• Title/Summary/Keyword: permeate rate

Search Result 124, Processing Time 0.022 seconds

Dyestuff Wastewater Treatment by Membrane Separation as Post-treatment after lenten막s Reaction (펜턴반응후 후처리로써 막분리에 의한 염색폐수처리)

  • 김선일;윤영재
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.74-80
    • /
    • 1998
  • Because permeate flux was very low as It has the suspension soled of higher concentration In the trafiltration membrane separation treatment of dyestuff wastewater, pre-treatment of Ponton reaction was carried out. In the case of pH 3, COD removal rate was the hi각erst of 58%. When PAC was added into the pre-treatment supernatant, the COD removal rate was found to be 53% , and when COD was 153mg/L, the removal rate was 92.3% in the trafiltration separation. In addition, the effect of the addition of PAC on the permeate flux was also investigated. The decrease of permeate flux In the presence of PAC was higher than In the abscence of PAC, but the recovery of permeability by cleaning was better In the case of PAC system.

  • PDF

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • v.10 no.5
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

Studies on the Separation of Taste Components from Sea Tangle (Laminaria japonica) Extract by Cross Flow Ultrafiltration (한외여과에 의한 다시마 정미성분 분리에 대한 연구)

  • Lee, Ho-Bong;Lee, Seung-Ryeol;Chang, Young-Sang;Shin, Zae-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.199-203
    • /
    • 1992
  • This study was aimed to optimize the required condition for recovering the low soluble taste component obtained from sea tangle extract using ultrafiltration, and to investigate effects of membrane type, temperature, transmembrane pressure and flow rate respectively. We also compared relationship between the profile of permeate flux and the recovery yield of taste component under the selected optimal condition using ultrafiltration and diafiltration. Hydrophobic GR 51 PP membrane kept higher average permeate flux than hydrophilic FS membrane, and average permeate flux also had increasing tendency in relation to rising flow rate but it showed limit value of 3.7 l/min. Average permeate flux decreased as transmembrane pressure increased but it showed little change with rising temperature. Investigation upon average permeate flux, total dissolved solid and recovery yield of taste components using ultrafiltration and diafiltration resulted in relatively higher recovery yield in ultrafiltration. Compared ultrafiltration and diafiltration, average permeate flux was lower in ultrafiltration.

  • PDF

Sensitivity analysis and Taguchi application in vacuum membrane distillation

  • Upadhyaya, Sushant;Singh, Kailash;Chaurasia, Satyendra Prasad;Baghel, Rakesh;Singh, Jitendra Kumar;Dohare, Rajeev Kumar
    • Membrane and Water Treatment
    • /
    • v.9 no.6
    • /
    • pp.435-445
    • /
    • 2018
  • In this work, desalination experiments were performed on vacuum membrane distillation (VMD). Process parameters such as feed flow rate, vacuum degree on permeate side, feed bulk temperature and feed salt concentration were optimized using sensitivity analysis and Taguchi method. The optimum values of process parameters were found to be 2 lpm of feed flow rate, $60^{\circ}C$ of feed bulk temperature, 5.5 kPa of permeate-side pressure and 5000 ppm of salt concentration. The permeate flux at these conditions was obtained as $26.6kg/m^2{\cdot}hr$. The rejection of salt in permeate was found to be 99.7%. The percent contribution of various process parameters using ANOVA results indicated that the most important parameter is feed bulk temperature with its contribution of 95%. The ANOVA results indicate that the percent contribution of permeate pressure gets increased to 5.384% in the range of 2 to 7 kPa as compared to 0.045% in the range of 5.5 to 7 kPa.

