• Title/Summary/Keyword: peripheral path

Search Result 26, Processing Time 0.034 seconds

Research on impulse purchase of live e-commerce platform users based on ELM model in China

  • Yu, Ying;Liu, Ziyang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.11
    • /
    • pp.295-304
    • /
    • 2022
  • The purpose of this study is to investigate the influencing factors and mechanism of the characteristics of the live broadcast e-commerce platform and the characteristics of the host on the impulse purchase intention of live broadcast viewers. Based on the ELM model, this study complements existing research content. This study adopts the form of questionnaire survey and conducts empirical analysis using SPSS, AMOS, Mplus and other analysis software for online live broadcast users. The results show that the characteristics of live broadcast platforms have a positive impact on consumers' flow experience and satisfaction; the personal characteristics of anchors have a positive impact on consumers' flow experience and satisfaction; consumers' flow experience and satisfaction have a positive impact on impulse Purchase intention has a positive impact, and flow experience and satisfaction have a mediating effect on the characteristics of the live broadcast platform and the personal characteristics of the host.

Ablative Outcomes of Various Energy Modes for No-Touch and Peripheral Tumor-Puncturing Radiofrequency Ablation: An Ex Vivo Simulation Study

  • Dong Ik Cha;Min Woo Lee;Kyoung Doo Song;Seong Eun Ko;Hyunchul Rhim
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.189-201
    • /
    • 2022
  • Objective: To compare the outcomes of radiofrequency ablation (RFA) using dual switching monopolar (DSM), switching bipolar (SB), and combined DSM + SB modes at two different interelectrode distances (25 and 20 mm) in an ex vivo study, which simulated ablation of a 2.5-cm virtual hepatic tumor. Materials and Methods: A total of 132 ablation zones were created (22 ablation zones for each protocol) using three separable clustered electrodes. The performances of the DSM, SB, and combined DSM + SB ablation modes were compared by evaluating the following parameters of the RFA zones at two interelectrode distances: shape (circularity), size (diameter and volume), peritumoral ablative margins, and percentages of the white zone at the midpoint of the two electrodes (ablative margin at midpoint, AMm) and in the electrode path (ablative margin at electrode path, AMe). Results: At both distances, circularity was the highest in the SB mode, followed by the DSM + SB mode, and was the lowest in the DSM mode. The circularity of the ablation zone showed a significant difference among the three energy groups (p < 0.001 and p = 0.002 for 25-mm and 20-mm, respectively). All size measurements, AMm, and AMe were the greatest in the DSM mode, followed by the DSM + SB mode, and the lowest were with the SB mode (all statistically significant). The white zone proportion in AMm and AMe were the greatest in the SB mode, followed by the DSM + SB mode and DSM in general. Conclusion: DSM and SB appear to be complementary in creating an ideal ablation zone. RFA with the SB mode can efficiently eradicate tumors and create a circular ablation zone, while DSM is required to create a sufficient ablative margin and a large ablation zone.

User-Oriented Controller Design for Multi-Axis Manipulators (다관절 머니퓰레이터의 사용자 중심 제어기 설계)

  • Son, HeonSuk;Kang, DaeHoon;Lee, JangMyung
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.3 no.2
    • /
    • pp.49-56
    • /
    • 2008
  • This paper proposes a PC-based open architecture controller for a multi-axis robotic manipulator. The designed controller can be applied for various multi-axes robotic manipulators since the motion controller is implemented on a PC with its peripheral devices. The accuracy of the controller based on the computed torque method has been measured with the dynamic model of manipulator. Since the controller is implemented in the PC-based architecture, it is free from the user circumstances and the operating environment. Dynamics of the manipulator have been compensated by the feed forward path in the inner loop and the resulting linear outer loop has been controlled by PD algorithm. Using the specialized language, it can be more efficient in programming and in driving of the multi-axis robot. Unlike the conventional controller that is used to control only a specific robot, this controller can be easily changed for various types of robots. This paper proposes a PC-based controller that has a simple architecture with its simple interface circuits than general commercial controllers. The maintenance and the performance of the controller can be easily improved for a specific robot. In fact, using a Samsung multi-axis robot, AT1, the controller performance and convenience of the PC-based controller have been verified by comparing to the commercial one.

