• Title/Summary/Keyword: permanent setting

Search Result 54, Processing Time 0.028 seconds

Performance Testing of the Permanent Magnet Generator and Grid Inverter (영구자석형 발전기와 계통연계형 인버터의 성능실험)

  • Kim, Hyoung-Gil;Kim, Chul-Ho;Seo, Young-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.679-680
    • /
    • 2008
  • Most of the small wind turbines are set as the stand alone type in the area where the access to the grid is difficult and compulsorily uses the battery. Depending on the volume of the battery, securing of the space necessary, and has the shortcoming of replacing the battery periodically due to it's limited working life span. Recently, setting up in the vicinity of the city area is increasing and the trend of using the Grid inverter instead of battery is also increasing. This thesis is aiming mainly analyzing the characteristics of the output power of the Prototype Permanent Magnet Generator(PMG) and the Grid-Inverter and to verify through the theoretical study and tests. Tested the characteristics of the output power of the PMG through the stage 1-2 and at the stage 3 connected the output of the PMG to the Inverter and tested the characteristics of the Inverter. And at the stage 4, the maximum output power is confirmed by the continuous running test of the PMG.

  • PDF

A new sensorless speed control method for permanent magnet synchronous motor using direct torque control (직접토크제어를 이용한 영구자석 동기전동기의 새로운 센서리스 속도제어)

  • Oh, Sae-Gin;Kim, Jong-Su;Kim, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.653-658
    • /
    • 2013
  • This paper describes a new sensorless speed control method for permanent magnet synchronous motor(PMSM) using direct torque control(DTC). The direct torque control offers fast torque response, lesser hardware and processing costs as compared to vector controlled drives. In this paper the current error compensation technique is applied for sensorless speed control of synchronous motor. Through this method, the controlled stator voltage is applied to the synchronous motor so that the error between stator currents of the mathematical model and the actual motor can be forced to decay to zero as time proceeds and therefore, the motor speed approaches to the setting value. Especially, any PI controllers are not necessary in this control method. The simulation results indicate good speed and load responses from the low speed range to the high.

An Experimental Study for Flexural Failure Behavior of Composite Beam with Cast-in-place High Strength Concrete and GFRP Plank Using As a Permanent Formwork and Tensile Reinforcement (유리섬유강화폴리머 판을 영구거푸집 및 인장 보강재로 활용한 현장타설 고강도콘크리트 합성보의 휨 파괴거동에 관한 실험적 연구)

  • Um, Chan Hee;Yoo, Seung Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1015-1024
    • /
    • 2015
  • An experiment of composite beam was performed which utilized glass fiber reinforced polymer (GFRP) plank as the permanent formwork with cast-in-place high strength concrete. This research analyzed the flexural failure behavior of composite beam by setting the sand coated at GFRP bottom surface, the perforation and interval of the GFRP plank web, and the width of the top flange as the experimental variables. As a result of the experiments for effectiveness of sand attachment in case of not perforated web, approximately 43% higher ultimate load value was obtained when the sand was coated than not coated case. For effectiveness of perforation and interval of gap, approximately 23% higher maximum load value was seen when interval of the perforation gap was 3 times and the fine aggregate was not coated, and approximately 11% higher value was observed when the perforation gap was 5 times on the coated specimen. For effectiveness of top flange breadth, the ultimate load value was approximately 12% higher in case of 20mm than 40mm width.

Corrective Control of Asynchronous Sequential Circuits with Faults from Total Ionizing Dose Effects in Space (총이온화선량에 의한 고장이 존재하는 비동기 순차 회로의 교정 제어)

  • Yang, Jung-Min;Kwak, Seong-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.11
    • /
    • pp.1125-1131
    • /
    • 2011
  • This paper presents a control theoretic approach to realizing fault tolerance in asynchronous sequential circuits. The considered asynchronous circuit is assumed to work in space environment and is subject to faults caused by total ionizing dose (TID) effects. In our setting, TID effects cause permanent changes in state transition characteristics of the asynchronous circuit. Under a certain condition of reachability redundancy, it is possible to design a corrective controller so that the closed-loop system can maintain the normal behavior despite occurrences of TID faults. As a case study, the proposed control scheme is applied to an asynchronous arbiter implemented in FPGA.

Omni-directional Mobile Robot for 2D Translation and Rotation of a Puppet using Magnet (줄 인형의 2차원 이동 및 회전을 위한 자석기반 전 방향 로봇시스템)

  • Kim, Byeong-Yeol;Han, Young-Jun;Hahn, Hun-Soo
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.326-331
    • /
    • 2010
  • Marionette controlling robot has a problem that generates interference in rotation and intersection, therefore, the research on the independent shifter to move freely on the stage is required. Connecting omni-directional mobile robot with marionette controlling robot can solve this problem. Omni-directional mobile robot makes itself rotate and translate in 2D plane freely. Magnetic device is used to connect the moving part with the control part of the robot to minimize the intereference generated by the movement of robot. When robot moves, it can move to all directions with the suitalbe setting of banlance power. The moment of inertia is minimized by dividing the robot to the upper and lower parts in the marionette performance stage. Rotation and interference problem of independent omni-wheel Robot can be solved by using the permanent magnet. The efficiency and safety of the marionette controlling robot is proved by the experiment.

