• Title/Summary/Keyword: performance test

Search Result 21,458, Processing Time 0.049 seconds

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.

Benchmark Test Study of Localized Digital Streamer System (국산화 디지털 스트리머 시스템의 벤치마크 테스트 연구)

  • Jungkyun Shin;Jiho Ha;Gabseok Seo;Young-Jun Kim;Nyeonkeon Kang;Jounggyu Choi;Dongwoo Cho;Hanhui Lee;Seong-Pil Kim
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.2
    • /
    • pp.52-61
    • /
    • 2023
  • The use of ultra-high-resolution (UHR) seismic surveys to preceisly characterize coastal and shallow structures have increased recently. UHR surveys derive a spatial resolution of 3.125 m using a high-frequency source (80 Hz to 1 kHz). A digital streamer system is an essential module for acquiring high-quality UHR seismic data. Localization studies have focused on reducing purchase costs and decreasing maintenance periods. Basic performance verification and application tests of the developed streamer have been successfully carried out; however, a comparative analysis with the existing benchmark model was not conducted. In this study, we characterized data obtained by using a developed streamer and a benchmark model simultaneously. Tamhae 2 and auxiliary equipment of the Korea Institute of Geoscience and Mineral Resources were used to acquire 2D seismic data, which were analyzed from different perspectives. The data obtained using the developed streamer differed in sensitivity from that obtained using benchmark model by frequency band.However, both type of data had a very high level of similarity in the range corresponding to the central frequency band of the seismic source. However, in the low frequency band below 60 Hz, data obtained using the developed streamer showed a lower signal-to-noise ratio than that obtained using the benchmark model.This lower ratio can hinder the quality in data acquisition using low-frequency sound sources such as cluster air guns. Three causes for this difference were, and streamers developed in future will attempt to reflect on these improvements.

Development and Evaluation of Multiplex PCR for the Detection of Carbapenemase-Producing Enterobacteriaceae (카바페넴분해효소 생성 장내세균 검출을 위한 Multiplex PCR의 개발 및 평가)

  • Kim, Si Hyun;Bae, Il Kwon;Kim, Na Young;Song, Sae Am;Kim, Sunjoo;Jeong, Joseph;Shin, Jeong Hwan
    • Annals of Clinical Microbiology
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2019
  • Background: The isolation of carbapenemase-producing Enterobacteriaceae (CPE) has become increasingly common. Continuous surveillance for these organisms is essential because their infections are closely related to outbreaks of illness and are associated with high mortality rates. The aim of this study was to develop and evaluate multiplex PCR as a means of detecting several important CPE genes simultaneously. Methods: We aimed to develop a multiplex PCR that could detect seven CPE genes simultaneously. The multiplex PCR was composed of seven primer sets for the detection of KPC, IMP, VIM, NDM-1, GES, OXA-23, and OXA-48. We designed different PCR product sizes of at least 100 bp. We evaluated the performance of this new test using 69 CPE-positive clinical isolates. Also, we confirmed the specificity to rule out false-positive reactions by using 71 carbapenem-susceptible clinical strains. Results: A total of 69 CPE clinical isolates showed positive results and were correctly identified as KPC (N=14), IMP (N=13), OXA-23 (N=12), OXA-48 (N=11), VIM (N=9), GES (N=5), and NDM (N=5) by the multiplex PCR. All 71 carbapenem-susceptible clinical isolates, including Enterococcus faecalis, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, and Pseudomonas aeruginosa, showed negative results. Conclusion: This multiplex PCR can detect seven CPE genes at a time and will be useful in clinical laboratories.

