital Assistant (PDA) using Bluetooth communication protocol. When a mobile terminal reaches to communication range of the process management server, the server detects the mobile terminal to reconfigure plant network automatically. The server authenticates a user of the terminal to download and installs monitoring and control program considering authorized level of the user. If the terminal leaves communication range of the server, it deletes the node from the network and removes the program automatically to save resources and prevent security problems such as missing terminal. Operation of developed functions was verified in a testbed emulating steel-making plant.

  • PDF

A Study of Computerized Industrial Hygiene Control System (작업환경관리 전산화에 관한 연구)

  • Lee, Song Kwon;Lee, Young Sei;Kim, Young Su;Kim, Yong Lae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.117-126
    • /
    • 1994
  • Some of the important and vital roles performed by the Health Care Center of Pohang Iron & Steel Co., Ltd.(POSCO) are the periodic monitoring of the work sites as well as regular medical check-ups for each workers to ensure both pleasant and safe working conditions and to protect employees' health. Pohang Steel Works, which has 42 plants, 26 facilities and 12,000 employees, has an annual crude steel production capacity of 9,670,000 using 24,500,000 ton of raw materials. We have measured lots of areal and personal working environment according to Occupational Safety and Health Law semiannually. All data collected on industrial hygiene is stored and managed by personal computer. The developed of a computerized industrial hygiene control system linked to the company's main computer system will provide efficient evaluation of the working environment as well as critical informations on employees' health. Development of this system had begun in May, 1992 and was completed in March, 1994. The computerized industrial hygiene control system can; 1. store industrial hygiene data, providing key pertinent to the diagnosis of occupational related illnesses, and if necessary, the basis for improving the working environment, 2. decide type and time of medical examination of each work for exposure to specific agents, and supply proper protection periodically, 3. prevent occupational related illnesses through evaluation of environmental and biological monitoring, and performance of epidemiological surveillance, 4. facilitate proper job placement through linking of industrial hygiene control and personnel information systems, 5. monitor job processes. levels of chemical agents used, and new agents introduced, 6. and increase productivity by saving time resulting from the implementation of the computerized sysyte,

  • PDF