Application of a Membrane Bioreactor in Denitrification of Explosives Hydrolysates (Membrane Bioreactor를 이용한 폭발성 물질의 가수분해 부산물의 탈질과정에의 적용)

  • Zoh, Kyung-Duk
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.113-122
    • /
    • 2002
  • A bench-scale anoxic membrane bioreactor (MBR) system, consisting of a bioreactor coupled to a ceramic crossflow ultrafiltration module, was evaluated to treat a synthetic wastewater containing alkaline hydrolysis byproducts (hydrolysates) of RDX, The wastewater was formulated the same as RDX hydrolysates, and consisted of acetate, formate, formaldehyde as carbon sources and nitrite, nitrate as electron accepters. The MBR system removed 80 to 90% of these carbon sources, and approximately 90% of the stoichiometric amount of nitrate, 60% of nitrite. The reactor was also operated over a range of transmembrane pressures, temperatures, suspended solids concentration, and organic loading rate in order to maximize treatment efficiency and permeate flux. Increasing transmembrane pressure and temperature did not improve membrane flux significantly. Increasing biomass concentration in the bioreactor decreased the permeate flux significantly. The maximum volumetric organic loading rate was $0.72kg\;COD/m^3/day$, and the maximum F/M ratio was 0.50 kg N/kg MLSS/day and 1.82 kg COD/kg MLSS/day. Membrane permeate was clear and essentially free of bacteria, as indicated by heterotrophic plate count. Permeate flux ranged between 0.15 and $2.0m^3/m^2/day$ and was maintained by routine backwashing every 3 to 4 day. Backwashing with 2% NaOCl solution every fourth or fifth backwashing cycle was able to restore membrane flux to its original value.

Studies on the Efficient Concentration Process of Apple Juice with Reverse Osmosis Process (역삼투막 공정을 이용한 사과쥬스의 효율적인 농축공정에 관한 연구)

  • Hur, Sang-Sun;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.321-326
    • /
    • 1993
  • Membrane separation technology with polymeric membranes for the effective separation and energy conservation has emerged to be a new technology for separation in recent years. In this research, the reverse osmosis process was applied to the concentration process of clarified apple juices. The changes of concentration and permeate flux of apple juice in this process were measured at different membrane characteristics, operating pressures, temperature and flow rate. And the changes of quality were also measured at different pressures. The prediction model for the permeate flux based on these data was established. Generally, the osmotic pressure increased as the concentration of the feed increased in the RO process, which caused a reduction of permeate flux. The changes of permeate flux were not much dependent on temperature and flow rate, but very much dependent on pressure. The most effective factor in increased permeate flux was found to be the operating pressure, followed by temperature and flow rate. The final prediction model for the permeate flux was developed by the $SPSS^x$ computer program. The result showed that recovery of sugar was not affected by processing pressures, but the percentage recovery of total flavor was increased with increasing pressure.

  • PDF

A Study on the Flux and Heat Transfer of Direct Contact Type Module Applied for a Pilot Scale Membrane Distillation Process (파일럿 규모 막 증발 공정 적용을 위한 직접 접촉식 모듈의 투과유속 및 열에너지 이동에 관한 연구)

  • Kim, Seung Hwan;Kim, Se Woon;Lee, Dong Woo;Cho, Jin Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.229-236
    • /
    • 2017
  • In this study, a direct contact membrane module was manufactured to be used in a pilot scale membrane distillation process to treat $3m^3/day$ of the digestate produced from anaerobic digestion of livestock manure. In order to investigate the performance of the membrane module, permeate flux was measured with and without spacer inside the module under various condition of temperature difference and cross flow velocity (CFV) through the membrane surfaces. Flux recovery rate after chemical cleaning was also investigated by applying three different cleaning methods. Additionally, thermal energy consumption was theoretically simulated based on actual pilot plant operation conditions. As results, we observed flux of the module with spacer was almost similar to the theoretically predicted value because the installation of spacer reduced the channeling effect inside the module. Under the same operating condition, the permeate flux also increased with increasing temperature difference and CFV. As a result of chemical in-line cleaning using NaOCl and citric acid for the fouled membranes, the recovery rate was 83.7% compared to the initial flux when NaOCl was used alone, and 87% recovery rate was observed when only citric acid was used. However, in the case of using only citric acid, the permeate flux was decreased at a rapid rate. It seemed that a cleaning by NaOCl was more effective to recover the flux of membrane contaminated by the organic matter as compared to a cleaning by citric acid. The total heat energy consumption increased with increasing CFV and temperature difference across the membrane. Thus, further studies should be intensively conducted to obtain a high permeate flux while keeping the energy consumption to a minimum for a practical application of membrane distillation process to treat wastewater.

