• Title/Summary/Keyword: perpendicular magnetic field

Search Result 216, Processing Time 0.027 seconds

Effects of Magnetic Field Intensities for Various Lengths of Time on Orientation of Fowl Spermatozoa

  • Pham, Du Ngoc;Shinjo, Akihisa;Sunagawa, Katsunori
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.10
    • /
    • pp.1367-1373
    • /
    • 2001
  • This study used fowl sperm from three White Leghom rooster reared at our laboratory. Semen samples were exposed to the magnetic field strengths of from 650 to 5700 Gauss for one. two, or three days to investigate the influence of magnetic field on the orientation of fowl spermatozoa. Fowl spermatozoa were found to orient with their long axis of heads perpendicular to the magnetic field direction. The fowl spermatozoa were initially influenced when magnetic field intensities were from 650 to 5700 Gauss and the highest values (70.67, 72.49 and 71.79%) were found in the 5700 Gauss treatment at one, two, and three days exposure, respectively. Although percentages of the perpendicular oriented fowl spermatozoa increased along with the enhancement of the magnetic field intensity, the degree of orientation was only significantly higher in the treatments having the magnetic field strength from 1500 to 5700 Gauss than that in the control treatment at all exposure time. In addition, the experimental results also showed that the percentages of all orientational types of fowl spermatozoa (perpendicular category including upward perpendicular and downward perpendicular and parallel type consisting of leftward parallel and rightward parallel) in all treatments tended to be stable during exposure time. From the results of this study. it is suggested that (1) the diamagnetic anisotropy of the inside structural components of fowl spermatozoa induce them to orient perpendicular to the magnetic field direction, (2) the degree of orientation increased according to the enhancement of magnetic field strengths, (3) fowl spermatozoa had not an high sensitivity to the magnetic field, and the level of perpendicular orientation of fowl spermatozoa in this study is nearly similar to that of cattle sperm in the study of Suga et al. (2000).

Calculation of AC Losses by Perpendicular Magnetic Field (수직방향 자장에 의한 교류손실 계산)

  • 이승욱;심정욱;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.172-175
    • /
    • 2001
  • AC loss which is generated in an HTS wire varies with the direction of the external magnetic field. This paper calculates the AC loss in an HTS tape, where effects of the perpendicular direction of the magnetic field are considered. Brandt equation is used to calculate the loss by perpendicular magnetic field. In the calculation, current densities are varied along the variation of the magnitude of the external magnetic field. Results of calculation are compared with those of the conventional method.

  • PDF

Magnetization Loss Characteristics at Arbitrary Directional Magnetic Field by Perpendicular Magnetization Loss in YBCO CC and BSCCO Stacked Conductors (YBCO CC 적층 및 BSCCO tape 적층선재에서 수직자화 손실 값을 이용한 임의 방향 자화손실 평가)

  • Lee, Ji-Kwang;Lim, Hyoung-Woo;Park, Myung-Jin;Cha, Guee-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.282-288
    • /
    • 2007
  • Magnetization loss of high temperature superconductoring BSCCO tape and YBCO coated conductor(YBCOCC) is most important issue in the development of superconducting power devices. In this paper, the measured results of magnetization losses under various angles of external magnetic field in BSCCO tape stacked conductors and YBCO CC stacked conductors are presented and compared with each other. Also, we present the compared results of magnetization losses measured at arbitrary reaction magnetic fields and analyzed with perpendicular magnetic field components of those. The results show that magnetization losses of YBCO CC single and stacked conductors agree well with the analyzed value by it's perpendicular magnetic field component, but BSCCO single and stacked conductors are not.

Metastable Vortex State of Perpendicular Magnetic Anisotropy Free Layer in Spin Transfer Torque Magnetic Tunneling Junctions

  • You, Chun-Yeol;Kim, Hyungsuk
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.380-385
    • /
    • 2013
  • We find a metastable vortex state of the perpendicular magnetic anisotropy free layer in spin transfer torque magnetic tunneling junctions by using micromagnetic simulations. The metastable vortex state does not exist in a single layer, and it is only found in the trilayer structure with the perpendicular magnetic anisotropy polarizer layer. It is revealed that the physical origin is the non-uniform stray field from the polarizer layer.

Advanced Circuit-Level Model of Magnetic Tunnel Junction-based Spin-Torque Oscillator with Perpendicular Anisotropy Field

  • Kim, Miryeon;Lim, Hyein;Ahn, Sora;Lee, Seungjun;Shin, Hyungsoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.556-561
    • /
    • 2013
  • Interest in spin-torque oscillators (STOs) has been increasing due to their potential use in communication devices. In particular the magnetic tunnel junction-based STO (MTJ-STO) with high perpendicular anisotropy is gaining attention since it can generate high output power. In this paper, a circuit-level model for an in-plane magnetized MTJ-STO with partial perpendicular anisotropy is proposed. The model includes the perpendicular torque and the shift field for more accurate modeling. The bias voltage dependence of perpendicular torque is represented as quadratic. The model is written in Verilog-A, and simulated using HSPICE simulator with a current-mirror circuit and a multi-stage wideband amplifier. The simulation results show the proposed model can accurately replicate the experimental data such that the power increases and the frequency decreases as the value of the perpendicular anisotropy gets close to the value of the demagnetizing field.