  • PDF

분산 제어기 구조를 갖는 마스터 암의 기구학 설계 및 해석

  • Lee, Jangwook;Kim, Yoonsang;Lee, Sooyong;Kim, Munsang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.6
    • /
    • pp.532-539
    • /
    • 2001
  • In robot teleoperation, much research has been carried out to control the slave robot from remote site. One of the essential devices for robot teleoperation is the masterarm, which is a path command generating device worn on human arm. In this paper, a new masterarm based on human kinematics is proposed. Its controller is based on the distributed controller architecture composed of two controller parts: a host controller and a set of satellite controllers. Each satellite controller measures the corresponding joint angle, while the host controller performs forward and inverse kinematics calculation. This distributed controller architecture can make the data updating faster, which allows to implement real-time implementation. The host controller and the satellited controllers are networked via three-wire daisy-chained SPI(Serial Peripheral Interface) protocol, so this architecture makes the electrical wiring very simple, and enhances maintenance. Analytical method for finding three additional unknown joint angles is derived using only three measured angles for each shoulder and wrist, which makes th hardware implementation very simple by minimizing the required number of satellite controllers. Finally, the simulation and experiment results are given to demonstrate the usefulness and performance of the proposed masterarm.

  • PDF

Neurilemoma Localized in the Palmaris Longus Tendon with no Connection to the Major Nerve Trunk (주요 신경과의 연결이 없이 발생한 긴손바닥근의 신경초종)

  • Park, Jeong-Young;Jung, Sung-No;Sohn, Won-Il;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.498-500
    • /
    • 2011
  • Purpose: Neurilemoma is benign tumor of the nerve sheath which arises from Schwann cells. It is usually formed along the path of a peripheral nerve but is rarely separate from normal nerve fascicles. We experienced a patient with an isolated neurilemoma localized in the palmaris longus tendon with no connection to the major nerve trunk, which was in an unusual location and has never been reported. We report our case with the review of the literature. Methods: A 23-year-old female visited our clinic with mild pain on the mass at the flexor area of the right wrist which had been present for about one year. The physical examination revealed a $1{\times}1cm$ sized subcutaneous mass at the flexor area of the right wrist. Sonography and computed tomography showed an ovoid, superficial solid mass on the palmaris longus tendon. Upon surgical excision, a $1{\times}0.5cm$ sized mass attached to the palmaris longus tendon was found. The tumor had no connection with the median nerve and was detached easily from the palmaris longus tendon. Results: Histological examination demonstrated the mass to be a neurilemoma, which consists of spindle shaped cells with oval elongated nuclei arranged fascicles. No sensory dysfunction or evidence of recurrence was found during the 12 months of postoperative follow-up. Conclusion: We experienced a rare case of neurilemoma attached to the palmaris longus tendon with no connection to the major nerve trunk. We wish to emphasize its unusual location through our case and hope to expand our spectrum in exploring the upper extremity mass.

Interfacial Properties of Friction-Welded TiAl and SCM440 Alloys with Cu as Insert Metal (삽입금속 Cu를 이용한 TiAl 합금과 SCM440의 마찰용접 계면 특성)