Nitrogen and Phosphorus Removal Characteristics from Domestic Sewage using Two Stage Membrane Bioreactor (2단형 막분리 활성슬러지법(Two Stage MBR)에서 내부순환율 변화와 응집제 첨가에 의한 질소 및 인제거 특성에 관한 연구)

  • Park, Jae-Roh;Lim, Hyun-man;Kim, Eoung Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.131-140
    • /
    • 2002
  • Laboratory-scale membrane bioreactor added alum into the anaerobic basin as a flocculant and adsorbent was carried out to find removal efficient of nitrogen and phosphorus components in the mixed liquid and weather or not maintaining the stability for the permeate flux and pressure at various internal recycle conditions. It was found that denitrification efficient of maximum 65% was obtained when the ratio of internal recycle was 3Q. Additionally when the ratio of internal recycle was fixed at 3Q, $BOD_5$ and T-P concentration of permeate was much more reduced compared to not added alum in anaerobic basin but T-N concentration of permeate was relatively increased. In case of added alum as the flocculant and adsorbent in anaerobic basin, the permeate flux was maintained above $10{\ell}/m^2/hr$ but the permeate pressure was relatively higher than alum was not added in anaerobic basin.

Experimental and Theoretical Consideration for Flow Rate, Pressure Drop, and Permeate Flow in a Hollow Fiber Membrane (중공사 막을 따라 흐르는 순수한 물의 유량, 압력손실, 투과수에 대한 실험과 이론적 고찰)

  • Lee, Jung-Muk;Lee, Bomsock
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.470-480
    • /
    • 2012
  • In this study, for a linear tubular membrane with constant diameter the mass balance considering permeate velocity of the each unit length was established. On this basis, mathematical modelling of flows in a pipe was solved using nonlinear second order differential equations as well as steady-state equation. Since this equation is nonlinear, Gauss-Seidel method or another iteration method were used to solve the differential equations. Simulation algorithm for numerical solutions was presented. Also since the permeate flow is varied as operating condition, the solution of equations at each conditions using numerical integrations such as Simpson's rules was used. In order to analyze and compare simulation results, we have performed experiments using a hollow fiber membrane with almost identical tubular membrane. Comparison of theoretical and experimental results, pressure drop, flow rate, and permeate flow in a hollow fiber membrane, were illustrated.

Effect of Salt Concentration and Temperature in Synthetic Dyestuff Wastewater Treatment using Plate and Frame Membrane Module (평판형 막모듈을 이용한 합성염료 폐수처리에 있어서 염농도 및 온도의 영향)

  • Kim, Sun-Il;Lee, Bong-Woo;Yun, Young-Jae
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.209-216
    • /
    • 1998
  • Nanofiltration[NF45] and reverse osmosis membrane(HR98PP) separation treatment of dyestuff wastewater was carried out In order to separate relatively pure water from synthetic dyestuff wastewater, which consists of reactive dye, acid dye, basic dye, direct dye, and disperse dye. The experiments were performed by using the plate and frame membrane module. In the nanofiltration and reverse osmosis membrane separation, When the NaCl concentration was 0.1, 5.0, and 20.091, retention was 63.0, 46.0, 0.9%, respectively. When permeate flux was 125.0, 67.5, and 45.0 L/$m^2$ h, the osmotic pressure increased with Increasing the NaCl concentration. Permeate flux of two membranes Increased as temperature Increased due to segmental movement of polymer of the membrane and the rejection rate of dyestuff was decreased gradually. It was found that the rejection rate was about 95% in the nanofiltratlon, while the reverse osmosis membrane showed a high rejection rate of 99% under all temperature and pressures conditions.

  • PDF