• Title/Summary/Keyword: permanent pacemaker

Search Result 66, Processing Time 0.047 seconds

Permanent Pacemaker Lead Induced Severe Tricuspid Regurgitation in Patient Undergoing Multiple Valve Surgery

  • Lee, Jung Hee;Kim, Tae Ho;Kim, Wook Sung
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.129-133
    • /
    • 2015
  • Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.

Study on Recipients' Experience of Adapting to Permanent Pacemakers (영구적 인공심박동기 이식자의 적응 경험)

  • Han, Sun Hee;Kang, Jeong Hee
    • Journal of Korean Critical Care Nursing
    • /
    • v.11 no.3
    • /
    • pp.23-34
    • /
    • 2018
  • Purpose : This study develops a substantive theory on the recipients' experience of adapting to a permanent pacemaker. Method : The study used the grounded theory method developed by Strauss and Corbin (1998). The participants of the study were 13 adults who had received a permanent pacemaker during the previous year. The study addressed the research question "what is the experience of adaptation in people who had received permanent pacemakers?" From October 2016 to March 2017, data were collected from the participants through in-depth interviews. Results : The core category indicating the essence of the adaptation experience was shown to be "accepting the pacemaker as part of my body and living in line with it." Conclusions : In nursing practice, the results of this study will assist nurses in improving their communications with and developing guidelines or interventions for their clients who have received permanent pacemakers. In the field of nursing education, this study is expected to provide a framework to understand the experiences of future nurses and other healthcare workers working with permanent pacemaker recipients.

The Knowledge and Learning Needs of Patients with a Permanent Pacemaker (영구형 심박조율기 이식 환자의 지식과 교육요구도)

  • Yoo Yang-Sook;Lee Sun-Kyung;Cho Ok-Hee;Jeong Hye-Sun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.11 no.2
    • /
    • pp.148-155
    • /
    • 2004
  • Purpose: The purpose of this study was to examine the level of knowledge and learning needs of patients with a permanent pacemaker implantation. Methods: The participants were 86 patients with a permanent pacemaker implantation. Data were collected during April and May 2002 using a questionnaire survey on knowledge and level of learning need. The collected data were analyzed using the SAS program. Results: 1. The average knowledge score was 13.21. The knowledge level was significantly higher in participants under 50 years of age and for those with higher levels of education. The items with the highest knowledge score was 'permanent pacemaker needs regular check ups' and the lowest, 'a bath can be taken 1 month after stitches are removed'. 2. The total average score for learning needs was 60.78 and the mean item score was 3.04 as measured on a 4-point Likert scale. The item showing the highest learning need was 'electrical fields can affect the pacemaker's function and the lowest learning need was for sexual activity after permanent pacemaker implantation'. Conclusion: According to the above findings, it can be concluded that an intensive nursing education program should be developed for patients with a permanent pacemaker especially for those patients over 50 years of age and those with lower levels of education.

  • PDF

Effect of Providing Information on Anxiety, Knowledge and Compliance of Patients with a Permanent Pacemaker (정보제공이 영구형 심박조율기 이식환자의 불안, 지식 및 치료지시이행에 미치는 효과)

  • Lee, Sun Kyung;Yoo, Yang Sook
    • Korean Journal of Adult Nursing
    • /
    • v.17 no.3
    • /
    • pp.484-492
    • /
    • 2005
  • Purpose: This study was undertaken to identify the effect of providing information on anxiety, knowledge and compliance in permanent pacemaker patients. Method: A quasi experimental design with non-equivalent control group and non-synchronized design was used. The subjects of this study were 50 patients who had received permanent pacemaker implantation at a university hospital in Seoul. They were divided into an experimental group of 22 patients who received education and a control group of 28 patients. The education was composed of group education(twice) and individualized reinforcement education(once) using an education booklet. Results: Anxiety decreased in the experimental group. Knowledge significantly increased in the experimental group compared to that in the control group. Compliance significantly increased in the experimental group. Conclusion: It can be concluded that providing information is effective for reducing anxiety, increasing knowledge and improving compliance of the permanent pacemaker patients.

  • PDF

Thoracoscopic Patch Insulation for Phrenic Nerve Stimulation after Permanent Pacemaker Implantation

  • Kang, Yoonjin;Kim, Eung Rae;Kwak, Jae Gun;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.51 no.5
    • /
    • pp.363-366
    • /
    • 2018
  • One of the complications of permanent pacemaker implantation is unintended phrenic nerve stimulation. A 15-year-old boy with a permanent pacemaker presented with chest discomfort due to synchronous chest wall contraction with pacing beats. Even after reprogramming of the pacemaker, diaphragmatic stimulation persisted. Therefore, we performed thoracoscopic phrenic nerve insulation using a Gore-Tex patch to insulate the phrenic nerve from the wire. A minimally invasive approach using a thoracoscope is a feasible option for retractable phrenic nerve stimulation after pacemaker implantation.

Pacing Wire Removal Via a Right Atriotomy: A Patient with Infected Permanent Pacemaker and Who Previously Underwent CABG - A case report - (개심술을 통한 심박동기 와이어의 제거: 관상동맥 치환술을 받은 환자에서 심박동기 삽입 후 발생한 국소 감염의 치료 - 1예 보고 -)

  • Kim, Yun-Seok;Song, Hyun;Ryu, Yang-Gi;Jung, Sung-Ho
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.256-258
    • /
    • 2009
  • A 63-year-old man who had a permanent pacemaker placed 17 years ago presented to us with local inflammatory signs on his chest. The skin was opened to remove the permanent pacemaker. However, the pacing wire was not easily removed. So, the permanent pacemaker was removed from the chest with leaving the remnant wire inside. However, the local infection recurred because of the remnant wire. Right thoracotomy was performed and cardiopulmonary bypass was started. After total circulatory arrest, the right atrium was opened and the wire was completely removed.