  • Park, Sung-Hyun;Kim, Ki-Young;Park, Jong-Moon;Choi, In-Chul;Ito, Kazuhiro;Oh, Myung-Hoon
    • Korean Journal of Materials Research
    • /
    • v.29 no.4
    • /
    • pp.258-263
    • /
    • 2019
  • Since the directly bonded interface between TiAl alloy and SCM440 includes lots of cracks and generated intermetallic compounds(IMCs) such as TiC, FeTi, and $Fe_2Ti$, the interfacial strength can be significantly reduced. Therefore, in this study, Cu is selected as an insert metal to improve the lower tensile strength of the joint between TiAl alloy and SCM440 during friction welding. As a result, newly formed IMCs, such as $Cu_2TiAl$, CuTiAl, and $TiCu_2$, are found at the interface between TiAl alloy and Cu layer and the thickness of IMCs layers is found to vary with friction time. In addition, to determine the relationship between the thickness of the IMCs and the strength of the welded interfaces, a tensile test was performed using sub-size specimens obtained from the center to the peripheral region of the friction-welded interface. The results are discussed in terms of changes in the IMCs and the underlying deformation mechanism. Finally, it is found that the friction welding process needs to be idealized because IMCs generated between TiAl alloy and Cu act to not only increase the bonding strength but also form an easy path of fracture propagation.

Design of High-Speed Sense Amplifier for In-Memory Computing (인 메모리 컴퓨팅을 위한 고속 감지 증폭기 설계)

  • Na-Hyun Kim;Jeong-Beom Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.777-784
    • /
    • 2023
  • A sense amplifier is an essential peripheral circuit for designing a memory and is used to sense a small differential input signal and amplify it into digital signal. In this paper, a high-speed sense amplifier applicable to in-memory computing circuits is proposed. The proposed circuit reduces sense delay time through transistor Mtail that provides an additional discharge path and improves the circuit performance of the sense amplifier by applying m-GDI (: modified Gate Diffusion Input). Compared with previous structure, the sense delay time was reduced by 16.82%, the PDP(: Power Delay Product) by 17.23%, the EDP(: Energy Delay Product) by 31.1%. The proposed circuit was implemented using TSMC's 65nm CMOS process, while its feasibility was verified through SPECTRE simulation in this study.

Current Strategy in Endovascular Management for Below-the-Knee Arterial Lesions (무릎 밑 동맥의 혈관 내 치료의 최신 지견)

  • Kyosoo Hwang;Sang Woo Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.541-550
    • /
    • 2021
  • The below-the-knee arterial tree is the thinnest of all the leg vessels and is an important path for blood flow to the foot. Hence, lesions including stenosis, especially obstruction, may lead to critical limb ischemia which represents the most severe clinical manifestation of peripheral arterial disease. It is characterized by the presence of ischemic rest pain, ischemic lesions, or gangrene attributable to the objectively proven arterial occlusive disease. Typically, the atherosclerotic disease process involving the below-the-knee arterial tree is diffuse in the majority of patients. The cornerstone of therapy is vascular reconstruction and limb salvage. Revascularization should be attempted whenever technically possible, without delay, in patients presenting critical limb ischemia and when the clinical status is not hopelessly non-ambulatory. Therefore, endovascular treatment can become the gold standard for the full range of patients including below-the-knee, limiting the clinical role of the classically trained surgeons.

Intraoperative Neurophysiological Monitoring : A Review of Techniques Used for Brain Tumor Surgery in Children

