• 제목/요약/키워드: permanent set

검색결과 206건 처리시간 0.031초

실시간 다색광전달함수의 측정 및 응용연구 (Real-time Measurement of Polychromatic Optical Transfer Function and Its Applications)

  • Song Jong Seop;Lee Yun U;Jo Jae Heung
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.26-27
    • /
    • 2003
  • A wide variety of devices and systems exist whose main function is to generate an image. These devices and systems are used for many different purposes and find applications in many different walks of life. We are all very familiar with some of these systems such as the photographic camera (that can produce a permanent record of a scene on sensitized sheet material) and the television set (that can receive a suitably coded electromagnetic signal broadcast through space and convert it into an image). (omitted)

  • PDF

Orthopantomograph에 의(依)한 혼합치열상(混合齒列像)의 해석(解析)에 관(關)한 연구(硏究) (A STUDY ON AN INTERPRETATION OF THE ORTHOPANTOMOGRAPH IN THE MIXED DENTITION)

  • 김광원
    • 대한치과교정학회지
    • /
    • 제12권2호
    • /
    • pp.145-154
    • /
    • 1982
  • Plaster models were constructed and orthopantomographs were taken for 86 male and 70 female primary school pupils, whose upper and lower permanent 4 incisors and 1st molars were completely erupted without crowding; whose deciduous canines and molars were found almost uniformly even without any visible tooth fractures, dental caries or restorations on proximal surfaces of the teeth. Certain reference points on the orthophantomograph were set up and measured and the values were compared with actual or predicted values from the models. The following results were obtained: 1. In regards to available space, the values from the orthopantomograph were greater than the values from the models by a mean of 3.24% on the upper and 10.06% on the lower for males; 3.05% on the upper and 10.01% on the lower for females. 2. In regards to total mesiodistal widths of permanent canine, 1st and 2nd premolars, the values from the orthopantomograph were greater than the presumed values based on the size of lower permanent 4 incisors from the models by a mean of 18.50% on the upper and 24.09% on the lower for males; 14.54 on the upper and 20.51% on the lower for females. 3. Comparing the magnified values of total mesiodistal widths of permanent canine, 1st and 2nd premolars with those of available space, the regression constants of regression equation (Y = a + bX) between them were a=3.2336, b=0.6533 on the upper and a=5.0138, b=0.3290 on the lower for males; a=2.5994, b=0.6521 on the upper and a=3.0113, b=0.6586 on the lower for females. 4. The correlation coefficients between the magnified values of available space and permanent canine, 1st and 2nd premolars were moderately positive as 0.6474 in the upper and 0.505 on the lower for males; 0.6493 on the upper and 0.6183 on the lower for females. 5. In regards to magnified values of the available space from the orthopantomographs there were no significant difference between sexes, (P>0.05) but of the total mesiodistal widths of permanent canine, 1st and 2nd premolars, a significant difference between sexes was found.(p<0.01).

  • PDF

치과 방사선 발생기의 성능평가에 관한 연구 (Study on Performance Evaluation of Dental X-ray Equipment)

  • 정재은;정재호;강희두;이종웅;나극환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

영구자석동기발전기 풍력시스템의 하드웨어 시뮬레이터 개발 (Development of Hardware Simulator for PMSG Wind Power System)

  • 이두영;윤동진;정종규;양승철;한병문;송승호
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.951-958
    • /
    • 2008
  • This paper describes development of hardware simulator for the PMSG wind power system, which was designed considering wind characteristic, blade characteristic and blade inertia compensation. The simulator consists of three major parts, such as wind turbine model using induction motor, PMSG generator, converter-inverter set. and control system. The turbine simulator generates torque and speed signals for a specific wind turbine with respect to given wind speed. This torque and speed signals are scaled down to fit the input of 2kW PMSG. The PMSG-side converter operates to track the maximum power point, and the grid-side inverter controls the active and reactive power supplied to the grid. The operational feasibility was verified by computer simulations with PSCAD/EMTDC, and the implementation feasibility was confirmed through experimental works with a hardware set-up.

