• 제목/요약/키워드: permeability distribution

검색결과 335건 처리시간 0.028초

고로하부 액체유동에 대한 수치해석 사례 - 냉간유동 (Numerical Simulation of the Liquid Flow in the Lower Part of the Blast Furnace - A Cold Flow Case)

  • 진홍종;최상민;정진경
    • 한국연소학회지
    • /
    • 제13권2호
    • /
    • pp.33-41
    • /
    • 2008
  • The high permeability of the gas in the molten iron of the dripping zone of the blast furnace is a major factor in achieving the stable operation of a furnace with high productivity. Basic studies of the liquid flow behavior in a packed bed are necessary to grasp the effect of various operational changes on conditions in the dropping zone. Molten iron and slag together playa critical role in the lower zone, transporting mass and energy, while impairing and redistributing the gas flow. In turn, molten iron and slag undergo physical and chemical changes, and are redistributed radially as they descend to the hearth. In this research, mathematical formulations are derived for the gas and the liquid. The solid phase is fixed with constant porosity. The information for the molten iron and slag includes the hold-up, velocity, pressure, and information related to the areas of interaction between the gas and the liquid, and the solid and the liquid. Predictable results include the velocity, pressure and temperature distribution. Additional parameters include the packed particle size and the air blast rate.

  • PDF

폐비닐 골재의 기본특성에 관한 연구 (An Experimental Study on the Waste Polyethylene Aggregate for Construction Materials)

  • 김영진
    • 한국지반환경공학회 논문집
    • /
    • 제4권4호
    • /
    • pp.5-16
    • /
    • 2003
  • 농촌 비닐하우스 등에서 발생하는 폐비닐을 재활용하기 위한 방법의 하나로 폐비닐을 이용하여 골재를 만들었다. 이 골재에 대하여 용출시험, 비중시험, 다짐시험, LA마모시험, 대형전단시험, 투수시험 등 물리적, 역학적 시험을 실시하였다. 또한 폐비닐골재에 대한 열전도시험, 부동수분시험, 동상시험을 실시하였으며, 현장에서 폐비닐골재와 자갈을 도로 동상방지층에 포설한 후 두 해 겨울철에 걸쳐 각각의 온도분포를 측정하여 그 결과를 비교하였다.

  • PDF

세라믹필터 집진장치의 역세정 시스템 설계를 위한 유동해석 (A Numerical Analysis of Pulse-Jet Cleaning Characteristics for Ceramic Filter System Design)

  • 정재화;서석빈;김시문;안달홍;김종진
    • 에너지공학
    • /
    • 제12권3호
    • /
    • pp.197-206
    • /
    • 2003
  • 본 연구에서는 다공성 세라믹 필터를 사용하는 집진장치에서 역세정 과정의 유동특성을 규명하고, 역세정 시스템 설계에 적용하기 위한 전산해석을 수행하였다. 주요 연구내용으로는 역세정 과정에서 중요한 변수인 노즐 직경, 노즐 팁의 위치, 다공성 세라믹 캔들필터의 투과율, 디퓨저 형상, 역세정 압력 등이 집진장치 내부에서의 속도분포, 압력분포 등 역세정 유동특성에 미치는 영향을 상세히 계산하여 역세정 시스템의 사양 설계에 활용할 수 있도록 하였다. 전산해석에는 상용의 FLUENT code를 사용하여 에너지 보존식을 포함한 압축성 축대칭 Navier-Stokes 방정식을 유한체적법 (Finite volume method)으로 해석하였다.

이질적 경관에서의 연결성 측정: 리뷰 및 적용 (Measuring Connectivity in Heterogenous Landscapes: a Review and Application)

  • 송원경;김은영;이동근
    • 환경영향평가
    • /
    • 제21권3호
    • /
    • pp.391-407
    • /
    • 2012
  • The loss of connectivity and fragmentation of forest landscapes are seriously hindering dispersal of many forest-dwelling species, which may be critical for their viability and conservation by decreasing habitat area and increasing distance among habitats. For understanding their environmental impacts, numerous spatial models exist to measure landscape connectivity. However, general relationships between functional connectivity and landscape structure are lacking, there is a need to develop landscape metrics that more accurately measure landscape connectivity in whole landscape and individual patches. We reviewed functional and structural definition of landscape connectivity, explained their mathematical connotations, and applied representative 13 indices in 3 districts of Seoul having fragmented forest patches with tits, the threshold distance was applied 500m by considering the dispersal of tits. Results of correlation and principal component analysis showed that connectivity indices could be divided by measurement methods whether they contain the area attribute with distance or not. Betweenness centrality(BC), a representative index measuring distance and distribution among patches, appreciated highly stepping stone forest patches, and difference of probability of connectivity(dPC), an index measuring including area information, estimated integrated connectivity of patches. Therefore, for evaluating landscape connectivity, it is need to consider not only general information of a region and species' characteristics but also various measuring methods of landscape connectivity.

