• 제목/요약/키워드: permanent.

검색결과 6,712건 처리시간 0.032초

염색모발에서 퍼머시술시 퍼머 1제와 앰플의 혼합사용에 대한 효과 (A Study of Effects with Using After Mixing Ample and Permanent Solvent During Permanent Wave Operating, of Dyod Hairs)

  • 이은경;최정숙
    • 한국패션뷰티학회지
    • /
    • 제3권3호
    • /
    • pp.56-63
    • /
    • 2005
  • In the study of permanent waving method after mixing ample and permanent wave solvent in permanent wave the dyed humans hair are as follows; First, Permanent waving method after mixing ample and permanent wave solvent is that the better effective way in permanent wave the dyed humans hair because permanent waving cycle is constant and hair cuticle is glossy. Second, This study is not interpret in permanent wave dyed humans hair that tensile strength is effect of permanent waving method after mixing ample and permanent wave solvent. A extension degree is effect of permanent waving method after mixing ample and permanent wave solvent use indifferent ample treatment method. Third, Hair cuticle damages are a little permanent waving method after mixing ample and permanent wave solvent in permanent wave dyed humans hair.

  • PDF

흡수촉진제를 이용한 펌제의 웨이브 효율 증가 및 모발손상 억제 (Increase of Permanent Wave Efficacy and Decrease of Hair Damage by using Enhancer of Permanent Wave Lotion)

  • 송희라;박명희
    • 복식
    • /
    • 제56권4호
    • /
    • pp.124-133
    • /
    • 2006
  • Human hair could be damaged by various physicochemical conditions and treatment. Permanent and decoloring treatment were the most serious factor on hair damage. The new permanent wave lotion containing Permeation enhancers such as Cremophor EL, Transcutol and propylene glycol based on cysteine permanent wave lotion were prepared. Efficiency of permanent wave and hair damage following pH of permanent wave lotion and addition of permeation enhancer were investigated. PH of solution, wave efficiency, loss of protein from hair, morphology of hair by SEM and solubility of alkaline solution were evaluated. The addition of Cremophor EL and Transcutol with ethanol increased permanent wave efficacy and decreased hair damage effectively. They diminished permanent wave lotion's pH and augmented permanent wave lotion's penetration compare to cysteine permanent wave lotion. new permanent wave lotion containing permeation enhancers such as Cremophor EL could be a good candidate for a new permanent wave lotion.

병렬유전 알고리즘을 이용한 영구자석형 액추에이터의 최적설계 (Optimal Design of Permanent Magnet Actuator Using Parallel Genetic Algorithm)

  • 김중경;이철균;김한균;한성진
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.40-45
    • /
    • 2008
  • This paper presents an optimal design of a permanent magnet actuator(PMA) using a parallel genetic algorithm. Dynamic characteristics of permanent magnet actuator model are analyzed by coupled electromagnetic-mechanical finite element method. Dynamic characteristics of PMA such as holding force, operating time, and peak current are obtained by no load test and compared with the analyzed results by coupled finite element method. The permanent magnet actuator model is optimized using a parallel genetic algorithm. Some design parameters of vertical length of permanent magnet, horizontal length of plunger, and depth of permanent magnet actuator are predefined for an optimal design of permanent magnet actuator model. Furthermore dynamic characteristics of the optimized permanent magnet actuator model are analyzed by coupled finite element method. A displacement of plunger, flowing current of the coil, force of plunger, and velocity of plunger of the optimized permanent magnet actuator model are compared with the results of a primary permanent magnet actuator model.