Current-Driven Domain-Wall Depinning in Pt/CoFe/Pt Nanowires with Perpendicular Magnetic Anisotropy

  • Kim, Kab-Jin;Lee, Jae-Chul;Choe, Sug-Bong
    • Journal of Magnetics
    • /
    • v.14 no.3
    • /
    • pp.101-103
    • /
    • 2009
  • The spin transfer torque efficiency was determined experimentally by observing the current-driven domainwall depinning of Pt/CoFe/Pt nanowires with perpendicular magnetic anisotropy. The depinning time was exponentially proportional to the applied magnetic field, and was well explained by the Neel-Brown formula. The depinning time and threshold magnetic field were varied considerably by injecting current into the nanowire. The spin transfer torque efficiency was estimated to be $(7.2{\pm}0.9){\times}10^{-15}Tm^2$/A from the linear dependence of the threshold current density with respect to the applied magnetic field.

Design and Development of the Magnetic Tomography System Using Two Poles Perpendicular Magnetic Field (2극 수직자계를 이용한 Magnetic Tomograpy의 설계와 제작)

  • 박은식;박관수
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.61-67
    • /
    • 2003
  • This paper describes a development of magnetic tomography system using two poles perpendicular magnetic field. In the system, the relative permeabilities of the object are detected by Hall sensors located along with tube circumference. The signals according to the size and position of the object could be separated in case the relative permeability of the object are over 10. Moreover, the size and location of the object could be determined in real time.

Magnetic Orientations of Bull Sperm Treated by DTT or Heparin

  • Suga, D.;Shinjo, A.;Kumianto, E.;Nakada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.1
    • /
    • pp.10-18
    • /
    • 2000
  • This paper describes the magnetic orientation of the intact and demembranated bull sperm treated by DTT or heparin in a 5,400 G static field. Semen samples collected from four bulls (Japanese Black) were mixed to the same sperm density. One percentage triton X-100 was used to extract the plasma membrane. The intact and demembranated sperm suspensions were treated with 20, 200, 2,000 mM DTT, 100, 1,000 or 10,000 units heparin solutions at $4{^{\circ}C}$ for 6 days. The decondensation of the sperm nuclei treated by DTT or heparin was examined by measuring the sperm head area at 1, 3, and 6 days. After measuring the area, each sperm sample was exposed to a 5,400 G static magnetic field generated by Nd-Fe-B permanent magnets for 24 hours at room temperature. Results showed that the decondensation of bull sperm nuclei was not induced by the heparin treatment, however, incomplete decondensation was induced by the DTT treatment. During the magnetic orientation, bull sperms treated by DTT or heparin had low percentages of long axis perpendicular to the magnetic lines of force. However, different aspects were obtained for long axis perpendicular orientations following treatment of DTT or heparin. Through the DTT treatment, the decline of long axis perpendicularly oriented percentages was due to the increase of long axis parallel orientation with the head of the flat plane perpendicular to the magnetic lines of force, whereas, using the heparin treatment, the decline of long axis perpendicular orientation was due to the increment of long axis parallel orientation with the head of the flat plane parallel to the magnetic lines of force. Also, percentages of the head of the flat plane perpendicular were decreased by the heparin treatment. These findings suggest that maintaining the structure of protamine in the chromatin is necessary for the sperm head to orient with its flat plane perpendicular, and maintaining the disulfide bond in the chromatin is necessary for the long axis of sperm to orient perpendicularly.

Underlayer effects on crystallographic and magnetic characteristics of Co-Cr(-Ta) layer (Co-Cr(-Ta) 층의 결정성 및 자기적 특성에 미치는 하지층 효과)

  • 금민종;공석현;가출현;손인환;김경환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.208-211
    • /
    • 2000
  • We prepared Co-Cr-Ta and Co-Cr-Ta/Ti thin film for perpendicular magnetic recording media by facing targets sputtering system (FTS system). Ti underlayer effects on crystallographic and magnetic characteristics of Co-Cr-Ta perpendicular magnetic recording media have been investigated. Crystallgraphic and magnetic characteristic of prepared thin films were evaluated by x-ray diffractometry(XRD), vibrating sample magnetometer(VSM) and kerr hysteresis loop measurement. The coercivity and anisotropy field increase by introduced Ti underlayer when substrate temperature is higher than 150$^{\circ}C$. The c-axis dispersion angle and grain size of Co-Cr-Ta/Ti thin film is decrease than Co-Cr-Ta when substrate temperature is higher than 100$^{\circ}C$. Consequently, the use of a Ti underlayer highly orientated can be improved crystallographic and magnetic characteristics of Co-Cr -Ta perpendicular media layer.

  • PDF

Improvement of characteristics and dependence on underlayer substrate temperature of CoCrTa/Ti double layer (CoCrTa/Ti 이층막의 하지층기판온도의존성 및 특성개선)

  • 김용진;성하윤;금민종;손인환;김경환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.492-495
    • /
    • 2000
  • In order to develop an ultra-thin CoCr perpendicular magnetic recording layer, we prepared CoCrTa/Ti double layer for perpendicular magnetic recording media by new facing targets sputtering system, Crystallgraphics and magnetic characteristics of CoCrTa on underlayer substrate temperature have been investigated. Crystallgraphic and magnetic characteristic of thin films were evaluated by X-ray diffractometry(XRD), vibrating sample magnetometer(VSM) and atomic force microscopy(AFM). The coercivity and anisotropy field was increased by increasing under layer substrate temperature, c-axis orientation of CoCrTa magnetic recording layer was improved 8$^{\circ}$ to 5.6$^{\circ}$when under layer substrate temperature was 250[$^{\circ}C$]. Also, through annealing effect for CoCrTa/Ti double layer, it was certain that crystallgraphics and magnetic characteristics was improved.

  • PDF