• Title/Summary/Keyword: performance test

Search Result 21,718, Processing Time 0.043 seconds

Performance test of Vitiated Air Heater with High Temperature and High Pressure I (고온 고압 공기가열기 성능시험 I)

  • Lee, Jungmin;Na, Jaejeong;Hong, Yunky;Kang, Kyungtaik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.301-303
    • /
    • 2017
  • This study is the performance test of the vitiated air heater with high temperature and high pressure. The vitiated air heater to provide hot air about 2000 K was designed, and the performance test is carrying out. The designed vitiated air heater uses methane, oxygen, and mixing air by working gases, and uses mixing air for cooling of the bottom of a mixing head. By this reason, the vitiated ar heater has to be designed with heat-resistance from hot frame, and to be tested for its proof. In this paper the performance of he vitiated air heater is analyzed to some test results.

  • PDF

Configuration Design, Hot-firing Test and Performance Evaluation of 200 N-Class GCH4/LOx Small Rocket Engine (Part II: Steady State-mode Ground Hot-firing Test) (200 N급 GCH4/LOx 소형로켓엔진의 형상설계와 성능시험평가 (Part II: 정상상태 지상연소시험))

  • Kim, Min Cheol;Kim, Young Jin;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.1
    • /
    • pp.9-16
    • /
    • 2020
  • A performance evaluation of the 200 N-class GCH4/LOx small rocket engine was performed through ground hot-firing test. As a result, the combustion pressure and thrust raised with the increase of the oxidizer supply pressure, and thus the specific impulse, characteristic velocity, and their efficiency increased. The characteristic velocity was measured at about 90% performance efficiency. The change of chamber aspect ratio did not affect the performance of the rocket engine in the test condition specified. In addition, uncertainty evaluation was conducted to ensure the reliability of the test results.

Improving efficiency through the hydrological observation equipment performance test center and program (수문관측설비 성능시험센터 구축 및 프로그램 개발을 통한 효율 향상 방안)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2731-2738
    • /
    • 2015
  • The importance of disaster observation facilities and system are increasing around the world in order to predict and prevent water disasters, which cause serious damage to life and property. A performance test center was built to stabilize performance, compatibility, and reliability of devices, and to verify new S/W. The aim of this study is to make a guideline to build standard verifying system for hydrological observation devices by building the performance test center. In addition, efficiency of management and operation of hydrological devices can be enhanced through device analysis, maintenance, database building, and grade certificate publishment after the device test.

A Study on the Construction of a TestBed for Performance Inspection of Underground Surveying Equipment (지하공간탐사기기 성능검사 테스트베드 구축 연구)

  • Bae, Kyoung Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.525-531
    • /
    • 2021
  • The importance and utilization of underground spatial is increasing due to urban concentration. And so underground spatial information is being built. Because underground spatial information is an important NSDI (National Spatial Data Infrastructure), the accuracy and performance of underground spatial exploration devices used for construction are managed separately. In accordance with the laws and regulations related to spatial information, the government is conducting performance tests for underground facilities surveying equipment. The current performance test site mainly targets metal pipelines, and there is no absolute position surveying inspection system. In this study, test bed model for performance inspection of underground space exploration equipment was presented. The test bed presented in this study can be used as a test site to supplement the limitations of the existing domestic test bed and to verify the performance of the latest equipment.

A Pilot Study for the Standardization of a Multiple Intelligences Performance Test for Preschoolers (유아를 위한 수행형 다중지능 검사의 표준화 예비연구)

  • Chang-Song, You-Kyung;Choi, Yun-Young
    • Korean Journal of Child Studies
    • /
    • v.29 no.6
    • /
    • pp.163-176
    • /
    • 2008
  • The purpose of this study was to develop a standardized performance style Multiple Intelligences Test for preschoolers(MIT-P). A total of 270 preschoolers(3~5-years-old) participated in this study. Tools and procedures were developed to measure performance in 7 areas of multiple Intelligences(linguistic, mathematical, science, social, music, art and kinesthetic). The final test set included 138 items. Reliability of the MIT-P was relatively high(Cronbach alpha =.92). Intercorrelations among measures of the 7 areas indicated construct validity. Based on these results, the pilot study of MIT-P is considered adequate to form the basis of a new test that would help teachers and parents to identify children's strengths and weaknesses and may be useful for educational planning.