Fault Diagnosis Method of Permanent Magnet Synchronous Motor for Electrical Vehicle

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.413-420
    • /
    • 2016
  • The permanent magnet synchronous motor has high efficiency driving performance and high power density output characteristics compared with other motors. In addition, it has good regenerative operation characteristics during braking and deceleration driving condition. For this reason, permanent magnet synchronous motor is generally applied as a power train motor for electrical vehicle. In permanent magnet synchronous motor, the most probable causes of fault are demagnetization of rotor's permanent magnet and short of stator winding turn. Therefore, the demagnetization fault of permanent magnet and turn fault of stator winding should be detected quickly to reduce the risk of accident and to prevent the progress of breakdown of power train system. In this paper, the fault diagnosis method using high frequency low voltage injection was suggested to diagnose the demagnetization fault of rotor permanent magnet and the turn fault of stator winding. The proposed fault diagnosis method can be used to check the faults of permanent magnet synchronous motor during system check-up process at vehicle starting and idling stop mode. The feasibility and usefulness of the proposed method were verified by the finite element analysis.

Design and Analysis of a Permanent-Magnet-Assisted Switched Reluctance Motor

  • Hwang, Hongsik;Hur, Jin;Lee, Cheewoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2209-2217
    • /
    • 2014
  • A permanent-magnet-assisted switched reluctance motor (SRM) having small excitation poles, where phase coils are concentrically wound on the poles and thin permanent magnets are inserted inside the poles, is proposed in this paper. The insertion of permanent magnets into the stator excitation poles has a significant influence on positive torque improvement leading to a boost in efficiency. Three key design parameters such as the thickness of permanent magnets, space between two adjacent permanent magnets, and the width of stator excitation poles are determined during a design procedure in terms of the enhancement of positive torque. Step-by-step design modification and a comparison between the proposed permanent-magnet-assisted SRM and no-permanent-magnet SRM have been conducted by means of static torque comparison along with dynamic performance. The first prototype from steel laminations up to its physical assembly has been constructed.

A Torque Compensation Method Considering Temperature Variation of SPMSM

  • Jung, Tae-Uk;Park, Chang-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.160-167
    • /
    • 2018
  • This paper analyzed the effect of temperature on the permanent magnet flux and output torque. The major parameter which will impact the torque control accuracy of a surface mounted permanent magnet motor is the variation of the permanent magnet temperature. In addition, the temperature variation of the permanent magnet will also influence the maximum torque per ampere of the motor. To analyze the effect of temperature on the permanent magnet, the rotor of the motor was directly heated to measure the temperature and the permanent magnet flux was measured. As a result, the output torque of the motor decreases as the temperature of the rotor permanent magnet increases. Therefore, this paper proposes a technique to compensate the phase current of the motor by estimating permanent magnet flux, and it is proved through theoretical basis and several experiments.

비탈형 영구거푸집의 현장 적용을 위한 실험적 연구 (An Experimental study on field application of Permanent form)

  • 정근호;김우재;이영도;정재영;정상진
    • 한국건축시공학회지
    • /
    • 제1권1호
    • /
    • pp.143-150
    • /
    • 2001
  • Permanent-Form is one of system forms for reducing human labor, work costs, oscillation, noise, construction wastes and so on. Permanent-Form is made from precast method in facilities, and carried in construction site to assemble with no demolding. The biggest expense to produce permanent-Form is about manufacturing mold. This papers about structural efficiency evaluation, construction efficiency test. The result of this study is below. (1) In the compressive strength test of column. Fly ash specimen and polymer specimen's strength developed as each 8%, 14% to comparison with standard specimen. The reason of this result from form section area increase and form's reinforcing bar (2) The Degree of column crack in permanent form is lower than another one's The glass fiber's fiber reinforcement effect brings like this. (3) In the flexural load test of beam, the early crack load and maximum load of permanent form use specimen showed 20% higher than standard specimen's. (4) In field application experiment, an constructional error is satisfied with the allowable margin of error, $\pm$5mm (5) When the concrete is placed into the form inside, The transformation degree of permanent form is lower than plywood form's. (6) The concrete packing ability of permanent form is satisfactory. (7) The bonding strength of permanent form shows enough strength - 6kgf/$\textrm{cm}^2$.

