• Title/Summary/Keyword: peroxone AOP

Search Result 5, Processing Time 0.018 seconds

Study on Treatment Characteristic of Advanced Oxidation Process using Ozone Oxidation and Peroxone AOP Process for Waste Dyeing Water Effluent Treatment (오존접촉산화 공정과 Peroxone AOP 공정을 이용한 염색폐수방류수 고도산화 처리특성 연구)

  • Park, Jun-Hyung;Shin, Dong-Hoon;Ryu, Seong-Han;Jo, Seog-Jin;Lee, Sang-Hun
    • Textile Coloration and Finishing
    • /
    • v.23 no.4
    • /
    • pp.274-283
    • /
    • 2011
  • Effect of pH on ozone oxidation and peroxone AOP(Advanced Oxidation Process) process was analyzed and the optimal efficiency for both processes was obtained at pH 7.5. In case of ozone oxidation process, the efficiencies of color, $COD_{Mn}$ and $BOD_5$ removal were measured to 93%, 70% and 89% at a reaction time of 50 min(ozone dosage of 111.67mg/$\ell$). When reaction time increased to 90 min(ozone dosage of 201mg/$\ell$), the efficiencies of color, $COD_{Mn}$ and $BOD_5$ removal were increased by 3~5 %, indicating that the increment of removal efficiency was insignificant considering longer reaction time. Similarly, the ozone/$H_2O_2$ ratio was optimized to 0.5 for peroxone AOP process. Removal efficiencies of color, $COD_{Mn}$ and $BOD_5$ were measured 95%, 81% and 94% at a reaction time of 50 min(ozone dosage of 111.67mg/$\ell$). When reaction time increased to 90min(ozone dosage of 201mg/$\ell$), the removal efficiency of color, CODMn, and BOD5 increased slightly by 1~5%.

Study on the Removal Characteristics of Diazinon Using Ozone / Hydrogen Peroxide (오존/과산화수소공정(Peroxone AOP)을 이용한 Diazinon 제거 특성 연구)

  • Youn, Hyojin;Han, Ihnsup;Yoon, Woohyun
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.391-399
    • /
    • 2018
  • In this study, Diazinon which is the most widely used organophosphorus pesticides (OPPs) among pesticides was removed by ozone/hydrogen peroxide advanced oxidation process (Peroxone AOP). Diazinon is mainly found in groundwater, drinking water, rivers and ponds that are near agricultural areas using the pesticide. Accumulation of Diazinon on the body in the form of metabolites causes neurotoxicity, confusion, dizziness and vomiting. Diazinon is not easily removed by conventional water treatment processes. This study investigated the Diazinon removal characteristics with OH radicals with strong oxidizing power generated by using ozone and hydrogen peroxide. We determined optimal hydrogen peroxide/ozone injection molar ratio and confirmed the elimination reaction to initial Diazinon concentration, pH and DOC concentration, which are factors influencing the removal efficiency. Domestic researches on pesticide removal in the environment are much less than the cases of overseas. This study is expected to provide a basis for the process design for pesticide removal.

Use of Hydrogen Peroxide with Ozone to Simultaneously Reduce MIB and Quench Ozone Residual in Existing Water Treatment Plants Sourcing Water from the Han River (한강을 원수로 하는 오존/과산화수소 고도정수처리공정에서의 MIB제거 및 잔류오존 농도에 관한 연구)

  • McAdams, Stephen R.;Koo, Bon Jin;Jang, Myung Hoon;Lee, Sung Kyoo
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.704-716
    • /
    • 2012
  • This paper provides a detailed account of pilot testing conducted at South Lake Tahoe (California), the Ddukdo (Seoul) water treatment plant (WTP) and the Bokjung (Seongnam) WTP between February, 2010, and February, 2012. The objectives were first, to characterize the reactions of ozone with hydrogen peroxide (Peroxone) for Han River water following sand filtration, second to determine empirical ozone and hydrogen peroxide doses to remove a taste-and-odor surrogate 2-methylisoborneol (MIB) using an advanced oxidation process (AOP) configuration and third, to determine the optimum dosing configuration to reduce residual ozone to a safe level at the exit of the process. The testing was performed in a real-time plant environment at both low- and high seasonal water temperatures. Experimental results including ozone decomposition rates were dependent on temperature and pH, consistent with data reported by other researchers. MIB in post-sand-filtration water was spiked to 40-50 ng/L, and in all cases, it was reduced to below the specified target level (7 ng/liter) and typically non-detect (ND). It was demonstrated that Peroxone could achieve both MIB removal and low effluent ozone residual at ozone+hydrogen peroxide doses less than those for ozone alone. An empirical predictive model, suitable for use by design engineers and operating personnel and for incorporation in plant control systems was developed. Due to a significant reduction in the ozone reaction/decomposition at low winter temperatures, results demonstrate the hydrogen peroxide can be "pre-conditioned" in order to increase initial reaction rates and achieve lower ozone residuals. Results also indicate the method, location and composition of hydrogen peroxide injection is critical to successful implementation of Peroxone without using excessive chemicals or degrading performance.