Swarm Group Mobility Model for Ad Hoc Wireless Networks

  • Kim, Dong-Soo S.;Hwang, Seok-K.
    • Journal of Ubiquitous Convergence Technology
    • /
    • 제1권1호
    • /
    • pp.53-59
    • /
    • 2007
  • This paper proposes a new group mobility model for wireless communication. The mobility model considers the psychological and sociological behavior of each node and the perception of other nodes for describing interactions among a set of nodes. The model assumes no permanent membership of a group, capable of capturing natural behaviors as fork and join. It emulates a cooperative movement pattern observed in mobile ad hoc networks of military operation and campus, in which a set of mobile stations accomplish a cooperative motion affected by the individual behavior as well as a group behavior. The model also employs a physic model to avoid a sudden stopping and a sharping turning.

  • PDF

풍속계와 Motor-Generator를 이용한 영구자석동기발전기 풍력발전시스템 하드웨어 시뮬레이터 개발 (Development of hardware simulator for PMSG wind power system composed of anemometer and motor-generator set)

  • 정종규;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.248-249
    • /
    • 2010
  • This paper describes development of hardware simulator for the PMSG(Permanent Magnet Synchronous Generator) wind power system, which was designed using real wind data. The simulator consists of a realistic wind turbine model using anemometer, vector drive, induction motor. The turbine simulator generates torque and speed signals for a specific wind turbine with respect to given wind speed. This torque and speed signals are scaled down to fit the input of 3kW PMSG. The PMSG-side converter operates to track the maximum power point and the grid-side inverter controls the active and reactive power supplied to the grid. The operational feasibility was first verified by computer simulations with PSCAD/EMTDC. The feasibility of real system implementation was confirmed through experimental works with a hardware set-up.

  • PDF

Genetic Parameters and Annual Trends for Birth and Weaning Weights of a Northeastern Thai Indigenous Cattle Line

  • Intaratham, W.;Koonawootrittriron, S.;Sopannarath, P.;Graser, H.-U.;Tumwasorn, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권4호
    • /
    • pp.478-483
    • /
    • 2008
  • Records of a Northeastern Thai indigenous cattle line population were used to estimate genetic parameters and annual trends for calf weights. The data set comprised records of 1,922 and 1,489 animals for birth and weaning weight, respectively born from 1993 to 2004. A bivariate analysis was carried out for variance and covariance components estimations using average information restricted maximum likelihood procedure. Average estimated breeding value and maternal breeding value of the animals born in 1993 were set to zero as a base group. Genetic trends of each trait were calculated by regressing average estimated breeding values and maternal breeding values on birth year of calves. Phenotypic trends for each trait were calculated by regressing the yearly adjusted weight on birth year of calves. The results revealed that the estimate of direct heritability, maternal heritability and maternal permanent environmental variance as a proportion of phenotypic variance for birth and weaning weight was 0.40, 0.14 and 0.04; 0.27, 0.05 and 0.23, respectively. Direct heritability was moderately heritable and genetic improvement through selection can be achieved. The estimate of phenotypic, direct genetic, maternal genetic and maternal permanent environmental correlation between birth and weaning weight was 0.48, 0.65, 0.98 and 0.73, respectively. The phenotypic trend, genetic trends of estimated breeding value and maternal breeding value for birth weight was 0.18, 0.04 and 0.01 kg/year, respectively. The phenotypic trend, genetic trends of estimated breeding value and maternal breeding value for weaning weight was -1.36, 0.32 and 0.03 kg/year, respectively. As maternal genetic effect was considerably less important than direct genetic effect, selection for improved weaning weight of this Northeastern Thai indigenous cattle line can place more emphasis on the direct genetic effect.

TIME-DEPENDENT DEFORMATION OF POLYMER-BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS

  • Pae Ahran;Jeong Mi-Sook;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.717-726
    • /
    • 2005
  • Statement of problem. One of the common problems of provisional crown and fixed partial denture materials is that when they are subjected to constant loads for a long period of time, they exhibit a dimensional change (creep). Purpose. The aim of this study was to investigate the viscoelastic behaviour of polymer-based provisional crown and fixed partial denture materials with time at constant compressive load. Material and methods. Three dimethacrylate-based materials (Protemp 3 Garant, Temphase, Luxatemp) and one monomethacrylate-based material (Trim) were selected. Dimensional changes of the specimens were recorded by a LVDT to evaluate their viscoelastic behavior and creep strain. For all specimens, two loading procedures were used. At first, static compressive stress of 4 MPa was applied for 30 minutes and followed by 1 hour of strain recovery. Then, after 24 hours of water storage, the specimens were loaded again. The creep values between materials were statistically analyzed using one-way ANOVA and multiple comparison $Scheff\acute{e}$ test. Independent samples t-test was also used to identify the difference of creep strain between first and secondary loading conditions at the significance level of 0.05. Results. Following application of the first loading, Trim showed the highest maximum creep strain (32.7%) followed by Luxatemp, Protemp 3 Garant and Temphase, with values of 3.78%, 2.86% and 1.77%, respectively. Trim was significantly different from other materials (P<0.05), while there were no significant differences among Luxatemp, Protemp 3 Garant and Temphase (P>0.05). The highest recovery and permanent set of Trim, were significantly different from those of others (P<0.05). At the secondary loading of the dimethacrylate-based materials, creep deformation, recovery and permanent set decreased and the percentage of recovery increased, while in Trim, all values of the measurements increased. This result showed that the secondary loading at 24 hours produced a significant creep magnitude. Conclusion. The dimethacrylate-based provisional crown and fixed partial denture materials showed significantly higher creep resistance and lower deformation than the monomethacrylate-based material. Thus, monomethacrylate-based materials should not be used in long-term stress-bearing situations.

순차적 크리깅 근사모델을 이용한 LMTT 이동체의 구조최적설계 (Structural Optimization for LMTT-Mover Using Sequential Kriging Approximation Model)

  • 이권희;박형욱;한동섭;한근조
    • 한국항해항만학회지
    • /
    • 제30권1호
    • /
    • pp.105-111
    • /
    • 2006
  • LMTT는 항만 자동화를 위한 수평 이송이 가능하도록 설계된 셔틀카와 격자구조의 레일에 부착된 스테이터 모듈(stator module)로 구성된 PMLSM(Permanent Magnetic Linear Synchronous Motor)에 의해 구동된다. 본 연구에서는 순차적 표본방법에 기초하여 구성된 크리깅 근사모델을 이용하여 이동체의 구조최적설계를 수행하였다. 본 논문에서는 셀 요소로 유한요소 모델링된 이동체(mover)의 경량화 설계를 위하여 강도기준을 고려하고, 설계변수로는 가로빔, 세로빔, 휠 빔의 두께로 설정하였다. 순차적 크리깅모델에 의하여 구해진 최적해를 상용프로그램인 GENESIS를 이용하여 구해진 최적해와 비교, 검토하였다.

Rare earth coupling agent로 표면개질된 Oyster shell이 친환경 Bio-EPDM 발포체에 미치는 영향 연구 (A Study on the Effect of Oyster Shell Surfase Modified with Rare Earth Coupling Agent on Eco-Friendly Bio-EPDM Foam)

  • 서은호;임성욱;박경순;박은영
    • 한국염색가공학회지
    • /
    • 제33권4호
    • /
    • pp.317-326
    • /
    • 2021
  • In this study, we investigated for Bio-EPDM foam with oyster shell surface modified earth coupling agent. Experiments were carried out to confirm the bio-EPDM/Oyster shell foam applying content of earth coupling agent. The cure characterization were evaluated by measuring the mooney viscosity and oscillating disc rheometer (ODR). Mechanical properties such as hardness, tensile strength, elogation at break and tear strength were measured, and changes of mechanical properties were also evaluated after immersion in NaCl solution. In addition degree of volume change was measured after immersing the Bio-EPDM foam in NaCl solution and the low-temperature permanent compression set was evaluated at 4℃. To evaluate the low-temperature characteristics of Bio-EPDM/Oyster shell, the glass transition temperature was measured using Differential Scanning Calorimeter (DSC). As a result as the content of the earth coupling agent increased up to 3phr, the crosslinking density and mooney viscosity increased, and the mechanical properties and low-temperature permanent compression set improved, but from 4phr, it was rather decreased. The change in the glass transition temperature was insignificant, and the foam cell appeared to be uniform when the earth coupling agent was applied.