Evaluation of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR for the Diagnosis of Malaria (LG AdvansureTM Malaria P.f./P.v. real-time QPCR의 말라리아 진단 유용성)

  • Lee, Hye Jin;Kim, Ha Nui;Yoo, Byong Joon;Kim, Jang Su;Kim, Myong Han;Lim, Chae Seung;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.2
    • /
    • pp.100-104
    • /
    • 2011
  • Background: Malaria is a problematic disease in Korea, and microscopic examination of Giemsa-stained blood smear has been used as the gold standard for its diagnosis. However, this technique is time-consuming and has low sensitivity in samples with low numbers of malarial parasites (<20 parasites/μL). Here, we evaluated the performance characteristics of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR (LG life sciences, Korea). Methods: Blood samples from 173 persons who visited Korea University Ansan Hospital were evaluated. QPCR was performed in 73 malaria patients and 100 healthy subjects by using the LG Advansure Malaria P.f./P.v. real-time QPCRR kit, and the results were compared with those of microscopy. The detection limit of this kit was determined by serial dilution of Plasmodium-infected blood with normal blood (blood not infected with Plasmodium). Results: Among the 73 patients that were microscopically confirmed to have malaria (Plasmodium vivax infection, N=70, P. falciparum infection, N=3), 69 patients were diagnosed with P. vivax infection and 3 were diagnosed with P. falciparum infection by LG AdvansureTM Malaria P.f./P.v. realtime QPCR. Both the tests indicated absence of infection in the 100 healthy subjects. The detection limit of LG AdvansureTM Malaria P.f./P.v. real-time QPCR was 0.1 parasite/μL. Conclusions: LG AdvansureTM Malaria P.f./P.v. real-time QPCRis a very sensitive and specific technique and can be used as a confirmatory test for malaria.

Survey of Operation and Status of the Human Research Protection Program (HRPP) in Korea (2019) (임상시험 및 대상자보호프로그램의 운영과 현황에 대한 설문조사 연구(2019))

  • Maeng, Chi Hoon;Lee, Sun Ju;Cho, Sung Ran;Kim, Jin Seok;Rha, Sun Young;Kim, Yong Jin;Chung, Jong Woo;Kim, Seung Min
    • The Journal of KAIRB
    • /
    • v.2 no.2
    • /
    • pp.37-48
    • /
    • 2020
  • Purpose: The purpose of this study is to assess the operational status and level of understanding among IRB and HRPP staffs at a hospital or a research institute to the HRPP guideline set by the Ministry of Food and Drug Safety (MFDS) and to provide recommendations. Methods: Online survey was distributed among members of Korean Association of IRB (KAIRB) through each IRB office. The result was separated according to topic and descriptive statistics was used for analysis. Result: Survey notification was sent out to 176 institutions and 65 (37.1%) institutions answered the survey by online. Of 65 institutions that answered the survey; 83.1% was hospital, 12.3% was university, 3.1% was medical college, 1.5% was research institution. 23 institutions (25.4%) established independent HRPP offices and 39 institutions (60.0%) did not. 12 institutions (18.5%) had separate IRB and HRPP heads, 21 (32.3%) institutions separated business reporting procedure and person in charge, 12 institutions separated the responsibility of IRB and HRPP among staff, and 45 institutions (69.2%) had audit & non-compliance managers. When asked about the most important basic task for HRPP, 23% answered self-audit. And according to 43.52%, self-audit was also the most by both institutions that operated HRPP and institutions that did not. When basic task performance status was analyzed, on average, the institutions that operated HRPP was 14% higher than institutions that only operated IRB. 9 (13.8%) institutions were evaluated and obtained HRPP accreditation from MFDS and the most common reason for obtaining the accreditation was to be selected as Institution for the education of persons conducting clinical trial (6 institutions). The most common reason for not obtaining HRPP accreditation was because of insufficient staff and limited capacity of the institution (28%). Institutions with and without a plan to be HRPP accredited by MFDS were 20 (37.7%) each. 34 institutions (52.3%) answered HRPP evaluation method and accreditation by MFDS was appropriate while 31 institutions (47.7%) answered otherwise. 36 institutions answered that HRPP evaluation and accreditation by MFDS was credible while 29 institutions (44.5%) answered that HRPP evaluation method and accreditation by MFDS was not credible. Conclusion: 1. MFDS's HRPP accreditation program can facilitate the main objective of HRPP and MFDS's HRPP accreditation program should be encouraged to non-tertiary hospitals by taking small staff size into consideration and issuing accreditation by segregating accreditation. 2. While issuing Institution for the education of persons conducting clinical trial status as a benefit of MFDS's HRPP accreditation program, it can also hinder access to MFDS's HRPP accreditation program. It should also be considered that the non-contact culture during COVID-19 pandemic eliminated time and space limitation for education. 3. For clinical research conducted internally by an institution, internal audit is the most effective and sole method of protecting safety and right of the test subjects and integrity for research in Korea. For this reason, regardless of the size of the institution, an internal audit should be enforced. 4. It is necessary for KAIRB and MFDSto improve HRPP awareness by advocating and educating the concept and necessity of HRPP in clinical research. 5. A new HRPP accreditation system should be setup for all clinical research with human subjects, including Investigational New Drug (IND) application in near future.

