• Title/Summary/Keyword: personal health devices

Search Result 131, Processing Time 0.025 seconds

Privacy-Preserving IoT Data Collection in Fog-Cloud Computing Environment

  • Lim, Jong-Hyun;Kim, Jong Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.9
    • /
    • pp.43-49
    • /
    • 2019
  • Today, with the development of the internet of things, wearable devices related to personal health care have become widespread. Various global information and communication technology companies are developing various wearable health devices, which can collect personal health information such as heart rate, steps, and calories, using sensors built into the device. However, since individual health data includes sensitive information, the collection of irrelevant health data can lead to personal privacy issue. Therefore, there is a growing need to develop technology for collecting sensitive health data from wearable health devices, while preserving privacy. In recent years, local differential privacy (LDP), which enables sensitive data collection while preserving privacy, has attracted much attention. In this paper, we develop a technology for collecting vast amount of health data from a smartwatch device, which is one of popular wearable health devices, using local difference privacy. Experiment results with real data show that the proposed method is able to effectively collect sensitive health data from smartwatch users, while preserving privacy.

A study on the attitude affecting the preventive behavior for hearing conservation (청력보존을 위한 예방 행위에 영향을 미치는 태도 분석)

  • Rhee, Kyung-Yong;Yi, Kwan-Hyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.2 s.53
    • /
    • pp.371-384
    • /
    • 1996
  • The purpose of this study is to investigate attitude factor related to hearing conservation and to find attitude affecting the preventive behavior for hearing conservation. The research method used in this study was self-administered questionnaire. Samples of the study were composed of 353 workers exposed noise selected randomly in 10 ship-building manufacturing companies. Authors extracted following 9 factors related hearing conservation from 26 attitude propositions prepared from previous study results and health belief model; (1) general perceived susceptibility, (2) relative perceived susceptibility compared with colleagues, (3) concern to the personal protective devices, (4) perceived severity and concern to the hearing capacity, (5) concern to the hearing and noise assessment, (6) concern to the control noise and hearing conservation, (7) group pressure and reason of wearing protective devices, (8) apathy of hearing loss from noise, (9) knowledge about hearing conservation. Attitude factors affecting the preventive health behavior were general perceived susceptibility, concern to the noise control and hearing conservation, and concern to the personal protective devices in the case of wearing personal protective devices. But in the case of avoiding noise exposure as preventive health behavior, perceived severity and concern to the hearing capacity was a significant attitude factor with knowledge about hearing conservation.

  • PDF

A Study on Home Healthcare Convergence for IEEE 11073 Standard (IEEE 11073 표준을 위한 홈 헬스케어 융합에 대한 연구)

  • Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.422-427
    • /
    • 2015
  • Medical paradigm shift has been based on disease treatment into wellness care so that changes need more IT-based smart medical services. In addition, individual based smart devices are more focused on healthcare services and can provide access to personal medical information, health conditions and social welfare managed by users. In this paper, IEEE11073 PHD (Personal Health Devices) and HL7 (Health Level 7) standards of legacy healthcare devices are developed for communicating with each individual based smart device and providing healthcare service in smart TV environment through a unified home healthcare gateway.

Use of Portable Global Positioning System (GPS) Devices in Exposure Analysis for Time-location Measurement

  • Lee, Ki-Young;Kim, Joung-Yoon;Putti, Kiran;Bennett, Deborah H.;Cassady, Diana;Hertz-Picciotto, Irva
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.461-467
    • /
    • 2009
  • Exposure analysis is a critical component of determining the health impact of pollutants. Global positioning systems (GPS) could be useful in developing time-location information for use in exposure analysis. This study compares four low cost GPS receivers with data logging capability (Garmin 60, Garmin Forerunner 201, GeoStats GeoLogger and Skytrx minitracker MT4100) in terms of accuracy, precision, and ease of use. The accuracy of the devices was determined at two known National Geodetic Survey points. The coordinates logged by the devices were compared when the devices were carried while walking and driving. The Garmin 60 showed better accuracy and precision than the GeoLogger when they were placed at the geodetic points. The Forerunner and Skytrx did not record when they were kept stationary. When the subject wore the devices while walking, the location of the devices differed by about 8 m on average between any two device combinations involving the four devices. The distance between the coordinates logged by the devices decreased when the devices were carried with their antennas facing the sky. All the devices showed similar routes when they were used in a car. All the devices except the Forerunner had satisfactory signal reception when they were worn and when they were carried in the car. The GeoLogger is less comfortable for the subject because of specific wearing requirements. This evaluation found that the Garmin 60 and the Skytrx may be useful in personal exposure analysis studies to record time-location data.

Skin-interfaced Wearable Biosensors: A Mini-Review

  • Kim, Taehwan;Park, Inkyu
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.71-78
    • /
    • 2022
  • Wearable devices have the potential to revolutionize future medical diagnostics and personal healthcare. The integration of biosensors into scalable form factors allow continuous and noninvasive monitoring of key biomarkers and various physiological indicators. However, conventional wearable devices have critical limitations owing to their rigid and obtrusive interfaces. Recent developments in functional biocompatible materials, micro/nanofabrication methods, multimodal sensor mechanisms, and device integration technologies have provided the foundation for novel skin-interfaced bioelectronics for advanced and user-friendly wearable devices. Nonetheless, it is a great challenge to satisfy a wide range of design parameters in fabricating an authentic skin-interfaced device while maintaining its edge over conventional devices. This review highlights recent advances in skin-compatible materials, biosensor performance, and energy-harvesting methods that shed light on the future of wearable devices for digital health and personalized medicine.

