• Title/Summary/Keyword: performance of the test.

Search Result 21,547, Processing Time 0.056 seconds

Postprandial hypoglycemic effects of mulberry twig and root bark in vivo and in vitro (In vivo와 in vitro에서 상지 및 상백피 에탄올추출물이 식후 혈당 상승 억제 조절에 미치는 영향)

  • Park, Soo Yeon;Jin, Bo Ra;Lee, Yu Rim;Kim, You Jin;Park, Jeong Bin;Jeon, Young Hee;Choi, Sang Won;Kwon, Oran
    • Journal of Nutrition and Health
    • /
    • v.49 no.1
    • /
    • pp.18-27
    • /
    • 2016
  • Purpose: Our previous study demonstrated the hypoglycemic effects of mulberry (Morus alba L.) leaf and the underlying mechanisms. Here we explored the potency of mulberry twigs (TW) and root barks (RB) in postprandial hypoglycemic effects in vitro and in vivo. Methods: The major components of TW and RB were determined by high performance liquid chromatography (HPLC). Alpha-glucosidase inhibition and glucose/fructose uptake inhibition in Caco-2 cells were determined for TW, RB, and their major components, followed by an oral sugar tolerance test (OSTT) in streptozotocin-induced diabetic rats. Male Wistar rats were fed a high-fat diet for 2 weeks and then a single dose of streptozotocin (35 mg/kg B.W) was administered by intraperitoneal injection. Rats with fasting blood glucose levels above 126 mg/dL were randomly divided into 5 groups (n = 8/group) for the following treatments by gavage for 4 weeks: vehicle (normal control and diabetic control), 200 mg/kg B.W of TW or RB or 100 mg/kg B.W of oxyresveratrol (OXY). Results: OXY and mulberroside A were identified as the major components of TW and OXY, mongolicin, and kuwanon H for RB. A significant inhibitory activity on ${\alpha}-glucosidase$ was found for TW, RB, and OXY (p = 0.0099). There was a dose-dependent inhibition of TW and RB on the intestinal sugar uptakes in Caco-2 cells, showing a greater impact on fructose compared to glucose. The OSTT showed that TW and RB significantly delayed time to maximal concentration (p = 0.0088) and decreased maximal concentration (p = 0.0043) compared to the control group. Conclusion: These results suggest that TW and RB may have a postprandial hypoglycemic effect, particularly in the case of high fructose or sucrose intake. OXY was suggested as a contributor to the hypoglycemic effect of TW and RB. Further studies are needed for the systemic effect of TW and RB in circulation.

H.264/SVC Spatial Scalability Coding based Terrestrial Multi-channel Hybrid HD Broadcasting Service Framework and Performance Analysis on H.264/SVC (H.264/SVC 공간 계위 부호화 기반 지상파 다채널 하이브리드 고화질 방송 서비스 프레임워크 및 H.264/SVC 부호화 성능 평가)

  • Kim, Dae-Eun;Lee, Bum-Shik;Kim, Mun-Churl;Kim, Byung-Sun;Hahm, Sang-Jin;Lee, Keun-Sik
    • Journal of Broadcast Engineering
    • /
    • v.17 no.4
    • /
    • pp.640-658
    • /
    • 2012
  • One of the existing terrestrial multi-channel DTV service frameworks, called KoreaView, provides four programs, composed of MPEG-2 based one HD video and H.264/AVC based three SD videos within one single 6MHz frequency bandwidth. However the additional 3 SD videos can not provide enough quality due to its reduced spatial resolution and low target bitrates. In this paper, we propose a framework, which is called a terrestrial multi-channel high quality hybrid DTV service, to overcome such a weakness of KoreaView services. In the proposed framework, the three additional SD videos are encoded based on an H.264/SVC Spatial Base layer, which is compliant with H.264/AVC, and are delivered via broadcasting networks. On the other hand, and the corresponding three additional HD videos are encoded based on an H.264/SVC Spatial Enhancement layer, which are transmitted over broadband networks such as Internet, thus allowing the three additional videos for users with better quality of experience. In order to verify the effectiveness of the proposed framework, various experimental results are provided for real video contents being used for DTV services. First, the experimental results show that, when the SD sequences are encoded by the H.264/SVC Spatial Base layer at a target bitrate of 1.5Mbps, the resulting PSNR values are ranged from 34.5dB to 42.9dB, which is a sufficient level of service quality. Also it is noted that 690kbps-8,200kbps are needed for the HD test sequences when they are encoded in the H.264/SVC Spatial Enhancement layer at similar PSNR values for the same HD sequences encoded by MPEG-2 at a target bitrate of 12 Mbps.