  • PDF

퍼머넌트 웨이브 시술방법에 따른 모발의 물리적·역학적 특성 변화 (The Change of Hair Physical and Mechanical Properties according to Permanent Wave Treatment Method)

  • 유태순;김정해;정연
    • 한국의류산업학회지
    • /
    • 제8권4호
    • /
    • pp.441-448
    • /
    • 2006
  • This research is the hair damage as treating a permanent wave before and after that is compared and analyzed the change of physical and mechanical properties. This is the survey of women's hair in 20 years old. On the basis of this we would like to analyze a extend of hair damage. Also, we would to show a basic data for hair damage prevention and hair improvement to keep the beautiful and healthy hair. The conclusion is as follow. : The swelling degree after the treatment was found to be greater than before permanent wave treatment. For the formational characteristics wave, untreated hair certainly had more elastic S curl wave than damaged hair in all the permanent wave treatments, and damaged hair and extremely damaged hair had less elasticity and had saggy S curl wave. The protein permanent and soft permanent wave had thicker, gorgeous, and better elastic wave than the regular permanent wave and direct heating permanent wave in all the hair condition. As the degree of damage on hair got greater, the tensile strength dramatically decreased and as the degree of damage got greater, the elongation was great as well. For treatment method, direct heating permanent wave showed the greatest effect, causing the most damage.

Employment Status Change and New-Onset Depressive Symptoms in Permanent Waged Workers

  • Kim, Hyung Doo;Park, Shin-Goo
    • Safety and Health at Work
    • /
    • 제12권1호
    • /
    • pp.108-113
    • /
    • 2021
  • Background: This study aimed to investigate the relationship between changes in employment status and new-onset depressive symptoms through a one-year follow-up of permanent waged workers. Methods: We analyzed the open-source data from the Korea Welfare Panel Study. Using the 2017 data, we selected 2,314 permanent waged workers aged 19 to 59 years without depressive symptoms as a base group. The final analysis targeted 2,073 workers who were followed up in 2018. In 2018, there were five categories of employment status for workers who were followed up: permanent, precarious, unemployed, self-employed, and economically inactive. Multiple logistic regression was used to determine the association between employment status change and new-onset depressive symptoms. Results: Adjusted multiple logistic regression analysis showed that among male workers, workers who went from permanent status to being unemployed (odds ratio: 4.50, 95% confidence interval: 1.19 to 17.06) and from permanent status to being precarious workers (odds ratio: 3.15, 95% confidence interval: 1.30 to 7.65) had significantly high levels of new-onset depressive symptoms compared with those who retained their permanent employment status. There were no significant increases in new-onset depressive symptoms of male workers who went from permanent status to being self-employed or economically inactive. On the other hand, no significant differences were found among female workers. Conclusion: Our study suggests that the change of employment status to precarious workers or unemployment can cause new-onset depressive symptoms in male permanent waged workers.

단상 유도동기 전동기(LSPM)의 과도 특성에 관한 연구 (A study on the transient characteristics in Single-phase Line-start Permanent Magnet)

  • 정대성;이주;이철직
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.631-632
    • /
    • 2006
  • This paper is written by research for the transient characteristics of the Single-phase Line-start permanent Magnet. The Single-phase Line-start permanent Magnet is most likely to substitute for Single-phase Induction Motor which is used about many appliance currently, because that has good points. For example, It has a Line-start of ability and a High-efficiency. And it need not power convergence device. The rotor of The Single-phase Line-start permanent Magnet has cage-bar with permanent magnet. This motor is started by cage-bar. When it entered synchronous condition, the rotor is rotated by the permanent magnet. But the design of the permanent magnet is very important, because the breaking torque of the permanent magnet interrupt to start a rotor. Finally, if Flux Barrier is not concerned, we do not get result of our object. Therefore this thesis is concerned about Flux Barrier.

  • PDF