Design of Braille cell Setting Actuators for the Application in the Braille Mouse Concept

  • Nobels, Tiene;Allemeersch, Frank;Hameyer, Kay
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.1
    • /
    • pp.12-19
    • /
    • 2004
  • Refreshable Braille displays have already been developed in the past, but they remain quite bulky and expensive. Small displays contain only a single or a few Braille cells, with pins pushing into the fingertips. However, they are not as successful as larger displays because the skin is more sensitive to lateral movement than to orthogonal pressure. This, paper presents the design of linear electromagnetic actuators, which allows a considerable reduction in size and cost for such refreshable Braille displays. Different actuator concepts are compared. A new actuator is proposed and optimised by means of finite element simulations, which are verified with measurements on a prototype.

Physical Properties of Nylon Textured Yarn according to False Twist Texturing Parameters (II) - Effect of Disk/Yarn and Temperature - (가연조건에 따른 나일론 섬유의 물성 (II) - Disk/Yarn과 온도의 영향 -)

  • Hu, Jong-Tea
    • Textile Coloration and Finishing
    • /
    • v.20 no.1
    • /
    • pp.36-43
    • /
    • 2008
  • False twist texturing uses the thermoplastic property of synthetic yarn and produces a bulk and a stretch by giving the filament a permanent crimp. This study investigated the effects of false twist texturing parameters, disk/yarn(D/Y) and heater temperature, on the physical properties of nylon textured yarn. D/Y was a primary determinant of twist numbers of filaments and was proportionally increased with the twist numbers of filaments, resulting in an increase of crimp rigidity of the textured yarn. Heater temperature, a determinant of the heat setting of transformed filaments, was proportionally increased with the increase of crimp rigidity. Nylon 6 was partially melted at $190^{\circ}C$. This study consequently suggested the optimal parameters of nylon 6 85d/68f full-dull POY.

A Study of Stand Alone Small Wind Turbine Systems (독립형 소형 풍력발전 시스템에 관한 연구)

  • Kim, Hyoung-Gii;Kong, Jeong-Sik;Seo, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1005-1007
    • /
    • 2005
  • Small wind turbines are becoming a viable technology option to supply electricity to landowners. These systems provide energy security, product relatively no environmental harm, and in an appropriate setting can be quite cost-competitive with traditional electricity options. This paper is dealing with the methods how to overcome such inconvenience and with the analysis of characteristic and a field test with a prototype of the stand alone wind turbine was performed. The method applies to small systems, equipped with a coreless axial-flux permanent magnet(AFPM) generator in the turbine, a dc-dc converter and batteries. The analysis concentrates on the effect of the load on the power-wind speed curve of the turbine. The system is designed for direct driven, coupled with turbine and generator with a rated power of, 3kW.

  • PDF

Non-Permanent Transcatheter Proximal Renal Artery Embolization for a Grade 5 Renal Injury with Delayed Recanalization and Preserved Renal Parenchymal Enhancement

  • Jairam, Abhishek;King, Bradley;Berman, Zachary;Rivera-Sanfeliz, Gerant
    • Journal of Trauma and Injury
    • /
    • v.34 no.3
    • /
    • pp.198-202
    • /
    • 2021
  • Super-selective renal artery embolization is an increasingly popular technique for the management of traumatic, low-grade renal trauma. When performed in distal arterial branches, this intervention enables tissue preservation and arrest of hemorrhage, but it may not be practical in cases of multifocal, high-grade renal injuries. In such cases, surgical nephrectomy remains the more common treatment modality to ensure hemodynamic control. We present the unique case of a patient who presented in hemorrhagic shock following a major trauma that resulted in a grade 5 renal injury treated with complete renal artery embolization using Gelfoam, resulting in hemodynamic stabilization. Interestingly, imaging 1 month after embolization revealed residual enhancement of the inferior pole of the kidney, suggesting reconstitution of flow and partial renal salvage. Ultimately, transcatheter "nephrectomy" with careful selection of a temporary embolic agent may serve as a safe and efficient alternative to surgical nephrectomy with the added possibility of preserving partial renal perfusion and function in the emergent setting.

An Experimental Study for Flexure/Shear Failure Behavior of Composite Beam with GFRP Plank Used As a Permanent Formwork and Cast-in-place High Strength Concrete (영구거푸집으로 사용한 유리섬유 FRP 판과 현장타설 고강도콘크리트로 이루어진 합성보의 휨/전단파괴거동에 관한 실험적 연구)

  • Yoo, Seung-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4245-4252
    • /
    • 2015
  • In this study, an experiment which utilized glass fiber reinforced polymer(GFRP) plank as the permanent formwork of cast-in-place high strength concrete structures was performed. The GFRP plank currently being produced has smooth surface so that it causes problems in behavior with concrete. Therefore, this research analyzed the flexure/shear failure behavior of composite beams, which used GFRP plank as its permanent formwork and has short shear span ratio, by setting the sand coated at GFRP bottom surface, the perforation and interval of the GFRP plank web, and the width of the top flange as the experimental variables. As a result of the experiments for effectiveness of sand attachment in case of not perforated web, approximately 47% higher ultimate load value was obtained when the sand was coated than not coated case and bending/shear failure mode was observed. For effectiveness of perforation and interval of gap, approximately 24% higher maximum load value was seen when interval of the perforation gap was short and the fine aggregate was not coated, and approximately 25% lower value was observed when the perforation gap was not dense on the coated specimen. For effectiveness of top flange breadth, the ultimate load value was approximately 17% higher in case of 40mm than 20mm width.