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.

Effectiveness of Sodium Iodide Root Canal Filling Pastes in Primary Teeth (요오드화 나트륨을 사용한 유치 근관 충전재의 효과)

  • Soo Jin Chang;Yujin Kim;Junghwan Lee;Jongsoo Kim;Joonhaeng Lee;Mi Ran Han;Jisun Shin;Jongbin Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.168-178
    • /
    • 2023
  • Objectives: This study aimed to compare the physical properties and antibacterial effectiveness of iodoform based root filling pastes, Vitapex® and Metapex®, with sodium iodide root filling paste (NaI paste) for primary teeth. Materials and Methods: The physical properties (flowability, film thickness, radiopacity) of the pastes were evaluated according to ISO 6876:2012. The antibacterial activity against Enterococcus faecalis strain (ATCC 6538) was evaluated using a direct contact test. Results: There was no significant statistical difference (p > 0.05) observed in the flow and film thickness of NaI paste when compared to the currently available root canal filling materials. The average flow capacities for Vitapex®, Metapex®, and NaI paste were 15.40 mm, 21.25 mm, and 20.01 mm, respectively. The average film thickness for Vitapex®, Metapex®, and NaI paste were 33.3 ㎕, 22.6 ㎕, and 25.0 ㎕, respectively. However, NaI paste showed lower radiopacity than the existing materials, and this difference was statistically significant (p < 0.05) NaI paste demonstrated higher antimicrobial activity than the available materials, and this difference was also statistically significant (p < 0.05). Conclusion: Compared to the existing commercialized root canal filling materials, NaI paste exhibited similar performance in terms of flow and film thickness, and superior antimicrobial activity against E. faecalis. Hence, NaI paste could be a promising root filling material for primary teeth and may be a potential alternative to existing materials.

Evaluation of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR for the Diagnosis of Malaria (LG AdvansureTM Malaria P.f./P.v. real-time QPCR의 말라리아 진단 유용성)

  • Lee, Hye Jin;Kim, Ha Nui;Yoo, Byong Joon;Kim, Jang Su;Kim, Myong Han;Lim, Chae Seung;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.2
    • /
    • pp.100-104
    • /
    • 2011
  • Background: Malaria is a problematic disease in Korea, and microscopic examination of Giemsa-stained blood smear has been used as the gold standard for its diagnosis. However, this technique is time-consuming and has low sensitivity in samples with low numbers of malarial parasites (<20 parasites/μL). Here, we evaluated the performance characteristics of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR (LG life sciences, Korea). Methods: Blood samples from 173 persons who visited Korea University Ansan Hospital were evaluated. QPCR was performed in 73 malaria patients and 100 healthy subjects by using the LG Advansure Malaria P.f./P.v. real-time QPCRR kit, and the results were compared with those of microscopy. The detection limit of this kit was determined by serial dilution of Plasmodium-infected blood with normal blood (blood not infected with Plasmodium). Results: Among the 73 patients that were microscopically confirmed to have malaria (Plasmodium vivax infection, N=70, P. falciparum infection, N=3), 69 patients were diagnosed with P. vivax infection and 3 were diagnosed with P. falciparum infection by LG AdvansureTM Malaria P.f./P.v. realtime QPCR. Both the tests indicated absence of infection in the 100 healthy subjects. The detection limit of LG AdvansureTM Malaria P.f./P.v. real-time QPCR was 0.1 parasite/μL. Conclusions: LG AdvansureTM Malaria P.f./P.v. real-time QPCRis a very sensitive and specific technique and can be used as a confirmatory test for malaria.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Air Sampling and Isotope Analyses of Water Vapor and CO2 using Multi-Level Profile System (다중연직농도시스템(Multi-Level Profile System)을 이용한 수증기와 이산화탄소 시료채취 및 안정동위원소 조성 분석)

