• Title/Summary/Keyword: personal monitoring

Search Result 489, Processing Time 0.027 seconds

An Integrated Air Monitoring Approach for Assessment of Formaldehyde in the Workplace

  • Dugheri, Stefano;Bonari, Alessandro;Pompilio, Ilenia;Colpo, Marco;Mucci, Nicola;Arcangeli, Giulio
    • Safety and Health at Work
    • /
    • v.9 no.4
    • /
    • pp.479-485
    • /
    • 2018
  • The aim of this study is to validate an integrated air monitoring approach for assessing airborne formaldehyde (FA) in the workplace. An active sampling by silica gel impregnated with 2,4-dinitrophenylhydrazine, a passive solid phase microextraction technique using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine as on-fiber derivatization reagent, an electrochemical direct-reading monitor, and an enzyme-based badge were evaluated and tested over a range of 0.020-5.12 ppm, using dynamically generated FA air concentrations. Simple linear regression analysis showed the four methods were suitable for evaluating airborne FA. Personal and area samplings in 12 anatomy pathology departments showed that the international occupational exposure limits in the GESTIS database were frequently exceeded. This monitoring approach would allow a fast, easy-to-use, and economical evaluation of both current work practices and eventual changes made to reduce FA vapor concentrations.

Development of an Early Diagnostic Device for African Swine Fever through Real-time Temperature Monitoring Ear-tags (RTMEs)

  • Taehyeun Kim;Minjong Hong;JungHwal Shin
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.275-279
    • /
    • 2023
  • Throughout the 20th century, the transition of pig farms from extensive to intensive commercial operations amplified the risk of disease transmission, particularly involving African swine fever (ASF). Real-time temperature monitoring systems have emerged as essential tools for early ASF diagnosis. In this paper, we introduce new real-time temperature monitoring ear tags (RTMEs) modeled after existing ear tag designs. Our crafted Pig-Temp platforms have three primary advantages. First, they can be effortlessly attached to pig ears, ensuring superior compatibility. Second, they enable real-time temperature detection, and the data can be displayed on a personal computer or smartphone application. Furthermore, they demonstrate excellent measurement accuracy, ranging from 98.9% to 99.8% at temperatures between 2.2 and 360℃. A linear regression approach enables fever symptoms associated with ASF to be identified within 3 min using RTMEs. The communication range extends to approximately 12 m (452 m2), enabling measurements from an estimated 75 to 2,260 pigs per gateway. These newly developed Pig-Temp platforms offer singifcant enhancement of early ASF detection.

Status of Sanitary Education and Recognition and Perceived Performance of Cooking Operations Related to Sanitation for Cooks in a Super Deluxe Hotel (특1급 호텔 조리사의 위생교육 현황과 위생관련 조리업무 인지 및 직무수행도)

  • Jang, Myung-Ha;Kang, Kun-Og
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.5
    • /
    • pp.746-755
    • /
    • 2011
  • A survey on the status of sanitary education and recognition and perceived performance of cooking operations related to sanitation for cooks at nine deluxe hotels in the Seoul area was conducted. The frequency of a food sanitary training program inside the hotel was 94.0%, and the frequency of training was 'once a month' at 68.5%. The program was taught by a hygienist in the hotel (62.7%), and 64.2% of cooks always attended. Cooks' recognition of HACCP was 3.52, and the importance of education on HACCP was higher at 3.77. Cook's' level of sanitary management was satisfactory with an average of 3.83 out of 5 in a Likert scale. The results showed a high average (4.08) for importance of personal hygiene during cooking, but satisfaction of personal hygiene was rather low at 3.92. Cooks' recognition of food sanitation in work field was very high at 4.15. The average scale of recognition on personal hygiene was 4.36, and out of 10 items related to personal hygiene, 'maintaining hand hygiene' showed the highest recognition (4.43). In a performance scale, the average was 4.24, and 'performing annual health examination' was the highest at 4.38. Perceived recognition of 18 items related to food sanitation had an average of 4.41, whereas the average for performance was lower at 4.31. Perceived recognition of 12 items related to cooking equipments had an average of 4.39, and average scale of performance was 4.28. Therefore, cooks' high recognition of food sanitation but rather low recognition of satisfaction of personal hygiene and perceived performance indicated that systematic sanitation management monitoring tools are necessary for higher performance.

A study to detect and leaked personal information on the smartphone. (스마트폰 상에서의 개인정보 유출 탐지 모니터링 연구)

  • Kim, Wung-Jun;Park, Sang-Hwi;Park, Sang-No;Kim, Chang-Su;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.606-608
    • /
    • 2014
  • Recent smartphone users constantly increases, an increase in malicious applications smartphones indiscretions exists within the Terminal, through the deployment of privacy disclosure, Singh and other victims also are on the rise. A typical personal way to malicious code masquerading as a normal application and install it on the handset of my text message or a personal note, such as personal information, the certificate directory, is the way that leaked. Therefore, to obtain permission to attack the root Terminal event by collecting malware infections and respond to determine whether it is necessary for the technique. In this paper, check the features of a Smartphone in real time systems, to carry out a study on the application throughout the Terminal to collect my attack event analysis, malware infection can determine whether or not the mobile security monitoring system. This prevents a user's personal information and take advantage of the top and spill are expected to be on the field.