Magneto-thermo-elastic response of a rotating functionally graded cylinder

  • Hosseini, Mohammad;Dini, Ali
    • Structural Engineering and Mechanics
    • /
    • 제56권1호
    • /
    • pp.137-156
    • /
    • 2015
  • In this paper, an analytical solution of displacement, strain and stress field for rotating thick-walled cylinder made of functionally graded material subjected to the uniform external magnetic field and thermal field in plane strain state has been studied. Stress, strain and displacement field as a function of radial coordinates considering magneto-thermo-elasticity are derived analytically. According to the Maxwell electro-dynamic equations, Lorentz force in term of displacement is obtained in cylindrical coordinates. Also, symmetric temperature distribution along the thickness of hollow cylinder is obtained by solving Fourier heat transfer equation in cylindrical coordinates. Using equation of equilibrium and thermo-mechanical constitutive equations associated with Lorentz force, a second-order inhomogeneous differential equation in term of displacement is obtained and will be solved analytically. Except Poisson's ratio, other mechanical properties such as elasticity modulus, density, magnetic permeability coefficient, heat conduction coefficient and thermal expansion coefficient are assumed to vary through the thickness according to a power law. In results analysis, non-homogeneity parameter has been chosen arbitrary and inner and outer surface of cylinder are assumed to be rich metal and rich ceramic, respectively. The effect of rotation, thermal, magnetic field and non-homogeneity parameter of functionally graded material which indicates percentages of cylinder's constituents are studied on displacement, Von Mises equivalent stress and Von Mises equivalent strain fields.

Characterization of Preclinical in Vitro and in Vivo Pharmacokinetic Properties of KPLA-012, a Benzopyranyl 1,2,3-Triazole Compound, with Anti-Angiogenetic and Anti-Tumor Progressive Effects

  • Nam, So Jeong;Lee, Taeho;Choi, Min-Koo;Song, Im-Sook
    • Mass Spectrometry Letters
    • /
    • 제9권2호
    • /
    • pp.61-65
    • /
    • 2018
  • KPLA-012, a benzopyranyl 1,2,3-triazole compound, is considered a potent $HIF-1{\alpha}$ inhibitor based on the chemical library screening, and is known to exhibit anti-angiogenetic and anti-tumor progressive effects. The aim of this study was to investigate the pharmacokinetic properties of KPLA-012 in ICR mice and to investigate in vitro characteristics including the intestinal absorption, distribution, metabolism, and excretion of KPLA-012. The oral bioavailability of KPLA-012 was 33.3% in mice. The pharmacokinetics of KPLA-012 changed in a metabolism-dependent manner, which was evident by the low recovery of parent KPLA-012 from urine and feces and metabolic instability in the liver microsomes. However, KPLA-012 exhibited moderate permeability in Caco-2 cells ($3.1{\times}10^{-6}cm/s$) and the metabolic stability increased in humans compared to that in mice (% remaining after 1 h; 47.4% in humans vs 14.8% in mice). Overall, the results suggest that KPLA-012 might have more effective pharmacokinetic properties in humans than in mice although further studies on its metabolism are necessary.

Correlation Between Bulk and Surface Resistivity of Concrete

  • Ghosh, Pratanu;Tran, Quang
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권1호
    • /
    • pp.119-132
    • /
    • 2015
  • Electrical resistivity is an important physical property of portland cement concrete which is directly related to chloride induced corrosion process. This study examined the electrical surface resistivity (SR) and bulk electrical resistivity (BR) of concrete cylinders for various binary and ternary based high-performance concrete (HPC) mixtures from 7 to 161 days. Two different types of instruments were utilized for this investigation and they were 4 point Wenner probe meter for SR and Merlin conductivity tester for bulk resistivity measurements. Chronological development of electrical resistivity as well as correlation between two types of resistivity on several days was established for all concrete mixtures. The ratio of experimental surface resistance to bulk resistance and corresponding resistivity was computed and compared with theoretical values. Results depicted that bulk and SR are well correlated for different groups of HPC mixtures and these mixtures have attained higher range of electrical resistivity for both types of measurements. In addition, this study presents distribution of surface and bulk resistivity in different permeability classes as proposed by Florida Department of Transportation (FDOT) specification from 7 to 161 days. Furthermore, electrical resistivity data for several HPC mixtures and testing procedure provide multiple promising options for long lasting bridge decks against chloride induced corrosion due to its ease of implementation, repeatability, non-destructive nature, and low cost.