Complicated Wound Infection Following Transvenous Endocardial Pacemaker (경정맥(經靜脈) 내적(內的) Pacemaker 이식후(移植後) 발생(發生)한 복잡한 감염합병증(感染合?症)의 1치험례(治驗例))

  • Lee, D.Y.;Yoon, Y.J.;Cho, B.K.;Hong, S.N.
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.265-270
    • /
    • 1976
  • Implantation of a permanent pacemaker is a widely accepted procedure for the patient with complete heart block.As a result of these device, the prognosis for patients with Adams-Stokes syndrome caused by complete A-V block and other cardiac arrhythmia have become much more optimistic. Permanent pacemaker implantation by means of a transvenous approach has made the operative risk much less and the procedure simpler. However, a number of complications have been reported in the literature regarding transvenous endocardial pacemaker implantation during the last a decade. The patient presented in this paper is a 26-year old girl who was implanted with a permanent pacemaker at 14 years of age because of a congenital A-V block. Following first exchange of pulse generator, the electrode (lead) was fractured, so that by the pulse generator, a change to the transvenous technique of implantation was made, After this, there were episodes of recurrent wound infection on three occasions, even though the site of pulse generator implantation was exchanged to the contralateral side of chest wall, massive doses of antibiotics were administered and sensitivity tests for coagulase positive staphylococcal infection were performed. Though there was no definite evidence of blood stream infection by blood culture, we decided not to use the transvenous technique and not to implant the pulse generator in the chest wall because the venous system and the entire anterior chest wall appeared to be diseased or contaminated by virulent pyogenic organisms. Finally this intractable systemic and local wound infection was successfully controlled by myocardial lead implantation via a subxiphoid approach and implantation of the pulse generator far down in the abdominal wall. The causes and routes of recurrent wound infection and possible blood born infection in this particular patient are still obscure. We strongly believe that myocardial pacemaker implantation is much safer than transvenous endocardial pacemaker implantation & myocardial pacemaker implantation is a definite method for controlling such an intractable wound infection. following transvenous pacemaker implantation.

  • PDF

Complications Following Permanent Transvenous Endocardial Pacemaker Implantation (Cardiac pacemaker implantation 의 합병증)

  • 왕영필
    • Journal of Chest Surgery
    • /
    • v.10 no.2
    • /
    • pp.219-225
    • /
    • 1977
  • Pacemaker therapy has been established as a routine procedure in a variety of disturbances of :cardiac rhythm. Cardiac pacing has greatly reduced the mortality rate in patients suffering from bradyarrhythmias complicated by Stokes-Adams attacks. However, in spite of the simplicity of the treatment and reliability of the devices available today, patients and physicians alike are invovled in a multitde of pacemaker specific problems. Clinical experience with permanent transvenous pacing during a 3 year period is presented. A total of 20 pacemaker operations were performed in 13 patients. The complications in our 20 pacemaker operations were headed by skin ulceration of 3 generator pockets and early dislocation of 3 electrodes. In an additional 2 patient, stimulation of diaphragm due to a position of electrode in the coronary sinus was noticed in one and battery failure of pulse generator was detected in the other. Literatures were reviewed.

  • PDF

Implantation of permanent pacemaker after open heart surgery (개심술후 영구적 인공심박조정기 장)

  • Jo, Beom-Gu;Park, Yeong-Sik;Lee, Jong-Guk
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.356-361
    • /
    • 1984
  • During the period from January 1982 to June 1984 we implanted permanent pacemakers in 18 patients who received open heart surgery at Yonsei University Hospital. 1.In 11 patients, open heart surgery was performed at Yonsei University Hospital and new surgical induced heart blocks were developed and implantations of permanent pacemaker were done. 2.Total 1035 open heart surgeries were done and implantations of pacemaker were performed in 11 cases. [1.06%]. After total correction of TOF [215 cases] implantations of pacemaker were done in 3 cases. [1.4%] Implantations of pacemaker were 0.37% after VSD repair, 0.78% after ASD repair, 5.9% after ECD repair, 0.48% after MVR and 2.0% after AVR. 3.Causes were complete A-V block, sick sinus syndrome and A-V dissociation. 4.Heart blocks were developed immediately after bypass stop in 8 patients. 5.Implantations of pacemaker were done at more than 2 weeks after open heart surgery. 6.Local anesthesia was done in adult and general anesthesia in infants. Locations of pulse generator were subxiphoid, subcostal & subclavian. Position of pulse generator was between subcutaneous fat layer and muscle layer. 7.Types of pulse generator were VVI, VDD and AAI. 8.The postoperative complications included infection, pacing failure, sensing failure and lead dislodgment.

  • PDF

A Case of Disappearing Symptoms Developed Repetitively in a Complete Atrioventricular Block Patient Implanted Bipolar Permanent Pacemaker After Converting It into Unipolar System (완전방실블록 환자에서 쌍극의 영구박동기를 이식후 반복 발생된 증상이 단극으로 전환후 증상이 소실된 예)

  • Kweon, Jun-Young;Choi, Kyo-Won;Sin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.181-185
    • /
    • 1994
  • Pacemaker malfunctions are secondary to alterations of the preset pacing rate, irregular pacing failure of sensing, failure of cardiac capture or depolarization, and various combinations of these events. A 76 years old male patient was admitted due to pacemaker malfunction. 2 years ago, he was diagnosed as complete atrioventricular block. And then bipolar permanent pacemaker was implanted. Since then syncopal attack developed repetitivly. 12 lead ECG and 24 hour holter moniter monitoring, revealed pacing and sensing failure, thus we converted bipolar system into unipolar system. Since then syncopal attack did not developed again.

  • PDF