  • Kim, Keewon;Cho, Charles;Bang, Moon-suk;Shin, Hyung-ik;Phi, Ji-Hoon;Kim, Seung-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.3
    • /
    • pp.363-375
    • /
    • 2018
  • Intraoperative monitoring (IOM) utilizes electrophysiological techniques as a surrogate test and evaluation of nervous function while a patient is under general anesthesia. They are increasingly used for procedures, both surgical and endovascular, to avoid injury during an operation, examine neurological tissue to guide the surgery, or to test electrophysiological function to allow for more complete resection or corrections. The application of IOM during pediatric brain tumor resections encompasses a unique set of technical issues. First, obtaining stable and reliable responses in children of different ages requires detailed understanding of normal age-adjusted brain-spine development. Neurophysiology, anatomy, and anthropometry of children are different from those of adults. Second, monitoring of the brain may include risk to eloquent functions and cranial nerve functions that are difficult with the usual neurophysiological techniques. Third, interpretation of signal change requires unique sets of normative values specific for children of that age. Fourth, tumor resection involves multiple considerations including defining tumor type, size, location, pathophysiology that might require maximal removal of lesion or minimal intervention. IOM techniques can be divided into monitoring and mapping. Mapping involves identification of specific neural structures to avoid or minimize injury. Monitoring is continuous acquisition of neural signals to determine the integrity of the full longitudinal path of the neural system of interest. Motor evoked potentials and somatosensory evoked potentials are representative methodologies for monitoring. Free-running electromyography is also used to monitor irritation or damage to the motor nerves in the lower motor neuron level : cranial nerves, roots, and peripheral nerves. For the surgery of infratentorial tumors, in addition to free-running electromyography of the bulbar muscles, brainstem auditory evoked potentials or corticobulbar motor evoked potentials could be combined to prevent injury of the cranial nerves or nucleus. IOM for cerebral tumors can adopt direct cortical stimulation or direct subcortical stimulation to map the corticospinal pathways in the vicinity of lesion. IOM is a diagnostic as well as interventional tool for neurosurgery. To prove clinical evidence of it is not simple. Randomized controlled prospective studies may not be possible due to ethical reasons. However, prospective longitudinal studies confirming prognostic value of IOM are available. Furthermore, oncological outcome has also been shown to be superior in some brain tumors, with IOM. New methodologies of IOM are being developed and clinically applied. This review establishes a composite view of techniques used today, noting differences between adult and pediatric monitoring.

Pig Spermatozoa Defect in Acrosome Formation Caused Poor Motion Parameters and Fertilization Failure through Artificial Insemination and In vitro Fertilization

  • Lee, Won Young;Lee, Ran;Kim, Hee Chan;Lee, Kyung Hoon;Cui, Xiang Shun;Kim, Nam Hyung;Kim, Sang Hyun;Lee, Il Joo;Uhm, Sang Jun;Yoon, Min Jung;Song, Hyuk
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.10
    • /
    • pp.1417-1425
    • /
    • 2014
  • The selection of morphologically normal spermatozoa is critical to obtain high breeding performances in boar breeding farms and artificial insemination (AI) centers. Parameters for the selection of semen mainly include total sperm motility, concentration, and morphology. However, these primary parameters are often not reliable for discriminating between normal and abnormal, non-fertilizable spermatozoa. The present study was designed to compare the motion characteristics, fertilization ability using in vitro fertilization (IVF), and acrosome formation of the semen from boars having low (boar number 2012) and normal (boar number 2004 and 2023) breeding performances. The ultimate goal was to identify additional simple and easy criteria for the selection of normal sperm. There was no significant difference between boar 2004 and boar 2023 sperm total motility in computer assisted sperm analysis. However, boar number 2012 semen presented a significantly reduced population of rapid moving spermatozoa and an increased population of slow moving spermatozoa compared to boar numbers 2004 and 2023. Analysis of detailed motion characteristics revealed that sperm from boar number 2012 had significantly reduced motility in progressiveness, average path velocity, straight-line velocity (VSL), curvilinear velocity (VCL), straightness, and linearity. The assessment of the fertilizing ability by IVF also showed that sperm from boar number 2012 showed a fertility rate of 3.4%, whereas sperm from boar number 2023 had a fertility rate of 75.45%. Interestingly, most of the sperm nuclei were found on the peripheral area of the oocytes, suggesting that the sperm from boar number 2012 lacked penetration ability into the oocyte zonapellucida. The acrosome formation analysis using Pisum sativum agglutinin staining demonstrated that the sperm from boar number 2012 had a defect in acrosome formation. Consequently, primary parameters for selecting semen before AI such as motility are not sufficient to select normal and fertilizable spermatozoa. In conclusion, the present study suggests that the acrosome staining and detailed motion characteristics such as progressiveness, VCL, and VSL should be included in determining semen quality together with primary parameters for successful AI and high breeding performance in the swine industry.