Removal Characteristics of Residual Hydrogen Peroxide (H2O2) according to Application of Peroxone Process in O3/BAC Process (O3/BAC 공정에서 Peroxone 공정 적용에 따른 잔류 과산화수소 제거 특성)

  • Yeom, Hoon-Sik;Son, Hee-Jong;Seo, Chang-Dong;Kim, Sang-Goo;Ryu, Dong-Choon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.889-896
    • /
    • 2013
  • Advanced Oxidation Processes (AOP) have been interested for removing micropollutants in water. Most of water treatment plants (WTPs) located along the lower part of Nakdong River have adopted the $O_3/BAC$ process and have interesting in peroxone process a kind of AOP. This study evaluated the removal characteristics of residual hydrogen peroxide ($H_2O_2$) combining with the biofiltration process in the next BAC process when the hydrogen peroxide is applied for the WTP operating $O_3/BAC$ process. In the experiment, changing the temperature and the concentration of $H_2O_2$ of influent, the biofiltration process showed rapidly dropped the biodegradability when the $H_2O_2$ concentration was increased and lowered water temperature while BAC process maintained relatively stable efficiency. The influent fixed at $20^{\circ}C$ and the concentration of $H_2O_2$ at 300 mg/L was continuously input for 78 hours. Most of the $H_2O_2$ in the influent did not remove at the biofiltration process controlled 5 to 15 minutes EBCT condition after 24~71 hours operating time while BAC process controlled 5 to 15 minutes EBCT showed 38~91% removal efficiency condition after 78 hours operating time. Besides, after 78 hours continuously input experiment, the biomass and activity of attached bacterial on the biofilter and BAC were $6.0{\times}10^4CFU/g$, $0.54mg{\cdot}C/m^3{\cdot}hr$ and $0.4{\times}10^8CFU/g$, $1.42mg{\cdot}C/m^3{\cdot}hr$ respectively. These biomass and activity values were decreased 99% and 72% in biofilter and 68% and 53% in BAC compared with initial condition. The biodegradation rate constant ($k_{bio}$) and half-life ($t_{1/2}$) in BAC were decreased from $1.173min^{-1}$ to $0.183min^{-1}$ and 0.591 min to 3.787 min respectively according to increasing the $H_2O_2$ concentration from 10 mg/L to 300 mg/L at $5^{\circ}C$ water temperature and the $k_{bio}$ and $t_{1/2}$ were $1.510min^{-1}$ to $0.498min^{-1}$ and 0.459 min to 1.392 min at $25^{\circ}C$ water temperature. By increasing the water temperature from $5^{\circ}C$ to $15^{\circ}C$ or $25^{\circ}C$, the $k_{bio}$ were increased 1.1~2.1 times and 1.3~4.4 times. If a water treatment plant operating $O_3/BAC$ process is considering the hydrogen peroxide for the peroxone process, post BAC could effectively decrease the residual $H_2O_2$, moreover, in case of spilling the $H_2O_2$ into the water process line, these spilled $H_2O_2$ concentration can be able to decrease by increasing the EBCT at the BAC process.

Study on characteristic of Advanced oxidation process for improvement of dyeing wastewater effluent quality (염색폐수 방류수 수질개선을 위한 고도산화처리에 관한 연구)

  • Lee, Sang-Hun;Park, Jun-Hyung;Shin, Dong-Hoon;Ryu, Seung-Han
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.118-118
    • /
    • 2012
  • 현재 정부는 친환경녹색성장을 모티브로 환경기준을 강화하고 있으며, 오염 발생원을 최소화 하고자 현재 가동중인 환경기초시설을 대상으로 고도산화공정을 추가하여 오염 배출량을 최소화 하도록 정부와 지자체가 독려하고 있는 중이다. 따라서 대표적인 환경오염 업종인 섬유/염색 관련업체는 강화되는 환경기준을 만족하기 위한 공정검토가 불가피한 현실이다. 특히 대구 OO염색공단은 염색업체가 집적되어 있어 난분해성 오염물질과 색도유발물질이 다량 발생되고 있으며, 폐수처리장에서 운영 중인 재래식 폐수처리공정으로는 강화되는 방류수 수질기준을 충족할 수 없다. 따라서 본 연구에서는 방류수 수질기준을 만족하기 위한 고도산화 공정을 검토하였으며, 그 공정의 최적인자를 도출하고자 하였다. 고도산화 공정에서 오존산화, Peroxone AOP, Fenton oxidation 공정을 검토하였으며, 강화되는 수질기준을 만족할 수 있는 최적인자 및 처리효율을 검토하였다. 그 결과 조건에 따라 COD, T-N, T-P, 색도 등에서 처리효율은 40 ~ 90% 범위로 경제성을 고려하여 최적의 운전조건을 도출 하였다.

  • PDF