진동막분리장치에 의한 반도체폐수처리와 재이용에 관한 연구 (A Study on the Semiconductor Wastewater Treatment and Recycling by VSEP system)

  • 강경환
    • 한국환경과학회지
    • /
    • 제14권3호
    • /
    • pp.335-343
    • /
    • 2005
  • The objective of this research is to evaluate a feasibility of wastewater reuse by membrane treatment with vibrating membrane separation equipment. Molecular weight of compounds in wastewater, permeability of membrane and retentate characterization after membrane filtration were investigated in order to determine appropriate membrane pore size and materials for wastewater treatment. Selected membrane was evaluated with vibration membrane separation equipment to optimize operating conditions. The following conclusion are drawn. 1. We got as following test results after the distribution of particles in the semiconductor wastewater, are made up of $1\~20{\mu}m$. Si, gold and Al in turn are contained in semiconductor wastewater. 2. Recovery rate is changeless under increasing recovery rate in operation. Though a value can be if pressure can be changed, the highest value of permeate rate is presented in 150 psi. 3. The AS-100(polysulpone) was selected as the most appropriate membranes for the treatment of semi-conductor wastewater to VSEP system. The fouling almost did not occur during this experiments. The analyses of treated water with VSEP system showed conductivity: 0.059,us/cm, TDS: 40mg/l, COD: 20mg/l, SS : 5mg/l, n-Hexane: 8.3mg/l. Comparing previous systems, operating expenses is decreased by more $50\%$.

Hexavalent Chromium Reduction by Bacteria from Tannery Effluent

  • Batool, Rida;Yrjala, Kim;Hasnain, Shahida
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권4호
    • /
    • pp.547-554
    • /
    • 2012
  • Chromium is generated from several industrial processes. It occurs in different oxidation states, but Cr(III) and Cr(VI) are the most common ones. Cr(VI) is a toxic, soluble environmental contaminant. Some bacteria are able to reduce hexavalent chromium to the insoluble and less toxic Cr(III), and thus chromate bioremediation is of considerable interest. An indigenous chromium-reducing bacterial strain, Rb-2, isolated from a tannery water sample, was identified as Ochrobactrum intermedium, on the basis of 16S rRNA gene sequencing. The influence of factors like temperature of incubation, initial concentration of Cr, mobility of bacteria, and different carbon sources were studied to test the ability of the bacterium to reduce Cr(VI) under variable environmental conditions. The ability of the bacterial strain to reduce hexavalent chromium in artificial and industrial sewage water was evaluated. It was observed that the mechanism of resistance to metal was not due to the change in the permeability barrier of the cell membrane, and the enzyme activity was found to be inductive. Intracellular reduction of Cr(VI) was proven by reductase assay using cell-free extract. Scanning electron microscopy revealed chromium precipitates on bacterial cell surfaces, and transmission electron microscopy showed the outer as well as inner distribution of Cr(VI). This bacterial strain can be useful for Cr(VI) detoxification under a wide range of environmental conditions.

고 에너지 양성자 가속기에서 생성되는 2차 방사선의 효과적인 차폐에 관한 연구 (Study on Effective Shielding of Secondary Radiation Generated by High Energy Proton Accelerator)

  • 배상일;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.383-388
    • /
    • 2020
  • High-energy proton accelerators continue to be increasingly used in medical, research and industrial settings. However, due to the high energy of protons, a large number of secondary radiation occurs. Among them, neutrons are accompanied by difficulties of shielding due to various energy distribution and permeability. So In this study, we propose a shielding method that can shield neutrons most efficiently by using multiple-shielding material used as a decelerating agent or absorbent as well as a single concrete shielding. The flux of secondary neutrons showed a greater decrease in the flux rate when heavy concrete was used than in the case of ordinary concrete, and the maximum flux reduction was observed at the front position when using multiple shields. Multiple shielding can increase shielding efficiency more than single shielding however, As the thickness of the multiple shielding materials increased, the decline in flux was saturated. The mixture material showed higher shielding results than the polyethylene when using boron carbonate.