  • PDF

Behavior Analysis of Concrete Structure under Blast Loading : (I) Experiment Procedures (폭발하중을 받는 콘크리트 구조물의 실험적 거동분석 : (I) 실험수행절차)

  • Yi, Na Hyun;Kim, Sung Bae;Kim, Jang-Ho Jay;Choi, Jong Kwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.557-564
    • /
    • 2009
  • In recent years, there have been numerous explosion-related accidents due to military and terrorist activities. Such incidents caused not only damages to structures but also human casualties, especially in urban areas. To protect structures and save human lives against explosion accidents, better understanding of the explosion effect on structures is needed. In an explosion, the blast overpressure is applied to concrete structures as an impulsive load of extremely short duration with very high pressure and heat. Generally, concrete is known to have a relatively high blast resistance compared to other construction materials. However, information and test results related to the blast experiment of internal and external have been limited due to military and national security reasons. Therefore, in this paper, to evaluate blast effect on reinforced have concrete structure and its protective performance, blast tests are carried out with $1.0m{\times}1.0m{\times}150mm$ reinforce concrete slab structure at the Agency for Defence Development. The standoff blast distance is 1.5 m and the preliminary tests consists with TNT 9 lbs and TNT 35 lbs and the main tests used ANFO 35 lbs. It is the first ever blast experiment for nonmilitary purposes domestically. In this paper, based on the basic experiment procedure and measurement details for acquiring structural behavior data, the blast experimental measurement system and procedure are established details. The procedure of blast experiments are based on the established measurement system which consists of sensor, signal conditioner, DAQ system, software. It can be used as basic research references for related research areas, which include protective design and effective behavior measurements of structure under blast loading.

Effect of Drying Type and Addition Level of Sweet Potato 'Tongchaeru' Byproducts on Broiler Productivity, Meat Quality, Blood Parameters, and Immune Response (고구마 '통채루' 부산물의 건조 방법과 첨가 수준에 따른 육계 생산성, 계육 품질, 혈액 성상, 면역 지표에 미치는 영향)

  • Woo-Do Lee;Hyunsoo Kim;Jiseon Son;Eui-Chul Hong;Hee-Jin Kim;Yeon-Seo Yun;Hye Kyung Shin;Hwan-Ku Kang
    • Korean Journal of Poultry Science
    • /
    • v.50 no.4
    • /
    • pp.325-336
    • /
    • 2023
  • This study used leaves and stems of 'Tongchaeru', one of the sweet potato varieties, to investigate broiler productivity, meat quality, blood properties, growth hormones, and immune factor levels according to drying method and amount added to feed. For this experiment, a total of 720 1-day-old male Ross 308 broilers were used. Treatments were assigned with 3 replicates per treatment and 20 birds were assigned to each replicate. The treatment group was designed into 12 treatments according to the type of natural product (leaves (L), stems (S)), drying type (natural (N), hot air (H), freeze (F)) and amount added (0.1%, 0.3%). The test was conducted for a total of 5 weeks. In this study, there was no significant difference in productivity depending on the type and amount of additives added (P>0.05). The FS 0.3% group showed high pH and WHC levels, and the shear force was lowest at HL 0.1% group (P<0.05). Blood cell and serum biochemical components were similar in all treatments, and growth hormone IGF-1 was highest in FS 0.1% group (P<0.05). There was no significant difference in IFN-γ, but the highest level of IL-6 was seen in the HS 0.1% group (P<0.05). In conclusion, the meat quality and the level of growth hormone and immune factors in the body were different depending on the type and amount of dried leaves and stems of sweet potato 'Tongchaeru', further study is needed to compare the selected additives and amounts added with those without additions.