Development of an Ubiquitous Healthcare System based on Health Information Exchange Standards (건강정보 교환 표준에 기반한 유비쿼터스 헬스케어 시스템 개발)

  • Lee, In-Keun;Kim, Hwa-Sun;Cho, Hune
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.273-280
    • /
    • 2012
  • As changed the clinical environment, the interest on u-Healthcare service and systems has been increased. The ubiquitous healthcare(u-Healthcare) systems are constructed at the integrated environment that consists of various devices and systems basically such as personal health devices(PHDs) measuring body signals, information aggregators gathering the data transmitted from PHDs through wireless technology, and health information systems storing and managing personal health information transmitted from the information aggregators. International standards such as IEEE 11073 and HL7 have been specified for the interoperability of PHDs and health information systems, but the research on u-Healthcare systems that were developed and applied in the real clinical environment by adopting the standards was rarely conducted. Therefore, we developed an u-Healthcare system which can manage personal health information, such as blood glucose, blood pressure, and body composition, based on health information exchange standards. Moreover, we verified the stability of the developed system through clinical trial in patients with endocrine disease at the Kyungpook National University Hospital, and listed problems occurred during clinical trial and found their solutions.

Study on Protection and Access Control of Personal Bioinformation in Telemecine Environment (원격의료환경에서 개인생체정보 보호 및 무결성에 관한 연구)

  • Kim, Soon Seok;Lee, Jae Hyun
    • Smart Media Journal
    • /
    • v.5 no.4
    • /
    • pp.57-62
    • /
    • 2016
  • By using personal health devices, a type of bio-censor at home and building, for telemedicine, this paper proposes a new method to protect more robust patient's privacy than before scheme [1] by ensuring the integrity and the secure transmission further when it communicates with gateway which collecting bio-information from them. As the suggested method is designed to conform with ISO/IEEE 11073-20601 [2], which is international standard, it considered interoperability with various health devices.

Development of Standard Protocol-based Healthcare Services for Optimized Health Management (최적화된 건강관리를 위한 표준 프로토콜 기반 헬스케어 서비스 개발)

  • Park, Hyun-Sang;Kim, Hyun-Young;Kim, Hwa-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.969-975
    • /
    • 2018
  • The purpose of this study is to develop a healthcare service based on standard protocol and information communication technology for mother's sustainable postpartum care. The developed service was consisted of a client area where mothers measure, manage and transmit their vital signs using their own smartphone and personal health devices, and a server area that manages and shares with the received mother's vital signs and the results of examination results and personal health records. The client area collects vital signs through the IEEE 11073 Personal Health Device (PHD) using the m-health application of the previous study and Continua Health alliance certified personal health devices and transfers to Health Level Seven (HL7) V2.4, Continuity of Care Record (CCR) and Continuity of Care Document (CCD). The server area consists of a mobile web that manages and shares the HL7 Fast Healthcare Interoperability Resources (FHIR)-compliant personal health records to ensure interoperability of examination results, and a mobile web where the postpartum caregiver enters and manages the results of the mother's examination results and provides it to the mother. In this way, the healthcare service of this study securing continued exchanges between the mother and postpartum caregiver improves the quality of life of the mother not only to satisfy the needs of the mother who was discharged but also through self-management and postpartum. In the future, we will conduct a study applying mothers and postpartum caregiver after approval of a clinical trail at a university hospital to evaluate developed healthcare services.

Present Status and Analysis for IEEE 11073 Personal Health Device Specializations (IEEE 11073 개인건강기기별 표준 현황 및 분석)

  • Park, Han-Na;Kim, Seung-Hwan;Yoo, Done-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.469-475
    • /
    • 2012
  • Increasing interest of life expectancy and health has made the u-health industry activating and the several international standard developing organizations(SDO) are dealing with u-health services and technologies. Among them, IEEE 11073 PHD(Personal Health Devices) Work Group is developing standards of personal health device communication for interoperability. There are many studies for introducing SDOs and analyzing the IEEE 11073-20601 standard. However, due to the rare study of PHD standards analysis, there are a lot of difficulties to utilize the standards. In this paper, present status of national and international SDOs including IEEE 11073 standards for PHD will be introduced. Moreover, device specialization standards such as thermometer, weighing scale, glucose meter, blood pressure monitor, electrocardiograph (ECG) etc.. will be analyzed based on the IEEE 11073-20601.

Energy Efficient Wireless Data Transmission for Personal Health Devices

  • Kim, Sang-Kon;Kim, Tae-Kon;Koh, Jin-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1559-1570
    • /
    • 2013
  • The family of ISO/IEEE11073 standards is the basis of the e-health system and provides interoperability for personal health devices. In the early stage of e-health business, it was expected that people would use a health device individually. In this case, a measurement datum was episodically acquired and generally transmitted for one person at a time. Recently, a health device is expected to be used by multiple people, and large amounts of measurement data are gathered in a short time interval. In addition, mobile health devices have become more popular, so that energy efficient measurement data transmission is required, to prolong the use of a device. In IEEE11073 PHD standards, data transmission is classified into three different types: immediate individual transfer, small block transfer, and large block transfer. The large block transfer using PM-store concept provides efficient transmission. However, an existing PM-store has problem when a device is used by multiple people. To address the defined problem, a modified PM-segment that is in compliance with 11073 standards is proposed in this paper. In particular, the proposed PM-segment is designed to minimize the additional complexity of an agent instead of a manager and it is interoperable with the existing manager. The proposed PM-segment shows better performance than the existing PM-segment, in terms of memory requirements and expected queue time. Also, performance comparison among the three transfers is performed in regard to the delay time and communication power consumption points of view.