  • Lee, Dong-Ho;Kim, Su-Jin;Cheon, Jung-Hwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.277-288
    • /
    • 2010
  • The multi-level $H_2O/CO_2$ profile system has been widely used to quantify the storage and advection effects on energy and mass fluxes measured by eddy covariance systems. In this study, we expanded the utility of the profile system by accommodating air sampling devices for isotope analyses of water vapor and $CO_2$. A pre-evacuated 2L glass flask was connected to the discharge of an Infrared Gas Analyzer (IRGA) of the profile system so that airs with known concentration of $H_2O$ and $CO_2$ can be sampled. To test the performance of this sampling system, we sampled airs from 8 levels (from 0.1 to 40 m) at the KoFlux tower of Gwangneung deciduous forest, Korea. Air samples in the 2L flask were separated into its component gases and pure $H_2O$ and $CO_2$ were extracted by using a vacuum extraction line. This novel technique successfully produced vertical profiles of ${\delta}D$ of $H_2O$ and ${\delta}^{13}C$ of $CO_2$ in a mature forest, and estimated ${\delta}D$ of evapotranspiration (${\delta}D_{ET}$) and ${\delta}^{13}C$ of $CO_2$ from ecosystem respiration (${\delta}^{13}C_{resp}$) by using Keeling plots. While technical improvement is still required in various aspects, our sampling system has two major advantages over other proposed techniques. First, it is cost effective since our system uses the existing structure of the profile system. Second, both $CO_2$ and $H_2O$ can be sampled simultaneously so that net ecosystem exchange of $H_2O$ and $CO_2$ can be partitioned at the same temporal resolution, which will improve our understanding of the coupling between water and carbon cycles in terrestrial ecosystems.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Sorghum Panicle Detection using YOLOv5 based on RGB Image Acquired by UAV System (무인기로 취득한 RGB 영상과 YOLOv5를 이용한 수수 이삭 탐지)

  • Min-Jun, Park;Chan-Seok, Ryu;Ye-Seong, Kang;Hye-Young, Song;Hyun-Chan, Baek;Ki-Su, Park;Eun-Ri, Kim;Jin-Ki, Park;Si-Hyeong, Jang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.4
    • /
    • pp.295-304
    • /
    • 2022
  • The purpose of this study is to detect the sorghum panicle using YOLOv5 based on RGB images acquired by a unmanned aerial vehicle (UAV) system. The high-resolution images acquired using the RGB camera mounted in the UAV on September 2, 2022 were split into 512×512 size for YOLOv5 analysis. Sorghum panicles were labeled as bounding boxes in the split image. 2,000images of 512×512 size were divided at a ratio of 6:2:2 and used to train, validate, and test the YOLOv5 model, respectively. When learning with YOLOv5s, which has the fewest parameters among YOLOv5 models, sorghum panicles were detected with mAP@50=0.845. In YOLOv5m with more parameters, sorghum panicles could be detected with mAP@50=0.844. Although the performance of the two models is similar, YOLOv5s ( 4 hours 35 minutes) has a faster training time than YOLOv5m (5 hours 15 minutes). Therefore, in terms of time cost, developing the YOLOv5s model was considered more efficient for detecting sorghum panicles. As an important step in predicting sorghum yield, a technique for detecting sorghum panicles using high-resolution RGB images and the YOLOv5 model was presented.

Physiological responses and subjective sensation of human body wearing Cool Mapsi in air-conditioning environment (냉방환경에서 쿨맵시 착용에 따른 생리적 반응과 주관적 감각)

  • Kang, Noo-Ri;Na, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.359-370
    • /
    • 2010
  • The purpose of this study is to test the performance of the recommended summer dressing for office man through the analysis of skin temperature changes by air-conditioning temperature. We tested two clothing combinations; formal wear with necktie and casual shirts without necktie as for Cool mapsi. 4 male subjects sat to stabilize for thirty minutes after entering artificial-climate chamber with both temperature of $25^{\circ}C$, $27^{\circ}C$ and $50{\pm}10%$ R.H. And during 60 minute experiments of simulating office work, the subjective feelings including thermal, humidity and comfort sensation, skin temperature, clothing humidity and sweat amount were measured at the equal intervals. The result is that formal wear of $25^{\circ}C$ and Cool mapsi of $27^{\circ}C$ show good values such as low skin temperature, low clothing humidity and neutral thermal sensation. And Cool mapsi of $25^{\circ}C$ shows the risk of low rectal temperature for long and static energy level of office work. Formal wear of $27^{\circ}C$ shows high values of mean skin temperature, clothing humidity and thermal sensation. Second experiment was to find the ambient temperature when the subject wearing formal wear shows the skin temperature corresponding to which he shows on Cool mapsi of $27^{\circ}C$. The air-conditioning temperature on wearing formal wear has to be $2^{\circ}C$ lower to produce the corresponding skin temperature to which shows on wearing Cool mapsi of $27^{\circ}C$. Therefore it is possible to increase room temperature to $27^{\circ}C$, when wear Cool mapsi for summer office, for skin temperature and thermal sensation are produced the same.

  • PDF