  • PDF

Development of personal health management data server platform based on health care data (헬스케어 데이터 기반의 개인 건강관리 데이터 서버 플랫폼 개발)

  • Park, Doyoung;Song, Hojun
    • Journal of Platform Technology
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 2022
  • The emergence of new diseases such as the Covid 19 pandemic that occurs in the 21st century and the occurrence of health abnormalities according to the busy daily life of modern people are increasing. Accordingly, the importance of health care management and data-based health management is being highlighted, and in particular, interest in personal health management data based on personal health care data of patients is rapidly increasing. In this study, to solve the difficult problems of personal health management, we developed a personal health care platform incorporating IT for self-diagnosis and solution and developed an application that measures bio-signals generated in the human body and transmits them to the platform. A health management system was established. Through this, not only the health care of modern people, but also the psychological and emotional care support needs through psychological and emotional monitoring of the developmentally disabled and the vulnerable who have difficulty in expressing their opinions are to be addressed. In addition, the overall health and living environment data of the individual was integrated to develop an optimized medical and health management service for the individual.

Financial violations by messenger hacking (Internet banking) Attack Analysis (메신저 해킹을 통한 금융침해(인터넷뱅킹) 공격 분석)

  • Roo, Kyong-Ha;Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.451-455
    • /
    • 2012
  • In this paper, Nateon, MSN Messenger, including how to hack into the most intimate acquaintance formed as follows, for hacking (keyloggers, remote monitoring, etc.) by sending a bank and ID, PW, certificate, security card, etc. personal financial information obtained after the withdrawal of the account balance to have a personal financial analysis infringement attack vulnerable elements found in internet banking, the vulnerabilities and countermeasures concerning the prevention of accidents, including violations by seeking a more secure Internet banking personal Internet Banking is to devise a deal.

  • PDF

Implementation of GPS Based Location Management System (GPS를 이용한 위치관리시스템 구현)

  • Choi, Jae-Myeong;Kang, Heau-Jo;Lee, Sang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • In this paper, person monitoring and personal identification information management by using the location positioning device and the location management system based on GPS is analysed and developed. Mobile HTE(Mobile HTE : Mobile Home Terminal Equipment) of the developed system uses the module for transmitting PID(Personal Identification Device) information and the module based on GPS's location information. HTE transmits the received information from Mobile HTE to the Location Management System through the internet system. The Location Management System is developed for person location management and information management.

  • PDF

A Study on The Personal Wallet Management System Using Beacon Signal Processing (비콘 신호 처리를 활용한 개인소지품 지갑 관리 시스템에 대한 연구)

  • Kim, Dong-Ik;Nam, Kang-Hyun;Lee, Hyeon-Yeong;Ahn, Tae-Uk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1109-1116
    • /
    • 2018
  • The purpose of this study is to solve the loss of personal belongings by utilizing monitoring function of IoT platform. The beacon to combined with personal belongings are registered with the application server, the trigger processing function according to the occurrence of the lost event is performed intelligently through the device, the app, the IoT network, and the application server.

A Sensor Identification Scheme for Dynamic Interworking Between Personal Sensor Devices and a Smartphone (개인용 센서 기기와 스마트폰의 동적 연동을 위한 센서 식별 기법)

  • Min, Hong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.2
    • /
    • pp.27-32
    • /
    • 2016
  • Several sensor devices have been developed for monitoring individual's health and status information and services which visualize customized information by associating applications running on smartphones with sensor devices also have been emerged. Though these applications provide similar information to a user, each sensor device has its own application caused by non-standardized packet formats. In this paper, we propose a sensor device identification for dynamic interworking between a smartphone and personal sensor devices. In the proposed scheme, we can use the same application which plays role of a client on the smartphone as changing sensor devices because server stores packet information of sensor devices.

Development of Plantar Pressure Measurement System and Personal Classification Study based on Plantar Pressure Image

  • Ho, Jong Gab;Kim, Dae Gyeom;Kim, Young;Jang, Seung-wan;Min, Se Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.11
    • /
    • pp.3875-3891
    • /
    • 2021
  • In this study, a Velostat pressure sensor was manufactured to develop a plantar pressure measurement system and a C#-based application was developed to monitor and collect plantar pressure data in real time. In order to evaluate the characteristics of the proposed plantar pressure measurement system, the accuracy of plantar pressure index and personal classification was verified by comparing with MatScan, a commercial plantar pressure measurement system. As a result, the output characteristics according to the weight of the Velostat pressure sensor were evaluated and a trend line with the reliability of r2 = 0.98 was detected. The Root Mean Square Error(RMSE) of the weighted area was 11.315 cm2, the RMSE of the x coordinate of Center of Pressure(CoPx) was 1.036 cm and the RMSE of the y coordinate of Center of Pressure(CoPy) was 0.936 cm. Finally, inaccuracy of personal classification, the proposed system was 99.47% and MatScan was 96.86%. Based on the advantage of being simple to implement and capable of manufacturing at low cost, it is considered that it can be applied to various fields of measuring vital signs such as sitting posture and breathing in addition to the plantar pressure measurement system.