Assessment of water supply reliability in the Geum River Basin using univariate climate response functions: a case study for changing instreamflow managements (단변량 기후반응함수를 이용한 금강수계 이수안전도 평가: 하천유지유량 관리 변화를 고려한 사례연구)

  • Kim, Daeha;Choi, Si Jung;Jang, Su Hyung;Kang, Dae Hu
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.993-1003
    • /
    • 2023
  • Due to the increasing greenhouse gas emissions, the global mean temperature has risen by 1.1℃ compared to pre-industrial levels, and significant changes are expected in functioning of water supply systems. In this study, we assessed impacts of climate change and instreamflow management on water supply reliability in the Geum River basin, Korea. We proposed univariate climate response functions, where mean precipitation and potential evaporation were coupled as an explanatory variable, to assess impacts of climate stress on multiple water supply reliabilities. To this end, natural streamflows were generated in the 19 sub-basins with the conceptual GR6J model. Then, the simulated streamflows were input into the Water Evaluation And Planning (WEAP) model. The dynamic optimization by WEAP allowed us to assess water supply reliability against the 2020 water demand projections. Results showed that when minimizing the water shortage of the entire river basin under the 1991-2020 climate, water supply reliability was lowest in the Bocheongcheon among the sub-basins. In a scenario where the priority of instreamflow maintenance is adjusted to be the same as municipal and industrial water use, water supply reliability in the Bocheongcheon, Chogang, and Nonsancheon sub-basins significantly decreased. The stress tests with 325 sets of climate perturbations showed that water supply reliability in the three sub-basins considerably decreased under all the climate stresses, while the sub-basins connected to large infrastructures did not change significantly. When using the 2021-2050 climate projections with the stress test results, water supply reliability in the Geum River basin was expected to generally improve, but if the priority of instreamflow maintenance is increased, water shortage is expected to worsen in geographically isolated sub-basins. Here, we suggest that the climate response function can be established by a single explanatory variable to assess climate change impacts of many sub-basin's performance simultaneously.

Vitamin D analysis in the Korean total diet study and UV/sun light irradiated mushrooms (한국형 총식이조사 및 UV/태양광 조사 버섯에서의 비타민 D 분석)

  • Min-Jeong Seo;In-Hwa Roh;Jee-Yeon Lee;Sung-Ok Kwon;Cho-Il Kim;Gae-Ho Lee
    • Food Science and Preservation
    • /
    • v.30 no.1
    • /
    • pp.109-121
    • /
    • 2023
  • This study was conducted to evaluate vitamin D intake of Koreans in a total diet study (TDS) and to determine the effect of irradiation on vitamin D synthesis in mushrooms. For analysis, sample were saponified and extracted with hexane, and vitamin D was quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Based on the validation results, the recovery of the National Institute of Standards and Technology (NIST) standard reference sample (SRM) 1849a was 96.7% and the z-score of -1.6 was obtained by the Food Analysis Performance Assessment Scheme (FAPAS) proficiency test (PT) 21115. Vitamin D2 was not detected in any samples, and the highest level of vitamin D3 was detected in mackerel and anchovies ranging from 24.2 to 120.2 ㎍/kg. The mean daily intake of vitamin D was 0.99 ㎍/day, as estimated from the vitamin D contents of the analyzed foods and their corresponding intake. The adequate intake (AI) of vitamin D based on the Dietary reference intakes for Koreans provided by the Ministry of Health and Welfare is 5-15 ㎍/day for Koreans aged 6 to 75 years. Compared with this AI, vitamin D intake of Koreans estimated in this study was inadequate. For that, the increased vitamin D content in ultraviolet (UV)/sun light irradiated mushrooms warrants further research to increase vitamin D intake of Koreans through diet.