  • PDF

Seismic Performance Evaluation of Circular RC Bridge Piers with Various Steel Type (원형 실물 철근 콘크리트 교각의 철근 상세에 따른 내진성능 평가)

  • 정영수;박진영;이재훈;조대연;이대형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.965-970
    • /
    • 2001
  • The object of this research is to evaluate the seismic performance of existing RC bridge piers that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification in 1992. In this research, adopted test parameters were limited ductile design or non-seismic design, aspect ratio, confinement steel type, loading pattern, lap-spliced ratio for longitudinal reinforcement. This study has been performed to verify the effect of test parameter by quasi-static test. Quasi-static test has been done to investigate the physical seismic performance of RC bridge piers, such as lateral force-displacement hysteretic curve, envelope curve etc. It has been observed that seismic performance of lap-spliced test specimen, non-seismically designed specimens, was significantly reduced.

  • PDF

The Fatigue Performance Evaluation of Concrete Specimen by Using Mineral Admixture (혼화재 사용에 따른 콘크리트 시험체의 피로성능 평가)

  • Kim, Doo-Hwan;Baek, Kyung-Su
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.5
    • /
    • pp.39-43
    • /
    • 2010
  • The surfacing of bridge-decks are object to secure trafficability and to protect bridge face from impact load of traffic volume and other external conditions. But the deformation of pavements and cracks happen due to the damage of the bridge-decks surfacing from the increase of the traffic, short maintenance period and continuous vibration of bridge. This test is to make the 3-type high performance concrete that has different mixing ratio and is added the blast furnace slag, fly ash and silica respectively, and to compare 3-type high performance concrete of normal high strength concrete of $400kgf/cm^2$ strength through the static loading test and fatigue test. And test specimen is united floor slab and pavement for the durability of bridge.

Assessment of Structural Performance for a Lightweight Soundproof Tunnel Composed of Partitioned Pipe Truss Members (격벽화된 파이프 트러스 요소로 구성된 경량방음터널의 구조적 성능 평가)

  • Noh, Myung-Hyun;Ahn, Dong-Wook;Joo, Hyung-Joong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, the full-size structural performance test for a lightweight soundproof tunnel composed of partitioned pipe truss members is carried out to investigate the structural performance. In addition, a nonlinear structural analysis of the same finite element model as the full-size testing model is performed to compare the test result. The test and analysis results showed that the lightweight soundproof tunnel ensures the structural safety against wind loads, snow loads and load combinations. As a result, the full-size test and analysis results meet all the design load conditions, hence the proposed lightweight soundproof tunnel is ready for the field application.

An Investigation of Performance Change of Diesel Oxidation Catalyst for Diesel Vehicle (경유차 적용 디젤산화촉매장치의 성능 변화 분석)

  • Hwang, Jin-Woo;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2009
  • This paper is to investigated the analysis of performance characteristics of diesel oxidation catalyst (DOC) for diesel vehicle with 2.5L piston displacement. The performance evaluation test of DOC applied to test diesel vehicle was carried out for four kinds of DOCs manufactured from different company. The testing DOCs were randomly selected from the retrofit vehicle and then standard test vehicle that was representative for the application group was equipped with DOC for the test. In this verification test, the reduction rate of particulate matter (P.M.) and the deviation of the performance of the DOC were examined through CVS-75 mode of the standard vehicle and SOF reduction rate of specific DOC was investigated. It was found that some DOCs failed to pass the criteria of the P.M. reduction rate because of the reason seen catalyst aging even if they were same devices. In the result of SOF analysis, the specific DOC showed more PM reduction than SOF of PM. reduction exceptionally.

  • PDF

Performance Evaluation Procedure for Advanced Emergency Braking System (자동비상제동 시스템의 안전성능평가)

  • Kim, Taewoo;Yi, Kyongsu;Choi, In Seong;Min, Kyong Chan
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.2
    • /
    • pp.25-31
    • /
    • 2015
  • This paper presents a performance evaluation procedure for advanced emergency braking (AEB) system. To guarantee the performance of AEB system, AEB test scenario should contains various driving conditions which can be occurred in real driving condition. Also, performances of each elements of AEB system, such as sensor, decision, human machine interface (HMI) and control, should be evaluated in various situations. For this, driving conditions, road types, environment, and elements of AEB system were introduced. Test scenario has been designed to represent the real driving condition and to evaluate the safety performance of AEB system in various situations. To confirm that the proposed AEB test scenario is realistic and physically meaningful, vehicle test have been conducted in two cases of proposed AEB test scenario: subject vehicle cut-out scenario and narrow street turn left scenario.